1. Product Overview
The JIKONG JKBMS V19 is an intelligent active balancing battery management system designed for large capacity series lithium battery packs. It integrates advanced features for voltage acquisition, high current active balancing, and comprehensive protection mechanisms.
This BMS is suitable for various battery chemistries including Lithium Iron Phosphate (LiFePO4), Ternary Lithium (Li-ion), and Lithium Titanate (LTO) batteries, supporting configurations from 8S to 16S (24V to 48V systems).
The core technology of the JKBMS V19 is its energy transfer active balancing, which ensures battery consistency, prolongs battery life, and improves overall battery performance. It features a compact design, simple operation, and full functionality, making it ideal for high-power energy storage, base station backup power, and solar power station battery packs.

2. Key Features and Functional Characteristics
The JKBMS V19 offers a robust set of features to ensure optimal battery performance and safety:
- Active Balancing: Achieves lossless balancing through energy transfer, moving energy from cells with higher voltage to those with lower voltage, with 1A or 2A balancing current options.
- Comprehensive Protection: Includes Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection, Over Temperature Protection, and Low Temperature Protection.
- Monitoring & Control: Features a Bluetooth module for mobile APP (Android, iOS, HarmonyOS) remote operation, PC software for monitoring, and support for information screen displays.
- Communication Interfaces: Equipped with RS485, CAN, and UART for versatile integration with inverters and other systems.
- Heating Function: Standard heating function to prevent battery activity reduction in low temperatures.
- Dry Contact Function: Two dry contacts for controlling external devices like alarms or cooling fans.
- Parallel Charging Current Limiting: Integrated 10A current limiting module for safe parallel connection of multiple battery packs.
- Accurate Measurements: High precision voltage acquisition (±3mV) and current acquisition.
- Intelligent Sleep: Reduces self-consumption when the BMS is in standby.

3. Installation and Wiring
3.1. Packing List
Please verify the contents of your package upon receipt. The standard package includes:
- BMS x 1
- Interface board x 1
- Adapter cable B x 1 (long 30cm)
- Adapter cable A x 1 (long 30cm)
- RS45 Network cable x 1 (long 40cm)
- Cells total B+ Cable x 1 (long 50cm)
- Sampling line A x 2 (long 90cm)
- Sampling line B x 1 (long 90cm)
- Sampling line C x 1 (long 90cm)
- Switch x 1 (long 50cm)
- Adapter cable C x 1 (long 30cm)
- Heating Adapter cable x 1 (long 17cm)
- Adapter x 1

3.2. Device Activation
Before powering on the protection board, ensure all balance cables are correctly connected, and the P- and B- terminals are securely wired. Confirm the protection board is firmly fixed to the battery core. Incorrect connections can lead to abnormal operation or damage.
The JKBMS V19 is designed for charging activation. After battery assembly, connect a charger (with voltage 2V higher than battery voltage) to activate the BMS. Alternatively, if a display screen and button are used, simply connect the cable to the display interface and press the button to activate.
3.3. Wiring Instructions
The JKBMS V19 is suitable for 7-16 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack. Always ensure correct polarity and secure connections.

Important Wiring Notes:
- Connect all balance cables to each battery cell.
- Insert the main cable into the BMS.
- Connect the B-line and P-line to the battery.
- If there are two B8 cables, only the first B8 cable needs to be connected. The second B8 cable is not needed.
3.4. Interface Board Functions
The interface board provides LED indicators, a reset switch, DIP switches, dry contacts, and communication ports:
- LED Indicators: Help determine BMS status and remaining battery power.
- Reset Button: Used to reset the BMS in case of malfunction.
- DIP Switches: For setting the address when using multiple BMS units in parallel (0-15 addresses).
- Dry Contacts: Control external alarms or cooling fans.
- CAN & RS485-1: For communication with inverters.
- RS485-2: For parallel battery pack communication and connection to a host computer.

