1. Introduction
The RIDEN RD6030 is an assembled digital control stabilized AC/DC adjustable voltage regulated lab bench power supply, offering high power output up to 1440W (230V AC input) or 1140W (110V AC input). This device is designed for precise voltage and current control in laboratory and testing environments. It features a 2.4-inch color HD display, multiple protection mechanisms, and supports both PC software and mobile app control (with optional WiFi module).

Figure 1: RIDEN RD6030 Digital Control Power Supply
2. Important Safety Warnings
- High-Frequency Noise: The switching power supply may produce a high-frequency noise when unloaded. This is a normal phenomenon for industrial-grade products due to PWM control chip operation at reduced frequencies. The noise level can vary slightly between units due to manufacturing tolerances.
- Fan Noise: The cooling fan may operate loudly, especially when the ambient temperature is high or under load. This is normal for proper heat dissipation.
- Power Off When Not In Use: It is strongly recommended to turn off the AC switch when the product is not in use to prevent potential issues and reduce power consumption.
- Inductive Loads: When connecting inductive loads (e.g., motors), ensure the maximum working voltage and current do not exceed 1/3 of the full range to prevent damage.
- Do Not Remove PSU Case: Do not remove the shell of the internal power supply unit (PSU) for heat dissipation. Doing so can alter the heat dissipation system, leading to insufficient cooling, overheating, and damage, and will void the after-sales service.
- Panel Traces: Slight traces at the button holes on the panel are normal due to the injection molding process and do not indicate damage.
- Battery Charging: The battery charging function should only be used by professionals. Improper use can lead to fire and explosion hazards. Ensure firmware is updated for optimal battery charging experience.
3. Package Contents
The RD6030 Assembled Set comes with the following items:

Figure 2: Included Accessories
- 1 x RD Power Supply
- 1 x X36A Output Cable
- 1 x Input AC Power Cord (AC cord type depends on region: US/EU/UK/AU Plug)
- 1 x Micro Communication Cable (inside X36A bag)
- 1 x External Temperature Sensor
- 1 x Backup Fuse
- 1 x Packing Box
4. Specifications
Below are the detailed technical specifications for the RIDEN RD6030 power supply:

Figure 3: Key Product Information
| Feature | Specification |
|---|---|
| Model | RD6030 Assembled Set |
| Screen | 2.4 inch color HD display |
| Input Voltage Range | 100-120V AC / 200-240V AC |
| Output Voltage Range | 0-60.00V |
| Output Current Range | 0-30.00A |
| Output Power Range | 0-1440W (AC220V) / 0-1140W (AC110V) |
| Product Dimension | 173mm * 92mm * 336mm |
| Weight (with package) | About 3.9kg |
| Output Voltage Setting Resolution | 0.01V |
| Output Current Setting Resolution | 0.01A |
| Battery Voltage Measurement Resolution | 0.01V |
| Output Voltage Accuracy | ±(0.3%+3 digits) |
| Output Current Accuracy | ±(0.5%+5 digits) |
| Battery Voltage Measurement Accuracy | ±(0.5%+3 digits) |
| Automatic Cut-off Current (Charging) | User-settable (higher than 100mA) |
| Output Ripple Typical | 50mV@15A, 90mV@30A VPP |
| Working Temperature Range | -10℃~40℃ |
| External Sensor Temperature Range | -10℃~100℃ / 0℉~200℉ |
| External Sensor Temperature Accuracy | ±3℃ / ±6℉ |
| Constant Voltage Mode Response Time | 2ms (0.1A-5A Load) |
| Constant Voltage Mode Load Regulation | ±(0.1%+2 digits) |
| Constant Current Mode Load Regulation | ±(0.1%+3 digits) |
| Capacity Measurement Range | 0-9999.99Ah |
| Energy Measurement Range | 0-9999.99Wh |
| Capacity and Energy Statistical Error | ±2% |
| Over Temperature Protection | System temperature > 80℃ |
| Screen Brightness Setting | 0-5 (6 levels in total) |
| Cooling Fan Start Condition | Output current > 8A or System temperature > 45℃ |
| Cooling Fan Shut Down Condition | Output current < 7.9A and System temperature < 40℃ |
| USB Communication | Yes |
| WiFi Communication | No (Optional WiFi board required for APP connection) |
*Ripple measurement method: Noise and ripple are measured at X1 range, AC coupling, 20MHz of bandwidth on your oscilloscope with a 0.1uF parallel capacitor at the output terminals.

