1. Introduction

The NJTY T1 is a compact, fully intelligent digital multimeter designed for precise and automatic electrical measurements. Featuring True RMS measurement, non-contact voltage (NCV) detection, and an auto-ranging function, it simplifies electrical testing for both professionals and DIY enthusiasts. Its anti-burn design enhances safety during operation.

NJTY T1 Digital Multimeter held in hand, displaying 'Auto' and highlighting features like True RMS, NCV, and Auto-off.
The NJTY T1 Multimeter, highlighting its intelligent features and compact design.

2. Safety Information

Always observe basic safety precautions when using this multimeter to avoid personal injury or damage to the meter or equipment under test.

  • Read and understand all instructions in this manual before use.
  • Do not exceed the maximum input values specified for each function.
  • Never use the meter on circuits that exceed 600V AC/DC.
  • Ensure the test leads are properly connected and in good condition before each use.
  • Do not use the meter if it appears damaged or if the battery cover is not securely closed.
  • To avoid electrical shock, always remove test leads from the circuit and power off the device before opening the battery cover or case.
  • Keep hands and fingers behind the probe barriers during measurements.
  • Be cautious when working with voltages above 30V AC RMS, 42V peak, or 60V DC, as they pose a shock hazard.
Back of the NJTY T1 Multimeter showing a warning label to remove test leads before opening the battery cover.
Safety warning on the back of the multimeter regarding battery replacement.

3. Product Overview

The NJTY T1 Digital Multimeter is designed for ease of use with its fully automatic operation and compact size. Key components and features include:

Labeled diagram of the NJTY T1 Multimeter showing its components: NCV sensing area, Flashlight, Pull string, Display screen, Data hold button/NCV button, Flashlight/backlight button, Power on/off button, Negative terminal socket, Positive terminal socket.
Diagram of the NJTY T1 Multimeter's main components.

Key Features:

  • True RMS Measurement: Provides accurate readings for non-sinusoidal waveforms.
  • Auto-Ranging: Automatically selects the correct measurement range, eliminating the need for manual gear changes.
  • Non-Contact Voltage (NCV) Detection: Safely detects AC voltage without direct contact.
  • Continuity Buzzer: Audible indication for circuit continuity.
  • Data Hold: Freezes the displayed reading for easy recording.
  • Backlight & Flashlight: For improved visibility in dimly lit environments.
  • Auto Power-Off: Conserves battery life when not in use.
  • 4000 Counts Display: High-resolution digital display.
Function diagram showing icons for AC or DC voltage, Data retention (HOLD), Resistance, Smart mode (Auto), Diode, Beep continuity test, Flashlight, Screen Backlight, and Automatic shutdown.
Visual representation of the multimeter's electrical measurement functions.

4. Setup

4.1 Unpacking

Carefully unpack the contents and check for any damage or missing items. The package should include:

  • NJTY T1 Digital Multimeter
  • Test Leads (Red and Black)
  • User Manual
Contents of the NJTY T1 package including the multimeter, test leads, and user manual.
Package contents: Multimeter, test leads, and user manual.

4.2 Battery Installation

The NJTY T1 multimeter requires 2 x AAA 1.5V batteries (not included). To install or replace batteries:

  1. Ensure the multimeter is powered off and disconnect all test leads from the input terminals and any circuits.
  2. Locate the battery compartment cover on the back of the meter.
  3. Use a screwdriver to loosen the screw on the battery cover and remove the cover.
  4. Insert two AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  5. Replace the battery cover and tighten the screw securely.
Back of the NJTY T1 Multimeter with the battery compartment open, showing two AAA batteries installed.
Battery compartment showing installation of 2xAAA batteries.

5. Operating Instructions

5.1 Power On/Off

Press the red power button (U) to turn the multimeter on or off. The meter will automatically enter 'Auto' mode upon startup.

5.2 Automatic Measurement (Auto Mode)

The T1 multimeter features an intelligent auto-ranging function. When powered on, it defaults to 'Auto' mode, automatically identifying and measuring AC/DC voltage, resistance, and continuity without requiring manual selection of ranges or functions. Simply connect the test leads to the circuit, and the meter will display the appropriate reading.

NJTY T1 Multimeter displaying 'Auto' on its screen, indicating automatic measurement mode.
The multimeter in 'Auto' mode, ready for intelligent measurement.

5.3 AC Voltage Test

  1. Ensure the meter is in 'Auto' mode.
  2. Insert the red test lead into the positive terminal socket and the black test lead into the negative terminal socket.
  3. Carefully touch the test probes to the AC voltage source (e.g., wall outlet).
  4. The display will show the AC voltage reading.
NJTY T1 Multimeter measuring AC voltage from a wall outlet, displaying '234.7 VAC'.
Example of AC voltage measurement.

5.4 DC Voltage Test

  1. Ensure the meter is in 'Auto' mode.
  2. Insert the red test lead into the positive terminal socket and the black test lead into the negative terminal socket.
  3. Carefully touch the test probes to the DC voltage source (e.g., battery terminals).
  4. The display will show the DC voltage reading.
NJTY T1 Multimeter measuring DC voltage from a 9V battery, displaying '9.10 VDC'.
Example of DC voltage measurement.

