1. Introduction
The ZEEWEII DSO3D12 is a compact and powerful 3-in-1 device, integrating a digital oscilloscope, a high-precision multimeter, and a signal generator. Designed for a wide range of applications from basic R&D and education to car repair and electronics enthusiasts, it offers a 120MHz bandwidth, dual-channel operation, and a clear 3.2-inch HD IPS display. This manual provides detailed instructions for setting up, operating, and maintaining your device.
2. What's in the Box
Please check the contents of your package against the list below. If any items are missing or damaged, contact your vendor immediately.
- ZEEWEII DSO3D12 Main Unit
- Oscilloscope Probes (x2)
- Multimeter Test Leads (x1 pair)
- USB Type-C Charging Cable
- Mini Screwdriver for probe adjustment
- Color Rings for probe identification
- User Manual (this document)
Device Dimensions: 145mm (Length) x 86mm (Height) x 32mm (Width)
3. Setup and Initial Use
- Charging the Device: Connect the provided USB Type-C cable to the device's charging port and a 5V power adapter. The device has a built-in battery with approximately 6 hours of battery life.
- Power On/Off: Press and hold the power button (usually located on the side or top) to turn the device on or off.
- Connecting Probes:
- Oscilloscope Probes: Connect the BNC connectors of the oscilloscope probes to the CH1 and CH2 inputs on the top of the device. Ensure a secure connection.
- Multimeter Test Leads: Connect the red test lead to the 'VΩ' or '10A' terminal and the black test lead to the 'COM' terminal for multimeter functions.
- Language Selection: The device supports Chinese and English. Navigate to the settings menu to select your preferred language.
4. Operating Instructions
The DSO3D12 features a user-friendly interface with dedicated buttons for various functions. The 3.2-inch HD IPS display provides clear visuals with a full viewing angle.
4.1. Oscilloscope Mode
To enter Oscilloscope mode, select 'OSCOPE' from the main menu. The device supports dual-channel operation, allowing simultaneous measurement and display of two signal waveforms.
- One-Key Auto: Press the 'Auto' button for automatic waveform detection and display. This feature simplifies setup for quick measurements.
- Dual Channel (CH1/CH2): Use the 'CH1' and 'CH2' buttons to switch between channels or enable dual-channel display. Channel 2 waveforms can be set to green, cyan, or purple for differentiation.
- Trigger Settings: Access trigger settings via the 'TrigMode' button. Options include Auto, Normal, and Single trigger types. Trigger edge can be set to Rise or Fall, and the trigger level can be Manual or Auto. Source can be CH1 or CH2.
- Cursor Measurement: Use the 'CurX' and 'CurY' buttons to activate X and Y cursors. X cursors measure time intervals (e.g., between pulses), while Y cursors measure voltage differences at two points.
- FFT Spectrum: The Fast Fourier Transform (FFT) function converts waveforms from the time domain to the frequency domain, allowing analysis of frequency components. Supports linear and logarithmic display. Note: FFT does not support frequency measurement.
- XY Mode: This mode combines the waveforms of two channels to form an image, useful for observing Lissajous figures and phase relationships.
- Waveform Save/View: Press the 'Save' button to capture the current screen waveform. You can browse saved waveforms as thumbnails and delete unwanted ones.
- Reference Waveform: The device supports latching reference waveforms, allowing you to statically display a waveform for comparison while dynamic waveforms continue to refresh.
4.2. Multimeter Mode
Select 'DMM' from the main menu to access the digital multimeter functions. The DSO3D12 features a high-precision true RMS multimeter with isolation from the oscilloscope circuit, allowing simultaneous use.
- Measurements: The multimeter can measure DC/AC Voltage, DC/AC Current, Resistance, Capacitance, Diode, and Continuity.
- Simultaneous Use: When measuring low voltage or resistance, the oscilloscope and multimeter can be used simultaneously, with the multimeter display appearing in a small window in the upper right corner of the screen.
- Safety: The device incorporates a safe design with peak 400V anti-burn protection, utilizing an isolation transformer and optocoupler chip to isolate the multimeter from the oscilloscope.
4.3. Signal Generator Mode
Select 'GEN' from the main menu to activate the built-in waveform signal generator. This function allows you to output various test signals.
- Waveform Types: Output sine wave, square wave, and triangle wave.
- Voltage Amplitude: Fixed at 2.5V.
- Frequency: Adjustable from 1Hz to 2MHz.
- Square Wave Duty Cycle: Adjustable from 1% to 99%.
5. Features Overview
The ZEEWEII DSO3D12 is packed with features to enhance your testing and measurement experience:
- High Bandwidth & Sampling Rate: 120MHz bandwidth and 500M equivalent sampling rate (250MS/s real-time sampling rate).
- Fully Automatic Operation: One-key automatic and fully automatic modes for quick and easy waveform adjustment, ideal for beginners.
- Rich Measurement Items: Supports 14 types of automatic measurement items for comprehensive analysis.
