Introduction

The Gaqqee 9050-KLJ DC Battery Monitor Hall Coulomb Tester is a versatile instrument designed for precise measurement and monitoring of electrical parameters in DC systems. It provides real-time data on voltage, current, power, capacity, timing, and battery percentage, making it ideal for various applications including power distribution cabinets, display shelves, assembly line testing, electronic maintenance, and DIY projects.

Gaqqee 9050-KLJ DC Battery Monitor with various shunt options

Image: Gaqqee 9050-KLJ DC Battery Monitor with 50A, 100A, 300A, and 500A shunt options.

Key Features

  • Multi-parameter Display: Simultaneously shows voltage, current, power, capacity, timing, and percentage on a single screen.
  • Voltage Alarm Function: Features low/over-voltage alarm thresholds with a screen flash prompt.
  • Data Saving: Includes power-down data saving, backlight timing, low voltage setting, and capacity setting functions.
  • Calibration & Switching: Offers voltage calibration, current setting, current clearing, current calibration, and switching functions.
  • Wide Application Range: Suitable for high and low power distribution cabinets, display cabinets, assembly line testing, electronic maintenance, and DIY.

Specifications

ParameterValue
Model NumberBattery Monitor Hall Coulomb Tester (9050-KLJ)
Brand NameGaqqee
DIY SuppliesElectrical
Power SupplyDC
Display TypeAnalog-Digital
CertificationCE
Voltage Measurement RangeDC 7.5V ~ 100V
Current Measurement Range0 ~ 50A, 0 ~ 100A, 0 ~ 300A, 0 ~ 500A (depending on shunt)
Electricity Display Format (within 1kWh)0.00 ~ 1kWh
Electricity Display Format (above 1kWh)1.00 ~ 999kWh
Capacity Measurement Range0 ~ 999Ah
Timing Range0 ~ 1000 hours
Timing Display Format999.59 hours/minute
Product Size91mm * 50.5mm * 23.4mm
Product dimensions of the battery monitor and 50A shunt

Image: Detailed dimensions of the 9050-KLJ monitor and a 50A shunt.

Dimensions of 100A, 300A, and 500A shunts

Image: Dimensions for 100A, 300A, and 500A shunts.

Package Contents

Your package should contain the following items:

  • 1 x Power Meter (9050-KLJ)
  • 1 x Splitter (Shunt, current rating depends on your selection: 50A, 100A, 300A, or 500A)
  • 1 x Wiring Harness
50A Battery Monitor Kit
50A Kit
100A Battery Monitor Kit
100A Kit
300A Battery Monitor Kit
300A Kit
500A Battery Monitor Kit
500A Kit

Image: Various shunt options included in the package.

Setup and Installation

Carefully follow the wiring diagrams below to ensure correct and safe installation of your battery monitor. Incorrect wiring can damage the device or your battery system.

Terminal Description (Rear View)

Rear view of the 9050-KLJ monitor with terminal labels

Image: Rear view of the 9050-KLJ monitor showing terminal connections.

  1. RS+ (Green): Shunt positive signal input.
  2. RS- (Blue): Shunt negative signal input.
  3. B- (Black): Battery negative terminal connection.
  4. B+ (Red): Battery positive terminal connection.

Wiring Schematics

The wiring method depends on the current rating of your shunt. Ensure all connections are secure and wired according to the color coding.

Wiring schematic for 50A and 100A-500A shunts

Image: Wiring diagrams for 50A shunt connection and 100A-500A shunt connection. Note: Wires must be connected according to color.

50A Shunt Connection:

Connect the battery pack positive (B+) to the P+ (output positive) terminal. Connect the battery pack negative (B-) to the B- terminal on the shunt. The P- (output negative) terminal on the shunt connects to the load. The communication line from the shunt connects to the RS+ and RS- terminals on the meter. The B+ terminal on the meter connects directly to the battery pack positive.

