DH Beauty CS-118 3-IN-1 Multipolar RF Cavitation Slimming Machine

Model: CS-118

Introduction

The DH Beauty CS-118 is a versatile 3-in-1 Multipolar Radio Frequency (RF) and 40K Cavitation Ultrasonic Slimming System designed for comprehensive body shaping, skin lifting, and anti-aging treatments. This device combines advanced technologies to target fat cells, tighten skin, and improve overall skin elasticity and appearance. It is intended for use on the body and face to address concerns such as cellulite, wrinkles, and skin laxity.

DH Beauty CS-118 3-in-1 Multipolar RF Cavitation Slimming Machine

The DH Beauty CS-118 Mini Slimming System with its three treatment heads.

Safety Information

Please read and understand all safety precautions before operating the device.

  • Always clean the skin thoroughly before applying any special gel or slimming essential oils.
  • Remove all metal ornaments, jewelry, and accessories before using the machine to prevent interference or injury.
  • Avoid prolonged use in a single area. Move the treatment head continuously to prevent skin irritation or burns.
  • Do not use the device directly over bones or bony prominences.
  • After continuous operation for 1 hour, allow the machine to rest for approximately 10-15 minutes to prevent overheating and ensure longevity.
  • Some users may experience a temporary ringing sensation (tinnitus) when using the 40K Cavitation (burst fat) probe. This is a normal phenomenon and typically subsides after the treatment.
  • Do not use harsh disinfection products or alcohol to clean the probes. It is recommended to use a soft, wet towel or cotton pad for cleaning.
  • Keep the device out of reach of children.
  • Do not use if pregnant, breastfeeding, or if you have a pacemaker, metal implants, or severe medical conditions. Consult a physician if unsure.

Product Overview

The CS-118 Mini Slimming System includes a main host unit with an HD display and three specialized treatment heads, each designed for specific functions:

Product structure diagram showing main unit, 40K cavitation head, Level 6 RF head, and tertiary radio frequency head with labels.

Diagram of the CS-118 product structure and dimensions.

Components:

  • Host Unit (1x): Main control panel with HD display for mode, time, and power settings.
  • 40K Cavitation Handle (1x): For body slimming and fat reduction.
  • 6-Polar RF Body Handle (1x): For lymphatic drainage, skin firming, and enhancing skin elasticity on the body.
  • 3-Polar RF Face Handle (1x): For facial skin tightening, wrinkle removal, and restoring skin elasticity and gloss.
  • Bracket (1x): To hold the treatment heads when not in use.
  • Power Adapter (1x): For connecting the device to a power source.

Treatment Head Functions:

  • 40K Cavitation Body Slimming Head: Utilizes strong sound waves at 40KHZ to create a powerful impact on fat cells, causing them to burst and reduce. This process effectively burns calories, reduces moisture, and decreases the number of fat cells, leading to fat removal.
  • Sextupole RF Body Contour Head: Employs advanced sextupole RF technology to deeply penetrate and heat the fat layer. This accelerates the movement of fat cells, promoting heat generation, lymphatic drainage, and the elimination of excess fat and toxins from the body, thereby dissolving cellulite and firming the skin.
  • Three Pole RF Facial Wrinkle Elimination Head: Applies radio frequency to the skin, heating dermal collagen fibers to 45-65 degrees Celsius. This causes immediate collagen fiber contraction, stretching loose skin and wrinkles. It also stimulates dermal collagen proliferation, increasing skin thickness and density, resulting in wrinkle removal, scar reduction, and improved skin elasticity and gloss.

Specifications

FeatureSpecification
Item TypeBody Slimming Machine & Beauty Machine
Model NumberCS-118
Brand NameDH Beauty
Main MaterialABS & Metal
Voltage110V - 220V (US Plug variant: 100-110V)
Power200W
Frequency40KHZ (for Cavitation)
RF Frequency5MHZ
RF Level10
RF Handles3-pole RF head (Face), 6-polar RF head (Body)
ApplicationBody, Face
CertificationCE
Package Dimensions (L x W x H)31 cm x 24 cm x 14 cm
Package Weight1.95 kg
Dimensions of the main unit and treatment heads.

Detailed dimensions of the device components.