5.5 Resistance Test

  1. Ensure the meter is in 'Auto' mode.
  2. Insert the red test lead into the positive terminal socket and the black test lead into the negative terminal socket.
  3. Connect the test probes across the component to measure its resistance.
  4. The display will show the resistance reading in Ohms (Ω), Kilo-ohms (kΩ), or Mega-ohms (MΩ).
NJTY T1 Multimeter measuring resistance of a resistor, displaying '4.46 MΩ'.
Example of resistance measurement.

5.6 Continuity Test

  1. Ensure the meter is in 'Auto' mode.
  2. Insert the red test lead into the positive terminal socket and the black test lead into the negative terminal socket.
  3. Connect the test probes across the circuit or component you wish to test for continuity.
  4. If continuity exists (resistance is low), the meter will emit an audible beep and the buzzer indicator light will illuminate. The display will typically show a very low resistance value or '0'.
NJTY T1 Multimeter performing a continuity test, showing '0' on the display and a red buzzer indicator light.
Continuity test with buzzer indicator light.

5.7 Non-Contact Voltage (NCV) Test

  1. Press the 'HOLD NCV' button briefly to activate NCV mode. The display may show 'NCV'.
  2. Move the top end of the multimeter (NCV sensing area) close to an AC voltage source (e.g., a live wire).
  3. If AC voltage is detected, the meter will beep, and the NCV indicator light will flash. The display may show dashes or a changing pattern to indicate detection.
NJTY T1 Multimeter performing a Non-contact Voltage (NCV) test near a power outlet, displaying '---' to indicate detection.
Non-Contact Voltage (NCV) field induction test.

5.8 Data Hold Function

During any measurement, briefly press the 'HOLD NCV' button to freeze the current reading on the display. Press it again to release the hold and resume live measurements.

5.9 Flashlight and Backlight

Press the flashlight/backlight button (*/Flashlight icon) to turn on the display backlight for better visibility in low light. Press and hold the same button to activate the built-in flashlight for emergency lighting.

NJTY T1 Multimeter with its flashlight illuminated, displaying 'Auto'.
Multimeter with flashlight activated for emergency lighting.

6. Maintenance

6.1 Cleaning

Wipe the meter with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the input terminals free of dirt and moisture.

6.2 Battery Replacement

When the battery indicator appears on the display, replace the batteries as described in Section 4.2. Always use 2 x AAA 1.5V batteries.

6.3 Storage

If the meter is not to be used for an extended period, remove the batteries to prevent leakage and store it in a cool, dry place.

7. Troubleshooting

  • No Display / Weak Display: Check battery installation and replace batteries if necessary. Ensure the power button is pressed firmly.
  • Incorrect Readings:
    • Verify test lead connections are secure and not damaged.
    • Ensure the meter is in 'Auto' mode for general measurements.
    • Check if the component or circuit being tested is functioning correctly.
    • For True RMS measurements, ensure the meter is correctly interpreting the waveform.
  • No Continuity Beep: Ensure the circuit is complete and has very low resistance. Check test leads for breaks.
  • NCV Not Detecting: Ensure NCV mode is active. The NCV sensor needs to be close to a live AC voltage source.

8. Specifications

Function Parameter / Range
Model T1
AC Voltage 0.01V ~ 600V ± (0.8%+5)
DC Voltage 0.01V ~ 600V ± (1.0%+5)
Resistance 1Ω ~ 40MΩ ± (1.0%+10)
NCV Yes
Continuity Buzzer Yes
True RMS Yes
Back Light Yes
Underbattery display Yes
Auto power-off Yes
Data Hold Yes
Display 4000 counts, Digital Display
Product size 123L*61W*24Hmm
Product weight About 78g (No batteries)
Power supply 2*AAA batteries (1.5V)
Operating Mode Auto Range
DIY Supplies Electrical
Certification CE
Table of function parameters for the NJTY T1 Multimeter, including ranges and features.
Detailed function parameters and specifications.
Image showing the dimensions of the NJTY T1 Multimeter: 123mm length, 61mm width, 24mm height.
Physical dimensions of the NJTY T1 Multimeter.
Diagram comparing common multimeter measurement methods with True RMS measurement, highlighting the accuracy of True RMS for arbitrary waveforms.
Explanation of True RMS measurement accuracy.

9. User Tips

  • Leverage Auto Mode: For most common measurements (voltage, resistance, continuity), simply power on the device and let its intelligent auto-ranging feature do the work. This eliminates the need to manually select functions, making testing quicker and easier.
  • Check NCV First: Before touching any wires, use the NCV function to quickly check for live AC voltage, enhancing safety.
  • Use Data Hold: In situations where the display is hard to read or you need to record a value, use the 'HOLD' function to freeze the reading.

10. Warranty & Support

For any questions, technical support, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase records for reference.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.