JIKONG JK-PB2A16S20P

Contents

JIKONG Inverter BMS V19 User Manual

Model: JK-PB2A16S20P | Version: 19.0.1

Lithium Battery Active Balance Protection Board

1. Product Overview

The JIKONG Inverter BMS (Battery Management System) is a sophisticated management system designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge/over-discharge/overcurrent/over-temperature protection, coulomb metering, Bluetooth communication, and host computer monitoring capabilities. This BMS is suitable for LiFePo4, Li-Ion, and LTO battery types.

The protection board utilizes energy transfer active balancing technology to achieve a maximum continuous 1A/2A balance current, ensuring battery consistency, extending battery life, and delaying aging. It is compact, easy to operate, and fully functional, making it ideal for high-power energy storage, base station backup power supplies, and solar power station battery packs.

Key Features:

  • LED Bluetooth status indicator
  • APP Bluetooth remote operation (Android, iOS, HarmonyOS support)
  • Battery capacity calculation
  • Supports PC operations
  • High precision voltage acquisition (±3mV)
  • High precision current acquisition
  • Support information screen display
  • Accurate time logging
  • Support RS485 and CAN communication
  • Heating function for low-temperature environments
  • Alarm dry contact function
  • Comprehensive protection: Overcharge, Over-discharge, Overcurrent, Over-temperature, Low-temperature, Short Circuit
  • Emergency switch function
  • Intelligent sleep mode
  • Battery parallel current limiting function
JIKONG Home Energy Storage BMS components
Figure 1.1: JIKONG Home Energy Storage BMS with display, interface board, and main board (front and reverse views). App supports iOS, Android, and HarmonyOS.
JIKONG BMS applications in home energy storage and industrial settings
Figure 1.2: Tailor-made for home energy storage systems, also suitable for communication base stations, building energy storage, and industrial equipment backup power.

2. Product Components

Packing List:

The standard package includes the following items:

JIKONG BMS Packing List
Figure 2.1: Packing List. Items include BMS, interface board, various adapter cables, network cable, sampling lines, and switch.
  1. BMS x 1
  2. Interface board x 1
  3. Adapter cable B x 1 (long 30cm)
  4. Adapter cable A x 1 (long 30cm)
  5. RS45 Network cable x 1 (long 40cm)
  6. Cells total B+ Cable x 1 (long 50cm)
  7. Sampling line A x 2 (long 90cm)
  8. Sampling line B x 1 (long 90cm)
  9. Sampling line C x 1 (long 90cm)
  10. Switch x 1 (long 50cm)
  11. Adapter cable C x 1 (long 30cm)
  12. Heating Adapter cable x 1 (long 17cm)
  13. Adapter x 1

Product Unboxing Video:

Video 2.2: Unboxing and overview of the JIKONG Inverter BMS and its included accessories.

3. Specifications

The JIKONG Inverter BMS V19 is available in several configurations, primarily differing in continuous discharge current and balance current. Below are the general specifications for the series.

General Product Specifications:

Technical IndexJK-PB1A16S10PJK-PB1A16S15PJK-PB2A16S15PJK-PB2A16S20PJK-PB2A16S30P
Number of Battery Strings (Li-ion)7S-16S7S-16S7S-16S7S-16S7S-16S
Number of Battery Strings (LiFePo4)8S-16S8S-16S8S-16S8S-16S8S-16S
Number of Battery Strings (LTO)14S-16S14S-16S14S-16S14S-16S14S-16S
Balance MethodActive Balance (Full State On)
Balance Current1A1A2A2A2A
Conductive Resistance in Main Circuit1mΩ0.65mΩ0.65mΩ0.47mΩ0.25mΩ
Continuous Discharge Current100A150A150A200A300A
Maximum Discharge Current (MAX 2min)100A150A150A200A300A
Over Charge Protection Current (ADJ)200A300A300A350A600A
Other Interfaces (Default)RS485/232/CAN/UART
Supply Voltage20-70V
Wiring OutputCommon Port
Single Cell Voltage Range1-5V
Voltage Acquisition Accuracy±5mV
Over Charge Protection Voltage1.2-4.35V Adjustable
Over Charge Release Voltage1.2-4.35V Adjustable
Over Current Detect Delay2-120S Adjustable
Over Discharge Protection Voltage1.2-4.35V Adjustable
Over Discharge Release Voltage1.2-4.35V Adjustable
Quantity of Temperature Detection4
Temp ProtectionYes
Short Circuit ProtectionYes
Coulomb CounterYes
Bluetooth FunctionSupport for Android/iOS/Harmony
Parallel charging current limiting10A
Address dial switch4
DRY Contact2
JIKONG Product Specifications Table
Figure 3.1: Detailed product specifications for various JIKONG BMS models.

