1. Introduction
The RIDEN RD6030 and RD6030-W are digital control DC adjustable step-down power supplies designed for various applications, including battery charging and general laboratory use. They offer high current output, precise resolution, and multiple protection features. The RD6030-W model includes Wi-Fi connectivity for mobile app control.

Figure 1: RIDEN RD6030/RD6030-W Digital Control DC Power Supply
Video 1: Product Overview of the RD6030/RD6030-W DC Power Supply, highlighting its features and capabilities.
2. Specifications
| Parameter | Value |
|---|---|
| Model | RD6030/RD6030-W |
| Input Voltage Range | 7-70.00V DC |
| Output Voltage Range | 0-60.00V |
| Output Current Range | 0-30.00A |
| Output Power Range | 0-1800W |
| Input Voltage Measurement Resolution | 0.01V |
| Output Voltage Resolution | 0.01V |
| Output Current Resolution | 0.01A |
| Battery Voltage Resolution | 0.01V |
| Input Voltage Measurement Accuracy | ±(1%+5 digits) |
| Output Voltage Accuracy | ±(0.3%+3 digits) |
| Output Current Accuracy | ±(0.5%+5 digits) |
| Battery Voltage Measurement Accuracy | ±(0.5%+3 digits) |
| Default Cutoff Current (Charging) | 100mA |
| Output Ripple Typical | 50mV@15A, 90mV@30A VPP |
| Working Temperature Range | -10℃ to 40℃ |
| External Sensor Temperature Detection Range | -10℃ to 100℃ / 0℉ to 200℉ |
| External Sensor Temperature Detection Accuracy | ±3℃/±6℉ |
| Constant Voltage Mode Response Time | 2ms (0.1A-5A Load) |
| Constant Voltage Mode Load Regulation | ±(0.1%+2 digits) |
| Constant Current Mode Load Regulation | ±(0.1%+3 digits) |
| Capacity Measurement Range | 0-9999.99Ah |
| Energy Measurement Range | 0-9999.99Wh |
| Capacity and Energy Statistical Error | ±2% |
| Buck Working Mode | (Input voltage ÷ 1.1) - 1 |
| Over Temperature Protection | System temperature > 80℃ |
| Screen Brightness Setting | 0-5 (6 levels in total) |
| Screen | 2.4 inch color HD display |
| Weight (with package) | About 0.74kg |
| Product Dimension | 167*81*69mm |
| Cooling Fan Start Condition | Output current > 8A or System temperature > 45℃ |
| Cooling Fan Shut Down Condition | Output current < 7.9A and System temperature < 40℃ |

Figure 2: Detailed Parameter Table
3. Setup and Assembly
This section provides instructions for assembling the RD6030/RD6030-W with the S800 aluminum cover (if purchased separately) and initial connections.
3.1. S800 Aluminum Cover Assembly (Optional)
If you have purchased the S800 aluminum cover, follow these steps for assembly. Ensure all components are present before starting.
- Unpack the S800 aluminum cover kit, which includes the cover, screws, wires, power switch, AC inlet, and a small PCB.
- Carefully mount the RD6030/RD6030-W power supply module into the S800 case.
- Connect the provided wires for input power, output terminals, and internal components like the fan and temperature sensor.
- Install the AC inlet and power switch into their designated slots on the case.
- Secure all components with the provided screws.

Figure 3: S800 Case Assembly - Initial Steps and Component Placement

Figure 4: S800 Case Assembly - Wiring and Finalizing Connections
3.2. Initial Connections
Before powering on the device, ensure all connections are correct:
- Connect the DC input power source (7-70V) to the input terminals.
- Connect your load to the output terminals. For 30A output, it is recommended to use copper cable lugs with 4 square millimeter or 11AWG wire.
- If using the RD6030-W model, ensure the Wi-Fi communication board is correctly installed.
- If using an external temperature sensor, connect it to the designated socket.

Figure 5: Recommended wiring for 30A output using pure copper terminal connectors.

Figure 6: Rich Configuration - Internal components including fuses, input/output terminals, fan, temperature sensor, and Wi-Fi board (for -W model).
4. Operating Instructions
4.1. Basic Operation
- Power On: After connecting the input power, press the ON/OFF button to power on the device.
- Setting Voltage/Current: Use the 'V-SET' and 'I-SET' buttons along with the rotary encoder to adjust the desired output voltage and current limits.
- Output Control: Press the green ON/OFF button on the front panel to enable or disable the output.
- Memory Functions: Use the M1-M9 buttons to save and recall frequently used voltage/current settings.
4.2. Display Styles
The system defaults to the classic display style. Click the 'SHIFT' button to cycle through Classic, Detailed, and Curve display styles.
- Classic Style: Shows primary voltage, current, power, input voltage, set voltage/current, and temperature.
- Detailed Style: Provides more comprehensive information including battery charging status, Ah/Wh accumulation, and OCP/OVP status.
- Curve Style: Displays real-time voltage and current curves for monitoring trends.