Figure 4: High Current Performance Overview

Figure 5: Comparison of RD Series Models
5. Setup
5.1 Initial Connection
The RD6030 is provided as an assembled set, meaning it is ready for direct AC power connection. Simply connect the appropriate AC power cord (US/EU/UK/AU plug, depending on your region) to the unit and a suitable power outlet.

Figure 6: Assembled RD6030 Ready for Operation
5.2 Optional WiFi Module and Battery
This assembled set does not include a WiFi card for APP connection or a CR1220 battery for date/time display. If you wish to use the WiFi function, you must order the WiFi card separately. Note that if you install the WiFi card, you cannot easily remove it to install the CR1220 battery later. The WiFi card link is: https://www.aliexpress.com/item/4000478822325.html.
6. Operation
6.1 Basic Controls and Interface
The RD6030 features a user-friendly interface with silicone buttons for efficient and fast operation. The 2.4-inch color HD display provides clear readings of voltage, current, power, and other parameters.

Figure 7: Silicone Button Control for Easy Operation
6.2 Display Styles
The system supports multiple display styles: Classic, Detailed, and Curve. You can switch between these styles to suit your preference by navigating through the display settings. The device also supports a Nixie Tube display option.

Figure 8: Customizable Display Styles

Figure 9: New Settings Interface with Language and Custom Color Options
6.3 Data Storage and Recall
The RD6030 allows for convenient storage and recall of setting parameters. Use the dedicated functions to save frequently used configurations and quickly load them when needed.

Figure 10: Data Storage and Call Out Functionality
6.4 Battery Charging Function
The power supply includes green charging terminals specifically designed for battery charging. It can be used to charge multiple types of batteries. Ensure you have the latest firmware version for the best battery charging experience. Non-professionals should not use this function due to potential hazards.

Figure 11: Battery Charging Feature
6.5 PC Software Control
The power supply can be monitored and controlled via PC software, offering comprehensive functions and a friendly interface. The PC software supports Windows 7 and above. Connect the device to your PC using the Micro Communication Cable.
Video 1: Product Overview and PC Software Demonstration

Figure 12: PC Software Control Interface

Figure 13: Detailed PC Software Interface
6.6 Mobile App Control (Optional)
For mobile app control (Android and iOS), an optional WiFi board is required. The app allows for easy viewing and setting of parameters. Note that the Wi-Fi communication only supports 2.4G signal; 5G signal is unsupported. Ensure client isolation/AP isolation and WMM functions are disabled on your router, and location/storage services are enabled for the app during installation.

Figure 14: Mobile App Control for Android and iOS
6.7 Multiple Protection Features
The RD6030 is equipped with multiple protection features to safeguard your device and connected equipment:
- OVP (Over Voltage Protection): The output over-voltage value can be set. If the output voltage exceeds this value, the power supply will automatically stop output.
- OCP (Over Current Protection): The output over-current value can be set. If the output current exceeds this value, the power supply will automatically stop output.
- OTP (Over Temperature Protection): If the system temperature exceeds 80℃, the power supply will automatically shut down.

