1. Introduction
This manual provides essential information for the safe and efficient operation of your Feyree EVSE Wallbox EV Charger. Please read this manual thoroughly before installation and use to ensure proper functionality and safety.
The Feyree EVSE Wallbox is a smart, wall-mounted charging station designed for electric vehicles, offering convenient and reliable AC charging. It features a 4.3-inch LCD display, Wi-Fi and Bluetooth connectivity for smart app control, and multiple safety protection functions. The charger is suitable for outdoor use with its IP66 dustproof and waterproof rating.
2. Safety Instructions
Always adhere to these safety guidelines to prevent injury or damage.
- Warning: The charging station must be properly grounded (PE) before use.
- Warning: Do not place flammable, explosive, combustible materials, chemicals, combustible vapors, or other hazardous materials near the charging station.
- Warning: Keep the charging plug head clean and dry. If dirty, wipe it with a clean and dry cloth. Do not touch the charging plug core by hand when it is charged.
- Warning: Do not use the charging station if the charging plug or charging cable is defective, cracked, worn, broken, or if the charging cable is exposed.
- Warning: Do not attempt to disassemble, repair, or modify the charging station. Improper operation may cause damage, water leakage, electrical leakage, short circuit, electric shock, or other risks. Contact qualified personnel for service.
- Warning: Use with caution during thunderstorms.
- Warning: Children should not approach or use the charging station during the charging process to avoid electric shock.
- Warning: Do not drive the car while it is charging. Charging can only begin when the car is stationary. For hybrid cars, turn off the engine before charging.
- Warning: In case of emergency, press the emergency stop button immediately to cut off all input and output power.
- Warning: The use of the charging post is prohibited in the following cases:
- Charging Station shell is broken.
- The charging cable on the charging station is damaged, cracked, frayed, or broken.
- Lightning strikes the charging station.
- Accidents or fires near charging stations.
- Water in the charging station.
- The length of the charging cable is not sufficient, and an extension cable is needed (contact manufacturer for guidance).
3. Product Overview
The Feyree EVSE Wallbox EV Charger is designed for electric vehicle AC charging, featuring a simple design and robust functionality. It supports Type 1 (SAE J1772) charging standards and offers multiple safety features, making it suitable for outdoor installation.
3.1. Key Features
- Safe and CE & FCC Certified: CE certified with TUV certified cables, ensuring efficient and reliable charging. Built-in multiple protections including over current, over voltage, under voltage, ground fault, and over temperature protection.
- Smart and Intelligent EV Charger: Equipped with a 4.3-inch large screen that monitors all charging conditions, including voltage, current, and charging time.
- Calendar Settings: Time and date can be synchronized via Wi-Fi or set manually.
- Money Saving Mode: Supports scheduled charging during off-peak hours.
- Charging Log Intelligent Management: Stores up to 500 charging log details, including duration, power consumption, and date.
- Charging Fault Log Records: Records up to 100 charging faults with time and error codes for quick troubleshooting.
- Faster Charging Speed: Available in 7.6kW, 9.6kW, and 12kW models to meet various car requirements.
- Convenient Wi-Fi Connectivity: Control and monitor charging remotely using the free Tuya Smart app, including setting current and scheduling.
- Compatible with All EV: Comes with a SAE J1772 (Type 1) connector, suitable for any EV with a Type 1 AC socket.
- High-Quality Material: Features 99.95% pure copper cable, durable and flexible TPU insulation, 5µ silver-plated charging pins for better conductivity, and 100% NO TIN PCB in line with international environmental standards.
3.2. Product Diagram and Dimensions
The charging station features a clear display, touch buttons for control, an RFID card induction area, and an emergency stop switch.


Dimensions:
- Length: 42 cm
- Width: 33 cm
- Height: 14 cm
4. Specifications
4.1. General Specifications
| Attribute | Value |
|---|---|
| Brand Name | feyree |
| Charger Type | Charging Station |
| Type | Type1 (SAE J1772) |
| Voltage | 85V-264V |
| Current (Adjustable) | 8A-10A-13A-16A-20A-25A-32A-40A-50A |
| Power | 7.6KW/9.6KW/12KW |
| Number of Phases | Single Phase |
| Input Frequency | 50Hz-60Hz |
| Cable Length | 5m |
| IP Rating | IP66 |
| Operating Temperature | -30 to 55°C |
| Material | Copper alloy, silver plating |
| Weight | 5.3kg |
| Screen Size | 4.3inch |
| Wireless Support | Wifi |
| RCD | TypeB AC30mA+ DC 6 mA |
4.2. Detailed Parameters (Type 1 SAE J1772)
| Parameter | 7.6kW | 9.6kW | 12kW |
|---|---|---|---|
| Load balancing | / | / | ● |
| APP | ● | ● | ● |
| RFID Card | ● | ● | ● |
| Type B RCD | ● | ● | ● |
| Leakage Protection Value | TypeB: AC 30mA+DC 6mA | ||
| Power supply system | Level 1 and Level 2 | ||
| Rated voltage | 85V-264V | ||
| Rated current | 8-10-13-16-20-25-32A | 8-10-13-16-20-25-32-40A | 8-10-13-16-20-25-32-40-50A |
| Input Frequency | 50Hz/60Hz | ||
| Charger Plug IP | IP66 | ||
| Charger Box IP | IP66 | ||
| Working temperature | -35°C ~ +55°C | ||
| Storage temperature | -40°C ~ +80°C | ||
| Standby power | <3W | ||
| Working humidity | 5%~95% non-condensation | ||
| Cable Specification | 3G 6mm²+2*0.5mm² | 3G 8mm²+2*0.5mm² | 3G 10mm²+2*0.5mm² |
4.3. Control Box Functions & Product Performance
Control Box Functions:
- Leakage protection (restart recovery)
- Overvoltage and undervoltage protection (self-test recovery)
- Lightning protection
- Overcurrent protection
- Overheat protection
- Grounding protection
- RFID card function (can be set according to user needs)
- Appointment Time
- Wi-Fi
Product Performance:
- Charging plug according to SAE J1772 standard
- Charging control box in accordance with IEC61851 control principle
- Insulation resistance: >1000Ω
- Terminal temperature rise: <50K
- Mechanical life: Charging Plug plugging and unplugging times (Non-operating state) >10000 times
- External impact: Charging Station Plug can withstand the 1-meter drop and 2 tons of vehicle crushing
- Altitude: ≤2000m
- With emergency stop function
5. Installation
5.1. Pre-use Preparation
- Ensure there are no open flames around the equipment and that the surrounding space is not blocked.
- Ensure the equipment casing and charging cable are not damaged.
- Ensure proper maintenance of equipment.
- Make sure the emergency stop button is popped up. If it has been pressed, rotate the button clockwise to turn it back.
5.2. Mounting Instructions
- Step 1: Mount the metal bracket. According to the position of the holes on the metal back mounting bracket, use an electric drill to create holes in the wall. Refer to the height diagram (1280mm from ground to top of charger, 800mm from ground to bottom of charging plug holder). Insert expansion tubes into the holes, then use long screws to fix the metal mounting bracket to the wall.
- Step 2: Secure the charger. After fixing the metal bracket to the wall, hang the charger on the bracket. Use screws to fix the metal bracket underneath the charger to the wall.
- Step 3: Install the charging plug holder. Install the charging plug holder in the position shown in the pictures above.
- Step 4: Connect power. Connect the power supply and ensure the charger works properly.

