1. Introduction
The BSIDE O9 is a versatile, high-performance 3-in-1 handheld device that integrates the functions of a dual-channel oscilloscope, a digital multimeter, and a function signal generator. It features an advanced FPGA+MCU+ADC hardware architecture, ensuring reliable and accurate measurements.
Equipped with a 3.98-inch 480*320px resolution full-view high-definition TFT display, the O9 provides clear and detailed readings. Its robust design includes a built-in high-voltage protection module, supporting peak voltage measurements up to ±400V, and intelligent burn prevention for enhanced safety.
The device is powered by a built-in 5000mAh rechargeable lithium battery, offering approximately 10 hours of continuous operation in oscilloscope mode and up to 24 hours in multimeter mode, ensuring long-lasting performance for various tasks.
The BSIDE O9 is designed for both electrical professionals and DIY enthusiasts, providing a comprehensive solution for testing, troubleshooting, and signal generation needs.
2. Package Contents
Please check the package carefully to ensure all items are present and undamaged:
- 1 x BSIDE O9 Handheld Oscilloscope Multimeter
- 1 x EVA Carrying Case
- 2 x Oscilloscope Probes
- 1 x Oscilloscope Accessory Kit
- 1 x Multimeter Test Leads (pen)
- 1 x Crocodile Clip
- 1 x Packaging Box
- 1 x USB Charging Cable
- 1 x Instruction Manual
- 1 x Warranty Card
- 1 x K-Type Thermocouple

3. Product Overview
The BSIDE O9 features a user-friendly interface and robust construction. Key components include:
- Display Screen: A 3.98-inch TFT full-view color screen (480*320 pixels) for clear data visualization.
- Input Ports: Dedicated CH1 and CH2 inputs for oscilloscope functions, and multimeter measurement input ports.
- Output Port: A signal generator output port (OSC Port).
- USB Interface: For charging and data export.
- Button Board: Intuitive controls including F1-F4 function keys, CH1/2 switch, MENU, x1/x10 attenuation, AC/DC mode, AUTO PEAK, SAVE, and power button.
- Protective Sheath: Full body silicone sheath provides anti-burn and anti-fall protection.


4. Initial Setup and Charging
4.1 Charging the Device
The BSIDE O9 comes with a built-in 5000mAh lithium battery. Before first use, or when the low battery alarm indicates, charge the device using the provided USB charging cable.
- Connect the small end of the USB charging cable to the USB interface on the BSIDE O9.
- Connect the larger end of the USB cable to a standard USB power adapter (not included) or a computer's USB port.
- The charging indicator on the device will show the charging status. Ensure the device is fully charged for optimal performance.

4.2 Powering On/Off
To power on the device, press and hold the power button until the screen illuminates. To power off, press and hold the power button again until the device shuts down.
5. Operating Modes
The BSIDE O9 offers three primary operating modes: Oscilloscope, Multimeter, and Signal Generator. Use the 'MODE' button to switch between these functions.

5.1 Oscilloscope Function
The oscilloscope mode provides dual-channel waveform display with a 50MHz bandwidth and a 250MSa/s real-time sampling rate. It features an automatic range waveform function for ease of use.
- Connect the oscilloscope probes to the CH1 and/or CH2 input ports.
- Connect the probe tips to the circuit or signal source you wish to measure.
- Press the 'MODE' button to select the oscilloscope interface.
- Use the 'CH1/2' button to switch between channels or view both simultaneously.
- Utilize the 'MENU' button to access settings for trigger, time base, vertical sensitivity, and other parameters.
- The 'AUTO PEAK' button can automatically adjust the display for optimal waveform viewing.
- Use the navigation buttons (up, down, left, right) to adjust waveform position and cursor measurements.

5.2 Multimeter Function
The digital multimeter mode offers 20000 counts with True RMS measurement capabilities. It supports a wide range of electrical measurements:
- AC/DC Voltage
- AC/DC Current (including flexible current clamp support for up to 2000A)
- Resistance
- Capacitance
- Temperature (using K-Type Thermocouple)
- Diode Test
- Continuity Test
- Connect the multimeter test leads to the appropriate input ports (e.g., VΩmA for voltage/resistance/current, COM for common ground).
- Press the 'MODE' button to select the multimeter interface.
- Select the desired measurement function (e.g., AC V, DC V, Ω, A) using the function buttons or 'MENU' if applicable.
- Place the test leads across the component or circuit to take a reading.

