GVDA GD101B

Contents

GVDA GD101B Socket Tester Pro User Manual

Model: GD101B | Brand: GVDA

1. Introduction

The GVDA GD101B Socket Tester Pro is designed for the polarity detection of three-hole power socket wiring and the protection function detection of leakage switches (RCD). It provides a quick and accurate method to detect the wiring condition of a socket, helping to identify issues that could lead to electric shocks, electrical fires, or abnormal equipment operation. This device is widely used in fire protection, safety supervision, home improvement, laboratory, factory, and general home line inspection and maintenance.

2. Safety Information

Warning: Please read this instruction manual carefully before use and strictly adhere to all safety rules, cautions, and warnings listed herein to prevent potential electric shock or personal injury.

  • Before each use, carefully inspect the tester for any damage. If damage is found, discontinue use immediately and send it for repair.
  • To verify the tester's functionality, plug it into a known correctly wired socket and confirm that the test functions operate as expected before proceeding with other tests.
  • When performing switch detection, ensure the wiring is correct for normal operation.
  • When conducting the leakage switch (RCD) test, always turn off all electrical appliances connected to the circuit to prevent any harm from power outages. If testing in public areas, ensure prior approval is obtained.
  • If a socket wiring error is detected, consult a professional electrician to rectify the wiring.

3. Product Overview

The GVDA GD101B Socket Tester Pro is a plug-and-play device featuring line detection and leakage protection. It offers multiple functions including color display, socket polarity detection, leakage tripping detection, and auto power-off for safe and easy use.

GVDA GD101B Socket Tester Pro with features: Plug and play, Line detection, Leakage protection
Figure 1: GVDA GD101B Socket Tester Pro overview.
Icons representing the multi-functions of the socket tester: Plug and play, Socket polarity detection, Leakage tripping detection, Safe measurement, Color display, Auto Power Off.
Figure 2: Key functions of the GD101B Socket Tester Pro.

3.1 Panel Introduction

Familiarize yourself with the components of the socket tester:

Diagram of the GVDA GD101B Socket Tester Pro with numbered parts: 1. Low battery indication, 2. Socket pin indication, 3. Zero-live voltage test value display, 4. Power on/off, 5. Socket wiring status display area, 6. Zero-earth voltage test value display, 7. RCD leakage current, 8. Low battery indication.
Figure 3: Front panel components and indicators.
  1. Low battery indication: Icon illuminates when battery power is low.
  2. Socket pin indication: Visual representation of the socket pins.
  3. Zero-live voltage test value display: Shows the voltage between the live and neutral lines.
  4. Power on/off: Button to turn the device on or off.
  5. Socket wiring status display area: Indicates the detected wiring condition (e.g., correct, missing ground).
  6. Zero-earth voltage test value display: Shows the voltage between the neutral and earth lines.
  7. RCD leakage current: Indicates the RCD test current.

4. Setup

4.1 Battery Installation

The device requires 2 x 1.5V AAA batteries (not included) for operation.

Image showing the GVDA GD101B Socket Tester Pro with its battery compartment open and two AAA batteries next to it, indicating batteries are not included.
Figure 4: Battery compartment and required AAA batteries.
  1. Before using, open the battery cover located on the device.
  2. Install two AAA batteries, ensuring correct polarity.
  3. Close the battery cover securely.

5. Operation

5.1 Power On

Long press the power button (ON/OFF) for 2 seconds to turn the device on.

5.2 Basic Socket Testing

Plug the product into the socket to be tested. The device will automatically display the current socket line status and voltage.

Three-step operation introduction: 1. Install AAA batteries, 2. Long press power button for 2 seconds to power on, 3. Plug into socket to test line status and voltage.
Figure 5: Steps for battery installation, power-on, and basic testing.

5.3 RCD Test (Leakage Tripping Detection)

Warning: Before performing the RCD test, ensure all electrical appliances on the circuit are turned off and permission is obtained to avoid any harm from power outages.

