1. Introduction
Thank you for choosing the GAIN EXPRESS SLM-390 Professional Digital Sound Level Meter. This manual provides essential information to help you operate and maintain your device correctly. Please read it carefully before use.
For more detailed instructions and comprehensive information, please refer to the complete user manual available as a PDF document.
2. Product Overview
The SLM-390 is an advanced digital sound level meter designed for professional sound analysis. It features a wide measuring range of 30 to 130 dB and offers A, C, and Z frequency weighting options, along with FAST and SLOW time-weighted settings for precise sound characterization in various scenarios.
Video: Product demonstration and feature overview of the SLM-390 Sound Level Meter.

Figure 2.1: SLM-390 Digital Sound Level Meter highlighting high precision 1/2 inch microphone, A/C/Z analog signal output, FAST/SLOW time-weighted options, limit buzzer and light alarm, and data record/PC connection.

Figure 2.2: Sound Level Meter with Data Logging, featuring a large colored display, wide measurement range (30~130dB), A/C/Z frequency and time weight options, and buzzer/light alarm.

Figure 2.3: Detailed diagram of the SLM-390 meter, showing the sensor with detachable sponge ball, light alarm indicator, power button, record button, Max/Min/AVG/Down button, Hold/Menu button, tripod mounting hole, battery compartment, USB port, range button, Fast/Slow button, and Frequency/Temperature/Up button.

Figure 2.4: Features including the tripod socket, large and easy-to-read colored LCD, and audio/visual alarm that triggers when exceeding set limits.
3. Setup
3.1. Battery Installation
The SLM-390 is powered by 3 x 1.5V AAA batteries or via a USB micro interface (5V). When the battery level is low, an empty battery icon will appear on the display, indicating that the batteries need to be replaced.
- Remove the battery compartment cover.
- Replace the old 3 AAA batteries with new ones.
- Pay close attention to the battery polarity when placing the new batteries into the compartment.
- Make sure to fasten the compartment cover securely after replacing.
3.2. PC Software Installation & Time Synchronization
To ensure accurate timestamping of recorded data, synchronize the device's clock via the PC software.
- Download and install the free Environmental Tester software from the QR code or URL: www.cd50.net/m390/.
- Launch the software and connect the decibel meter to the computer using the provided USB cable. The software interface should display "Connected".
- Click the "Sync" button in the software to synchronize the current time.

Figure 3.1: Software interface for displaying and exporting real-time data sheets and charts. The meter can log up to 1999 groups of data.

Figure 3.2: The sound level meter packaged with batteries, USB cable for power and PC connection, and a carrying pouch.
4. Operating Instructions
4.1. Power On/Off
- Press the Power button to turn the meter on or off.
- When powered via USB, manual shutdown is not possible.
4.2. Measurement Modes
The SLM-390 offers various settings to tailor measurements to your specific needs.
- Frequency Weighting (A/C/Z): Press the A/C button to cycle through A, C, and Z weighting modes.
- Time Weighting (FAST/SLOW): Press the Fast/Slow button to switch between FAST (0.125s/time for environmental measurements with large variation) and SLOW (1s/time for general environmental measurements).
- MAX/MIN/AVG Mode: Press the MAX/AVG/MIN button to cycle through and display maximum, minimum, or average values in the sub-window.
- Analog Bar Scale: The analog bar scale provides a real-time visual representation of sound levels, with one scale representing 1dB.

Figure 4.1: Demonstrates A weighting (environmental noise), C weighting (sound pressure analysis of engines), and Z weighting (horizontal response to 20Hz-20KHz frequency range).

Figure 4.2: Explains FAST (0.125s/time) and SLOW (1s/time) time weighting, and A, C, Z frequency weighting options.

Figure 4.3: Illustrates the audible and visual alarm (light indicator flashes, sound beeps) and the analog bar scale showing 'UNDER', 'HOLD', 'OVER' states.
4.3. Setting Alarms (Hi/Lo Limits)
The meter allows you to set upper (Hi) and lower (Lo) limits for sound levels. If the measured sound exceeds these limits, an audible and visual alarm will trigger.
- Under measurement mode, press and hold the HOLD/MODE button to enter the setting mode.
- Use the MAX/AVG/MIN or A/C buttons to adjust the Hi limit alarm value (default 130dB). Press HOLD/MODE to confirm.
- Adjust the Lo limit alarm value (default 30dB) using the MAX/AVG/MIN or A/C buttons. Press HOLD/MODE to confirm.
4.4. Data Logging
The SLM-390 supports both on-meter data logging and real-time PC connection for data analysis.
- On-Meter Logging: Long press the REC button for 2 seconds to start/stop recording. The REC symbol will flash during recording. You can set the recording interval (1s, 5s, 10s, 30s, 1min, 30min, 1h, 12h, 24h) in the setting mode.
- PC Software Logging: Connect the meter to your PC with the software running. You can configure parameters like sampling rate (1s, 2s, 5s, 10s, 30s, 60s, 30min, 1h) via the software's menu. Click "Start/pause" to begin real-time recording. Data can be uploaded from the meter to the software and exported in .bpm/.table format.

