ZOYI ZT-225

Contents

ZOYI ZT-225 Digital Multimeter User Manual

Model: ZT-225

1. Introduction

This product is a battery-powered, true-RMS, auto-ranging digital multimeter with a 25000 counts LCD display and a backlight. It is designed for professional measurements and is suitable for home repair, electrician work, car circuit testing, and electronics DIY projects.

The ZOYI ZT-225 offers high-precision measurements for AC/DC voltage, current, resistance, capacitance, frequency, continuity, diodes, and temperature. Its auto-range and anti-burn design make it easy for beginners and reliable for professionals.

2. Safety Information

To avoid possible electrical shock, fire, or personal injury, please read all safety information before using the product. Use the product only as specified; otherwise, the protection supplied by the product can be compromised.

  • Examine the case before use. Look for cracks or missing plastic. Carefully inspect the insulation around the terminals.
  • Measurements must be made with correct input terminals and functions, and within the allowable measuring range.
  • Do not use the product around explosive gas, vapor, or in damp or wet environments.
  • Keep fingers behind the finger guards on the probes.
  • When the product is connected to the line being measured, do NOT touch any input terminal that is not in service.
  • Disconnect the test leads from the circuit before changing the mode.
  • When the voltage to be measured exceeds 36V DC or 25V AC, exercise extreme caution to avoid electric shock.
  • Misuse of mode or range can lead to hazards. "OL" will be shown on the display when the input is out of range.
  • A low battery level will result in incorrect readings. Replace the batteries when the battery level is low. Do not make measurements when the battery door is not properly placed.

3. Instrument Overview

3.1. LCD Display

The ZOYI ZT-225 features a large LCD screen with triple display, providing clear readings even in low light environments. It has a 25000-count display, offering high precision.

ZOYI ZT-225 Multimeter with large screen triple display
Figure 1: ZOYI ZT-225 Multimeter with large screen triple display, showing various measurement data.
Close-up of ZOYI ZT-225 LCD display
Figure 2: Close-up of the ZOYI ZT-225 LCD display, highlighting the 25000 count and T-RMS indication.
LCD Display Indicators
SymbolDescription
HOLDDisplay freezes present reading.
+Diode test.
)))Continuity test.
RELRelative value test.
MAXDisplay shows maximum reading.
MINDisplay shows minimum reading.
°F °CTemperature test (Fahrenheit/Celsius).
%Duty cycle test.
ΩResistance test (Ohm).
HzFrequency test (Hertz).
8.8.8.8Secondary measurements display.
AUTOAuto range. The product selects the range with the best resolution.
AC+DCAC + DC.
T-RMSThe product can accurately measure alternating current with and without sinusoidal waveforms.
Battery IconLow battery. Replace batteries.
ACAlternating current.
DCDirect current.
Analog Bar GraphAnalog bar graph.
Auto Power Off IconAuto power off.
8.8.8.8.8Main display.
VOLTAGE INPUT FORBIDDENDon't input voltage reminder.
nkMmMeasurement units.

3.2. Function Buttons

ZOYI ZT-225 Multimeter front panel with buttons
Figure 3: Front panel of the ZOYI ZT-225 Multimeter, showing the function buttons.
  • SEL/REL Button: Selects alternate measurement modes on a rotary switch setting, including Frequency/Duty Cycle, DC mA / AC mA, DC μA / AC μA, DC A / AC A, Diode / Continuity, DC mV / AC mV, AC+DC Voltage / DC Voltage. Press and hold for 2 seconds to enter REL mode; press again to exit.
  • HOLD Button: Push once to hold the current reading on the display; push again to continue normal operation. Push for more than 2 seconds to turn on the backlight; long-push again to turn off or the backlight automatically turns off after 2 minutes.
  • MAX/MIN Button: Push to toggle between the MAX and the MIN mode. To exit MAX/MIN mode, push the button for more than 2 seconds.
  • RANGE Button: Press to enter the manual range mode, allowing you to choose the appropriate range according to the measured signal size. To exit, hold down the button for more than 2 seconds; the screen will display "AUTO".

3.3. Rotary Switch

The rotary switch is used to select the desired measurement function.