Figure 7: Switch between Classic, Detailed, and Curve display styles.
4.3. PC Software Control
The RD6030/RD6030-W can be monitored and controlled via PC software (supports Windows 7 and above).
- Download the PC software from the official link provided in Section 7.
- Connect the power supply to your PC via USB.
- The software allows for setting parameters, monitoring output, viewing graphs, and managing data.

Figure 8: PC Software for monitoring and controlling the power supply.

Figure 9: PC Software offers a friendly interface with powerful functions for easy and fast control.
4.4. Mobile App Control (RD6030-W Only)
The RD6030-W model supports mobile app control via Bluetooth (Android and iOS).
- Download the appropriate app from the official links or app stores (see Section 7).
- Pair your mobile device with the RD6030-W via Bluetooth.
- The app provides an intuitive interface for setting parameters, monitoring output, and viewing data remotely.

Figure 10: Mobile App for Android and iOS, supporting Bluetooth control for the RD6030-W model.
5. Maintenance
Proper maintenance ensures the longevity and optimal performance of your power supply.
- Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
- Cooling Fan: The cooling fan operates automatically based on output current and system temperature. It starts when the output current exceeds 8A or the system temperature rises above 45℃. It stops when the output current is below 7.9A and the system temperature is below 40℃. Ensure the fan vents are not obstructed.
- Storage: When not in use for extended periods, store the device in a cool, dry place.
- Firmware Updates: Firmware can be updated to optimize product experience and add new functions. Refer to Section 7 for update instructions.

Figure 11: Firmware can be updated in normal mode, or Boot Mode if normal startup fails.
6. Troubleshooting and Protections
6.1. Common Issues
- High-frequency noise from 1500W PSU: A high-frequency noise may occur when the switching power supply is unloaded. This is due to the PWM control chip skipping control cycles to reduce power consumption, which can lower the working frequency to an audible range. This is considered normal behavior. The noise level can vary slightly between units due to transformer production differences.
- Loud fan noise: The fan may run loudly, even when unloaded, if the ambient temperature is high. This is normal as it ensures proper cooling.
Recommendation: It is recommended to turn off the AC switch when the product is not in use to prevent unnecessary operation and noise.
6.2. Protection Features
The RD6030/RD6030-W incorporates multiple protection mechanisms to safeguard the device and connected loads:
- Abnormal Power-Up/Down Protection: Ensures stable voltage during power-up, power-down, and switch ON/OFF.
- Input Over-Voltage Protection (OVP): Protects against input overvoltage up to 100V. If input voltage exceeds 72V, a warning prompt appears. If it exceeds 75V, the product power cutoff protection activates, and the display may show no input.
- Output Reverse Connection Protection: If a battery is connected with reverse polarity (red to black), only the fuse will blow. The product itself will not be damaged abnormally. Note: Many power supplies explicitly state that batteries should not be connected in reverse.
- Charging Abnormal Protection: When using battery charging terminals, reverse connection will not cause damage. Voltage abnormalities are indicated, and the output will automatically cut off in case of full charge/overheating/power loss.

Figure 12: Overview of multiple protection features including Abnormal Power-Up/Down, Input Over-Voltage, Output Reverse Connection, and Charging Abnormal Protection.

Figure 13: Input Over-Voltage Protection warning and cutoff mechanisms. The product can withstand input over-voltage of 100V for up to 1 second.
7. User Tips
- PSU Compatibility: Be aware that a 1500W PSU provides 1500W output under 220V AC input (allowing RD6030 to output 1440W max), but only 1200W under 110V AC input (allowing RD6030 to output 1140W max). Choose your PSU carefully based on your region's AC input voltage.
- App Compatibility: There may be incompatibilities with certain mobile phone models and operating systems. It is recommended to install and test the app before purchasing the product, especially for older Android versions.
- Language Support: The device supports multiple languages, including Chinese, English, French, German, and Russian. More languages may be added in future firmware updates.
8. Support and Resources
For detailed operation instructions, PC software, and mobile app guides, please refer to the following resources:
- Operation Instructions, PC Software, and App Guides:
https://drive.google.com/drive/folders/1-AmpwEJDyvrYQgRLXdWias0caqHx9jJR?usp=sharing - Android App Download:
https://drive.google.com/drive/folders/1jwAnxKiQZKkxMWpQnv4rrPw2KQk9uY-z?usp=sharing (Supports Android 8.0 - 10.0)
Alternatively, search "Ruideng tech" on Google Play (Supports Android 8.0 and above). - iOS App Download:
Search "Ruideng tech" in the App Store (Supports iOS 10.0 - 13.4 System). - S800 Case Assembly Instructions:
https://drive.google.com/drive/folders/1-AmpwEJDyvrYQgRLXdWias0caqHx9jJR?usp=sharing