1. Introduction
The Voktta DC720 Universal Coulometer is a versatile digital power energy meter designed for batteries. It provides comprehensive monitoring capabilities, including real-time measurement of voltage, current, power, battery capacity, battery energy, temperature, time, and percentage power. It supports bidirectional metering, indicating both charging and discharging status. This manual provides detailed instructions for the setup, operation, and maintenance of your DC720 meter.
2. Product Overview
2.1 Main Features
- High-definition IPS LCD color screen for clear display and accurate measurement.
- Supports zeroing of accumulated data and no-load zeroing.
- Voltage and current display fine-tuning.
- Percentage power display based on user-set capacity.
- Simultaneous measurement of 9 parameters: voltage, current, power, real-time battery capacity, battery energy, temperature, time, percentage power, and charge/discharge status.
2.2 Display Interface Introduction
The DC720 features a clear IPS LCD screen that displays various parameters. Refer to the diagram below for an explanation of each display element.

Figure 1: DC720 Display Interface
- Temperature: Current ambient or sensor temperature.
- Real-time voltage: Instantaneous voltage reading.
- Real-time current: Instantaneous current reading.
- Real-time power: Instantaneous power (Watts) reading.
- Battery energy: Accumulated energy (Wh).
- Real-time battery capacity: Accumulated capacity (Ah).
- Power display: Percentage of battery capacity remaining, based on total preset battery capacity and actual capacity.
- Accumulated running time: Total operational time in hhh:mmss (hours:minutes:seconds).
- Status indication: 'DSG' for discharging, 'CHG' for charging.
2.3 Product Dimensions
The main meter unit and shunt adapter plates have specific dimensions for installation.

Figure 2: DC720 20A Meter Dimensions (Approx. 4.76cm L x 2.86cm W x 2.60cm H)

Figure 3: DC720 Shunt Adapter Plate Dimensions (Approx. 9.66cm L x 4.96cm W x 1.73cm H)
3. Setup and Installation
3.1 Mounting
The meter mounting aperture required is 45mm x 26mm.
3.2 Wiring Instructions
Correct wiring is crucial for accurate measurements and safe operation. Please follow the diagrams carefully based on your chosen current range.
3.2.1 20A Range Wiring (Direct Measurement)
For the 20A range, the meter connects directly to the circuit without an external shunt. Use the provided 2P terminal block.

Figure 4: 20A Range Wiring Diagram (DC7-200V Battery)
3.2.2 100A/200A/300A/400A/500A Range Wiring (with Shunt Adapter Plate)
For current ranges above 20A, a shunt adapter plate is required. The meter connects to the shunt via the XH2.54 Reverse 6P 300mm connection cable. There are two main wiring methods for the power supply to the meter:
Direct Power Wiring
In this configuration, the meter draws its operating power directly from the battery being measured. Be careful to distinguish the shunt marking (Battery- and Load/Charger-).

Figure 5: Direct Power Wiring Diagram (DC0-200V Battery, DC7-30V Meter Power)
Individual Power Supply Wiring
If you prefer to power the meter independently or if the main battery voltage is outside the meter's operating voltage range (DC7-200V), you can use a separate power source for the meter. Be careful to distinguish the shunt marking.

Figure 6: Individual Power Supply Wiring Diagram (DC0-200V Battery, DC7-30V Meter Power)
Note: The package includes a meter, XH2.54 Reverse 6P 300mm connection cable, XH2.54 2P red and black wire, shunt adapter plate (with splitter), M8x25mm bolts (x2), and wiring copper rings (x2).
4. Operating Instructions
4.1 Menu Navigation
The DC720 meter features a menu system for configuration and data management. Use the buttons on the front panel to navigate and select options.

Figure 7: DC720 Menu Options
- DATA CELEAR: Clears all accumulated data to zero.
- FORCED TO ZERO: Performs a no-load forced zeroing.
- RANGE: Sets the current measurement range (Note: 20A range does not have this menu option as it's fixed).
- V-ADJ: (000.00V): Allows fine-tuning of the displayed voltage (does not affect the actual voltage).
- A-ADJ: (00.00A): Allows fine-tuning of the displayed current (does not affect the actual current).
- FULL-CAP: (050.0AH): Sets the full capacity of the battery in Ampere-hours (Ah). This is used for percentage display calculation.
- REM-CAP: (000.0AH): Displays the actual remaining charging capacity of the battery.
- RESET: Resets the device to factory default settings.
- EXIT: Exits the menu and returns to the main display.
4.2 Data Zeroing and Fine-tuning
- Data Zeroing: Supported via the 'DATA CELEAR' menu option.
- No-load Zeroing: Supported via the 'FORCED TO ZERO' menu option.
- Voltage Display Fine-tuning: Supported via the 'V-ADJ' menu option.
- Current Display Fine-tuning: Supported via the 'A-ADJ' menu option.
4.3 Percentage Power Display
To ensure accurate percentage power display, you must manually set the 'FULL-CAP' (full battery capacity) in the menu to match your battery's specifications.
5. Maintenance
The DC720 meter is designed for durability and requires minimal maintenance. Keep the device clean and dry. Avoid exposure to extreme temperatures, humidity, or corrosive environments. Do not attempt to open the casing or modify the internal components, as this will void any potential warranty.
6. Troubleshooting
If you encounter issues with your DC720 meter, consider the following:
- No Display: Check the power supply connections to ensure the meter is receiving power within its operating voltage range (DC7-200V).
- Incorrect Readings: Verify all wiring connections are secure and correct according to the diagrams. Ensure the correct current range is selected in the menu (if applicable) and that the shunt is properly installed for higher current measurements. If readings are slightly off, use the 'V-ADJ' and 'A-ADJ' functions for fine-tuning.
- Percentage Display Inaccurate: Ensure the 'FULL-CAP' setting in the menu accurately reflects your battery's total capacity.
- No Current Reading (for shunt models): Check the connection cable between the meter and the shunt adapter plate. Ensure the shunt itself is correctly installed in the main circuit.
7. Specifications
| Parameter | Value |
|---|---|
| Brand | Voktta |
| Model Number | DC720 |
| Instrument Operating Voltage | DC7~200V |
| Voltage Measurement Range | DC7~200V |
| Current Measurement Range | 20.00A (direct), 100.0A, 200.0A, 300.0A, 400.0A, 500.0A (with shunt) |
| Power Measurement Range | 00.00W~1.000KW~999.9KW |
| Capacity Measurement Range | 0~999.999Ah |
| Energy Measurement Range | 0~99999.9Wh |
| Temperature Measurement Range | 0~99℃ |
| Time Measurement Range | 0~999:59:59 (hours:minutes:seconds) |
| Display Type | Digital Only (IPS LCD Color Screen) |
| Power Supply / Source | DC |
| DIY Supplies | Electrical |
| Certification | CE |
| Product Size | 47.59mm × 28.67mm × 25.33mm |
| Meter Mounting Aperture | 45mm × 26mm |
8. User Tips
- Always ensure power is disconnected before making or changing any wiring connections to prevent damage to the device or personal injury.
- For critical applications, verify readings with a calibrated multimeter if possible.
- Regularly check the 'FULL-CAP' setting if your battery capacity changes or degrades over time to maintain accurate percentage displays.
- Keep the display clean for optimal readability.
9. Warranty and Support
For any technical support or warranty inquiries, please refer to your purchase documentation or contact the seller directly. A user manual in PDF format may also be available for download from the seller's product page or via the following link: DC720 User Manual (PDF).