VEVOR 15KW 30-100 KHz

Rate this product if you’ve used it
Contents

VEVOR High Frequency Induction Furnace 15KW 30-100 KHz User Manual

Model: 15KW 30-100 KHz

1. Introduction

The VEVOR High Frequency Induction Furnace is a powerful and efficient heating device designed for various metal processing applications. Utilizing advanced MOSFET and IGBT power units, it offers rapid and precise heating for materials such as gold, silver, copper, and steel. This high-frequency 15 kW induction heater employs advanced technology, ensuring simple operation, high efficiency, low energy consumption, and high output power. It is widely used in processes like brazing, silver welding, hot forging, melting, and quenching. This manual provides essential information for the safe and effective operation and maintenance of your induction heater.

2. Safety Instructions

WARNING: Failure to follow these safety instructions may result in serious injury or property damage.

  • Always ensure the unit is properly grounded to prevent electrical shock.
  • Connect the unit to a power supply that matches the specified voltage (Single phase 110 V, 60 Hz).
  • Ensure the water cooling system is properly connected and functioning before operation. Insufficient cooling can lead to overheating and damage to the machine.
  • Wear appropriate personal protective equipment (PPE), including heat-resistant gloves, eye protection, and protective clothing, when operating the furnace.
  • Keep flammable materials away from the heating area. The maximum heating temperature can reach 2200 ℃ (3992 ℉).
  • Do not touch the induction coil or workpiece during or immediately after heating, as they will be extremely hot.
  • Ensure adequate ventilation in the work area to dissipate heat and any fumes.
  • Never operate the machine if any safety features are bypassed or malfunctioning.
  • Only qualified personnel should perform maintenance or repairs.

3. Package Contents

Carefully unpack the box and ensure all items listed below are present and undamaged.

  • 1 x 15 KW High Frequency Induction Heater Furnace
  • 1 x Heating Coil
  • 1 x Foot Switch
  • 1 x English Manual
VEVOR 15KW Induction Furnace and included accessories
Figure 3.1: Main unit with heating coil, foot switch, and clamps.

4. Specifications

ParameterValue
Output Power15 KW
Output Current200 - 600 A
Fluctuating Frequency30 - 100 KHZ
Heating Time1-99 s (auto)
Input VoltageSingle phase 110 V, 60 Hz
Flow Rate of Cooling Water0.2 Mpa, 2 L / min
Water Temp. Protection Point40 ℃ (104 ℉)
Max. Heating Temperature2200 ℃ (3992 ℉)
Load Duration100%
CoolingWater cooling
Dimension55 x 22 x 47 cm (22 x 9 x 19 inch)
Weight18 kg (40 lbs)
CertificationCE
OriginMainland China

5. Setup

5.1 Unpacking and Placement

  • Remove the induction furnace and all accessories from the packaging.
  • Place the unit on a stable, level, and non-flammable surface in a well-ventilated area. Ensure there is sufficient space around the unit for air circulation and access to connections.

5.2 Electrical Connection

  • Connect the power cord to a single-phase 110V, 60Hz power outlet.
  • Ensure the power outlet is properly grounded to prevent electrical hazards.

5.3 Water Cooling System Connection

The induction furnace requires a continuous flow of cooling water to operate safely and efficiently. A water pump and reservoir (not included) are typically required.

  • Identify the 'Water In' and 'Water Out' ports on the rear of the unit.
  • Connect the 'Water In' port to the outlet of your water pump/cooling system.
  • Connect the 'Water Out' port to the return inlet of your water reservoir.
  • Ensure the water flow rate is at least 0.2 Mpa and 2 L/min.
  • Fill the cooling system with clean water.
Rear view of VEVOR Induction Furnace showing water connections and portable handle
Figure 5.1: Rear panel with water inlet/outlet connections.

5.4 Induction Coil Connection

  • Connect the ends of the heating coil to the brass terminals on the front panel of the induction furnace.
  • Ensure connections are tight and secure.
Close-up of the high quality induction coil connected to the furnace
Figure 5.2: Induction coil connected to the front panel.

5.5 Foot Switch Connection

  • Plug the foot switch cable into its designated port on the control panel.

