1. Introduction
1.1 About This Manual
This manual describes the assembly, installation, operation, and troubleshooting of the SUMRY Hybrid Solar Inverter. Please read this manual carefully before installations and operations. Keep this manual for future reference.
This manual provides safety and installation guidelines as well as information on tools and wiring.
1.2 Features
- Pure sine wave inverter
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible with mains voltage or generator power
- Auto restart while AC is recovering
- Overload, over temperature, and short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
- Built-in 120A MPPT Solar charge (max 4200W for 3.6KW, max 6000W for 6.2KW)
- High PV input voltage range (60-500VDC)
- AC output Voltage 120VC (for some models)
- WIFI & GPRS available for iOS and Android (optional)
- Dual output
1.3 Basic System Architecture
The following illustration shows the basic application for this inverter/charger. It includes connections for solar panels, utility grid, generator, lithium battery, and home appliances. The inverter can power various appliances in home or office environments, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners.


2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION – Only qualified personnel can install this device with battery. NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Product Overview
The inverter features a clear LCD display and various ports for connectivity and power management.


3.1 Components and Indicators
| No. | Component/Indicator |
|---|---|
| 1 | LCD display |
| 2 | Status indicator |
| 3 | Charging indicator |
| 4 | Fault indicator |
| 5 | Function buttons |
| 6 | Power on/off switch |
| 7 | AC input |
| 8 | Main output |
| 9 | Second output |
| 10 | Battery input |
| 11 | PV input |
| 12 | Anti dust kit |
| 13 | WIFI communication/RS-232 port |
| 14 | Battery communication/RS-485 port |
3.2 Product Demonstration
Video demonstrating the physical overview and basic wiring connections of the SUMRY Hybrid Solar Inverter.
4. Installation
4.1 Unpacking and Inspection
Before installation, inspect the unit. Be sure that nothing inside the package is damaged. You should have received the unit and a user manual.
4.2 Preparation
Before connecting any lines, remove the screws under the machine and remove the bottom cover plate.
4.3 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Make sure that other objects and surfaces are left with enough space from the machine to ensure adequate heat dissipation and that there is enough room to remove the wires.
WARNING: SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two M6 screws.
4.4 Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in below table as required fuse or breaker size.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable as below.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 2AWG | 25 | 2 Nm |
Please follow below steps to implement battery connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the chart below.

- Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with torque of 2 Nm in clockwise direction. Make sure polarity at both the battery and the inverter/charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
4.4.1 Lithium Battery Communication and Setting
The communication between the battery and the inverter can be realized through the battery communication interface, so that the inverter and the lithium battery can exchange information (Baud rate: 9600).
If choosing a lithium battery for the inverter, only lithium batteries that have been matched with BMS communication protocol are allowed.
- Connect the battery according to the recommended battery cable specifications.
- Insert the ring terminal of the battery cable into the battery connector of the inverter flatly, and ensure that the bolts are tightened with a torque of 2-3 Nm. Make sure that the polarities of the battery and inverter are connected correctly, and that the ring terminal is tightened with the battery terminal.
- Connect one side of RJ45 cable to the BMS communication port of inverter.
- Insert the other side of RJ45 cable into RS485 communication port on lithium battery.
NOTE: If you choose a lithium battery, please make sure to connect the battery and inverter with BMS communication cable, and select the battery type as "LIB-485" mode.
RJ45 Pin Definition
| Pin number | Port definitions |
|---|---|
| 1 | RS485B |
| 2 | RS485A |
| 3 | NG |
| 4 | NG |
| 5 | NG |
| 6 | NG |
| 7 | RS485A |
| 8 | RS485B |
LCD Settings for Lithium Battery
In order to communicate with the lithium battery BMS, you should press the "ENTER" button for a long time, and set the battery type as "LIB-485" in program 05. Then select the matching battery protocol in Program 43.