100A-500A Shunt Connection:

Connect the battery pack positive (B+) to the P+ (output positive) terminal. Connect the battery pack negative (B-) to the B- terminal on the shunt. The P- (output negative) terminal on the shunt connects to the load. The communication line from the shunt connects to the RS+ and RS- terminals on the meter. The B+ terminal on the meter connects directly to the battery pack positive.

Important: Always ensure the communication line is correctly wired to the RS+ and RS- terminals, and the main power lines are connected to the shunt as shown. The B+ terminal on the meter provides power to the meter itself.

Operation

Once correctly installed and powered, the monitor will display various electrical parameters. The display is intuitive, showing voltage (V), current (A), power (W), capacity (Ah), timing (hours/minutes), and battery percentage (%).

9050 Coulometer display showing voltage, current, power, and charge

Image: The 9050-KLJ display showing real-time voltage, current, power, and charge information.

Buttons:

The device features three buttons on the right side: an 'Up' arrow, 'SET', and a 'Down' arrow.

  • SET Button: Used to enter settings menus and confirm selections.
  • Up/Down Arrows: Used to navigate through menu options and adjust values.

Functions:

  • Voltage Alarm: Set low and over-voltage thresholds. The screen will flash to alert you when these thresholds are met.
  • Power-down Data Saving: The device automatically saves data upon power loss.
  • Backlight Timing: Configure the backlight duration.
  • Low Voltage Setting: Adjust the low voltage cutoff point.
  • Capacity Setting: Manually set the total battery capacity (Ah) for accurate percentage calculation.
  • Voltage/Current Calibration: Allows for fine-tuning of voltage and current readings for improved accuracy.
  • Current Clearing: Resets the current accumulation.
  • Switching Function: Refer to the detailed PDF manual for specific switching functionalities.

Maintenance

  • Cleaning: Use a soft, dry cloth to clean the display and casing. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a dry, cool environment away from direct sunlight and extreme temperatures.
  • Connections: Periodically check all wiring connections to ensure they are secure and free from corrosion.

Troubleshooting

  • No Display: Check power connections (B+ and B- on the meter). Ensure the DC input voltage is within the 7.5V-100V range.
  • Incorrect Readings: Verify shunt connections (RS+ and RS-). Perform voltage and current calibration if necessary. Ensure the capacity setting is correct for your battery.
  • Alarm Triggering: Check your set low/over-voltage alarm thresholds.
  • Data Loss: The device has power-down data saving. If data is lost, ensure stable power supply during operation.

For more detailed troubleshooting steps or complex issues, please refer to the comprehensive user manual available in PDF format.

User Tips

  • The signal cable for the shunt may be short. Consider purchasing or making an extension if your installation requires the monitor to be further from the shunt.
  • The power cable provided might be thin and long. Ensure it is suitable for your specific application and does not introduce excessive voltage drop, especially if used for powering other components.
  • When connecting to 2x12V 180Ah batteries to achieve a 12V 360Ah bank, ensure proper parallel connection. Select an appropriate current shunt (e.g., 300A or 500A) based on your maximum expected current draw to avoid overloading the shunt.

Frequently Asked Questions (FAQ)

Q: What size shunt do I need for 2*12 Volt 180 Ah batteries converted to 12 Volt 360 Ah?
A: You would need to select a shunt based on the maximum current draw of your system. For a 360Ah battery bank, common shunts are 50A, 100A, 300A, or 500A. Choose one that exceeds your expected peak current to ensure accurate measurement and prevent damage.
Q: In which language is the user manual?
A: The primary language for this manual is English. A more detailed PDF version is available for download, which may include additional language options or more in-depth instructions.

Support and Additional Resources

For further assistance, detailed technical specifications, or advanced configuration options, please refer to the official user manual PDF:

Download User Manual (PDF)

You can also watch the product overview video for a visual guide:

Play video
Watch video online

Video: Product overview and demonstration of the Gaqqee 9050-KLJ DC Battery Monitor.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.