Setup

  1. Unpack: Carefully remove all components from the packaging: the host unit, three treatment handles (40K Cavitation, 6-Polar RF Body, 3-Polar RF Face), the bracket, and the power adapter.
  2. Assemble Bracket: Place the bracket on a stable, flat surface.
  3. Connect Handles: Identify the corresponding ports on the host unit for each treatment handle. Gently insert the connectors of the 40K Cavitation handle, 6-Polar RF Body handle, and 3-Polar RF Face handle into their respective ports. Ensure they are securely fastened.
  4. Connect Power: Plug the power adapter into the designated power input port on the host unit. Then, plug the power adapter into a suitable electrical outlet. Ensure the voltage matches the device requirements (e.g., 100-110V for US plug).
US Plug (100-110V) for the device.

Example of the US plug (100-110V) for power connection.

The device is now ready for operation. Refer to the "Product Overview" section for visual guidance on component identification.

Operating Instructions

Follow these steps for safe and effective use of your DH Beauty CS-118 device:

  1. Prepare Skin: Cleanse the target skin area thoroughly. Apply a generous amount of special gel or slimming essential oil to the skin. This ensures proper conductivity and smooth movement of the treatment head.
  2. Power On: Turn on the device using the main power switch, usually located on the side or back of the host unit. The HD display will illuminate.
  3. Select Treatment Head: Choose the appropriate treatment head (40K Cavitation, 6-Polar RF Body, or 3-Polar RF Face) based on your desired treatment area and goal.
  4. Select Mode: On the HD display, navigate through the menu to select the desired mode (e.g., Cavitation, Body RF, Eye RF, Face RF).
  5. Adjust Time: Set the treatment duration using the "TIME" controls on the display. Recommended treatment times vary by area and individual sensitivity.
  6. Adjust Power: Adjust the power level using the "POWER" controls. Start with a low power setting and gradually increase it as your comfort allows.
  7. Begin Treatment: Press the "START" button. Place the selected treatment head firmly against the prepared skin. Move the head in slow, circular motions or according to specific treatment protocols for the chosen mode.
  8. Monitor Skin: Continuously monitor the skin for any excessive redness, discomfort, or heat. Adjust power settings or stop treatment if necessary.
  9. Pause/Stop: Use the "PAUSE" button to temporarily halt treatment or "STOP" to end the session.
  10. Clean Up: After treatment, turn off the device, disconnect the power, and clean the treatment heads as described in the Maintenance section.

Application Examples:

Images showing the device being used on the face, arm, and abdomen for various treatments.

Examples of device application on different body parts.

Product Demonstration Video:

A short video demonstrating the operation and different heads of the slimming system.

Maintenance

  • Cleaning: After each use, gently wipe the treatment heads with a soft, damp cloth or cotton pad. Do not use abrasive cleaners, alcohol, or harsh disinfectants, as these can damage the probes. Ensure the probes are completely dry before storage.
  • Storage: Store the device and its components in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided bracket to safely store the treatment heads.
  • Rest Periods: To prolong the lifespan of the device, allow it to rest for 10-15 minutes after every hour of continuous use.
  • Cable Care: Avoid bending or twisting the cables excessively. Store them neatly to prevent damage.

Troubleshooting

ProblemPossible CauseSolution
Device does not power onPower cable not connected, power outlet faulty, device switch off.Check power connections, try a different outlet, ensure main switch is on.
No sensation or weak effect during treatmentInsufficient gel/oil, low power setting, poor contact with skin.Apply more gel/oil, increase power gradually, ensure full contact of the probe with skin.
Tinnitus (ringing in ears) when using 40K Cavitation headNormal phenomenon due to ultrasonic waves.This is normal and usually subsides. If uncomfortable, reduce power or take a short break.
Skin feels too hot or uncomfortablePower setting too high, not moving the probe enough, insufficient gel.Reduce power, move the probe continuously, apply more gel. Stop if discomfort persists.
Treatment head not workingHead not securely connected, faulty head.Ensure the head is firmly connected to its port. If problem persists, contact customer support.

User Tips

  • Consistency is Key: For best results, use the device regularly as recommended in the operating instructions.
  • Hydration: Drink plenty of water before and after treatments to aid in lymphatic drainage and toxin elimination.
  • Diet and Exercise: Complement your treatments with a balanced diet and regular exercise for enhanced and longer-lasting results.
  • Patch Test: Always perform a patch test on a small, inconspicuous area of skin before full treatment to check for any adverse reactions.
  • Proper Gel Application: Ensure a thick, even layer of conductive gel is applied to the skin. This is crucial for the effectiveness and safety of both cavitation and RF treatments.
  • Listen to Your Body: If you experience any pain or excessive discomfort, stop the treatment immediately.

Warranty and Support

For any questions, technical assistance, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase. Specific warranty terms and conditions may vary; please refer to the documentation provided at the time of purchase or contact customer service for details.