ZEEWEII DSO3D12

Contents

ZEEWEII DSO3D12 User Manual

3-in-1 Digital Oscilloscope, Multimeter, and Signal Generator

Model: DSO3D12

1. Introduction

The ZEEWEII DSO3D12 is a compact and powerful 3-in-1 device, integrating a digital oscilloscope, a high-precision multimeter, and a signal generator. Designed for a wide range of applications from basic R&D and education to car repair and electronics enthusiasts, it offers a 120MHz bandwidth, dual-channel operation, and a clear 3.2-inch HD IPS display. This manual provides detailed instructions for setting up, operating, and maintaining your device.

ZEEWEII DSO3D12 3-in-1 device showing oscilloscope display
Figure 1: ZEEWEII DSO3D12 Smart Oscilloscope (3-in-1)

2. What's in the Box

Please check the contents of your package against the list below. If any items are missing or damaged, contact your vendor immediately.

Package list for ZEEWEII DSO3D12, showing device, probes, and cables
Figure 2: Included accessories and device dimensions.
  • ZEEWEII DSO3D12 Main Unit
  • Oscilloscope Probes (x2)
  • Multimeter Test Leads (x1 pair)
  • USB Type-C Charging Cable
  • Mini Screwdriver for probe adjustment
  • Color Rings for probe identification
  • User Manual (this document)

Device Dimensions: 145mm (Length) x 86mm (Height) x 32mm (Width)

3. Setup and Initial Use

  1. Charging the Device: Connect the provided USB Type-C cable to the device's charging port and a 5V power adapter. The device has a built-in battery with approximately 6 hours of battery life.
  2. Power On/Off: Press and hold the power button (usually located on the side or top) to turn the device on or off.
  3. Connecting Probes:
    • Oscilloscope Probes: Connect the BNC connectors of the oscilloscope probes to the CH1 and CH2 inputs on the top of the device. Ensure a secure connection.
    • Multimeter Test Leads: Connect the red test lead to the 'VΩ' or '10A' terminal and the black test lead to the 'COM' terminal for multimeter functions.
  4. Language Selection: The device supports Chinese and English. Navigate to the settings menu to select your preferred language.

4. Operating Instructions

The DSO3D12 features a user-friendly interface with dedicated buttons for various functions. The 3.2-inch HD IPS display provides clear visuals with a full viewing angle.

3.2-inch HD IPS display of the oscilloscope
Figure 3: High-definition 3.2-inch IPS display.

4.1. Oscilloscope Mode

To enter Oscilloscope mode, select 'OSCOPE' from the main menu. The device supports dual-channel operation, allowing simultaneous measurement and display of two signal waveforms.

Oscilloscope display showing dual channel waveforms and multimeter in small window
Figure 4: Dual-channel oscilloscope display with integrated multimeter view.
  • One-Key Auto: Press the 'Auto' button for automatic waveform detection and display. This feature simplifies setup for quick measurements.
  • Dual Channel (CH1/CH2): Use the 'CH1' and 'CH2' buttons to switch between channels or enable dual-channel display. Channel 2 waveforms can be set to green, cyan, or purple for differentiation.
  • Trigger Settings: Access trigger settings via the 'TrigMode' button. Options include Auto, Normal, and Single trigger types. Trigger edge can be set to Rise or Fall, and the trigger level can be Manual or Auto. Source can be CH1 or CH2.
  • Oscilloscope display showing trigger settings menu
    Figure 5: Trigger settings for precise waveform capture.
  • Cursor Measurement: Use the 'CurX' and 'CurY' buttons to activate X and Y cursors. X cursors measure time intervals (e.g., between pulses), while Y cursors measure voltage differences at two points.
  • Oscilloscope display showing X and Y cursor measurements
    Figure 6: Cursor measurement in action.
  • FFT Spectrum: The Fast Fourier Transform (FFT) function converts waveforms from the time domain to the frequency domain, allowing analysis of frequency components. Supports linear and logarithmic display. Note: FFT does not support frequency measurement.
  • Oscilloscope display showing FFT spectrum analysis
    Figure 7: FFT Spectrum display.
  • XY Mode: This mode combines the waveforms of two channels to form an image, useful for observing Lissajous figures and phase relationships.
  • Oscilloscope display showing various Lissajous figures in XY mode
    Figure 8: Examples of Lissajous figures in XY Mode.
  • Waveform Save/View: Press the 'Save' button to capture the current screen waveform. You can browse saved waveforms as thumbnails and delete unwanted ones.
  • Oscilloscope display showing saved waveform thumbnails
    Figure 9: Waveform Save/View interface.
  • Reference Waveform: The device supports latching reference waveforms, allowing you to statically display a waveform for comparison while dynamic waveforms continue to refresh.

