1. Introduction
The TSUN MA06L Magnetic Grid Displacement Digital Display Table is a precision measurement device designed for industrial applications, particularly for use with cutting machines. It provides accurate real-time displacement readings by working in conjunction with a magnetic grid ruler and a built-in sensor. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your MA06L unit.

2. Setup
Proper installation is crucial for accurate measurements. Follow these steps to set up your MA06L unit:
- Mounting the Display Unit: The MA06L display unit is designed for fixed-type mounting. Securely attach the display unit to a stable surface near your cutting machine or application area. Ensure it is positioned for easy viewing and access to controls.
- Installing the Magnetic Grid Ruler: Install the magnetic grid ruler parallel to the axis of motion you wish to measure. Ensure the ruler is clean and free from debris.
- Attaching and Aligning the Sensor: The MA06L uses a built-in sensor that reads the magnetic grid ruler. Attach the sensor securely to the moving part of your machine. Carefully align the sensor with the magnetic grid ruler, maintaining the recommended gap (if specified, otherwise ensure close proximity without contact) for optimal reading.
- Connecting the Sensor: Connect the sensor cable to the designated port on the MA06L digital display unit. Ensure the connection is firm and secure.

3. Operating Instructions
Once the MA06L is set up, follow these steps for operation:
- Power On: Connect the MA06L unit to its power source. The display should illuminate.
- Unit Selection (mm/inch): Press the "mm/inch" button to toggle between millimeter and inch measurement units. The selected unit will be indicated on the display.
- Absolute/Relative Measurement (ABS/REL):
- Press "ABS" for absolute measurement, which provides readings from a fixed zero point.
- Press "REL" for relative measurement, allowing you to set a temporary zero point at any position for incremental measurements.
- Zeroing the Display: To set the current position as zero, press the appropriate zeroing button (often combined with ABS/REL or a dedicated button, refer to the specific button layout on your unit).
- Taking Measurements: Move the machine part to which the sensor is attached. The display will show the real-time displacement value.
Watch the video below for a demonstration of the MA06L in operation:
4. Maintenance
To ensure the longevity and accuracy of your TSUN MA06L unit, follow these maintenance guidelines:
- Cleaning: Regularly clean the display unit and the magnetic sensor with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the surfaces or electronic components.
- Sensor and Ruler: Keep the magnetic grid ruler and the sensor head free from dust, chips, oil, and other contaminants. Even small particles can affect measurement accuracy.
- Cable Inspection: Periodically check the sensor cable for any signs of wear, cuts, or damage. Replace damaged cables immediately to prevent electrical issues or loss of signal.
- Environmental Protection: Protect the unit from excessive moisture, extreme temperatures, and direct impact. Store in a dry, stable environment when not in use.
5. Troubleshooting
If you encounter issues with your MA06L unit, refer to the following troubleshooting guide:
| Problem | Possible Cause | Solution |
|---|---|---|
| Display shows "E07" error |
|
|
| Inaccurate or inconsistent readings |
|
|
| Display not turning on |
|
|

6. Specifications
| Feature | Detail |
|---|---|
| Model Number | MA06L |
| Type | Digital Displacement Display |
| Mounting Type | Fixed type |
| Matching Sensor | Built-in sensor for magnetic grid ruler |
| Measurement Units | Millimeters (mm), Inches (inch) |
| Measurement Modes | Absolute (ABS), Relative (REL) |
| Display Unit Dimensions (approx.) | 67.6mm x 73.7mm x 36.2mm |
| Origin | Mainland China |

7. User Tips
While no specific user reviews or Q&A were provided, here are some general tips for optimizing your experience with the TSUN MA06L:
- Initial Calibration: Always perform an initial zero-setting or calibration after installation to ensure the accuracy of your measurements.
- Stable Environment: Operate the unit in a stable environment, free from excessive vibrations or sudden temperature changes, which can affect precision.
- Cable Management: Route sensor cables carefully to avoid pinching, stretching, or entanglement with moving machine parts. This prevents damage and ensures consistent signal transmission.
- Regular Checks: Periodically check the sensor-to-ruler gap and alignment, especially if the machine undergoes heavy use or experiences impacts.
8. Warranty and Support
For information regarding warranty coverage, technical support, or service inquiries, please contact the seller or manufacturer directly. Ensure you have your product model number (MA06L) and purchase details available when seeking assistance.