Figure 15: OVP, OCP, OTP Status Indicators
7. Maintenance
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Ensure proper ventilation around the unit to prevent overheating.
- Store the power supply in a dry environment, away from direct sunlight and extreme temperatures.
- Regularly check all cable connections for secure fit.
8. Troubleshooting
8.1 Common Issues and Solutions
- Q: The input AC to DC switch power supply has high frequency noise. Is this normal?
- A: Yes, this is normal. The input AC to DC switch power supply is an industrial-grade product. Due to its large output power range, the PWM control chip may skip some control cycles when unloaded to reduce power consumption. This can cause the working frequency to drop below 20KHz, producing an audible high-frequency noise. The noise level can vary slightly between units due to transformer production processes. This does not affect working performance. It is recommended to turn off the AC switch when not in use.
- Q: The cooling fan is loud.
- A: The fan may run loudly when the ambient temperature is high or under load to ensure proper cooling. This is normal operation. The fan starts when output current > 8A or system temperature > 45℃, and shuts down when output current < 7.9A and system temperature < 40℃.
- Q: Can I use it to power an inductive load?
- A: If connecting an inductive load (such as a motor), the maximum working voltage and current should not exceed 1/3 of the full range to prevent damage.
- Q: There is a fuse in the box. Should I install it?
- A: This is a BACKUP fuse. If the original fuse is burned due to incorrect operation, you can insert this backup fuse into the socket next to the burned one for temporary use. Note that the backup fuse only supports up to 10A. For full output, it is best to remove the damaged fuse and solder a new, appropriate fuse in the same position.
- Q: Can I remove the case of the PSU for better heat dissipation?
- A: No, do not remove the shell of the internal power supply unit (PSU). Removing the shell will alter the heat dissipation system, leading to insufficient cooling, overheating, and potential damage to components. This will void the after-sales service.
- Q: I see some traces on the panel. Is the product damaged?
- A: Slight traces at the button holes on the shell are a normal result of the injection molding process and are typically not noticeable during normal use. This is not considered damage.
8.2 Software/App Related Issues (for models with optional WiFi board)
- Q: The mobile APP crashes on my phone.
- A: App compatibility issues can occur. Ensure your phone runs Android 8.0 or above. It is recommended to download and test the app before purchasing the WiFi board. If the app works fine but crashes, check your phone's operating system and app permissions.
- Q: Why can't I connect the RD6030W to my phone APP via WiFi?
- A: Ensure the WiFi board is properly inserted. Verify that your WiFi network is 2.4GHz (5G is not supported). Disable client isolation/AP isolation and WMM functions on your router. Also, ensure location and storage services are enabled for the app during installation. If problems persist, contact support.
- Q: Why can't I connect the RD6030W to PC via WiFi while I can connect to the Phone?
- A: WiFi connection to PC is a test function and may have poor compatibility with some computers. If you cannot connect via WiFi, please use the USB micro cable for PC control. This function is not guaranteed and technical support for it may be limited.
9. User Tips
- Before purchasing the optional WiFi board, always download and test the PC software and mobile app to ensure compatibility with your operating system and devices.
- When using the battery charging function, ensure you are familiar with safe battery handling practices and consider updating the firmware for improved performance.
- For optimal performance and longevity, always operate the power supply within its specified voltage and current limits, especially with inductive loads.
10. Further Resources
For more detailed instructions and test videos, please refer to the following links:
- RD6030 Set Operation Instruction, PC Software Instruction and Download Link: https://drive.google.com/drive/folders/1_pv3ctOA_koShQ6Qiu1CZVCluHVD47TL?usp=share_link
- RD6030 Actual Test: Output Voltage and Current Accuracy and Load Regulation: https://youtu.be/uz8hn6mEjd4
- RD6030 Actual Test: Output Curve No Overshoot When Power On, Output, Cut Off Input: https://youtu.be/PhinGxqGegA
- Input Voltage Protection: https://youtu.be/3bC2DmaMPh4
- Battery Charging Function Introduction: https://youtu.be/irTbqfqtgU0
- Output Voltage and Output Current Setting: https://youtu.be/S6Kan66dNsk
- Data Group Quick Storage and Call out: https://youtu.be/eo5saPjOGpo
- Keypad Lock and Unlock: https://youtu.be/zxpmasJyQ6Y
- System Setting: https://youtu.be/Q9d3rIgIrOc
- Main Page Style Setting: https://youtu.be/f51VDiY2VHE
- Storage Data Setting: https://youtu.be/i1kTeurS13I
- System Information: https://youtu.be/Um4NQObeeJE
- iOS APP Download, Installation and Connection: https://youtu.be/nH2HYwop0TE
- iOS APP Operation: https://youtu.be/lXSw1CM9IY8
- Android APP Download, Installation and Connection: https://youtu.be/QwyBEUCnp9c
- Android APP Operation: https://youtu.be/hqrF4keTfbE
- PC Software Download and Basic Operation: https://youtu.be/mjt1RMaah1Y
- Firmware Upgrade: https://youtu.be/NOoLfDw0DiY
- Calibration: https://youtu.be/c9sn1wY2mjE
- Logo Update: https://youtu.be/vuVhBsohWts
- RD6006 WiFi Connection Problem and Solution: https://www.youtube.com/watch?v=7sTtc1kweJM
- Actual Test Video: https://www.youtube.com/watch?v=W8CDqu0i-1o&t=28s
11. Warranty and Support
For any technical assistance, inquiries, or support, please contact RIDEN Official Store using the following channels:

Figure 16: Contact Information
- Email: 1749808860@qq.com
- WhatsApp: +8615868147353
- QQ Group: 550112838
- WeChat: 15868147353
Please refer to the official product page or contact support for detailed warranty terms and conditions.