4.2. Multimeter Mode

Select 'DMM' from the main menu to access the digital multimeter functions. The DSO3D12 features a high-precision true RMS multimeter with isolation from the oscilloscope circuit, allowing simultaneous use.

Multimeter display showing resistance measurement
Figure 10: High-precision Multimeter in operation.
  • Measurements: The multimeter can measure DC/AC Voltage, DC/AC Current, Resistance, Capacitance, Diode, and Continuity.
  • Simultaneous Use: When measuring low voltage or resistance, the oscilloscope and multimeter can be used simultaneously, with the multimeter display appearing in a small window in the upper right corner of the screen.
  • Safety: The device incorporates a safe design with peak 400V anti-burn protection, utilizing an isolation transformer and optocoupler chip to isolate the multimeter from the oscilloscope.
  • Diagram illustrating isolation between oscilloscope and multimeter circuits
    Figure 11: Safe design with isolation between oscilloscope and multimeter.

4.3. Signal Generator Mode

Select 'GEN' from the main menu to activate the built-in waveform signal generator. This function allows you to output various test signals.

Signal generator display showing sine wave output settings
Figure 12: Signal generator interface.
  • Waveform Types: Output sine wave, square wave, and triangle wave.
  • Voltage Amplitude: Fixed at 2.5V.
  • Frequency: Adjustable from 1Hz to 2MHz.
  • Square Wave Duty Cycle: Adjustable from 1% to 99%.

5. Features Overview

The ZEEWEII DSO3D12 is packed with features to enhance your testing and measurement experience:

  • High Bandwidth & Sampling Rate: 120MHz bandwidth and 500M equivalent sampling rate (250MS/s real-time sampling rate).
  • Fully Automatic Operation: One-key automatic and fully automatic modes for quick and easy waveform adjustment, ideal for beginners.
  • Device displaying a waveform with 'Fully auto', 'Smart', 'Easy to use' labels
    Figure 13: Fully automatic operation for ease of use.
  • Rich Measurement Items: Supports 14 types of automatic measurement items for comprehensive analysis.
  • Multiple screenshots showing various display modes and measurement items
    Figure 14: Various display modes and 14 types of measurement items.
  • Multi-Field Application: Suitable for basic R&D, education, car repair, power electronics, audio, radio amateur, circuit failure diagnosis, bus waveform analysis, and crystal waveform analysis.
  • List of multi-field applications for the device
    Figure 15: Multi-field use cases.

6. Specifications

Below are the detailed technical specifications for the ZEEWEII DSO3D12.

Table of oscilloscope and multimeter parameters
Figure 16: Detailed Oscilloscope and Multimeter Parameters.

