1. Product Overview
The Beok CCT-28-X Wireless Hub Controller is designed for water underfloor heating systems. It acts as a central control unit, managing zone valves or boiler thermostats, and can also control the boiler and circulating pump. According to user's set temperature, hub controller can control to open or close the boiler, circulating pump, and electric actuators, optimizing comfort and energy consumption.
Product overview and unboxing of the Beok CCT-28-X Wireless Hub Controller.

System diagram showing the Beok CCT-28-X Wireless Hub Controller connected to various components, including up to 8 thermostats, 64 normally closed actuators, a boiler, and a pump.
2. Product Advantages
- Easy to Connect with Power: Users only need to reserve main supply at the manifold location before installation. A simple three-wire cable connects to thermostats, eliminating the need for professional wiring.
- Easy to Connect Wires: Wires are connected according to color codes, simplifying the process.
- Easy Maintenance: All wiring is clear and neat, facilitating easy maintenance after installation.
- Boiler and Pump Protection: The hub controller features a time delay function, ensuring the boiler and pump only activate when the water valve is fully open. This protects the components and optimizes energy usage.
- Extended Boiler and Pump Life: The hub controller activates the boiler and pump only at appropriate temperatures, reducing their running time and extending their operational life.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Power Supply | 220VAC |
| Current Loading | Max 20mA |
| Frequency | 433MHz |
| Wireless Signal Distance | 30m (indoor), 200m (outdoor) |
| Ambient Temperature | 0-85°C |
| Pump Output Delay | 5min |
| Max. Power of Pump | 1000W |
| Control Objects | Boiler (Dry Contact: gas, electric, pellet boilers), Pump, Normally Closed Actuators, Wireless Thermostats |
| Max. Thermostats Controlled | 8 pcs |
| Max. Actuators per Terminal | 8 pcs |
| APP Controls | Tuya Smart / Smart Life |
| Voice Controls | Alexa / Google / Yandex Alice |
| Thermostat Power | AA Battery-powered (BOT-R6X/R7X-WIFI), USB Powered (BOT-R7X-WIFI) |
4. Indicator Illustration
The hub controller features several LED indicators:
- LED1-LED8 (Thermostat Indicator Light):
- When the thermostat starts heating, the LED light will light up.
- When the thermostat stops heating, the LED light will go off.
- When the thermostat is pairing, the LED light will flash.
- LED9 (Pump Indicator Light):
- When the circulation pump is working, the LED light will light up.
- When the circulation pump stops working, the LED light will go off.
- LED10 (Boiler Heating Indicator Light):
- When the boiler starts heating, the LED light will light up.
- When the boiler stops heating, the LED light will go off.
- LED11 (Power Indicator Light): The light is always on when the hub controller is powered on.

Indicator lights on the Beok CCT-28-X Wireless Hub Controller.
5. Installation and Wiring
The CCT-28-X Wireless Hub Controller is designed for easy installation. Ensure all power is disconnected before beginning any wiring procedures.
5.1. Wiring Diagram

Internal components and connection points of the hub controller.

Comprehensive wiring diagram for the CCT-28-X hub controller.
5.2. Connection Details
- Normally Closed Actuators: Connect to Zone1 L/N (Zone1-Zone8 are same). Up to 8 normally closed actuators can be connected to each zone.
- Pump: Connect pump L/N.
- Boiler: Connect to COM/NO or COM/NC terminals.
- Power: 110-220V INPUT L/N.
5.3. Important Installation Notes
- Before installing, disassembling, cleaning, or maintaining the controller, the main power supply must be cut off, the fuse must be pulled out, or the circuit breaker must be turned off.
- Before installing the controller, you must read and strictly follow these instructions.
- The controller should be installed by a professional engineering company with appropriate safety knowledge.
- All wire connections should comply with local and national standards.
6. Pairing Instructions
Follow these steps to pair your thermostats with the CCT-28-X Wireless Hub Controller:
6.1. General Pairing Procedure
- Initiate Pairing on Hub: Long press the "RF Pairing Key" on the hub controller for 3 seconds until LED8 starts flashing. This indicates the hub is ready for pairing.
- Pair R6 Thermostat: With the R6 thermostat powered on, long press the ▲ button until the pairing icon appears (displayed for less than 1 second). Upon successful pairing, LED8 on the hub will stop flashing, and LED7 will start flashing.
- Pair R7 Thermostat: With the R7 thermostat turned off, long press the ✔ button until the pairing icon appears (displayed for less than 1 second). Upon successful pairing, LED7 on the hub will stop flashing, and LED6 will start flashing.
- Continue Pairing (Optional): If you don't need to perform the next pairing, wait 15 seconds until the LED light stops flashing. After completing the pairing of a thermostat, turn it off and then on again for the control to take effect.
Video demonstrating the pairing process for Beok thermostats with the CCT-28-X hub.
6.2. Switching Paired Terminals
If you need to switch the terminals for pairing, press the "pairing key" on the hub. The LED lights will jump from LED8 to LED1 in sequence. When the LED light corresponding to the desired terminal starts flashing, follow the general pairing procedure (Step 2) to complete the pairing.
6.3. One Thermostat Controls Multiple Terminals
To use one thermostat to pair all terminals, pair LED8 first. Once LED8 is paired, LED7 will start flashing. Use the same thermostat to repeat the pairing steps for LED7, and continue this process until LED1 is paired.
6.4. Cancel Pairing
To cancel pairing for a thermostat:
- Long press the "pairing button" on the hub for 3 seconds until LED8 starts flashing.
- Short click the "pairing button" to switch the flashing LED light to the terminal you wish to unpair.
- Long press the "pairing button" again for 3 seconds until the LED light for that terminal stops flashing. This indicates the pairing has been canceled.
7. Operating Instructions
7.1. Thermostat Operation (R7X Model)

