1. Introduction
The PTH-10C Mini Carbon Dioxide Detector is a compact and portable device designed to accurately measure carbon dioxide (CO2) levels, temperature, and humidity in indoor environments. This device helps assess ventilation quality and ensures a healthy indoor atmosphere for you and your family. Its mini size allows for easy portability, making it suitable for use in various locations such as homes, offices, and agricultural settings.
2. Product Overview
2.1 Components and Display
Familiarize yourself with the key components and display indicators of your PTH-10C detector:

- Lanyard Hole: For attaching a lanyard for easy carrying.
- Vent Hole: Allows air circulation for accurate sensor readings.
- Buzzer Siren: Emits an audible alarm when CO2 levels exceed safe thresholds.
- Charging Port: USB Type-C port for charging the device.
- Temperature and Humidity Sensor: Detects ambient temperature and humidity.
- CO2 Concentration Display: Shows the current CO2 level in parts per million (ppm).
- Battery Level Indicator: Displays the remaining battery charge.
- Temperature Display: Shows the current ambient temperature.
- Humidity Display: Shows the current ambient humidity percentage.
- Function Button: Used for various operations, including activating the display from standby.
2.2 CO2 Level Indicators
The device features a visual indicator system around the CO2 display to quickly convey air quality:

- Green Zone (Good): CO2 concentration between 400 and 699 ppm. Indicates a low CO2 level and good air quality.
- Yellow Zone (Warning): CO2 concentration between 700 and 1500 ppm. Indicates an alert level; an audible alarm may sound (in initial default state).
- Red Zone (Bad): CO2 concentration above 1500 ppm. Indicates a dangerous level; an audible alarm will sound (in initial default state).
3. Specifications
| Feature | Specification |
|---|---|
| Model Number | PTH-10C |
| Brand Name | meterk |
| Display | LCD display |
| CO2 Concentration Measurement Range | 400-5000ppm |
| Temperature Measurement Range | 0℃-50℃ (±1.5℃) / 32℉-122℉ (±2.7℉) |
| Humidity Measurement Range | 20%-80% (±5%) |
| Battery | Built-in 3.7V 1000mAh lithium ion battery |
| Charging Method | USB Type-C |
| Charging Time | Approx. 2.5 hours |
| Working Time | Approx. 12 hours |
| Storage Temperature | -10℃-55℃ / 14℉-131℉ |
| Material | ABS |
| Item Size | 76 * 70 * 30 mm / 2.99 * 2.76 * 1.18 inch |
| Item Weight | 83g / 2.93oz |
| Certification | CE |
4. Setup
4.1 Initial Charging
Before first use, fully charge the device. Connect the supplied Type-C cable to the charging port on the detector and plug the other end into a standard USB power adapter (not included). Charging typically takes about 2.5 hours. The battery level indicator on the display will show charging status.

4.2 Power On/Off
The device typically powers on automatically when charged or when the function button is pressed. To turn off or enter standby, follow the instructions in the operating section.
5. Operating Instructions
5.1 Real-time Monitoring
Once powered on, the PTH-10C detector will begin real-time monitoring of CO2 concentration, temperature, and humidity. The readings will be displayed on the LCD screen.
5.2 Standby Mode and Display Activation
- The screen will automatically turn off after 5 minutes of inactivity to conserve battery, entering a standby mode.
- To view the CO2 concentration and other readings from standby mode, short press the function button. The display will remain active for 1 minute before returning to standby.
5.3 CO2 Alarm Function
The device is equipped with an audible alarm system:
- If the carbon dioxide concentration exceeds 1000ppm, an audible alarm will be issued immediately (in the initial default state).
- Refer to the CO2 Level Indicators (Section 2.2) for a visual understanding of different concentration ranges.
5.4 Application Areas
The PTH-10C is suitable for monitoring air quality in various indoor environments:
- Home environments (living rooms, bedrooms, kitchens)
- Offices and workspaces
- Agricultural planting areas and greenhouses
- Production warehouses and raw material processing facilities
- Any indoor space where ventilation assessment is crucial.

6. Maintenance
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place within the specified storage temperature range (-10℃ to 55℃ / 14℉ to 131℉).
- Avoid Obstruction: Ensure the vent holes are not blocked to maintain accurate readings.
- Battery Care: For optimal battery life, avoid fully discharging the battery frequently. Charge the device regularly.
7. Troubleshooting
- Device not turning on: Ensure the device is fully charged. Connect it to a power source using the Type-C cable.
- Inaccurate readings: Ensure the vent holes are not obstructed. Move the device to a different location to rule out localized issues. Allow some time for the sensor to stabilize after moving.
- Display not active: Short press the function button to activate the display from standby mode.
- Alarm not sounding: Check if the CO2 concentration is above 1000ppm. If the alarm is still not sounding, the device may require service.
8. User Tips
- For best results, place the detector in a central location within the room you wish to monitor, away from direct drafts or heat sources.
- Regularly check the battery level to ensure continuous monitoring.
- Consider the CO2 readings in conjunction with how you feel. High CO2 levels can indicate poor ventilation, which might lead to drowsiness or headaches.
9. Warranty and Support
For warranty information or technical support, please refer to the seller's policies or contact the point of purchase. Keep your purchase receipt as proof of purchase.