1. Product Overview
This RATTMMOTOR spindle is a built-in type spindle motor featuring three asynchronous motors, controlled by an inverter. It boasts a compact structure, high power, significant torque, minimal vibration, and low noise. These characteristics enable high-speed, high-power cutting with high precision and stability, making it ideal for various CNC applications.
Key Features:
- Bearings: Utilizes grease-lubricated angular contact bearings designed for lifelong lubrication.
- Cooling System: Employs a forced cooling mode for the motor and bearings. Coolant flows through a precisely arranged watercourse within the spindle body, ensuring thermal equilibrium and maintaining the spindle temperature within a constant range (24-28°C). An external cooling device is required to maintain a constant coolant temperature.
- Temperature Sensor: Equipped with a built-in PTC 140 temperature sensor for continuous monitoring and protection of motor temperature.
- Tool Clamping: Features an automatic tool change device with an ISO20 shank form.
Video: RATTMMOTOR Spindle Product Overview
2. Specifications
Spindle Motor (Model: RTM80-20-24Z/2.2 220V)
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Model | RTM80-20-24Z/2.2 220V | Voltage | 220V |
| Power | 2.2KW (S1) | Peak Power | 2.2KW (S6) |
| Electric Current | 5.4A | Rated Frequency | 400Hz |
| Maximum Speed | 24000rpm | Motor Level | Level 2 |
| Rated Torque | 0.59Nm | Peak Torque | 0.84Nm |
| Spindle Diameter | 80mm | Tool Interface | ISO20 |
| Application | Milling (castings, aluminum, glass, etc.) | Certification | CE |
Technical Parameters (General)
| Parameter | Value |
|---|---|
| Spindle blowing dust/seal gas pressure | 0.2-0.25 MPa |
| Spindle gas seal gas flow | 65±10 L/min (When working) |
| Cooling water pressure | ≥0.25 MPa |
| Cooling water flow | ≥2.5 L/min |
| Cooling water temperature | 24-28°C |
| Spindle static state pulse | ≤3 µm |
| Spindle vibration | ≤0.8 mm/s |
| Motor windings Pressure test | 1000V/1 minute withstanding Voltage test |
| Inverter Specifications | 2.2KW (220V) |
Dimensional Drawings

Figure: Spindle Side View with Dimensions (Diameter: 80mm, Length: 367mm)

Figure: Spindle Top View Dimensional Drawing

Figure: Spindle Front View Dimensional Drawing with Port Layout
3. Safety and Attentions
This section outlines critical safety precautions. Failure to follow these instructions may result in serious injury, death, or equipment damage.
General Safety Warnings:
- DANGER: Operations beyond requirements may lead to serious injury or death.
- ATTENTION: Operations beyond requirements may lead to moderate or minor injuries, as well as equipment damage.
Before Installation:
- DANGER: Do not use damaged or short-part drives. Risk of injury.
During Installation:
- DANGER: Install on metal or other flame-retardant objects to prevent fire.
- ATTENTION: Ensure proper heat dissipation if multiple AC drives are in the same cabinet. Prevent wires or bolts from falling into the AC drive.
Wiring:
- DANGER: Wiring must be performed by professional electrical engineering personnel. Ensure power is off before wiring. Make proper ground connections.
- ATTENTION: The input power line must NOT be connected to the output (U, V, W) terminals. Confirm wire specifications meet EMC and safety standards. Brake resistors must NOT be connected directly to DC bus (+) and (-) terminals.
Before Power On:
- ATTENTION: Confirm supply voltage matches AC drive nominal voltage. Verify correct input/output connections and check for short circuits. Power on only when the AC drive is covered.
After Power On:
- DANGER: Do not open the cover plate, touch AC drive or peripheral circuits with wet hands, or touch AC drive terminals after power on.
Additional Attentions:
- Motor Insulation: For new motors or those reused after long periods, inspect insulation. Separate motor wires from AC drive. Measured insulation resistance should be ≥5MΩ (using 500V megger).
- Motor Thermal Protection: Adjust parameters if the motor's rated capacity mismatches the AC drive.
- Power Frequency Operation: This AC drive supports 0-600Hz output frequency. Consider mechanical device tolerance for operations above 50Hz.
- Motor Heating and Noise: Expect some temperature rise, noise, and vibration compared to power frequency operation due to PWM output.
- Capacitive Conditions: Do not install capacitors or piezoresistors at the outlet side for thunder prevention or power factor improvement, as this can cause overcurrent and damage.
- Contactors/Switching Elements: If contactors are used between power supply and AC drive input, ensure intervals are sufficient (not less than one hour) to prevent shortening capacitor service life. If used between output and motor, ensure make-break operations occur only when AC drive has no output.
- Voltage Values: Do not apply the AC drive beyond allowable operating voltage ranges.
- Single-Phase Input: For types without specific single-phase input marks, do not use single-phase input, as it can cause damage.
- Lightning Protection: The AC drive has built-in lightning impulse protection. For areas with frequent thunder, install additional protection devices at the front end.
4. Installation
Installation Environment:
- Temperature: Operating environment temperature should be -10°C to +40°C.
- Mounting: Install vertically on flame-retardant surfaces, ensuring sufficient space for heat dissipation. Avoid vibration (e.g., from punching machines).
- Location: Avoid direct sunlight, moisture, corrosive gas, flammable/explosive gas, oil contamination, dirt, and metal dust.
Spindle Connection Ports:

Figure: Spindle Rear View with Labeled Connection Ports
| No. | Function | Definition |
|---|---|---|
| 1 | Gas sealing (Protection of impurities into the spindle) | Φ6 (0.2-0.25MPa) |
| 2 | Dust removal (Removing the shank and taper control impurity) | Φ6 (0.3-0.4MPa) |
| 3 | Enter water (Spindle cooling) | Φ8 |
| 4 | Return air (piston reset) | Φ6 (0.35-0.45MPa) |
| 5 | Power supply (Spindle power lines with thermistor) | U/V/W/ Ground wire |
| 6 | Intake air (Spindle loose knife) | Φ6 (0.5-0.6MPa) |
| 7 | Sensor (spindle tool change signals 24V) | Broach / loose knife |
| 8 | Water out (spindle cooling) | Φ8 |
Circulating Cooling System:
- Ensure cooling water temperature is between 24-28°C.
- Set a flow switch in the return pipe to monitor cooling water supply.
- Recommended coolant: Distilled water with Feinuokesi (Fenix) protective agent F1 (1:200 ratio).
- Inlet/outlet pipe temperature difference should not exceed 5°C.
Air Sealing Control:
- To prevent water or impurities from entering the spindle, a gas sealing device is required.
- The gas seal machine must start simultaneously with the spindle.
- Ensure multi-stage filtration for compressed air.
Compressed Gas Quality Requirements:
- Oil content: <0.01mg/m³
- Solid particle: <5µm
- Pressure dew point: <7.5°C (0.7MPa)
Peripheral Device Wiring Diagram (Example for AC Drive):

Figure: Peripheral Device Wiring Diagram for AC Drive
Note: This diagram illustrates general connections for an AC drive. Specific wiring for your setup may vary. Always consult the full manual for detailed wiring instructions and safety guidelines.
5. Operation and Display
Keypad Description:

Figure: FULING VFD Controller Keypad
- LED Display Area: Shows parameter settings and run status.
- Digital Display Area: Displays numerical values.
- PRGM/ESC Key: Enters the first-level menu or exits a parameter group.
- FUNC/DATA Key: In normal operation, displays status and information (frequency command, output frequency, current). In program mode, displays parameters and writes modified data.
- FWD/REV Key: Changes motor direction, slows down to 0Hz, and accelerates in the negative direction.
- JOG/> Key: Executes jog frequency command. In parameter operation, acts as the left shift key.
- RUN Key: Starts AC drive operation (no effect if set to terminal run).
- STOP/RST Key: Stops AC drive operation. Resets the drive if a fault occurs.
- UP/DOWN Keys: Selects parameter items and modifies parameters.
Function Code Examining and Modifying:
The BD600 series AC drives use a three-level menu structure for parameter setting:
- First-level menu: Functional parameter group (e.g., F00).
- Second-level menu: Function code (e.g., F00.10).
- Third-level menu: Function code setting value (e.g., 050.00).
To save settings, press the DATA key. To exit without saving, press the PRGM/ESC key.
Running-in Program Instructions:
Before initial use or after long periods of inactivity, the spindle must undergo a running-in process:
- Ensure all monitoring systems indicate no failures and all safety devices are installed and working correctly.
- Start the spindle at 25% of its maximum speed for 30 minutes.
- Increase to 50% of its maximum speed and run for 15 minutes.
- Finally, increase to maximum speed.
During this process, continuously monitor the spindle temperature. The spindle may become warm but should not be excessively hot to the touch. If it overheats, stop operation immediately and contact customer service.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your RATTMMOTOR spindle.
General Maintenance Guidelines:
- DANGER: Always power off and ensure the AC drive charge light is out before performing any repair or maintenance. Only qualified professionals should perform maintenance to avoid electric shock or injury.
- Routine Checks: Regularly inspect motor insulation and cable integrity.
- Cleaning: Keep the spindle and VFD free from dust and debris. Ensure cooling fins are clear for optimal heat dissipation.
- Cooling System: Periodically check the coolant level and quality. Replace coolant as recommended to prevent corrosion and maintain optimal temperature.
- Air System: Verify the air sealing system for proper pressure and filtration to prevent contaminants from entering the spindle.
Troubleshooting EMC Problems:
Electromagnetic compatibility (EMC) issues can affect AC drive performance. Common handling methods include:
- Grounding: Ensure the AC drive and all other electrical products are properly grounded, with ground resistance not exceeding 4Ω.
- Wiring Layout: Avoid placing power lines parallel to control lines. If necessary, arrange power lines vertically.
- Shielding: Use shielded cables for control signals and power lines between the AC drive and motor, especially in high-interference environments. Ensure reliable ground connection for shielding.
- Filters: Install surge suppressors, filters at signal input terminals, and linear/radio noise filters between the AC drive and power supply if interference persists.
7. Troubleshooting
The BD600 series AC drive provides various fault codes to help diagnose issues. If a fault occurs, the AC drive will display a code on the operation panel. Below are common faults and their solutions. For a comprehensive list, refer to the full manual.
Common Faults and Solutions:
| Display Code | Fault Name | Possible Causes | Solutions |
|---|---|---|---|
| E001 | Bus Under-voltage | Instantaneous power failure, input voltage too low, bus voltage abnormal, rectifier bridge/buffer resistance abnormal, drive/control board abnormal. | Fault reset, adjust input voltage, seek technical support. |
| E002 | Over-voltage during Acceleration | Input voltage too high, external force on motor, acceleration time too short, no brake unit/resistance. | Adjust voltage, remove external force, increase acceleration time, install brake unit/resistance. |
| E004 | Over-current during Acceleration | Output circuit short, incorrect motor parameters, acceleration time too short, unsuitable V/F curve, voltage too low, starting rotating motor, additional load, AC drive too small. | Eliminate external faults, self-learn motor parameters, increase acceleration time, adjust V/F curve, adjust voltage, use speed tracking, remove additional load, select higher power AC drive. |
| E007 | Motor Overload | Incorrect protection parameter (F09.10), load too heavy, motor lock-rotor, AC drive too small. | Correct parameter, reduce load, check motor/mechanical condition, select higher power AC drive. |
| E00E | Module Overheat | Ambient temperature too high, air filter blocked, fan damaged, thermally sensitive resistor damaged, inverter module damaged. | Lower ambient temperature, clean air filter, replace fan/resistor/module. |
| E015 | Current Detection Fault | HALL device faulty, drive board faulty. | Replace HALL device, replace drive board. |
| E026 | Encoder Fault | Incorrect encoder type, incorrect cable connection, damaged encoder, faulty PG card. | Set correct encoder type, eliminate external faults, replace encoder/PG card. |
| E034 | Too Large Speed Deviation | Incorrect encoder parameters, motor self-learning not performed, F09.17/F09.60 set incorrectly. | Set encoder parameters correctly, perform motor self-learning, set F09.17/F09.60 correctly. |
8. User Tips
- Initial Setup: Always perform the motor self-learning function (F02.37) for optimal vector control performance. This ensures the AC drive accurately matches the motor's parameters.
- Coolant Monitoring: Regularly check your cooling system. Maintaining the coolant temperature between 24-28°C is crucial for spindle longevity. Consider an alarm for out-of-range temperatures.
- Air Purity: Ensure your compressed air for sealing and dust removal meets the specified quality requirements (low oil, solid particle, and pressure dew point) to prevent contamination and damage to the spindle.
- Vibration Control: If you experience excessive vibration, check the spindle mounting, tool balance, and ensure the AC drive is isolated from external vibrations. Adjusting the speed loop output filter (F03.07) might help.
- Parameter Backup: After configuring all necessary parameters, it is advisable to record them or save them if your VFD supports parameter backup to prevent loss during power outages or resets.
9. Warranty and Support
RATTMMOTOR products are covered by a warranty to ensure customer satisfaction.
Warranty Terms:
- Warranty Period: 24 months from the date of purchase (refer to the barcode on the equipment). Free maintenance is provided for failures or damages under normal use and adherence to instructions.
- Charged Maintenance: Maintenance will be charged for damages resulting from:
- Improper use, repair, or modification without prior permission.
- Fire, flood, abnormal voltage, other disasters, or secondary disasters.
- Hardware damage due to dropping or transportation after procurement.
- Improper operation.
- Trouble originating from external equipment.
- Warranty Card: Please fill out the Warranty Card in detail for any product failure or damage. The Warranty Card is not re-issued; keep it safe and present it for maintenance.
Technical Support:
For any problems during service, please contact your RATTMMOTOR agent or Folinn directly for technical assistance.