ZOYI ZT-225 Multimeter rotary switch
Figure 4: Rotary switch for function selection.
  • OFF Position: Turns off the product. The product automatically powers off after 15 minutes of inactivity. The built-in beeper beeps 5 times 1 minute before auto power off. To restart, press SELECT or turn the rotary switch back to OFF and then to a needed position. To disable Auto Power Off, hold down SELECT when turning on the product; you will hear four beeps if successfully disabled.
  • Measurement Functions: The rotary switch allows selection of various measurement modes including AC/DC Voltage, Resistance, AC/DC Current, Capacitance, Frequency, Duty Cycle, Temperature, Diode, Continuity, and NCV (Non-Contact Voltage).

3.4. Input Terminals

ZOYI ZT-225 Multimeter input terminals
Figure 5: Input terminals of the ZOYI ZT-225 Multimeter.
Input Terminal Descriptions
TerminalDescription
20AInput terminal for AC/DC current measurements up to 20A.
mA μAInput port for current measurement mA/μA (mA ≤ 250mA, μA ≤ 2500μA).
COMCommon (return) terminal for all measurements.
VΩHz-Input terminal for measurements of: AC/DC voltage, Resistance, Capacitance, Frequency, Temperature, Continuity, Diode, Duty cycle.

4. Operating Instructions

4.1. Measure AC/DC Voltage

  1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz- Terminal.
  2. Rotate the dial to select the corresponding voltage gear. Press the RANGE button to enter manual range mode, and press the SEL button to switch AC/DC in mV mode.
  3. Touch the probes to the correct test points of the circuit to measure the voltage.
  4. Read the measured voltage on the display.

*Do not measure voltage that exceeds the extremes as indicated in the Specifications.

*Do not touch high voltage circuits during measurements.

Video 1: Demonstration of measuring AC voltage with the ZOYI ZT-225 Multimeter.
Measuring AC voltage with ZOYI ZT-225
Figure 6: Example of AC voltage measurement using the multimeter on a wall socket.
Measuring DC voltage with ZOYI ZT-225
Figure 7: Example of DC voltage measurement using the multimeter on a battery.

4.2. Measure AC/DC Current

  1. Connect the black test lead to the COM Terminal and the red lead to the corresponding terminal (20A or mAμA).
  2. Point the arrow on the knob to the AC/DC A, mA, or μA range, depending on the signal size.
  3. Break the circuit path to be measured, connect the test leads across the break, and apply power.
  4. Read the measured current on the display.

*Do not measure current that exceeds the extremes as indicated in the Specifications.

*Use the 20A Terminal when measuring an unknown current. Then select the test port and gear according to the displayed value.

*Do not input voltage at this setting.

Current range misoperation prompt on ZOYI ZT-225
Figure 8: The current range has a misoperation prompt with a constant light on the current jack indicator, reminding users of potential errors. The screen also provides additional prompts.

4.3. Measure Resistance

  1. Connect the black test lead to the COM Terminal and the red test lead to the VΩHz- Terminal.
  2. Rotate the dial to the Ω mode.
  3. Touch the probes to the desired test points of the circuit to measure the resistance.
  4. Read the measured resistance on the display.

*Disconnect circuit power and discharge all capacitors before you test resistance.

*Do not input voltage at this setting.

Measuring resistance with ZOYI ZT-225
Figure 9: Example of resistance measurement using the multimeter.

4.4. Test for Continuity

  1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz- Terminal.
  2. Turn the rotary switch to Diode/Continuity mode, then press the SEL button.
  3. Touch the probes to the desired test points of the circuit.
  4. The built-in beeper will beep when the resistance is lower than 50Ω, indicating a short circuit.

*Do not input voltage at this setting.

Testing continuity with ZOYI ZT-225
Figure 10: Example of continuity testing using the multimeter.

4.5. Test Diodes

  1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz- Terminal.
  2. Turn the rotary switch to Diode mode.
  3. Connect the red probe to the anode side and the black probe to the cathode side of the diode being tested.
  4. Read the forward bias voltage value on the display.
  5. If the polarity of the test leads is reversed with diode polarity or the diode is broken, the display reading shows "OL".

*Do not input voltage at this setting.

*Disconnect circuit power and discharge all capacitors before you test diodes.