CAUTION: When the battery type is set to "LIB-485", the setting items 12, 13 and 29 are displayed in percentage. When the battery type is set to "LIB-485", the user cannot modify the maximum charging current. When communication fails, the inverter will cut off the output.
4.5 AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 32A for 3.6KW/4.2KW and 50A for 6.2KW.
CAUTION!! There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested cable requirement for AC wires
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 3.6KW/4.2KW | 12 AWG | 4 | 1.2 Nm |
| 6.2KW | 10 AWG | 6 | 1.2 Nm |
Please follow below steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. L→LINE (brown or black), N→Neutral (blue).
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
- Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws. L→LINE (brown or black), N→Neutral (blue).
- Make sure the wires are securely connected.
CAUTION: Appliances such as air conditioner are required at least 2~3 minutes to restart because it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer of air conditioner if it's equipped with time-delay function before installation. Otherwise, this inverter/charger will trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner.
4.6 PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested cable requirement for PV wires
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
| INVERTER MODEL | 3.6KW/4.2KW | 6.2KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc | |
Recommended PV Module Configurations (Example: 250Wp PV module)
| Solar Panel Spec. (reference) | SOLAR INPUT (Min in serial: 6 pcs, max. in serial: 13 pcs) | Q'ty of panels | Total input power |
|---|---|---|---|
| 250Wp Vmp: 30.1Vdc Imp: 8.3A Voc: 37.7Vdc Isc: 8.4A Cells: 60 | 6 pcs in serial | 6 pcs | 1500W |
| 8 pcs in serial | 8 pcs | 2000W | |
| 12 pcs in serial | 12 pcs | 3000W | |
| 13 pcs in serial | 13 pcs | 3250W | |
| 8 pieces in serial and 2 sets in parallel | 16 pcs | 4000W | |
| 10 pieces in serial and 2 sets in parallel | 20 pcs | 5000W | |
| 12 pieces in serial and 2 sets in parallel | 24 pcs | 6500W | |
| 10 pieces in serial and 3 sets in parallel | 30 pcs | 7500W |
PV Module Wire Connection
Please follow below steps to implement PV module connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.
4.7 Final Assembly
After connecting all wirings, please put the bottom cover back by screwing two screws.
4.8 Communication Connection
4.8.1 Wi-Fi Cloud Communication (option)
Please use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP and install it from the APP store, and refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be shown by mobile phone APP or webpage of a computer.
4.8.2 GPRS Cloud Communication (option)
Please use the supplied communication cable to connect to the inverter and GPRS module, and then apply external power to the GPRS module. Download the APP and install it from the APP store, and refer to the "GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status will be shown by mobile phone APP or webpage of a computer.

5. Operation
5.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
5.2 Operation and Display Panel
The operation and display panel is on the front panel of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.
LED Indicator
| LED Indicator | Color | Status | Messages |
|---|---|---|---|
| INV/AC | Green | Solid On | Output is powered by utility in Line mode. |
| Flashing | Output is powered by battery or PV in battery mode. | ||
| CHG | Green | Solid On | Battery is fully charged. |
| Flashing | Battery is charging. | ||
| FAULT | Red | Solid On | Fault occurs in the inverter. |
| Flashing | Warning condition occurs in the inverter. |
Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
5.3 LCD Display Icons
The LCD display provides various information about the inverter's status and operation.
Input Source Information
- Indicates the AC input.
- Indicates the PV input.
- Indicates input voltage, input frequency, PV voltage, charger current (if PV in charging for 3.6KW models), charger power, battery voltage.
Configuration Program and Fault Information
- Indicates the setting programs.
- Indicates the warning and fault codes.
- Warning: Flashing with warning code.
- Fault: Lighting with fault code.
Output Information
- Indicates output voltage, output frequency, load percent, load in VA, load in Watt, and discharging current.
Battery Information
- Battery icon with charge level.
Load Information
- Indicates overload.
Mode Operation Information
- Indicates unit connects to the mains.
- Indicates unit connects to the PV panel.
- Indicates load is supplied by utility power.
