1. Introduction
This manual provides essential information for the safe and efficient use of your Jiayin JYPC-3C Electromagnetic Pump. Please read these instructions carefully before installation, operation, or maintenance to ensure proper function and longevity of the product.

Figure 1: Jiayin JYPC-3C Electromagnetic Pump
2. Safety Instructions
Adherence to these safety guidelines is crucial for preventing injury and damage to the pump.
- Power-Off Operation: Always disconnect the power supply before performing any installation, maintenance, or troubleshooting.
- No Dry Running: Do not operate the pump without liquid. Dry running can cause severe damage to the pump components.
- Liquid Only: Use only clean, particle-free liquid. Impurities can lead to clogging and reduce pump efficiency or cause failure.
- Electrical Safety: Ensure the voltage and frequency of your power supply match the pump's specifications (AC 220V-240V, 50Hz).
2.1 Warnings
WARNING: CHOKING HAZARD
Small parts. Not suitable for children under 3 years. Keep out of reach of young children.
3. Specifications
The following table details the technical specifications of the Jiayin JYPC-3C Electromagnetic Pump:
| Feature | Specification |
|---|---|
| Model Number | JYPC-3C |
| Power Source | Electric |
| Theory | Electromagnetic Pump |
| Structure | Piston Pump |
| Pressure | High Pressure |
| Usage | Water, Sewage |
| Origin | China Mainland |
| Certification | NONE |
| Rated Power | 25W |
| Rated Flow | 140 ml/min |
| Voltage | AC 220V-240V |
| Frequency | 50Hz |
| Maximum Pressure | 8 bar |
| Noise Level | 53 dB |
| EU LVD Voltage | Low voltage: Below 50Vac or 75Vdc (Note: Product label indicates 220V-240V) |
| High-concerned chemical | None |
| Batteries Included | Not included |
| Principle | Self-priming supercharging |
| Application Scenario | Home use |
3.1 Dimensions and Performance

Figure 2: Dimensions and Key Specifications (Length: 110mm, Coil Height: 48mm, Coil Width: 38.7mm)

Figure 3: Technical Drawing with G1/8 Outlet and Exhaust Port

Figure 4: Performance Graphs (Flow/Pressure, Flow/Time, Temperature/Time)
3.2 Package Information
- Length: 11 cm
- Width: 1 cm
- Height: 1 cm
- Weight: 0.32 kg
4. Installation
Proper installation is critical for the pump's performance and safety.
- Vertical Mounting: Ensure the pump is installed in a stable and upright position to prevent operational issues.
- Inlet/Outlet Sealing: Securely seal all inlet and outlet connections to prevent liquid leakage during operation.
- Inlet Filtration: Install a suitable filter at the inlet to prevent impurities from entering the pump and causing damage or clogging.
4.1 Wiring Diagram

Figure 5: Wiring Diagram
Connect the power supply wires to the terminals as indicated in the diagram. Ensure all connections are secure and insulated.
5. Operation
The Jiayin JYPC-3C is an electromagnetic piston pump designed for high-pressure water suction. It operates by converting electrical energy into mechanical energy to create a pulsating flow, effectively moving liquid through the system.
- Ensure the pump is correctly installed and all connections are secure.
- Verify that the liquid reservoir contains clean, particle-free liquid.
- Connect the pump to a power source matching its voltage and frequency specifications (AC 220V-240V, 50Hz).
- Activate the device the pump is integrated into. The pump will begin to draw liquid and generate pressure.
5.1 Wide Application
This pump is commonly used in various household and industrial appliances requiring precise liquid delivery and high pressure, such as:

Figure 6: Wide Application Examples (e.g., Steam Irons, Dishwashers, Coffee Machines, Vacuum Packaging Machines)
6. Maintenance
Regular maintenance helps ensure optimal performance and extends the lifespan of your pump.
- Inlet Filter: Periodically inspect and clean the inlet filter to prevent clogging from impurities. Replace if damaged.
- Seals and Tubing: Check seals and tubing for wear, cracks, or leaks. Replace worn seals and tighten loose tubing connections as needed.
- Pump Cleaning: If the pump is exposed to liquids that may leave residue, occasional cleaning of the internal components (e.g., plunger) may be necessary. Refer to specific appliance manuals for detailed cleaning procedures if the pump is integrated.
7. Troubleshooting
If you encounter issues with your pump, refer to the following troubleshooting steps:
| Problem | Possible Cause / Solution |
|---|---|
| No Liquid Output |
|
| Low Pressure |
|
| Excessive Noise |
|
8. User Tips
- Compatibility: This pump has been successfully used as a replacement part in various steam irons, including Philips PerfectCare and GC9642 models. Always verify the model number (JYPC-3C) for exact compatibility, as slight variations like 'JYPC-3' might exist.
- Installation Ease: Many users report that replacing the pump is straightforward and can be done in a short amount of time, restoring full functionality to their appliances.
- Temperature Considerations: While suitable for steam appliances, if replacing in a boiler-type system, ensure the pump's operating temperature range is compatible with your specific application.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.
10. Additional Resources
10.1 Product Overview Video
Video 1: Product Overview and Demonstration
10.2 User Manual (PDF)
A detailed user manual in PDF format is available for download. This document contains further technical details and instructions.
Reference: Jiayin Miniature Electromagnetic Pump User Manual (PDF)