Insert the tester into the three-hole socket. When the display prompts "The wiring is correct", press the RCD button for less than 3 seconds. A normal leakage switch will trip. If no tripping occurs, it indicates that the leakage switch has failed or is missing. In such cases, seek professional electrician maintenance immediately.

Diagram illustrating the RCD test. The tester is plugged into a socket, showing 'The wiring is correct'. A hand presses the RCD button. Examples show 'No trip/Abnormal leakage switch' and 'Trip/Normal leakage switch' with corresponding light status.
Figure 6: RCD Test procedure and outcomes.

5.4 Socket Polarity Detection

The tester automatically detects and displays the zero-live voltage (L-N) and zero-earth voltage (N-E) to indicate socket polarity. A high definition color display ensures clear visibility of these values even in dark environments.

Image showing the socket tester displaying zero-live voltage (N-L) and zero-earth voltage (N-E) readings.
Figure 7: Socket polarity detection displaying voltage values.
Image of the socket tester's color display in a dark environment, showing clear screen values.
Figure 8: High definition color display for clear readings.

6. Test Status Analysis

The socket wiring status display area provides clear indications of various wiring conditions:

Six diagrams showing different wiring status indications on the socket tester: The wire is correct, Missing zero line, Missing ground, Fire ground reverse, Fire zero reverse, Mismatch and lack of land.
Figure 9: Visual indications for various wiring statuses.
  • The wiring is correct: Indicates proper wiring. (Reference values shown on the right are for display only).
  • Missing zero line: The icon in the dotted line will flash an alarm.
  • Missing ground: The icon in the dotted line will flash an alarm.
  • Fire ground reverse: The icon in the dotted line will flash an alarm.
  • Fire zero reverse: The icon in the dotted line will flash an alarm.
  • Mismatch and lack of land: The icon in the dotted line will flash an alarm.

6.1 Special Attention

  • The normal voltage range for the zero-live line (L-N) is typically within ±10% of the local standard voltage. If the reading is significantly too high or too low, it may indicate an excessive circuit load or an issue with the power supply.
  • The normal voltage for the zero-earth wire (N-E) should ideally be less than 2V. A higher reading might suggest current leakage, an imbalance in the three-phase sequence, or signal interference within the circuit.

7. Specifications

ParameterValue
Plug TypeEU plug
Zero-live voltage measure (L-N)30-250V / (50-60HZ)
Zero-earth voltage measure (N-E)0.1-10V / (50-60HZ)
Working environment temperature0°C-40°C
Working environment humidity20%-70%
Storage environment temperature10°C-50°C
Storage environment humidity20%-80%
RCD current>30mA
RCD working voltage220V±20V
Battery2 x 1.5V AAA (not included)
Product weight82g
Package weight110g

8. User Tips

  • Always ensure the tester's display is clear and readable before interpreting results, especially in varying light conditions.
  • For consistent and reliable RCD test results, always disconnect all other loads from the circuit being tested.
  • If you encounter any unexpected readings or persistent errors, refer to the troubleshooting section or consult a qualified electrician.

9. Maintenance

9.1 Battery Replacement

To prevent electric shock or injury from incorrect readings, replace the batteries immediately when the low battery symbol appears on the display. To avoid electric shock or personal injury, always turn off the power and ensure the socket tester is removed from the measurement circuit before opening the battery cover to replace new batteries.

10. Warranty and Support

This product is guaranteed for 18 months from the date of purchase. The warranty does not cover fuses, disposable batteries, accessories (such as packaging boxes), or damage to the instrument due to accidents, neglect, abuse, alterations, pollution, or abnormal operating conditions.

This manual is subject to change without notice. While the contents of this manual are considered correct, if you find any errors or require further assistance, please contact the manufacturer or seller.

The company is not responsible for accidents and hazards caused by user's wrong operation. The functions described in this manual should not be used as a reason to use the product for a special purpose not intended by the manufacturer.

For the complete user manual, please refer to the official PDF document: GVDA GD101B User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.