Physical Dimensions:

  • BMS Board: 300mm x 100mm x 24mm (Length x Width x Height)
  • Package Weight: Approximately 1.1 kg
JIKONG 4.3 inch Touch Screen Display dimensions
Figure 3.2: Dimensions of the 4.3-inch touch screen display (135.9mm x 88.5mm).
JIKONG 4.3 inch Touch Screen Display back view dimensions
Figure 3.3: Back view dimensions of the 4.3-inch touch screen display (129.4mm x 82mm) with TF Card Holder.
JIKONG Interface Board dimensions
Figure 3.4: Dimensions of the interface board (138mm x 96mm).

4. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your JIKONG Inverter BMS. Please follow these instructions carefully.

4.1. Pre-Installation Checks:

  • Ensure all balance cables are properly connected.
  • Verify that the P- and B- connections are correct.
  • Confirm the protection board is securely fixed to the battery pack.
  • Do not power on the BMS until all connections are verified as correct to prevent malfunction or damage.

4.2. Wiring Diagrams:

The JK-PB1/2A16S-10/15/20P series protection board is suitable for 7-16 series lithium battery packs. Wiring methods vary depending on the number of cells. Refer to the diagrams below for specific wiring instructions.

JIKONG BMS Wiring Diagram for 16-string and 8-string cells
Figure 4.1: Wiring method for 16-string cells (top) and 8-string cells (bottom). Connect all cables, insert into BMS, then connect B-line and P-line to the battery. Note: Only the first B8 cable needs to be connected; the second B8 cable is not required.

4.3. Interface Board Connections:

The interface board provides connections for LED indicators, reset switch, DIP switch, dry contacts, and communication functions.

JIKONG BMS Interface Board Diagram
Figure 4.2: Interface board diagram showing various ports and switches.

Key Interface Definitions:

  • P1 (2*10P Connector): Connects to the interface board.
  • P2 (XH-2.54-6P Connector): Connects to the interface board.
  • P3 (HY-2.0-10P Connector): Connects to the interface board.
  • P4 (A1254WF-6A URAT Display Interface): For display screen connection. Includes pins for activation signals (K-, K+), ground (GND), UART RX/TX (5V), and VCC for display power output.
  • P5 (A1254WF-6A Display Interface): For display screen connection. Includes pins for RS485-A/B, ground (GND), and activation signals (K+, K-).
  • P6 (HY2.0-7P Acquisition Interface): Connects to NTC1 temperature probe and battery cell positives (B0-B4 for cells 1-4).
  • P7 (HY2.0-6P Acquisition Interface): Connects to NTC2 temperature probe.
  • P8 (HY2.0-7P Acquisition Interface): Connects to NTC3 temperature probe and battery cell positives (B8-B12 for cells 5-8).
  • P9 (HY2.0-6P Acquisition Interface): Connects to NTC4 temperature probe and battery cell positives (B13-B16 for cells 9-12).
  • P10 (M3 Screw Heating Interface): Connects to heater element negative electrode (HT-).
  • P11 (M3 Screw Power Input): Connects to power input positive (B+).
  • D1 (Bluetooth Connection Indicator): Blinks when disconnected, steady on when connected.
  • P- (M6 Screw): Connects to external load or negative terminal of charger.
  • B- (M6 Screw): Connects to the negative battery terminal.