- Indicates the utility charger circuit is working.
- Indicates the DC/AC inverter circuit is working.
Mute Operation
- Indicates unit alarm is disabled.
5.4 LCD Setting
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Press “UP” or “DOWN" button to select setting programs. And then, press "ENTER" button to confirm the selection or ESC button to exit.
The manual provides detailed tables for various LCD settings, including output source priority, maximum charging current, AC input voltage range, battery type, auto restart settings, output frequency, output voltage, maximum utility charging current, setting voltage point back to utility source, power point of dual output function, bulk charging voltage, floating charging voltage, low DC cut-off voltage, battery equalization, equalization interval, equalization activated immediately, GRID-tie operation, GRID-tie current, LED pattern light, dual output, dual output functional voltage point, lithium battery protocol, and delayed grid access.
5.5 Operating Mode Description
The inverter supports various operating modes:
- Standby Mode: The inverter is not turned on yet, but it can charge batteries without AC output.
- Line Mode: The unit will provide output power from the mains and will also charge the battery.
- Grid-Tie Operation: When working in Grid-Tie mode, the unit will flash.
- Battery Mode: The unit will provide output power from the battery and PV.
5.6 RGB Light (option)
- Battery Mode: Red Light
- Utility Mode: Blue Light
- PV Mode: Purple Light
5.7 Battery Equalization
Battery equalization reverses the buildup of negative chemical effects like stratification and removes sulfate crystals, which can reduce battery capacity. It is recommended to equalize the battery periodically.
How to Apply Equalization Function
You must enable the battery equalization function in monitoring LCD setting program 30 first. Then, you may apply this function in the device by either one of the following methods:
- Setting equalization interval in program 35.
- Active equalization immediately in program 36.
When to Equalize
In the float stage, when the setting equalization interval (battery equalization cycle) is arrived, or equalization is active immediately, the controller will start to enter the Equalize stage.
Equalize Charging Time and Timeout
In the Equalize stage, the controller supplies power to charge the battery until the battery voltage reaches the equalization voltage. Constant-voltage regulation is applied to maintain the battery voltage at the equalization voltage. The battery remains in the Equalize stage until the set battery equalized time is reached.
If the battery equalized time expires and the battery voltage does not reach the equalization voltage point, the charge controller will extend the battery equalized time until the battery voltage achieves the equalization voltage. If the battery voltage is still lower than the battery equalization voltage when the battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.
5.8 Mains and Lithium Battery Activation Function
- After 90s of mains power connection to the inverter, the machine is connected to the mains and starts to work.
- If the inverter is in lithium battery mode (item 05 is Llb or Llb-485), and the mains is connected but the battery is not connected, the mains activation function is automatically enabled.
6. Maintenance
6.1 Clearance and Maintenance for Anti-Dust Kit
6.1.1 Overview
Every inverter is already installed with an anti-dust kit from the factory. The inverter will automatically detect this kit and activate an internal thermal sensor to adjust the internal temperature. This kit also keeps dust out of your inverter and increases product reliability in harsh environments.
6.1.2 Clearance and Maintenance Steps
- Loosen the screw in a counterclockwise direction on the top of the inverter.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
7. Troubleshooting
7.1 Fault Reference Code
The following table lists common fault codes, their explanations, and recommended actions.
