1. Introduction

Thank you for choosing the VEVOR CO-01 Carbon Monoxide Detector. This device is designed to provide accurate and real-time detection of carbon monoxide (CO) concentrations, ensuring your safety in various environments. Equipped with a high-sensitivity electrochemical sensor, visual and audible alarms, and a temperature sensor, the CO-01 is a reliable tool for both home and industrial use. Please read this manual thoroughly before operation to ensure proper use and maintenance.

2. Safety Information

  • Always operate the device in accordance with the instructions provided in this manual.
  • Do not attempt to open or modify the device. This may void the warranty and pose safety risks.
  • Keep the device away from extreme temperatures, humidity, and direct sunlight.
  • Ensure the battery compartment is securely closed during operation.
  • This device is a detection tool and should not be used as a substitute for proper ventilation or other safety measures.
  • If an alarm sounds, immediately move to fresh air and investigate the source of CO.

3. Package Contents

Verify that all items are present in your package:

  • 1 x VEVOR CO-01 Carbon Monoxide Detector
  • 1 x Portable Bag
  • 1 x Small Phillips Screwdriver
  • 3 x AAA 1.5V Alkaline Batteries
VEVOR CO-01 Carbon Monoxide Detector and accessories
Figure 1: Package Contents and Product Dimensions

4. Product Overview

The VEVOR CO-01 Carbon Monoxide Detector features an intuitive panel for easy operation and a clear LCD display.

Labeled diagram of VEVOR CO-01 Carbon Monoxide Detector controls and display
Figure 2: Detector Components and Controls
  1. Electrochemical Sensor: High-sensitivity sensor for precise CO detection.
  2. LCD Display Screen: Shows CO concentration, temperature, and other indicators.
  3. Carbon Monoxide Value: Displays CO concentration in PPM.
  4. Temperature Value: Displays ambient temperature in °C or °F.
  5. MIN/MAX Key: Toggles between minimum and maximum recorded CO values.
  6. On/Off Button: Powers the device on or off.
  7. APO Button: Activates or cancels the Auto Power-Off function.
  8. HOLD Button: Freezes the current reading on the display.
  9. °C/°F Switch Button: Toggles between Celsius and Fahrenheit temperature units.

5. Setup

5.1 Battery Installation

  1. Locate the battery compartment on the back of the device.
  2. Use the provided small Phillips screwdriver to open the battery compartment cover.
  3. Insert three (3) AAA 1.5V alkaline batteries, ensuring correct polarity (+/-).
  4. Replace the battery compartment cover and secure it with the screw.
Image showing battery compartment and compact size of the detector
Figure 3: Battery Compartment and Handheld Design

6. Operating Instructions

6.1 Powering On/Off

  • To Power On: Press and hold the On/Off Button until the LCD screen illuminates.
  • To Power Off: Press and hold the On/Off Button until the screen turns off.

6.2 Taking Measurements

Upon powering on, the device will automatically begin detecting carbon monoxide and displaying the CO concentration in PPM, along with the ambient temperature.

6.3 Understanding CO Concentration Levels

The detector provides visual indicators for different CO concentration ranges:

  • Safe: 0 - 50 PPM
  • Warning: 51 - 200 PPM (Audible and visual alarm will activate)
  • Danger: 201 - 1000 PPM (Stronger audible and visual alarm will activate)
Diagram showing CO concentration levels: Safe, Warning, Danger
Figure 4: CO Concentration Level Indicators

6.4 Button Functions

  • MIN/MAX: Press this button to view the minimum and maximum CO readings recorded since the device was powered on. Press again to cycle through min, max, and current readings.
  • HOLD: Press this button to freeze the current CO and temperature readings on the display. Press again to resume real-time measurements.
  • APO (Auto Power-Off): The device has a default 10-minute auto-shutdown feature to conserve battery. Press the APO button to activate or cancel this function as needed. An icon on the display will indicate if APO is active.
  • °C/°F: Press this button to switch the temperature display between Celsius (°C) and Fahrenheit (°F).

6.5 Alarm System

When CO levels exceed the preset warning or danger thresholds, the device will emit both an audible alarm and a visual alarm (red backlight on the LCD screen) to alert you. Take immediate action if an alarm sounds.

Image showing the detector with sound and light alarm icons
Figure 5: Dual Alarm System (Sound and Light)

7. Maintenance

7.1 Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the casing or internal components.

7.2 Battery Replacement

When the battery indicator on the LCD screen shows low power, replace the batteries promptly following the instructions in Section 5.1.

7.3 Sensor Care

The electrochemical sensor is a delicate component. Avoid exposing it to harsh chemicals, excessive dust, or physical impact. Do not block the sensor opening.

8. Troubleshooting

Problem Possible Cause Solution
Device does not power on. Dead or incorrectly installed batteries. Replace batteries with new AAA 1.5V alkaline batteries, ensuring correct polarity.
Inaccurate or inconsistent readings. Sensor blocked or contaminated; device not in stable environment. Ensure sensor is clear. Move to a well-ventilated area away from strong air currents or chemical fumes.
Alarm sounds frequently without apparent CO source. False alarm due to interfering gases or actual low-level CO presence. Ventilate the area. If alarm persists, evacuate and seek professional help to check for CO leaks.
LCD backlight not working. Low battery or internal fault. Replace batteries. If issue persists, contact customer support.

9. Specifications

Feature Detail
Model Number CO-01
Main Material ABS
Power Type Battery-Powered (3 x AAA 1.5V)
Operating Voltage 4.5V
Measuring Range 0-1000 PPM
Operating Temperature 32°F-122°F / 0°C-50°C
Operating Humidity 0-70%RH
Operating Current About 5mA
Product Weight 0.29 lbs / 0.13 kg
Product Dimensions (L x W x H) 6.1 x 1.97 x 1.22 in / 155 x 50 x 31 mm
Display Screen LCD (Backlit)
Certification CE

10. User Tips

  • Regular Testing: Periodically test the detector in different areas of your home or workspace to ensure it's functioning correctly.
  • Placement: For optimal detection, hold the detector near potential CO sources (e.g., gas appliances, vehicle exhausts) or in areas where CO might accumulate.
  • Battery Life: Always keep spare AAA batteries on hand, especially if you use the device frequently or in critical applications.
  • Environmental Factors: Be aware that extreme temperatures or humidity can affect sensor performance. Operate within the specified environmental conditions.
  • Travel Companion: Its compact size makes it ideal for travel, especially when staying in hotels or RVs, to check for CO safety.
Images showing various applications of the CO detector in different settings like bedroom, bathroom, RV, and truck
Figure 6: Versatile Applications of the CO Detector

11. Warranty & Support

For warranty information, technical support, or any questions regarding your VEVOR CO-01 Carbon Monoxide Detector, please contact VEVOR customer service through the official website or your purchase platform. Please have your model number (CO-01) and purchase details ready when contacting support.

© 2023 VEVOR. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.