4.4. Device Activation:

The BMS is designed for charging activation. After battery assembly, connect a charger (voltage 2V higher than battery voltage) to activate the BMS. Alternatively, if a display screen and button are used, insert the cable into the display interface and press the button to activate.

4.5. Parallel Function Setup:

The parallel function allows simultaneous monitoring of multiple BMS units via an upper computer using the RS485 bus. This requires a USB to RS485 serial port cable and JIKONG upper computer software.

DIP Switch Settings for Addressing:

Each BMS in a parallel setup needs a unique address (0-15). BMS with address 0 acts as the host, and BMS with addresses 1-15 are slaves. The address is set using the DIP switches on the interface board.

AddressDIP Switch Position (1-4)
1234
0 (Host)OFFOFFOFFOFF
1 (Slave)ONOFFOFFOFF
2 (Slave)OFFONOFFOFF
...............
15 (Slave)ONONONON
JIKONG BMS App UART Protocol Setup
Figure 4.3: Mobile App interface for selecting UART protocol and basic settings.
JIKONG BMS PC Software Protocol Setup
Figure 4.4: PC software interface for setting inverter communication protocols (e.g., Deye, PylonTech, Growatt, Voltronic, China Tower, WOW).
JIKONG BMS Parallel Monitoring Diagram
Figure 4.5: Diagram illustrating parallel monitoring of multiple JIKONG BMS units via USB to RS485 connection to a host computer.

5. Operation

The JIKONG Inverter BMS offers various functions to manage and protect your battery system. These functions can be configured and monitored via the mobile APP or PC software.

5.1. Mobile APP and PC Software:

The BMS features multi-screen display and data connection, allowing you to monitor your battery system via a mobile APP, PC software, or a dedicated JIKONG home storage display.

JIKONG BMS Multi-screen display options
Figure 5.1: Multi-screen display options for JIKONG BMS, including mobile APP, PC software, and dedicated home storage display.

APP Installation:

Download the mobile APP by scanning the QR code below. Android Version 7 or higher is required.

JIKONG BMS App QR Code
Figure 5.2: QR code for JIKONG Mobile APP download.

5.2. Parameter Settings:

You can freely adjust multiple protection values such as overcharge, over-discharge, overcurrent, temperature, and balance via the APP or PC software. Always read the internal parameters of the protection board before making changes.

Default Parameters:

The BMS comes with default parameters for Li-ion, LiFePo4, and LTO battery types. These can be customized as needed.

ParameterLi-ion DefaultLiFePo4 DefaultLTO DefaultUnit
Balancing Initial Voltage332V
Maximum Balancing Current1/21/21/2A
Unit Overcharge Voltage4.23.62.7V
Unit Overcharge Protection Recovery4.173.542.64V
Monomer Undervoltage Protection2.822.61.8V
Monomer Undervoltage Protection Recovery2.852.651.85V
Automatic Shutdown Voltage2.82.51.7V
Charging Overtemperature Protection707070°C
Charging Low Temperature Protection-20-20-20°C
Short-circuit Protection Delay555µS

5.3. LED Indicators:

The interface board features LED indicators to help you monitor the BMS status and remaining battery power. The table below describes the LED behavior.

StatusNormal, Alarm, or ProtectionON/OFF IndicatorRUNALML1-L6 (Capacity/Status)Instructions
Power OffNormalOFF
BalanceNormalONFlickerOFFBattery based display
Charging (Normal)NormalONFlickerOFFBattery based display
Charging (Overcurrent, Overtemp, Overvoltage)AlarmONFlickerFlickerBattery based display
Discharging (Normal)NormalONFlickerOFFBattery based display
Discharging (Overcurrent, Overtemp, Undervoltage)AlarmONFlickerFlickerBattery based display
Other Alarms (Password not changed, Short circuit, Temperature)AlarmONFlickerFlickerBattery based display

Capacity Indicator LEDs (L1-L5):

Electric Quantity (%)Charging (L5-L1)Discharging (L5-L1)
0-20%OFFOFFOFFOFFONOFFOFFOFFOFFON
20-40%OFFOFFOFFONONOFFOFFOFFONON
40-60%OFFOFFONONONOFFOFFONONON
60-80%OFFONONONONOFFONONONON
80-100%ONONONONONONONONONON

Note: ON indicates that the LED is on, OFF indicates that the LED is off.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your JIKONG Inverter BMS. While the BMS is designed for durability, periodic checks are recommended.

