1. Introduction
The Jikong JK-BD4A20S4P is a smart Battery Management System (BMS) designed for 4S to 20S battery packs, supporting Li-ion, LiFePO4, and LTO chemistries. It features a 40A continuous charge/discharge current, 0.4A active balancing, and Bluetooth connectivity for real-time monitoring and control via a dedicated mobile application. This manual provides essential information for the safe and effective installation, operation, and maintenance of your Smart BMS.

Figure 1: Jikong JK-BD4A20S4P Smart BMS with wiring harness.
2. Safety Instructions
Always observe the following safety precautions to prevent injury or damage to the BMS and battery pack:
- Ensure all connections are correct and secure before applying power. Incorrect wiring can cause severe damage.
- Do not short-circuit the battery terminals.
- Operate the BMS within its specified voltage and current limits.
- Avoid exposing the BMS to water, moisture, or extreme temperatures outside its operating range.
- Only qualified personnel should perform installation and maintenance.
- Verify battery cell count (S-count) matches the BMS configuration.
3. Setup and Installation
3.1 Component Overview

Figure 2: Front view of the BMS showing main terminals and balance port.
3.2 Wiring Diagram
Follow the detailed wiring diagram carefully. Incorrect connections can lead to permanent damage to the BMS or battery pack. Ensure all balance wires are connected in the correct order, starting from B0 (negative terminal of the first cell) up to the highest cell voltage.

Figure 3: Comprehensive wiring diagram for the Jikong Smart BMS. Connect B- to the battery pack's main negative terminal. Connect P- to the negative terminal of both the charger and the load. The balance wires (B0, B1, B2...Bn) must be connected sequentially to each cell's positive terminal, starting with B0 to the negative of the first cell (or positive of the cell before the first cell if B0 is considered the pack negative).
3.3 Initial Connection Steps
- Connect the main negative wire (B-) from the BMS to the negative terminal of your battery pack.
- Connect the balance wires: Start with B0 (often the main negative of the pack) and connect each subsequent wire (B1, B2, etc.) to the positive terminal of each cell in series. Ensure the order is correct for your specific cell count (up to 20S).
- Connect the main negative output wire (P-) from the BMS to the negative terminals of your charger and load.
- Double-check all connections before applying power.
4. Operating Instructions
4.1 Bluetooth APP Connection
The Jikong Smart BMS supports Bluetooth connectivity for monitoring and control. To download the official APP and user manual, scan the QR code located on the BMS unit or visit WWW.JK-BMS.COM.

Figure 4: BMS unit displaying QR code for APP download and website.
4.2 APP Functions
The mobile application allows you to:
- Monitor real-time battery parameters (voltage, current, temperature, cell balance).
- View battery status and cycle count.
- Adjust protection parameters (overcharge, over-discharge, overcurrent, temperature).
- Control charging and discharging functions.
- Initiate active balancing.

Figure 5: Screenshots of the BMS APP interface, showing STATUS, SETTINGS, and CONTROL tabs with various parameters.
4.3 Active Balancing
The BMS features 0.4A active balancing, which transfers energy from higher voltage cells to lower voltage cells. This process helps to equalize cell voltages, extending the overall lifespan and performance of the battery pack.

