1. Product Overview

The JIKONG JKBMS V19 is an intelligent active balancing battery management system designed for large capacity series lithium battery packs. It integrates advanced features for voltage acquisition, high current active balancing, and comprehensive protection mechanisms.

This BMS is suitable for various battery chemistries including Lithium Iron Phosphate (LiFePO4), Ternary Lithium (Li-ion), and Lithium Titanate (LTO) batteries, supporting configurations from 8S to 16S (24V to 48V systems).

The core technology of the JKBMS V19 is its energy transfer active balancing, which ensures battery consistency, prolongs battery life, and improves overall battery performance. It features a compact design, simple operation, and full functionality, making it ideal for high-power energy storage, base station backup power, and solar power station battery packs.

JIKONG Home Energy Storage BMS overview
JIKONG Home Energy Storage BMS Overview

2. Key Features and Functional Characteristics

The JKBMS V19 offers a robust set of features to ensure optimal battery performance and safety:

  • Active Balancing: Achieves lossless balancing through energy transfer, moving energy from cells with higher voltage to those with lower voltage, with 1A or 2A balancing current options.
  • Comprehensive Protection: Includes Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection, Over Temperature Protection, and Low Temperature Protection.
  • Monitoring & Control: Features a Bluetooth module for mobile APP (Android, iOS, HarmonyOS) remote operation, PC software for monitoring, and support for information screen displays.
  • Communication Interfaces: Equipped with RS485, CAN, and UART for versatile integration with inverters and other systems.
  • Heating Function: Standard heating function to prevent battery activity reduction in low temperatures.
  • Dry Contact Function: Two dry contacts for controlling external devices like alarms or cooling fans.
  • Parallel Charging Current Limiting: Integrated 10A current limiting module for safe parallel connection of multiple battery packs.
  • Accurate Measurements: High precision voltage acquisition (±3mV) and current acquisition.
  • Intelligent Sleep: Reduces self-consumption when the BMS is in standby.
Active Balancing (Lossless Balancing) diagram
Active Balancing (Lossless Balancing) Principle

3. Installation and Wiring

3.1. Packing List

Please verify the contents of your package upon receipt. The standard package includes:

  1. BMS x 1
  2. Interface board x 1
  3. Adapter cable B x 1 (long 30cm)
  4. Adapter cable A x 1 (long 30cm)
  5. RS45 Network cable x 1 (long 40cm)
  6. Cells total B+ Cable x 1 (long 50cm)
  7. Sampling line A x 2 (long 90cm)
  8. Sampling line B x 1 (long 90cm)
  9. Sampling line C x 1 (long 90cm)
  10. Switch x 1 (long 50cm)
  11. Adapter cable C x 1 (long 30cm)
  12. Heating Adapter cable x 1 (long 17cm)
  13. Adapter x 1
Packing List diagram
Contents of the JKBMS V19 Package

3.2. Device Activation

Before powering on the protection board, ensure all balance cables are correctly connected, and the P- and B- terminals are securely wired. Confirm the protection board is firmly fixed to the battery core. Incorrect connections can lead to abnormal operation or damage.

The JKBMS V19 is designed for charging activation. After battery assembly, connect a charger (with voltage 2V higher than battery voltage) to activate the BMS. Alternatively, if a display screen and button are used, simply connect the cable to the display interface and press the button to activate.

3.3. Wiring Instructions

The JKBMS V19 is suitable for 7-16 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack. Always ensure correct polarity and secure connections.

Wiring diagram for 16-string and 8-string cells
Wiring Diagram for 16-string and 8-string Cells

Important Wiring Notes:

  • Connect all balance cables to each battery cell.
  • Insert the main cable into the BMS.
  • Connect the B-line and P-line to the battery.
  • If there are two B8 cables, only the first B8 cable needs to be connected. The second B8 cable is not needed.