4.6. Measure Capacitance

  1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz- Terminal.
  2. Turn the rotary switch to the Capacitance mode (indicated by the capacitor symbol).
  3. Connect the red probe to the anode side and the black probe to the cathode side of the capacitor being tested.
  4. Read the measured capacitance value on the display once the reading is stabilized.

*Disconnect circuit power and discharge all capacitors before you test capacitance.

Measuring capacitance with ZOYI ZT-225
Figure 11: Example of capacitance measurement using the multimeter.

4.7. Measure Frequency

  1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz- Terminal.
  2. Turn the rotary switch to Hz% (applies to high frequency with low voltage); or turn the rotary switch to the VΩHz- position, then press SELECT once to toggle to the Frequency Mode (applies to low frequency with high voltage).
  3. Touch the probes to the desired test points.
  4. Read the measured frequency value on the display.

*Do not input voltage at this setting.

4.8. Measure Duty Cycle

  1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz- Terminal.
  2. Turn the rotary switch to Hz%, then press the Hz % button once to toggle to the Duty Cycle Mode.
  3. Touch the probes to the desired test points.
  4. Read the measured duty cycle value on the display.

*Do not input voltage at this setting.

4.9. Measure Temperature

  1. Connect the black thermocouple probe to the COM Terminal and the red probe to the VΩHz- Terminal.
  2. Turn the rotary switch to °C/°F mode; the main display will show the value in °C, and the secondary display will show the value in °F.
  3. Touch the probes to the desired test points.
  4. Read the measured temperature on the display.

*Do not input voltage at this setting.

Measuring temperature with ZOYI ZT-225
Figure 12: Example of temperature measurement using the multimeter.

4.10. Test NCV (Non-Contact Voltage)

  1. Turn the rotary switch to NCV mode; the display will show "EF".
  2. Hold the product and move it around; the built-in beeper will beep when the inner sensor detects AC voltage nearby. The stronger the voltage, the quicker the beeper beeps.
  3. If the red test lead is inserted into the VΩHz- terminal alone, and the probe is used to contact the mains power plug, if the buzzer alarm is strong, it indicates the live wire; otherwise, it is the earth wire or the neutral wire.
Non-contact voltage detection with ZOYI ZT-225
Figure 13: Non-contact voltage detection in action, showing the multimeter near an electrical outlet.

4.11. AC+DC Voltage Measurement

  1. Rotate the dial to the AC+DC V mode, then connect the black test lead to the COM Terminal and the red lead to the VΩHz- Terminal.
  2. Touch the probes to the correct test points of the circuit.
  3. Read the measured voltage on the display. The main display will show the value of DC voltage, and the secondary display will show the value of AC voltage.
  4. Press the SEL button to read the value of AC+DC Voltage.

*Do not measure voltage that exceeds the extremes as indicated in the Specifications.

*Do not touch high voltage circuits during measurements.

5. Maintenance

Beyond replacing batteries and fuses, do not attempt to repair or service the product unless you are qualified to do so and have the relevant calibration, performance test, and service instructions.

5.1. Clean the Product

Wipe the product with a damp cloth and mild detergent. Do not use abrasives or solvents. Dirt or moisture in the terminals can affect readings.

*Remove the input signals before you clean the product.

5.2. Replace the Batteries

When the battery icon is shown on the display, batteries shall be replaced as follows:

  1. Remove the test leads and turn off the product before replacing the batteries.
  2. Loosen the screw on the battery door and remove the battery door.
  3. Replace the used batteries with new batteries of the same type (3 x 1.5V AA Battery).
  4. Place the battery door back and fasten the screw.

5.3. Replace the Fuses

When a fuse is blown or does not work properly, it shall be replaced as follows:

  1. Remove the test leads and turn off the product before replacing the fuse.
  2. Loosen the four screws on the back cover and the screw on the battery door, then remove the battery door and the back cover.
  3. Replace the fuse with a new fuse of the same type.
  4. Place the back cover and the battery door back and fasten the screws.

6. Specifications

6.1. General Specifications

FeatureSpecification
Display (LCD)25000 counts
RangingAuto/Manual
MaterialABS/PVC
Update Rate3 times/second
True RMSYes
Data HoldYes
BacklightYes
Low Battery IndicationYes
Auto Power OffYes (after 15 minutes of inactivity)

6.2. Mechanical Specifications

FeatureSpecification
Dimension180*90*50mm
Weight384g (no battery)
Battery Type3 x 1.5V AA Battery
ZOYI ZT-225 Multimeter product dimensions
Figure 14: ZOYI ZT-225 Multimeter showing its dimensions (180mm height).