Adjusting the temperature on the R7X thermostat.
- Temperature Adjustment: Press the ✔ key on the screen. The set temperature will start blinking. Turn the outer ring to adjust the temperature.
7.2. Thermostat Display and Backlight (R6X Model)

R6X thermostat display and backlight behavior.
- Backlight On: The backlight illuminates when any button is pressed.
- Backlight Off: The backlight turns off automatically after 15 seconds of inactivity.
- Power Off: The display will be blank when the thermostat is powered off.
7.3. Smart Control via App and Voice
The Beok system supports smart control through the Tuya Smart/Smart Life app and voice assistants.

Sharing device control via the Tuya app.
- Tuya Smart/Smart Life App: Control your thermostat remotely, set schedules, and monitor your heating system. You can also share control permissions with family and friends via the app.
- Voice Control: Compatible with Alexa, Google Assistant, and Yandex Alice for convenient voice commands.
8. Power Supply and Mounting Options
8.1. Thermostat Power Supply

Thermostat power supply options: AAA batteries or Type-C USB.
- Battery-powered: The BOT-R6X and BOT-R7X thermostats can be powered by 3xAAA batteries (not included).
- USB Powered: The BOT-R7X thermostat can also be powered via a Type-C USB cable. It features a dual-port design, allowing connection from either the side or back.
8.2. Thermostat Mounting Options

Thermostat mounting options: Wall or Tabletop.
- Wall Mount: Securely mounts to walls using screws only, no junction box required.
- Table Stand: Features a detachable magnetic base for tool-free placement on a table or desk.
9. Maintenance and Safety Precautions
- Before any maintenance, cleaning, or disassembly of the controller, ensure the main power supply is completely cut off. This includes pulling out the fuse or turning off the circuit breaker.
- Always read and strictly follow the instructions provided in this manual before installing or operating the controller.
- Installation of the controller should be performed by a professional engineering company with appropriate safety knowledge.
- All wire connections must comply with local and national electrical standards and regulations.
10. Troubleshooting and Power Outage Recovery
10.1. Power Outage Recovery
In the event of a power outage, the system is designed to recover automatically. The thermostat sends a signal to the controller every 30 minutes. The system will resume normal operation within 30 minutes after power is restored.
10.2. Common Issues and Solutions
- Thermostat not responding: Check battery levels (if applicable) or USB power connection. Ensure the thermostat is within wireless range of the hub (30m indoor, 200m outdoor). Re-pair the thermostat if necessary.
- Heating system not activating: Verify that the hub is powered on (LED11 is lit). Check the pairing status of the thermostats (LED1-LED8). Ensure wiring connections for boiler, pump, and actuators are secure and correct.
- App connectivity issues: Ensure your phone's Bluetooth and 2.4G WiFi are enabled. Verify correct WiFi name and password in the Tuya app. Restart the app and try adding the device again.
11. Warranty and Support
Beok products are designed for reliability and performance. For detailed warranty information, technical support, or service inquiries, please refer to the official Beok website or contact your local distributor.
A PDF version of the user manual is available for download: User Manual (PDF).