6.1. General Parameters

Feature Specification
ModelDSO3D12
Screen Size3.2 inch
LanguageChinese / English
BracketCollapsible stand
Key TypeSoft silicone keys
ChargingTYPE-C 5V
Battery TimeAbout 6 hours
Case Size14.5 * 8.6 * 3.2cm
Battery IncludedYes
DIY SuppliesElectrical
OriginMainland China

6.2. Oscilloscope Parameters

Parameter Specification
Channels2
Real-time sample rate250MSa/s
Bandwidth120MHz (CH1 Only), 60MHz (CH1+CH2)
Equivalent sampling500M
Rise time<3ns
Storage128Kb
Impedance1MΩ
TimeBase5ns - 10s
Peak voltage±40V (1x), ±400V (10x)
Trigger modeAuto/Normal/Single
Trigger typeRise/Fall
Display modeYT / XY / Roll
PersistenceNone / 1s / ∞
CouplingAC/DC
Auto modeOneKey-auto / Fully-auto
SensitivityX1:10mV/div-10V/div, X10:100mV/div-100V/div
Measure items14 types
DC Offset±2%
XY modeYes
ScreenshotYes
Frequency±0.01%
Zoom modeYes
FFTYes
Generator waveSin / Square / Triangle
Generator Vol2.5V ±0.05
Generator freq1Hz - 2MHz

6.3. Multimeter Parameters

Function Range Precision
DC voltage600mV/6.00V/60.0V/600V/750V±(0.5%+3)
AC voltage600mV/6.00V/60.0V/600V±(1%+3)
DC current600mA / 10A±(2%+5)
AC current600mA / 10A±(3%+5)
Resistance600.0Ω, 6.000kΩ/60.00kΩ/600.0kΩ, 6.000MΩ, 60.00MΩ±(1.5%+3), ±(1%+3), ±(1.5%+5), ±(3%+3)
Capacitance60.00nF/600.0nF/6.000μF, 60.00μF/600.0μF±(5%+5), ±(10%+5)
Diode0.0V~3.3V, 3.3V higher display OL
ContinuitySound at 50Ω and below

Current Note: 600mA hole with 1A fuse, 10A hole without fuse.

7. Troubleshooting

  • Device does not power on: Ensure the device is fully charged. Connect it to a 5V Type-C power source and allow it to charge for a while before attempting to power on again.
  • No waveform displayed in Oscilloscope mode:
    • Check if probes are correctly connected to the BNC inputs and the circuit under test.
    • Press the 'Auto' button to automatically adjust the waveform.
    • Verify the trigger settings (mode, level, source) are appropriate for the signal being measured.
    • Adjust the Time Base and Sensitivity settings.
  • Multimeter readings are incorrect:
    • Ensure test leads are correctly inserted into the appropriate terminals (VΩ, 10A, COM).
    • Select the correct measurement function (DCV, ACV, Resistance, etc.) and range.
    • Check the continuity of the test leads.
  • Signal generator output is not as expected:
    • Verify the selected waveform type, frequency, and duty cycle settings.
    • Ensure the output is connected to a suitable load or measurement device.
  • Screen is unresponsive or frozen: Try restarting the device by holding down the power button. If the issue persists, contact support.

8. User Tips

  • Probe Calibration: Regularly calibrate your oscilloscope probes for accurate measurements. Most probes have a compensation adjustment screw.
  • Understanding Auto Mode: While 'Auto' mode is convenient, learning to manually adjust time base, voltage sensitivity, and trigger settings will give you more control and understanding of your signals.
  • Safety First: Always be mindful of voltage limits and proper connection techniques, especially when working with high voltages. The DSO3D12 has anti-burn protection, but caution is always advised.
  • Experiment with Features: Explore features like FFT and XY mode to gain deeper insights into your circuits.
  • Keep Software Updated: Check the manufacturer's website for any firmware updates that might improve performance or add new features.

9. Warranty and Support

The ZEEWEII DSO3D12 comes with a standard manufacturer's warranty. For specific warranty terms, technical support, or service inquiries, please refer to the warranty card included with your product or contact ZEEWEII customer service directly. Keep your purchase receipt as proof of purchase.

© 2023 ZEEWEII. All rights reserved.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.