1. Introduction
This manual provides essential information for the safe and efficient operation of your Anern AN-PVI Series Photovoltaic Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.

Key Features:
- Pure sine wave output.
- Configurable input voltage range for various applications via LCD settings.
- Compatibility with mains voltage.
- Automatic restart upon AC recovery.
- Integrated protection against overload, over-temperature, and short circuits.
- Cold start function.
- Dual MPPT for 6KW models and three MPPT for 10KW models.
- Capable of running 3-phase motors: 6KW model supports 3P motors, 10KW model supports 1.5P+3P motors.
- Designed for full load operation using solar power only.
- IP21 ingress protection.
- Maximum conversion efficiency of 97%.
- Important Note: This inverter does not support connection to batteries.
2. Setup and Installation
Proper installation is crucial for the safe and optimal performance of your inverter. Ensure all connections are secure and follow local electrical codes.
2.1 System Diagram
The following diagram illustrates a typical system setup for the Anern AN-PVI inverter, integrating solar panels, a generator, the utility grid, and various loads, including a water pump system.

2.2 Product Appearance and Connection Points
Familiarize yourself with the inverter's physical layout and connection terminals before proceeding with installation.

- Utility Input: Connects to the main utility grid.
- Photovoltaic Input (PV1, PV2, PV3): Connects to your solar panel arrays. Ensure correct polarity and voltage.
- Utility Output: Connects to your household or facility loads.
- Inverter Switch (ON/OFF): Main power switch for the inverter.
- CT Backflow Prevention Interface: For connecting a Current Transformer (CT) module, if required for grid-tie applications in your region.
- Ground Wire Terminal: Essential for safety grounding.
2.3 Pre-Installation Notes
- The inverter is designed for direct power conversion and cannot be connected to batteries.
- For PV-only operation (without mains power), the PV voltage must be greater than 150Vdc for the inverter to start.
- When connecting to a water pump, ensure the inverter's power capacity is 5-7 times greater than the water pump's power. This inverter is suitable only for domestic small water pumps.
- If connecting to the grid, ensure your local regulations do not require specific grid connection certifications that this inverter may not possess. A CT module may be required; please consult your supplier.
3. Operating Instructions
Follow these steps for safe and effective operation of your inverter.
3.1 Startup and Shutdown Sequence
- Startup: Always turn on the inverter first, then activate the connected loads.
- Shutdown: Always shut down the connected loads first, then turn off the inverter.
3.2 Output Source Priority Configuration
The inverter allows you to configure the priority of power sources for your loads. This setting can typically be adjusted via the LCD interface.

- Utility First (Default): The inverter will prioritize power from the utility grid to supply the loads. Solar power will only be used to power the loads when utility power is unavailable.
- Solar First: Solar energy is the primary power source for the loads. If solar energy is insufficient to power all connected loads, the utility grid will supply power simultaneously. If both solar energy and utility power are unavailable, or if solar energy is insufficient and utility power is not available, the loads will not receive power.
3.3 LCD Settings
The inverter features an LCD display for monitoring system status and configuring various parameters, including the input voltage range for home appliances and personal computers.

Refer to the on-screen menu for navigation and adjustment of settings.
4. Maintenance
Regular maintenance ensures the longevity and reliable performance of your inverter.
- Cleaning: Keep the inverter's exterior clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Ventilation: Ensure that the ventilation openings are clear and unobstructed to prevent overheating.
- Connections: Periodically check all electrical connections (PV input, AC input, AC output, ground) for tightness and signs of corrosion.
- Environmental Conditions: The inverter has an IP21 ingress protection rating, meaning it is protected against solid objects over 12.5mm and vertically falling drops of water. Avoid exposing the inverter to direct water spray or harsh weather conditions.
5. Troubleshooting
This section provides guidance for common issues. For complex problems, contact qualified service personnel.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter does not start with PV power only. | PV voltage is below the minimum required (150Vdc). | Ensure PV voltage is above 150Vdc. Check solar panel connections and sunlight conditions. |
| Inverter shuts down unexpectedly. | Overload, over-temperature, or short circuit detected. | Reduce connected load, check for obstructions to ventilation, inspect wiring for short circuits. Allow inverter to cool down before restarting. |
| Loads not receiving power. | Incorrect startup/shutdown sequence, insufficient solar/utility power, or inverter fault. | Follow correct startup sequence (inverter ON, then loads ON). Check power source availability (solar, utility). Verify output source priority setting. |
| Attempting to connect batteries. | Misunderstanding of inverter capabilities. | This inverter model does not support battery connections. Do not attempt to connect batteries. |
6. Specifications
Detailed technical specifications for the Anern AN-PVI-6000W and AN-PVI-10000W models.

| Parameter | AN-PVI-6000W | AN-PVI-10000W |
|---|---|---|
| General | ||
| Model | AN-PVI-6000W | AN-PVI-10000W |
| Rated Power | 6KVA/6KW | 10KVA/10KW |
| Phase | 1-phase in/1-phase out | |
| PV Input (DC) - Grid-Tie Operation | ||
| Maximum PV Input Power | 4500W * 2 | 4500W * 3 |
| Maximum DC Voltage | 500Vdc | |
| Start-up Voltage / Initial Feeding Voltage | 90Vdc / 120Vdc | |
| MPPT Voltage Range | 60-450Vdc | |
| Number of MPP Trackers / Maximum Input Current | 2 / 18A | 3 / 18A |
| Grid Output (AC) | ||
| Nominal Output Voltage | 220/230/240VAC | |
| Output Voltage Range | 184-264.5VAC or 195.5-253VAC or 184-264.4VAC (Selectable) | |
| Nominal Output Current | 26A | 43A |
| Power Factor | >0.99 | |
| Efficiency | ||
| Maximum Conversion Efficiency (DC/AC) | 97% | |
| AC Input - Off-Grid Operation | ||
| AC Start-up Voltage / Auto Restart Voltage | 120-140VAC / 180VAC | |
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | |
| Frequency Range | 50Hz/60Hz (Auto sensing) | |
| Maximum AC Input Current | 40A | 50A |
| Physical | ||
| Dimension (D x W x H) | 360x278x106 mm | 360x310x107 mm |
| Net Weight | 4.9 kg | 6.5 kg |
| Interface | ||
| Parallel Function | No | |
| Communication Port | RS232 (WIFI), CAN (Parallel) | |
| Environment | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| IP Degree | IP21 | |
| Operating Temperature | -10℃ to 50℃ | |
| Storage Temperature | -15℃ to 60℃ | |


7. Warranty and Support
For warranty information, terms, and conditions, please refer to the documentation provided at the time of purchase or contact your seller directly. For technical support or service inquiries, please contact Anern customer service or your authorized dealer.
8. User Tips
- Verify Specifications: Before purchasing or installing, always confirm the exact model specifications (e.g., 6KW vs. 10KW) and physical dimensions to ensure it meets your requirements.
- No Battery Support: Remember that this inverter series is designed for direct power conversion and does not support battery storage. Do not attempt to integrate batteries into the system.
- Grid-Tie and Off-Grid Functionality: The AN-PVI series supports both grid-tie and off-grid operations. Ensure your setup and configuration match your intended use and local regulations.
- Water Pump Sizing: If using with a water pump, ensure the inverter's power rating is significantly higher (5-7 times) than the pump's power for optimal performance and to prevent overload. This inverter is primarily for domestic small water pumps.