4. Operation
4.1. Mobile APP and PC Software
The JKBMS V19 can be monitored and controlled via a mobile APP (Android, iOS, HarmonyOS) or PC software. Scan the QR code below to download the mobile APP. Android Version 7 or higher is required.

Through the APP or PC software, you can:
- View real-time battery status (voltage, current, temperature, SOC).
- Modify protection parameters (e.g., overcharge/discharge voltage, current limits).
- Control charge and discharge switches.
- Set up inverter communication protocols.

4.2. Display Screen Operation
The JKBMS V19 supports optional 3.2-inch or 4.3-inch touch screen displays for convenient local monitoring and control. These displays provide a clear interface for viewing battery information and adjusting settings.


A long press on the switch cable connected to the display can turn the BMS on or off.
4.3. Parallel Function
The parallel function allows simultaneous monitoring of multiple JKBMS units via an RS485 bus and a host computer. Up to 16 BMS units can be connected. Each BMS must have a unique address (0-15) set via DIP switches. BMS with address 0 acts as the host, and others as slaves.

5. Protection and Recovery
The JKBMS V19 is equipped with various protection mechanisms that automatically trigger and recover to ensure battery safety and longevity.
5.1. Overcharge Protection and Recovery
When any cell's voltage exceeds the set overcharge protection voltage during charging, the BMS will stop charging. Charging resumes when all cell voltages drop below the overcharge recovery voltage.
5.2. Overdischarge Protection and Recovery
If any cell's voltage falls below the undervoltage protection voltage during discharge, the BMS will cut off discharge. Discharge resumes when the battery is charged and all cell voltages exceed the undervoltage recovery voltage. The BMS will automatically shut down if any cell voltage drops below the automatic shutdown voltage.
5.3. Overcurrent Protection and Recovery (Charge/Discharge)
If the charging or discharging current exceeds the set continuous current for a specified delay, the BMS will trigger overcurrent protection and stop the respective operation. The operation will resume after the overcurrent release time.
5.4. Over/Low Temperature Protection and Recovery
The BMS monitors battery temperature. If the temperature exceeds the over-temperature protection value (during charge or discharge) or falls below the low-temperature protection value (during charge), the BMS will stop the respective operation. Operation resumes when the temperature returns to within the safe recovery range.
5.5. Short Circuit Protection and Recovery
The BMS includes short circuit protection. If a short circuit is detected, the BMS will cut off power. Recovery occurs after a set delay. Users can adjust the short circuit protection delay and recovery time via the APP if needed, especially when connecting new loads with high instantaneous current draw.5.6. Intelligent Sleep
The intelligent sleep function automatically puts the BMS into a low-power state if the charging/discharging current is less than 1A for 26 consecutive hours. This reduces the BMS's self-consumption. To reactivate, press the button on the display or connect a charger.
6. Troubleshooting and Indicators
The JKBMS V19 provides LED indicators and detailed APP/PC software diagnostics to assist with troubleshooting.
6.1. LED Indicators
The interface board features LED indicators for Bluetooth status, RUN, ALM, and battery capacity (L1-L5). Refer to the table below for their meanings:
| Status | Condition | ON/OFF Indicator | RUN | ALM | L1-L5 (Capacity) | Instructions | |
|---|---|---|---|---|---|---|---|
| Power Off | Normal | OFF | |||||
| Balance | Normal | ON | Flicker | OFF | Based on power display | ||
| Charging | Overcurrent, Overtemp, Overvoltage, Charging Failure | ON | Flicker | Flicker | Based on power display | ||
| Discharging | Overcurrent, Overtemp, Undervoltage, Discharge Failure | ON | Flicker | Flicker | Based on power display | ||
| Other Alarm | Password not changed, Short Circuit, Temperature | ON | Flicker | Flicker | Based on power display | ||
Note: 'ON' indicates the LED is on, 'OFF' indicates the LED is off. 'Flicker' indicates flashing.
6.2. APP/PC Software Diagnostics
The mobile APP and PC software provide real-time data and alarm logs, which are invaluable for diagnosing issues. If an alarm is triggered, the software will display the specific fault (e.g., overvoltage, overcurrent, temperature anomaly). Review the alarm history and current parameters to identify the root cause.