5.3. Wiring Diagrams
Single-phase Wiring

Three-phase Wiring (for DLB function model)

6. Operating Instructions
6.1. Charging Steps
- Standby Status: When the charging station is in standby mode, the interface shows that the device is ready for charging. The indicator light on the wallbox is green and always on.
- Waiting for Card Swipe Status: After parking your car, take the charging plug from the holder, set the charging current (if needed), then insert the charging plug into the EV connector. Ensure the plug is securely inserted. The station will then enter identity verification status.
- Start-up Device: Use an RFID card to authorize the charging station.
- Start Charging: The device will begin charging, and the interface will display charging status and parameters. The indicator light (for Wi-Fi function only) will be green and breathing.
- Stop Charging: Charging will automatically stop when the vehicle is fully charged. In an emergency, press the Emergency Stop button. An RFID card can also be used to stop charging.


6.2. Key Operation Instructions (Touch Buttons)
The charger features touch buttons for various settings:

- How to set the charging current: When the charging plug is not inserted, press button 'A' on the panel to adjust the charging current. After swiping the RFID card to start charging, the device will output the corresponding current. The current setting range depends on the max charging power of the station (e.g., 7.6kW/22kW versions can set 8-32A, 11kW version can set 8-16A).
- How to set time delay charging: When the charging plug is not inserted, touch the 'D' button to set the delayed charging time (0 to 15 hours, each touch increases by one hour). After swiping the card, the charger will start charging after the set delay.
- How to set the timing charging: Touch the 'T' button to modify the timing charging (0 to 15 hours, each touch increases by one hour). After swiping the card, the charger will charge for the set duration and then stop.
- How to access the menu page: Press the settings icon (gear symbol) for 5 seconds to enter the settings menu. If using an RFID function version, you may need to swipe the RFID card after pressing the button.
- Menu page basic key operation: Use the panel icons (upward, downward, enter, back) to navigate and adjust menu parameters. Note: When the charging plug is inserted, it is not possible to enter the charging plan and load balance setting function. The plug must be removed to operate these settings.


6.3. Menu Structure
The menu provides access to various settings and information:
- Charge Plan: Configure one-off or default charging plans.
- One-off Plan: Set current, delay start time, and charge time.
- Default Plan: Set prohibited charging start and end times.
- RFID Manage: Manage RFID cards (Charge Verify, ID List for adding/deleting cards).
- Charge Log: View charging history for the past 12 months.
- Setting: Access Basis Settings, Net Settings, and Time Settings.
- About Device: View device information and key data.
6.4. Dynamic Load Balancing (DLB) (for DLB function models)
DLB charging stations intelligently adjust charging power based on the household's total circuit load, prioritizing the charging station's output relative to other appliances. This ensures electrical safety by preventing overload.
Working Principle:
- Total Current: Maximum current capacity per phase (e.g., 80A) for the home circuit, adjustable from 8A to 99A. Exceeding this value will trip the circuit breaker.
- CT Sensor: A monitoring device installed on the main household circuit to collect real-time total current data from all electrical devices, including the charger.
- Charging Current: The real-time charging current when the charger is operating.
- Home Appliance: Total load of home appliances in the maximum load circuit, excluding the charging station.
- Standby Current: Calculated as “Total Current” - “CT Sensor”.
DLB Scenarios (Single Phase Example):
- Scenario 1: DLB Active (Charging Current + Standby Current ≥ 8A, but less than set current). The charger uses the calculated standby current.
- Scenario 2: DLB Inactive (Charging Current + Standby Current ≥ set current). Full power charging.
- Scenario 3: DLB Active (Charging Current + Standby Current < 8A). Charger stops charging.



6.5. Control Box LCD Display
The LCD display provides real-time information and status updates for both single-phase and three-phase configurations.
Single-phase Interface

Three-phase Interface

6.6. App Control
The Feyree EVSE Wallbox can be controlled and monitored via a smart app. Download either the