5.3 Signal Generator Function
The built-in DDS function signal generator can output 7 types of waveforms with adjustable frequency, amplitude, and duty cycle. The maximum output frequency for all signals is 2MHz, with a step size of 1Hz.
- Available Waveforms: Sine wave, Half wave, Square wave, Direct current, Full wave, Triangle wave, Sawtooth wave.
- Press the 'MODE' button to navigate to the signal generator function (if available as a distinct mode, otherwise it might be integrated into oscilloscope output).
- Connect a suitable cable from the 'OSC Port' output to the device or circuit requiring the signal.
- Use the function buttons or menu options to select the desired waveform type.
- Adjust the output frequency, amplitude, and duty cycle as needed.

6. Data Management
6.1 Waveform Saving
The BSIDE O9 allows for one-click waveform screenshot saving. The device supports storing up to 36 records.
- While in oscilloscope mode, press the 'SAVE' button to capture the current waveform display.
- The saved image can be viewed directly on the oscilloscope.

6.2 Data Export
Saved waveforms and other data can be exported to a computer for further analysis.
- Connect the BSIDE O9 to a computer using the provided USB charging cable.
- The device should appear as a removable storage device on your computer.
- Access the stored data files (e.g., waveform screenshots) and copy them to your computer.

7. Specifications
7.1 General Specifications
- Model Number: O9
- Brand Name: BSIDE
- DIY Supplies: Electrical
- Certification: CE, FCC, RoHS
- Origin: Mainland China
- Display Size: 3.0 - 4.9 Inches (3.98-inch TFT full-view color screen)
- Display Resolution: 480*320 pixels
- Power: 5000mAh (Built-in Lithium Battery)
- Size: 216.6*84.5*36.0mm
- Weight: 384g
- Battery Included: Yes
- IS Battery Demountable: No
7.2 Oscilloscope Parameters
| Characteristic | Explanation |
|---|---|
| Bandwidth | Dual channel real-time sampling, 50MHz |
| Sampling Method | Real-time sampling |
| Real Time Sampling Rate | 250MSa/s |
| Number of Channels | 2 (Dual channel DC and AC) |
| Input Coupling | DC, AC |
| Input Impedance | 1MΩ, @16pF |
| Probe Attenuation | X1, X10 |
| Maximum Input Voltage | X1 range <150V, X10 range <300V (DC+AC Peak) |
| Sampling Rate Interpolation | (sinx)x |
| Scanning Speed Range | 100ns/div - 20s/div |
| Time Base Accuracy | 20ppm |
| Record Length | Highest 128KByte |
| Vertical Sensitivity | 20mV/div - 10V/div |
| Displacement Range | 4 grids (positive and negative) |
| Low Frequency Response | Greater than 10Hz |
| Rise Time | Less than 10ns |
| DC Gain Accuracy | ±3% |
| Automatic Measurement | Period, Frequency, Peak to Peak value, Maximum value, Minimum value, Duty cycle, Root Mean Square |
| Trigger Method | Automatic, Normal, Single Line |
| Trigger Edge | Rising edge, Falling edge |
| Display Mode | YT, Xy, Rolling |
| Afterglow Time | Min, 500ms, 1S, 10S, Infinite |
| Waveform Output Type | Sine wave, Square wave, Triangular wave, Half wave, Full wave, Sawtooth wave, DC |
| Frequency Range | 0Hz-2MHz |
| Output Channel | 1 |
| Output Amplitude | 0.1V-3.0V |
| Minimum Resolution | 1Hz |
| Square Wave Duty Cycle | 1%-99% |