| Fault Code | Fault Event | Explanation / Possible cause | What to do |
|---|---|---|---|
| 01 | Fan is locked when inverter is off. | Replace the fan. | |
| 02 | Over temperature | Temperature of internal converter component is over 120°C. Internal temperature of inverter component is over 100°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. |
| 03 | Battery voltage is too high | Battery is over-charged. | Return to repair center. Check if spec and quantity of batteries are meet requirements. |
| 04 | Battery voltage is too low | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| 05 | Output short circuited or over temperature is detected by internal converter components. | Output short circuited. | Check if wiring is connected well and remove abnormal load. |
| 06/58 | Output voltage is too high / Output voltage is too low | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center. |
| 07 | Overload time out | Overload error. The inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. |
| 08/09/53/57 | Bus voltage is too high / Bus soft start failed / Inverter soft start failed / Current sensor failed | Internal components failed. | Return to repair center. |
| 51 | Over current or surge. | Over current or surge. | Restart the unit, if the error happens again, please return to repair center. |
| 52 | Bus voltage is too low. | Bus voltage is too low. | Restart the unit, if the error happens again, please return to repair center. |
| 55 | Over DC voltage in AC output | Output voltage is unbalanced. | Restart the unit, if the error happens again, please return to repair center. |
| 59 | PV voltage is over limitation |
7.2 Warning Indicator
The following table lists warning events, their audible alarms, and corresponding icon flashing.
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second | 01 |
| 03 | Battery is over-charged | Beep once every second | 03 |
| 04 | Low battery | Beep once every second | 04 |
| 07 | Overload | Beep once every 0.5 second | 07 |
| 10 | Output power derating | Beep twice every 3 seconds | 10 |
| 15 | PV energy is low. | Beep twice every 3 seconds | 15 |
| E9 | Battery equalization | None | E9 |
| 6P | Battery is not connected | None | 6P |
8. Specifications
8.1 Line Mode Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | ||
| Nominal Input Voltage | 230Vac | ||
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | ||
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | ||
| High Loss Voltage | 280Vac±7V | ||
| High Loss Return Voltage | 270Vac±7V | ||
| Max AC Input Voltage | 300Vac | ||
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | ||
| Low Loss Frequency | 40±1Hz | ||
| Low Loss Return Frequency | 42±1Hz | ||
| High Loss Frequency | 65±1Hz | ||
| High Loss Return Frequency | 63±1Hz | ||
| Output Short Circuit Protection | Circuit Breaker | ||
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | ||
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | ||
8.2 Inverter Mode Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Rated Output Power | 3.6KW | 4.2KW | 6.2KW |
| Output Voltage Waveform | Pure Sine Wave | ||
| Output Voltage Regulation | 230Vac±5% | ||
| Output Frequency | 50Hz | ||
| Peak Efficiency | 93% | ||
| Overload Protection | 3s@≥150% load; 5s@101%~150% load | ||
| Surge Capacity | 2* rated power for 5 seconds | ||
| Nominal DC Input Voltage | 24Vdc | 48Vdc | |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc | |
| Low DC Warning Voltage @load < 50% | 22.0Vdc | 44.0Vdc | |
| Low DC Warning Voltage @load ≥ 50% | 21.0Vdc | 42.0Vdc | |
| Low DC Warning Return Voltage @load < 50% | 22.5Vdc | 45.0Vdc | |
| Low DC Warning Return Voltage @load ≥ 50% | 22.0Vdc | 44.0Vdc | |
| Low DC Cut-off Voltage @load < 50% | 20.5Vdc | 41.0Vdc | |
| Low DC Cut-off Voltage @load ≥ 50% | 20.0Vdc | 40.0Vdc | |
| High DC Recovery Voltage | 32Vdc | 62Vdc | |
| High DC Cut-off Voltage | 33Vdc | 63Vdc | |
| No Load Power Consumption | 30W | 35W | 50W |
8.3 Two Load Output Power
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Full Load | 3600W | 4200W | 6200W |