6.1. General Maintenance Tips:

  • Visual Inspection: Periodically inspect all wiring and connections for any signs of wear, corrosion, or loose contacts.
  • Cleanliness: Keep the BMS and surrounding area clean and free from dust and debris to ensure proper heat dissipation.
  • Firmware Updates: Check the JIKONG official website or APP for any available firmware updates to ensure your BMS has the latest features and bug fixes.
  • Parameter Review: Occasionally review your BMS parameters via the APP or PC software to ensure they are still appropriate for your battery system and usage patterns.

7. Troubleshooting

The JIKONG Inverter BMS is equipped with multiple protection features to safeguard your battery system. If the BMS enters a protection state or exhibits abnormal behavior, refer to the following information.

7.1. Common Protection Triggers:

  • Overcharge Protection: Triggered if any cell voltage exceeds the set overcharge protection voltage during charging. The BMS will stop charging. It will resume when all cell voltages drop below the recovery voltage.
  • Discharge Undervoltage Protection: Triggered if any cell voltage drops below the set undervoltage protection voltage during discharge. The BMS will stop discharging. It will resume when all cell voltages rise above the recovery voltage. If a cell drops below the automatic shutdown voltage, the BMS will shut down.
  • Overcurrent Protection (Charge/Discharge): Triggered if the charging or discharging current exceeds the set continuous current for a specified delay. The BMS will stop the respective operation and resume after the overcurrent release time.
  • Overtemperature Protection (Charge/Discharge): Triggered if the temperature exceeds the set overtemperature protection value. The BMS will stop the respective operation and resume when the temperature drops below the recovery value.
  • Low Temperature Protection (Charge): Triggered if the temperature drops below the set low temperature protection value during charging. The BMS will stop charging and resume when the temperature rises above the recovery value. Consider using the heating function in cold environments.
  • Short Circuit Protection: Triggered by a sudden high current event. The BMS will cut off power. It will recover after a set delay. If this occurs during initial charger connection, it might be due to a peak current from the charger; increasing the short circuit protection delay may help. If it occurs with a load, ensure no external short circuits exist.
  • Emergency Switch: If the BMS encounters issues like over-temperature, over-discharge, over-charge, or cell imbalance during normal use, activating the emergency switch via the APP will enable charge and discharge for 30 minutes, providing a temporary operational window.
  • Intelligent Sleep: If the BMS enters intelligent sleep mode (charging/discharging current less than 1A for 26 consecutive hours), it can be reactivated by pressing the button (if connected) or by connecting a charger.

7.2. LED Alarm Indicators:

Refer to the LED Indicators table in Section 5.3 for specific alarm indications (RUN and ALM LEDs flickering).

8. User Tips

  • Initial Setup: Always double-check all wiring connections before powering on the BMS for the first time. Incorrect wiring can cause damage.
  • App Connectivity: Ensure your mobile device's Bluetooth is enabled and within range for stable connection to the BMS app.
  • Parameter Customization: Take time to understand and customize the protection parameters (e.g., voltage limits, current limits, temperature thresholds) to match your specific battery chemistry and application requirements.
  • Parallel Operation: When using multiple BMS units in parallel, correctly set the unique address for each unit using the DIP switches as described in Section 4.5.
  • Low Temperature Operation: If operating in cold climates, utilize the heating function to maintain optimal battery performance and prevent low-temperature charging issues.

9. Further Information and Support

For detailed technical information, advanced parameter settings, and comprehensive troubleshooting guides, please refer to the full PDF user manual:

Download Full User Manual (PDF)

This PDF contains in-depth diagrams, pinout details, and software operation instructions.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.