6. Operating Instructions

6.1 Control Panel Overview

Digital control panel of the VEVOR Induction Furnace
Figure 6.1: Digital Control Panel.
  • Time Display: Shows 'Heat', 'Retain', 'Cool' status.
  • Heating Time (秒): Sets the duration for the initial heating phase (1-99 seconds).
  • Retaining Time (秒): Sets the duration for the holding/soaking phase (1-99 seconds).
  • Cooling Time (秒): Sets the duration for the cooling phase (1-99 seconds).
  • Output Current (A) Display: Shows the real-time output current.
  • Heat Power Adj (加热功率调节): Knob to adjust heating power.
  • Retain Power Adj (保温功率调节): Knob to adjust retaining power.
  • START/STOP Buttons: Initiate or halt the heating process.
  • Auto/Man Switch: Selects automatic or manual operation mode.
  • Status Indicators: LEDs for Power (Pow), Operation (Oper), Phase Failure (PhaseFail), Over Current, Over Voltage, Over Temp, Over Water, Lock.

6.2 Pre-Operation Checklist

  • Ensure all connections (power, water, coil, foot switch) are secure.
  • Verify that the water cooling system is running and providing adequate flow.
  • Place the workpiece or crucible within the induction coil.

6.3 Starting Operation

  1. Flip the main power switch to the 'ON' position. The control panel will illuminate.
  2. Set the desired 'Heating Time', 'Retaining Time', and 'Cooling Time' using the corresponding digital displays.
  3. Adjust the 'Heat Power Adj' and 'Retain Power Adj' knobs to your desired power levels. Start with lower settings and gradually increase as needed.
  4. Select either 'Auto' or 'Man' (Manual) mode using the switch. In 'Auto' mode, the machine will cycle through the set heating, retaining, and cooling times. In 'Man' mode, heating is controlled manually via the START/STOP buttons or foot switch.
  5. Press the 'START' button or activate the foot switch to begin the heating process.
  6. Monitor the 'Output Current (A)' display and the status indicators for any warnings.
  7. To stop heating, press the 'STOP' button or release the foot switch.

7. Maintenance

Regular maintenance ensures the longevity and safe operation of your induction furnace.

  • Cleaning: Keep the exterior of the unit clean and free of dust and debris. Use a dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Water Cooling System: Regularly check the water level and quality in your cooling reservoir. Replace or filter the water if it becomes dirty or contaminated. Ensure the water pump is functioning correctly and maintaining the required flow rate.
  • Induction Coil: Inspect the heating coil for any signs of damage, wear, or corrosion. Replace the coil if it is compromised.
  • Electrical Connections: Periodically check all electrical connections for tightness and signs of wear.
  • Ventilation: Ensure that the ventilation openings on the unit are not blocked to allow for proper heat dissipation.

8. Troubleshooting

The VEVOR Induction Furnace is equipped with multiple protection functions. If an issue occurs, the machine will automatically protect itself and illuminate a corresponding status indicator.

  • No Power: Check the main power switch, the power cord connection, and the circuit breaker at your power source.
  • No Heating / Weak Heating: Verify that the heating coil is properly connected and that the power settings ('Heat Power Adj') are correctly adjusted. Ensure the workpiece is correctly positioned within the coil.
  • Over Current / Over Voltage Indicator: This indicates an issue with the power supply or an improper load. Stop operation, check your power source, and ensure the workpiece/coil setup is appropriate for the machine's capacity.
  • Overheating / Over Water Indicator: This typically points to a problem with the water cooling system. Stop operation immediately. Check the water level, pump function, flow rate, and ensure there are no blockages in the cooling lines. The water temperature protection point is 40 ℃ (104 ℉).
  • Phase Failure Indicator: This suggests an issue with the electrical phase. Stop operation and consult a qualified electrician to check your power supply.
  • Load Malfunction: This could be due to an incorrect workpiece, a short circuit in the coil, or other load-related issues. Inspect the coil and workpiece for any abnormalities.

If the problem persists after troubleshooting, contact customer support.

9. User Tips

  • Always ensure the water cooling system is fully operational and providing sufficient flow before initiating any heating process. This is critical for preventing damage to the unit.
  • Match the size and type of your induction coil to the workpiece for optimal heating efficiency and to prevent unnecessary strain on the machine.
  • When starting a new heating task, begin with lower power settings and gradually increase them. This allows you to observe the material's response and fine-tune the process, avoiding rapid overheating.
  • For melting applications, use crucibles specifically designed for induction heating and compatible with the material being melted.
  • Familiarize yourself with the control panel settings and indicators. Understanding the 'Heating Time', 'Retaining Time', and 'Cooling Time' functions can help automate repetitive tasks and improve consistency.

10. Warranty & Support

For warranty information, technical support, or service inquiries, please contact VEVOR customer service or your authorized dealer. Keep your purchase receipt and product model number handy for faster assistance.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?