7.3 Multimeter Parameters
| Function | Range | Resolving Power | Accuracy |
|---|---|---|---|
| DC Voltage (V) | 1000V | 0.001V | ±(0.05%+3) |
| DC Voltage (mV) | 200mV | 0.01mV | ±(0.1%+3) |
| AC Voltage (V) | 750V | 0.001V | ±(0.05%+3) |
| AC Voltage (mV) | 200mV | 0.01mV | ±(0.1%+3) |
| DC Current (mA) | 200mA | 0.01mA | ±(0.1%+3) |
| AC Current (mA) | 200mA | 0.01mA | ±(0.1%+3) |
| AC Current (A) (Flexible coil) | 2000A | 0.1A | ±(0.1%+3) |
| Resistance | 200MΩ | 0.001MΩ | ±(0.5%+3) |
| Capacitance | 99.999mF | 0.001mF | ±(4.0%+10) |
| Temperature | -20~1000°C / -4~1832°F | 1°C/°F | ±(2.0%+5) |
| Diode | Yes | On/Off | Yes |
| True Effective Value | Yes | Screen backlight | Yes |
| Low Battery Warning | Yes | Automatic shutdown | Yes |
| Battery Type | 5000mAh Lithium battery |

8. Safety Information
The BSIDE O9 is designed with user safety in mind, incorporating several protective features:
- Intelligent Burn Prevention: This feature helps prevent damage to the meter from overload during high-precision measurements, making it safer for both experienced users and beginners.
- High-Voltage Protection Module: Built-in protection supports maximum peak voltage measurements of ±400V.
- Silicone Sheath: The full body silicone sheath provides physical protection against daily bumps and falls.
Always adhere to standard electrical safety practices when using the device. Do not attempt to measure voltages or currents beyond the specified limits. Ensure test leads are in good condition before use.

9. User Tips
- Flexible Current Clamp: For measuring high AC currents (up to 2000A), the BSIDE O9 is compatible with the optional BSIDE TP01 Flexible Current Clamp. This accessory is sold separately and can significantly extend the current measurement capabilities of your device.
- Data Review: Regularly export saved waveforms to your computer for detailed analysis and record-keeping. This is especially useful for tracking changes over time or documenting specific events.
- Battery Life: To maximize battery life, ensure the device is fully charged before extended use. The automatic shutdown feature helps conserve power when the device is idle.
10. Troubleshooting
If you encounter issues with your BSIDE O9, please refer to the following common problems and solutions:
- Device does not power on: Ensure the battery is sufficiently charged. Connect the device to a power source using the USB cable and allow it to charge for at least 30 minutes before attempting to power on again.
- Inaccurate readings: Check that the test leads or probes are correctly connected and not damaged. Verify that the correct measurement mode is selected for the task. For oscilloscope measurements, ensure proper probe attenuation (x1/x10) is set.
- Screen is blank or frozen: Try restarting the device by holding down the power button until it shuts off, then power it back on. If the issue persists, ensure the battery is charged.
- Cannot save or export data: Check the available storage on the device. Ensure the USB connection to the computer is stable and recognized. Try using a different USB port or cable.
- Flexible Current Clamp not working: Ensure the clamp is correctly connected to the device and the appropriate current measurement mode is selected. Verify the clamp itself is not damaged.
If these steps do not resolve your issue, please contact customer support.
11. Maintenance
11.1 Cleaning
To maintain the accuracy and longevity of your BSIDE O9:
- Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Ensure all ports are free of dust and debris.
- Keep the display screen clean and free from scratches.
11.2 Storage
When not in use, store the device in its EVA carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Remove test leads and probes before storing.
12. Warranty and Support
The BSIDE O9 comes with a 12-month warranty from the date of purchase, covering manufacturing defects. Please refer to the included warranty card for detailed terms and conditions.
For technical support, troubleshooting assistance, or warranty claims, please contact the BSIDE Official Store customer service. Keep your purchase receipt and warranty card handy when contacting support.

13. Optional Accessories
To expand the capabilities of your BSIDE O9, consider the optional BSIDE TP01 Flexible Current Clamp. This accessory is designed for measuring high AC currents up to 2000A and is suitable for use with the O9 model.
You can acquire the BSIDE TP01 Flexible Current Clamp from the official seller's store. For more information or to purchase, please visit: https://www.aliexpress.com/item/1005008227777921.html