- Multi-Field Application: Suitable for basic R&D, education, car repair, power electronics, audio, radio amateur, circuit failure diagnosis, bus waveform analysis, and crystal waveform analysis.
6. Specifications
Below are the detailed technical specifications for the ZEEWEII DSO3D12.
6.1. General Parameters
| Feature | Specification |
|---|---|
| Model | DSO3D12 |
| Screen Size | 3.2 inch |
| Language | Chinese / English |
| Bracket | Collapsible stand |
| Key Type | Soft silicone keys |
| Charging | TYPE-C 5V |
| Battery Time | About 6 hours |
| Case Size | 14.5 * 8.6 * 3.2cm |
| Battery Included | Yes |
| DIY Supplies | Electrical |
| Origin | Mainland China |
6.2. Oscilloscope Parameters
| Parameter | Specification |
|---|---|
| Channels | 2 |
| Real-time sample rate | 250MSa/s |
| Bandwidth | 120MHz (CH1 Only), 60MHz (CH1+CH2) |
| Equivalent sampling | 500M |
| Rise time | <3ns |
| Storage | 128Kb |
| Impedance | 1MΩ |
| TimeBase | 5ns - 10s |
| Peak voltage | ±40V (1x), ±400V (10x) |
| Trigger mode | Auto/Normal/Single |
| Trigger type | Rise/Fall |
| Display mode | YT / XY / Roll |
| Persistence | None / 1s / ∞ |
| Coupling | AC/DC |
| Auto mode | OneKey-auto / Fully-auto |
| Sensitivity | X1:10mV/div-10V/div, X10:100mV/div-100V/div |
| Measure items | 14 types |
| DC Offset | ±2% |
| XY mode | Yes |
| Screenshot | Yes |
| Frequency | ±0.01% |
| Zoom mode | Yes |
| FFT | Yes |
| Generator wave | Sin / Square / Triangle |
| Generator Vol | 2.5V ±0.05 |
| Generator freq | 1Hz - 2MHz |
6.3. Multimeter Parameters
| Function | Range | Precision |
|---|---|---|
| DC voltage | 600mV/6.00V/60.0V/600V/750V | ±(0.5%+3) |
| AC voltage | 600mV/6.00V/60.0V/600V | ±(1%+3) |
| DC current | 600mA / 10A | ±(2%+5) |
| AC current | 600mA / 10A | ±(3%+5) |
| Resistance | 600.0Ω, 6.000kΩ/60.00kΩ/600.0kΩ, 6.000MΩ, 60.00MΩ | ±(1.5%+3), ±(1%+3), ±(1.5%+5), ±(3%+3) |
| Capacitance | 60.00nF/600.0nF/6.000μF, 60.00μF/600.0μF | ±(5%+5), ±(10%+5) |
| Diode | 0.0V~3.3V, 3.3V higher display OL | |
| Continuity | Sound at 50Ω and below |
Current Note: 600mA hole with 1A fuse, 10A hole without fuse.
7. Troubleshooting
- Device does not power on: Ensure the device is fully charged. Connect it to a 5V Type-C power source and allow it to charge for a while before attempting to power on again.
- No waveform displayed in Oscilloscope mode:
- Check if probes are correctly connected to the BNC inputs and the circuit under test.
- Press the 'Auto' button to automatically adjust the waveform.
- Verify the trigger settings (mode, level, source) are appropriate for the signal being measured.
- Adjust the Time Base and Sensitivity settings.
- Multimeter readings are incorrect:
- Ensure test leads are correctly inserted into the appropriate terminals (VΩ, 10A, COM).
- Select the correct measurement function (DCV, ACV, Resistance, etc.) and range.
- Check the continuity of the test leads.
- Signal generator output is not as expected:
- Verify the selected waveform type, frequency, and duty cycle settings.
- Ensure the output is connected to a suitable load or measurement device.
- Screen is unresponsive or frozen: Try restarting the device by holding down the power button. If the issue persists, contact support.
8. User Tips
- Probe Calibration: Regularly calibrate your oscilloscope probes for accurate measurements. Most probes have a compensation adjustment screw.
- Understanding Auto Mode: While 'Auto' mode is convenient, learning to manually adjust time base, voltage sensitivity, and trigger settings will give you more control and understanding of your signals.
- Safety First: Always be mindful of voltage limits and proper connection techniques, especially when working with high voltages. The DSO3D12 has anti-burn protection, but caution is always advised.
- Experiment with Features: Explore features like FFT and XY mode to gain deeper insights into your circuits.
- Keep Software Updated: Check the manufacturer's website for any firmware updates that might improve performance or add new features.
9. Warranty and Support
The ZEEWEII DSO3D12 comes with a standard manufacturer's warranty. For specific warranty terms, technical support, or service inquiries, please refer to the warranty card included with your product or contact ZEEWEII customer service directly. Keep your purchase receipt as proof of purchase.