Figure 4.4: Software interface for displaying and exporting real-time data sheets and charts, and logging up to 1999 groups of data.
4.5. Changing Temperature Unit
Long press the A/C / °C/°F button to switch between Celsius (°C) and Fahrenheit (°F) temperature units.
4.6. Auto Power Off
The auto power off function is enabled by default (APO symbol displayed) and activates after 15 minutes of inactivity. To disable it, press and hold the Power button, then simultaneously press the REC button until the APO OFF icon appears. The APO symbol will disappear. The auto power off function will restore upon restarting the meter.
5. Specifications
| Feature | Specification |
|---|---|
| Microphone | High precision 1/2 inch microphone |
| Measurement Range | 30 ~ 130 dB |
| Measuring Level | 30~70dB, 60~90dB, 80~110dB, 100~130dB |
| Resolution | 0.1dB |
| Accuracy | ±1.5dB (sound pressure reference, 94dB@1KHz) |
| Frequency Weighting | A/C/Z weighting |
| Time Weighting (Fast) | 0.125s |
| Time Weighting (Slow) | 1s |
| Sampling Rate | 2 times/s |
| Frequency Response | 31.5Hz ~ 8kHz |
| Analog Bar | One scale represents 1dB |
| Display | 4 digits, max 1999 |
| Ambient Temperature Range | 0 ~ 60°C |
| Ambient Temperature Accuracy | ±2°C |
| Over Range Indication | "OVER~HI", "UNDER~LO" |
| Datalogger | 1999 groups |
| Record Interval Adjustment | 9 levels (1s, 5s, 10s, 30s, 1min, 30min, 1h, 12h, 24h) |
| Synchronous Update | Refer to PC information for program update |
| Auto Power Off | 15 mins (can be canceled) |
| Working Environment | -10~50°C, max 80%RH, indoor altitude <2000m |
| Storage Environment | -10~50°C, max 70%RH (battery removed) |
| Product Size | 229 x 70 x 35mm |
| Screen Size | 53 x 44mm |
| Weight | Approx. 215g (battery not included) |
| Power Supply | 3 x 1.5V AAA battery or USB micro interface 5V |
6. Maintenance
- Avoid prolonged measurements in high-temperature, high-humidity conditions.
- Remove the battery if the device will not be used for an extended period.
- Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning.
7. Troubleshooting
- Device does not turn on:
- Check if the batteries are installed correctly with the right polarity. Ensure batteries have sufficient charge. If using USB power, verify the connection.
- Inaccurate readings:
- Ensure the microphone is not obstructed. Check for environmental factors like strong winds or vibrations. Verify the correct frequency and time weighting settings for your application. Consider recalibrating if readings are consistently off.
- PC software connection issues:
- Ensure the USB cable is securely connected to both the meter and the computer. Verify that the software is correctly installed and running. Check if the meter's display shows "Connected" in the software interface.
- Data logging not working:
- Ensure the meter's clock is synchronized with the PC. Check the recording interval settings. Make sure there is sufficient memory for logging.
8. User Tips
To get the most accurate and useful measurements from your sound level meter, consider the following:
- Understand Noise Levels: Familiarize yourself with typical sound levels for various environments to better interpret your readings.
- Choose the Right Weighting: Use A-weighting for general environmental noise, C-weighting for mechanical noise, and Z-weighting for a flat frequency response.
- Regular Synchronization: Always synchronize the meter's clock with your PC before logging data to ensure accurate timestamps.

Figure 8.1: Illustrates various sound levels and their potential impact, highlighting the safe exposure limit of 85dB for eight hours a day.

Figure 8.2: Sound Level Index providing a quick reference for different noise categories based on decibel ranges, from silence to hearing loss.
9. Warranty & Support
9.1. Warranty Information
A 12-month Seller's Limited Warranty is provided for defective items (excluding items damaged or misused after receipt). Accessories come with a 3-month warranty.
Defective items MUST be reported and returned within the warranty period (in the original packaging). You must provide details of the defect and your order number. Items with an expired warranty will not be replaced. Repairs and free technical support will still be available even after expiration, though parts to be replaced will be charged to the buyer.
9.2. Technical Support
If you encounter any issues or have questions regarding the operation or maintenance of your SLM-390 Digital Sound Level Meter, please contact the seller for technical assistance.