3.4. Interface Board Functions

The interface board provides LED indicators, a reset switch, DIP switches, dry contacts, and communication ports:

  • LED Indicators: Help determine BMS status and remaining battery power.
  • Reset Button: Used to reset the BMS in case of malfunction.
  • DIP Switches: For setting the address when using multiple BMS units in parallel (0-15 addresses).
  • Dry Contacts: Control external alarms or cooling fans.
  • CAN & RS485-1: For communication with inverters.
  • RS485-2: For parallel battery pack communication and connection to a host computer.
Interface board communication modes and interfaces
Interface Board Communication Modes and Ports

4. Operation

4.1. Mobile APP and PC Software

The JKBMS V19 can be monitored and controlled via a mobile APP (Android, iOS, HarmonyOS) or PC software. Scan the QR code below to download the mobile APP. Android Version 7 or higher is required.

Mobile APP link QR code
Mobile APP Download QR Code

Through the APP or PC software, you can:

  • View real-time battery status (voltage, current, temperature, SOC).
  • Modify protection parameters (e.g., overcharge/discharge voltage, current limits).
  • Control charge and discharge switches.
  • Set up inverter communication protocols.
Multi-screen display options for JIKONG BMS
Multi-screen Display Options (Mobile APP, PC Software, Home Storage Display)

4.2. Display Screen Operation

The JKBMS V19 supports optional 3.2-inch or 4.3-inch touch screen displays for convenient local monitoring and control. These displays provide a clear interface for viewing battery information and adjusting settings.

JIKONG V19 BMS with 4.3 Inch Touch Screen Display
JKBMS V19 with 4.3 Inch Touch Screen Display
4.3 inch Touch Screen Display interface
4.3 Inch Touch Screen Display Interface

A long press on the switch cable connected to the display can turn the BMS on or off.

4.3. Parallel Function

The parallel function allows simultaneous monitoring of multiple JKBMS units via an RS485 bus and a host computer. Up to 16 BMS units can be connected. Each BMS must have a unique address (0-15) set via DIP switches. BMS with address 0 acts as the host, and others as slaves.

JIKONG BMS monitoring platform screenshot for parallel connection
JIKONG BMS Monitoring Platform for Parallel Connection

5. Protection and Recovery

The JKBMS V19 is equipped with various protection mechanisms that automatically trigger and recover to ensure battery safety and longevity.

5.1. Overcharge Protection and Recovery

When any cell's voltage exceeds the set overcharge protection voltage during charging, the BMS will stop charging. Charging resumes when all cell voltages drop below the overcharge recovery voltage.

5.2. Overdischarge Protection and Recovery

If any cell's voltage falls below the undervoltage protection voltage during discharge, the BMS will cut off discharge. Discharge resumes when the battery is charged and all cell voltages exceed the undervoltage recovery voltage. The BMS will automatically shut down if any cell voltage drops below the automatic shutdown voltage.

5.3. Overcurrent Protection and Recovery (Charge/Discharge)

If the charging or discharging current exceeds the set continuous current for a specified delay, the BMS will trigger overcurrent protection and stop the respective operation. The operation will resume after the overcurrent release time.

5.4. Over/Low Temperature Protection and Recovery

The BMS monitors battery temperature. If the temperature exceeds the over-temperature protection value (during charge or discharge) or falls below the low-temperature protection value (during charge), the BMS will stop the respective operation. Operation resumes when the temperature returns to within the safe recovery range.

5.5. Short Circuit Protection and Recovery

The BMS includes short circuit protection. If a short circuit is detected, the BMS will cut off power. Recovery occurs after a set delay. Users can adjust the short circuit protection delay and recovery time via the APP if needed, especially when connecting new loads with high instantaneous current draw.5.6. Intelligent Sleep

The intelligent sleep function automatically puts the BMS into a low-power state if the charging/discharging current is less than 1A for 26 consecutive hours. This reduces the BMS's self-consumption. To reactivate, press the button on the display or connect a charger.

6. Troubleshooting and Indicators

The JKBMS V19 provides LED indicators and detailed APP/PC software diagnostics to assist with troubleshooting.

6.1. LED Indicators

The interface board features LED indicators for Bluetooth status, RUN, ALM, and battery capacity (L1-L5). Refer to the table below for their meanings:

LED Status Description
StatusConditionON/OFF IndicatorRUNALML1-L5 (Capacity)Instructions
Power OffNormalOFF
BalanceNormalONFlickerOFFBased on power display
ChargingOvercurrent, Overtemp, Overvoltage, Charging FailureONFlickerFlickerBased on power display
DischargingOvercurrent, Overtemp, Undervoltage, Discharge FailureONFlickerFlickerBased on power display
Other AlarmPassword not changed, Short Circuit, TemperatureONFlickerFlickerBased on power display

Note: 'ON' indicates the LED is on, 'OFF' indicates the LED is off. 'Flicker' indicates flashing.