| Maximum Main Load | 3600W | 4200W | 6200W |
| Second Load Range | 720W~2520W | 840W~2940W | 1240W~4340W |
| Main Load Cut Off Voltage | 22VDC | 44VDC | |
| Main Load Return Voltage | 26VDC | 52VDC | |
8.4 Charge Mode Specifications
Utility Charging Mode
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Charging Algorithm | 3-Step | ||
| AC Charging Current (Max) | 100Amp (@VI/P=230Vac) | ||
| Bulk Charging Voltage (Flooded Battery) | 29.2 | 58.4 | |
| Bulk Charging Voltage (AGM / Gel Battery) | 28.2 | 56.4 | |
| Floating Charging Voltage | 27Vdc | 54Vdc | |
MPPT Solar Charging Mode
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Max. PV Array Power | 6200W | 6500W | |
| Nominal PV Voltage | 240Vdc | 360Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~500Vdc | ||
| Max. PV Array Open Circuit Voltage | 500Vdc | ||
| Max Charging Current (AC charger plus solar charger) | 120Amp | 120Amp | 120Amp |
8.5 Grid-Tie Operation
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Nominal Output Voltage | 220/230/240 VAC | ||
| Feed-in Grid Voltage Range | 195~253VAC | ||
| Feed-in Grid Frequency Range | 50±1Hz/60±1Hz | ||
| Nominal Output Current | 15.7A | 18.2A | 26.9A |
| Power Factor Range | >0.99 | ||
| Maximum Conversion Efficiency (DC/AC) | 97% | ||
8.6 General Specifications
| INVERTER MODEL | 3.6KW | 4.2KW | 6.2KW |
|---|---|---|---|
| Safety Certification | CE | ||
| Operating Temperature Range | -10°C to 50°C | ||
| Storage temperature | -15°C~60°C | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||
| Dimension (D*W*H), mm | 358×442×116 | ||
| Net Weight, kg | 8.0 | 8.0 | 8.9 |
9. User Tips
- Battery-Free Operation: This inverter can operate without batteries, utilizing solar and/or utility power directly.
- Utility Grid Connection: The inverter is designed to connect to the electric utility grid, allowing for flexible power management.
- Battery Compatibility: The inverter is compatible with various battery types, including Flooded, Gel, Lithium-iron phosphate, Lithium-ion, AGM/Sealed, and user-customized batteries. Ensure the correct battery type is selected in the LCD settings (Program 05) for optimal performance, especially for lithium batteries (LIB-485 mode).
- AC Output Voltage: The AC output voltage is configurable, with options for 110V and 120V, depending on the model and settings.
- Appliance Compatibility: This inverter is capable of powering a wide range of home and office appliances, including motor-type loads such as air conditioners, refrigerators, fans, and tube lights.
- Air Conditioner Restart Delay: For appliances like air conditioners, a 2-3 minute restart delay is often required to balance refrigerant gas. If your air conditioner does not have a built-in time-delay function, a power shortage and quick recovery could cause damage. The inverter may trigger an overload fault to protect the appliance, but internal damage can still occur.
10. Warranty & Support
All SUMRY products come with a 1-year warranty from the store. For technical support or service, please contact your local dealer or service center.
For additional item guides and documents, you may refer to the official user manual PDF: User manual (PDF).
11. Appendix
11.1 Approximate Back-up Time Table
| Model | Load (W) | Backup Time @ 24Vdc 100Ah (min) | Backup Time @ 24Vdc 200Ah (min) |
|---|---|---|---|
| 3.6KW/4.2KW | 300 | 449 | 1100 |
| 600 | 222 | 525 | |
| 900 | 124 | 303 | |
| 1200 | 95 | 227 | |
| 1500 | 68 | 164 | |
| 1800 | 56 | 126 | |
| 2100 | 48 | 108 | |
| 2400 | 35 | 94 | |
| 2700 | 31 | 74 | |
| 3200 | 28 | 67 | |
| 3600 | 25 | 60 | |
| 4200 | 22 | 53 | |
| 6.2KW | 500 | 613 | 1288 |
| 1000 | 268 | 613 | |
| 1500 | 158 | 402 | |
| 2000 | 111 | 271 | |
| 2500 | 90 | 215 | |
| 3200 | 76 | 182 | |
| 3500 | 65 | 141 | |
| 4000 | 50 | 112 | |
| 4500 | 44 | 100 | |
| 5000 | 40 | 90 | |
| 6200 | 36 | 80 |
Note:
- Backup time depends on the quality of the battery, age of battery, and type of battery. Specifications of batteries may vary depending on different manufacturers.
- The final interpretation right of this product belongs to the company.