1. Introduction

This manual provides essential information for the safe and efficient use of your Jiayin JYPC-3C Electromagnetic Pump. Please read these instructions carefully before installation, operation, or maintenance to ensure proper function and longevity of the product.

Jiayin JYPC-3C Electromagnetic Pump

Figure 1: Jiayin JYPC-3C Electromagnetic Pump

2. Safety Instructions

Adherence to these safety guidelines is crucial for preventing injury and damage to the pump.

  • Power-Off Operation: Always disconnect the power supply before performing any installation, maintenance, or troubleshooting.
  • No Dry Running: Do not operate the pump without liquid. Dry running can cause severe damage to the pump components.
  • Liquid Only: Use only clean, particle-free liquid. Impurities can lead to clogging and reduce pump efficiency or cause failure.
  • Electrical Safety: Ensure the voltage and frequency of your power supply match the pump's specifications (AC 220V-240V, 50Hz).

2.1 Warnings

WARNING: CHOKING HAZARD

Small parts. Not suitable for children under 3 years. Keep out of reach of young children.

3. Specifications

The following table details the technical specifications of the Jiayin JYPC-3C Electromagnetic Pump:

FeatureSpecification
Model NumberJYPC-3C
Power SourceElectric
TheoryElectromagnetic Pump
StructurePiston Pump
PressureHigh Pressure
UsageWater, Sewage
OriginChina Mainland
CertificationNONE
Rated Power25W
Rated Flow140 ml/min
VoltageAC 220V-240V
Frequency50Hz
Maximum Pressure8 bar
Noise Level53 dB
EU LVD VoltageLow voltage: Below 50Vac or 75Vdc (Note: Product label indicates 220V-240V)
High-concerned chemicalNone
Batteries IncludedNot included
PrincipleSelf-priming supercharging
Application ScenarioHome use

3.1 Dimensions and Performance

Product dimensions and key specifications

Figure 2: Dimensions and Key Specifications (Length: 110mm, Coil Height: 48mm, Coil Width: 38.7mm)

Detailed technical drawing with port labels

Figure 3: Technical Drawing with G1/8 Outlet and Exhaust Port

Performance graphs for flow, pressure, and temperature

Figure 4: Performance Graphs (Flow/Pressure, Flow/Time, Temperature/Time)

3.2 Package Information

  • Length: 11 cm
  • Width: 1 cm
  • Height: 1 cm
  • Weight: 0.32 kg

4. Installation

Proper installation is critical for the pump's performance and safety.

  • Vertical Mounting: Ensure the pump is installed in a stable and upright position to prevent operational issues.
  • Inlet/Outlet Sealing: Securely seal all inlet and outlet connections to prevent liquid leakage during operation.
  • Inlet Filtration: Install a suitable filter at the inlet to prevent impurities from entering the pump and causing damage or clogging.

4.1 Wiring Diagram

Wiring diagram for the electromagnetic pump

Figure 5: Wiring Diagram

Connect the power supply wires to the terminals as indicated in the diagram. Ensure all connections are secure and insulated.

5. Operation

The Jiayin JYPC-3C is an electromagnetic piston pump designed for high-pressure water suction. It operates by converting electrical energy into mechanical energy to create a pulsating flow, effectively moving liquid through the system.

  • Ensure the pump is correctly installed and all connections are secure.
  • Verify that the liquid reservoir contains clean, particle-free liquid.
  • Connect the pump to a power source matching its voltage and frequency specifications (AC 220V-240V, 50Hz).
  • Activate the device the pump is integrated into. The pump will begin to draw liquid and generate pressure.

5.1 Wide Application

This pump is commonly used in various household and industrial appliances requiring precise liquid delivery and high pressure, such as:

Examples of applications for the electromagnetic pump

Figure 6: Wide Application Examples (e.g., Steam Irons, Dishwashers, Coffee Machines, Vacuum Packaging Machines)

6. Maintenance

Regular maintenance helps ensure optimal performance and extends the lifespan of your pump.

  • Inlet Filter: Periodically inspect and clean the inlet filter to prevent clogging from impurities. Replace if damaged.
  • Seals and Tubing: Check seals and tubing for wear, cracks, or leaks. Replace worn seals and tighten loose tubing connections as needed.
  • Pump Cleaning: If the pump is exposed to liquids that may leave residue, occasional cleaning of the internal components (e.g., plunger) may be necessary. Refer to specific appliance manuals for detailed cleaning procedures if the pump is integrated.

7. Troubleshooting

If you encounter issues with your pump, refer to the following troubleshooting steps:

ProblemPossible Cause / Solution
No Liquid Output
  • Bleed air from the system.
  • Clean the inlet filter.
  • Check the power supply connection.
Low Pressure
  • Replace worn seals.
  • Tighten tubing connections.
  • Remove any debris obstructing the flow.
Excessive Noise
  • Reinforce pump mounting to reduce vibration.
  • Clean the pump's internal components.
  • Replace the plunger if worn.

8. User Tips

  • Compatibility: This pump has been successfully used as a replacement part in various steam irons, including Philips PerfectCare and GC9642 models. Always verify the model number (JYPC-3C) for exact compatibility, as slight variations like 'JYPC-3' might exist.
  • Installation Ease: Many users report that replacing the pump is straightforward and can be done in a short amount of time, restoring full functionality to their appliances.
  • Temperature Considerations: While suitable for steam appliances, if replacing in a boiler-type system, ensure the pump's operating temperature range is compatible with your specific application.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

10. Additional Resources

10.1 Product Overview Video

Video 1: Product Overview and Demonstration

10.2 User Manual (PDF)

A detailed user manual in PDF format is available for download. This document contains further technical details and instructions.

Reference: Jiayin Miniature Electromagnetic Pump User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.