6.2. APP/PC Software Diagnostics

The mobile APP and PC software provide real-time data and alarm logs, which are invaluable for diagnosing issues. If an alarm is triggered, the software will display the specific fault (e.g., overvoltage, overcurrent, temperature anomaly). Review the alarm history and current parameters to identify the root cause.

JIKONG BMS monitoring platform screenshot
JIKONG BMS Monitoring Platform (Example)

7. Product Specifications

7.1. General Parameters

JKBMS V19 Product Specifications
Technical IndexJK-PB1A16S-10PJK-PB1A16S-15PJK-PB2A16S-15PJK-PB2A16S-20PJK-PB2A16S-30P
Number of Battery Strings (Li-ion)7S-16S
Number of Battery Strings (LiFePO4)8S-16S
Number of Battery Strings (LTO)14S-16S
Balance MethodActive Balance (Full State On)
Balance Current1A1A2A2A2A
Conductive Resistance in Main Circuit1mΩ0.65mΩ0.65mΩ0.47mΩ0.25mΩ
Continuous Discharge Current100A150A150A200A300A
Maximum Discharge Current (MAX 2min)200A300A300A350A600A
Over Charge Protection Current (ADJ)200A300A300A350A600A
Other Interfaces (Default)RS485/232/CAN/UART
Supply Voltage20-70V
Wiring OutputCommon Port
Single Cell Voltage Range1-5V
Voltage Acquisition Accuracy±5mV
Over Charge Protection Voltage1.2-4.35V Adjustable
Over Charge Release Voltage1.2-4.35V Adjustable
Over Current Detect Delay2-120S Adjustable
Over Discharge Protection Voltage1.2-4.35V Adjustable
Over Discharge Release Voltage1.2-4.35V Adjustable
Quantity of Temperature Detection4
Temp ProtectionYes
Short Circuit ProtectionYes
Coulomb CounterYes
Bluetooth FunctionSupport for Android/iOS/Harmony
Parallel Charging Current Limiting10A
Address Dial Switch4
DRY Contact2
JKBMS V19 Product Specifications Table
JKBMS V19 Product Specifications

7.2. Dimensions

The JKBMS V19 protection board measures 300mm x 100mm x 24mm. The optional display screens have the following dimensions:

  • 4.3-inch Touch Screen: Approximately 135.9mm x 88.5mm.
  • 3.2-inch Display: Approximately 100mm x 62mm.
JIKONG 4.3 inch Touch Screen dimensions
4.3 Inch Touch Screen Display Dimensions
JIKONG 3.2 inch Display dimensions
3.2 Inch Display Dimensions

8. User Tips

  • Check Package Contents: Always verify that all components listed in the packing list are included upon arrival to avoid delays in your project.
  • Pre-Installation Check: Before powering on, double-check all balance cable connections and ensure the P- and B- terminals are correctly wired. Securely fix the BMS to the battery core.
  • Cold Weather Operation: If operating in extremely cold areas, utilize the heating function to protect the battery cells and maintain optimal performance.
  • Short Circuit Protection Adjustment: If short circuit protection triggers unexpectedly upon first connection of a charger or load, consider increasing the short circuit protection delay via the APP. This can accommodate high instantaneous current draws from certain loads or chargers.
  • Parallel System Setup: When setting up a parallel system with multiple BMS units, ensure each unit has a unique address configured via the DIP switches (0 for host, 1-15 for slaves).

9. Support and Further Information

For detailed technical support, troubleshooting assistance, or further inquiries, please contact JIKONG Technology Co. LTD. You can also refer to the comprehensive PDF user manual for in-depth information:

Reference: JIKONG Energy Storage Series BMS Product Specification (PDF)

JIKONG Technology Co. LTD is committed to providing high-quality products and support for your energy storage needs.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.