Figure 6: Active Balance concept: Energy transfer from high voltage to low voltage cells to extend battery life.
5. Specifications
5.1 General Specifications
| Serial Number | Project | Argument | Unit |
|---|---|---|---|
| 1 | Supply voltage | 20-100 | V |
| 2 | Operating power consumption | ≤800 | mW |
| 3 | Operating temperature | -30-70 | °C |
| 4 | Maximum number of collection strings | 20S | (String) |
| 5 | Maximum balancing current | 0.4 | A |
| 6 | Maximum charging current | 40 | A |
| 7 | Maximum discharge current | 40 | A |
| 8 | Maximum instantaneous current | 80 | A |
| 9 | Maximum internal loop resistance | 2.8 | mΩ |
| 10 | Protective plate size | 116*83*17.6 | mm |
Table 1: General Specifications of the Jikong Smart BMS.
5.2 Detailed Protection Parameters
| NUM | PARA | LI-ION | LIFEPO4 | LTO | Unit |
|---|---|---|---|---|---|
| 1 | Balancing initial voltage | 3 | 2 | 3 | V |
| 2 | Maximum balancing current | 0.4 | 0.4 | 0.4 | A |
| 3 | Unit overcharge voltage | 4.2 | 3.6 | 2.7 | V |
| 4 | Single overcharge protection recovery | 4.18 | 3.55 | 2.65 | V |
| 5 | Monomer undervoltage protection | 2.82 | 2.6 | 1.8 | V |
| 6 | Single undervoltage protection recovery | 2.85 | 2.65 | 1.85 | V |
| 7 | Automatic shutdown voltage | 2.8 | 2.5 | 1.7 | V |
| 8 | SOC-0% voltage | 2.9 | 2.6 | 1.85 | V |
| 9 | SOC-100% voltage | 4.18 | 3.5 | 2.65 | V |
| 10 | Trigger balancing differential pressure | 0.01 | 0.01 | 0.01 | V |
| 11 | Charging overcurrent protection delay | 30 | 30 | 30 | S |
| 12 | Charging overcurrent protection release time | 60 | 60 | 60 | S |
| 13 | Discharge overcurrent protection delay | 300 | 300 | 300 | S |
| 14 | Discharge overcurrent protection release time | 60 | 60 | 60 | S |
| 15 | Short-circuit protection delay | 1500 | 1500 | 1500 | µS |
| 16 | Short circuit protection release time | 60 | 60 | 60 | S |
| 17 | Charging overtemperature protection temperature | 70 | 70 | 70 | °C |
| 18 | Charge overtemperature restore temperature | 60 | 60 | 60 | °C |
| 19 | Discharge overtemperature protection temperature | 70 | 70 | 70 | °C |
| 20 | Discharge overtemperature recovery temperature | 60 | 60 | 60 | °C |
| 21 | Charging low temperature protection temperature | -20 | -20 | -20 | °C |
| 22 | Charge low temperature to restore temperature | -10 | -10 | -10 | °C |
| 23 | MOS Overtemperature protection temperature | 100 | 100 | 100 | °C |
| 24 | MOS Overtemperature recovery temperature | 80 | 80 | 80 | °C |
Table 2: Detailed Protection Parameters for various battery chemistries.
5.3 Physical Dimensions

Figure 7: Dimensional drawing of the BMS (dimensions in mm).
6. Maintenance
The Jikong Smart BMS is designed for reliable operation with minimal maintenance. However, regular checks can ensure optimal performance and longevity:
- Visual Inspection: Periodically inspect the BMS and wiring for any signs of damage, corrosion, or loose connections.
- Firmware Updates: Check the official website or APP for any available firmware updates to ensure you have the latest features and bug fixes.
- Cleanliness: Keep the BMS free from dust and debris. Use a soft, dry cloth for cleaning.
- Environmental Conditions: Ensure the BMS operates within its specified temperature and humidity ranges.
7. Troubleshooting
If you encounter issues with your Jikong Smart BMS, consider the following common troubleshooting steps:
- No Power/No Output:
- Check all main power connections (B-, P-) for secure contact.
- Verify the battery pack voltage is within the BMS's operating range.
- Ensure balance wires are correctly connected and not loose.
- Check for any active protection triggers (e.g., over-discharge, overcurrent) via the APP.
- Balancing Issues:
- Confirm all balance wires are connected to the correct cell terminals.
- Check individual cell voltages via the APP; significant discrepancies might indicate a faulty cell or connection.
- Ensure the active balancing function is enabled in the APP settings.
- Bluetooth Connectivity Problems:
- Ensure the BMS is powered on.
- Verify Bluetooth is enabled on your mobile device.
- Try restarting the APP or your mobile device.
- Ensure your device is within range of the BMS.
- Over-temperature Protection:
- Check the ambient temperature and ensure adequate ventilation for the battery pack and BMS.
- Reduce load or charging current if temperatures are consistently high.
For persistent issues, refer to the detailed manual available on WWW.JK-BMS.COM or contact customer support.
8. User Tips
- Initial Charge: After installation, perform a full charge cycle to allow the BMS to properly balance all cells and calibrate its readings.
- Regular Monitoring: Use the Bluetooth APP regularly to monitor cell voltages and temperatures, especially during the first few charge/discharge cycles, to ensure stable operation.
- Parameter Customization: Adjust the protection parameters in the APP to match the specific requirements and safety limits of your battery cells for optimal performance and longevity.
- Wiring Quality: Always use high-quality wires and connectors for main power and balance leads to minimize resistance and ensure reliable data transmission.
9. Warranty and Support
This Jikong Smart BMS is manufactured by Jikong Bms Factory Store. For warranty information, technical support, or service inquiries, please refer to the official website WWW.JK-BMS.COM or contact the seller directly through your purchase platform.