6.3. Environmental Specifications

ConditionTemperatureHumidity
Operating0~40°C< 75%
Storage-20~60°C< 80%

6.4. Electrical Specifications

FunctionRangeResolutionAccuracy
DC Voltage (mV)25.000mV0.001mV±(0.05%+3)
250.00mV0.01mV
2.5000V0.0001V
DC Voltage (V)25.000V0.001V±(0.05%+3)
250.00V0.01V
1000.0V0.1V
AC Voltage (mV)25.000mV0.001mV±(0.3%+3)
250.00mV0.01mV
2.5000V0.0001V
AC Voltage (V)25.000V0.001V
250.00V0.01V
750.0V0.1V
AC+DC Voltage (DC)2.5000V0.0001V±(0.5%+3)
25.000V0.001V
250.00V0.01V
1000.0V0.1V
AC+DC Voltage (AC)2.500V0.001V±(1.0%+3)
25.00V0.01V
250.0V0.1V
750V1V
AC+DC Voltage (AC+DC)2.5000V0.0001V±(1.5%+3)
25.000V0.001V
250.00V0.01V
1000.0V0.1V
DC Current (A)2.5000A0.0001A±(0.5%+3)
20.000A0.001A
DC Current (mA)25.000mA0.001mA
250.00mA0.01mA
DC Current (μA)250.00μA0.01μA
2500.0μA0.1μA
AC Current (A)2.5000A0.0001A±(0.8%+3)
20.000A0.001A
AC Current (mA)25.000mA0.001mA
250.00mA0.01mA
AC Current (μA)250.00μA0.01μA
2500.0μA0.1μA
Resistance250.00Ω0.01Ω±(0.5%+3)
2.5000kΩ0.0001kΩ±(0.2%+3)
25.000kΩ0.001kΩ
250.00kΩ0.01kΩ
2.5000MΩ0.0001MΩ±(1.0%+3)
25.00MΩ0.01MΩ
250.0MΩ0.1MΩ±(5%+5)
Capacitance9.999nF0.001nF±(5.0%+20)
99.99nF0.01nF±(2.0%+5)
999.9nF0.1nF
9.999μF0.001μF
99.99μF0.01μF±(5.0%+5)
999.9μF0.1μF
9.999mF0.001mF±(5.0%+20)
99.99mF0.01mF
Frequency250.00Hz0.01Hz±(0.1%+2)
2.5000KHz0.0001KHz
25.000KHz0.001KHz
250.00KHz0.01KHz
2.5000MHz0.0001MHz
10.000MHz0.001MHz
Duty Cycle1%~99%0.1%±(0.1%+2)
Temperature-20~1000°C (-4~1832°F)1°C (1°F)±(3%+5)
DiodeYes
ContinuityYes
NCVYes
AC+DC Voltage Measurement1V~1000V

7. Warranty & Support

7.1. Limited Warranty and Limitation of Liability

Customers enjoy a one-year warranty from the date of purchase.

This warranty does not cover fuses, disposable batteries, damage from misuse, accident, neglect, alteration, contamination, or abnormal conditions of operation or handling, including failures caused by use outside of the product's specifications, or normal wear and tear of mechanical components.

For support or warranty claims, please contact your retailer or the manufacturer directly.

8. User Tips

  • The "Rel" (Relative Value) function is highly useful for component selection, allowing you to measure the difference from a reference value.
  • Consider replacing the standard test leads with higher quality, possibly gold-plated, ones for improved contact and accuracy, especially if you notice fluctuations in measurements.
  • While the backlight is good, note that it turns on simultaneously with the flashlight. If you only need the backlight, be aware the flashlight will also activate.
  • Ensure you have 3 AA 1.5V batteries on hand, as they are required for operation and may not be included with the product. Some users have noted that certain battery brands might be a tight fit in the battery compartment.
  • Always compare readings with other known accurate multimeters if precision is critical for your application, especially for advanced tests.
  • The robust body design provides good protection against drops, making it suitable for workshop environments.

All rights reserved. Specification are subject to change without notice.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.