7. Product Specifications
7.1. General Parameters
| Technical Index | JK-PB1A16S-10P | JK-PB1A16S-15P | JK-PB2A16S-15P | JK-PB2A16S-20P | JK-PB2A16S-30P |
|---|---|---|---|---|---|
| Number of Battery Strings (Li-ion) | 7S-16S | ||||
| Number of Battery Strings (LiFePO4) | 8S-16S | ||||
| Number of Battery Strings (LTO) | 14S-16S | ||||
| Balance Method | Active Balance (Full State On) | ||||
| Balance Current | 1A | 1A | 2A | 2A | 2A |
| Conductive Resistance in Main Circuit | 1mΩ | 0.65mΩ | 0.65mΩ | 0.47mΩ | 0.25mΩ |
| Continuous Discharge Current | 100A | 150A | 150A | 200A | 300A |
| Maximum Discharge Current (MAX 2min) | 200A | 300A | 300A | 350A | 600A |
| Over Charge Protection Current (ADJ) | 200A | 300A | 300A | 350A | 600A |
| Other Interfaces (Default) | RS485/232/CAN/UART | ||||
| Supply Voltage | 20-70V | ||||
| Wiring Output | Common Port | ||||
| Single Cell Voltage Range | 1-5V | ||||
| Voltage Acquisition Accuracy | ±5mV | ||||
| Over Charge Protection Voltage | 1.2-4.35V Adjustable | ||||
| Over Charge Release Voltage | 1.2-4.35V Adjustable | ||||
| Over Current Detect Delay | 2-120S Adjustable | ||||
| Over Discharge Protection Voltage | 1.2-4.35V Adjustable | ||||
| Over Discharge Release Voltage | 1.2-4.35V Adjustable | ||||
| Quantity of Temperature Detection | 4 | ||||
| Temp Protection | Yes | ||||
| Short Circuit Protection | Yes | ||||
| Coulomb Counter | Yes | ||||
| Bluetooth Function | Support for Android/iOS/Harmony | ||||
| Parallel Charging Current Limiting | 10A | ||||
| Address Dial Switch | 4 | ||||
| DRY Contact | 2 | ||||

7.2. Dimensions
The JKBMS V19 protection board measures 300mm x 100mm x 24mm. The optional display screens have the following dimensions:
- 4.3-inch Touch Screen: Approximately 135.9mm x 88.5mm.
- 3.2-inch Display: Approximately 100mm x 62mm.


8. User Tips
- Check Package Contents: Always verify that all components listed in the packing list are included upon arrival to avoid delays in your project.
- Pre-Installation Check: Before powering on, double-check all balance cable connections and ensure the P- and B- terminals are correctly wired. Securely fix the BMS to the battery core.
- Cold Weather Operation: If operating in extremely cold areas, utilize the heating function to protect the battery cells and maintain optimal performance.
- Short Circuit Protection Adjustment: If short circuit protection triggers unexpectedly upon first connection of a charger or load, consider increasing the short circuit protection delay via the APP. This can accommodate high instantaneous current draws from certain loads or chargers.
- Parallel System Setup: When setting up a parallel system with multiple BMS units, ensure each unit has a unique address configured via the DIP switches (0 for host, 1-15 for slaves).
9. Support and Further Information
For detailed technical support, troubleshooting assistance, or further inquiries, please contact JIKONG Technology Co. LTD. You can also refer to the comprehensive PDF user manual for in-depth information:
Reference: JIKONG Energy Storage Series BMS Product Specification (PDF)
JIKONG Technology Co. LTD is committed to providing high-quality products and support for your energy storage needs.