1. Introduction
The JIKONG JK Smart Battery Management System (BMS) is an intelligent protection board designed for large capacity series lithium battery packs. It features voltage acquisition, high current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection, a coulomb meter, Bluetooth communication, and optional GPS remote functions. It is compatible with lithium iron phosphate, ternary lithium, and lithium titanate battery types.
This protection board utilizes energy transfer active balancing technology with independent intellectual property rights, capable of achieving a maximum continuous 0.4A balance current. This high-current active equalization technology ensures battery consistency, improves battery range, and delays battery aging.
The BMS is supported by a mobile APP for Android and iOS operating systems. The APP connects via Bluetooth, allowing users to monitor battery status, modify protection parameters, and control charge/discharge switches. Its compact size, ease of operation, and comprehensive functions make it suitable for various applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.

2. Specifications
The JIKONG JK Smart BMS is available in various configurations, supporting different battery series and current ratings. Below are the general specifications and default parameters for the 60A and 80A protection boards.
2.1 General Product Properties
- Brand Name: JIKONG
- Type: LI-ION Battery BMS
- Certification: CE, FCC, RoHS
- Balance Function: Active Balanced BMS
- Hardware or Smart: SMART BMS
- Charge and Discharge Port: Common Port BMS
- Function: Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection
- Applications: Lithium battery rated (Power BMS, Energy Storage BMS, 3C Digital BMS)
- Origin: Mainland China
2.2 Technical Parameters (60A Protection Board)
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <800 | mW |
| Operating Temperature | -30-70 | °C |
| Max. Number of Collection Strings | 24 | String |
| Max. Balancing Current | 0.4 | A |
| Max. Charging Current | 60 | A |
| Max. Discharge Current | 60 | A |
| Max. Instantaneous Current | 120 | A |
| Max. Internal Loop Resistance | 1.53 | mΩ |
| Protective Plate Size | 136*103*17.6 | mm |
| Finished Weight | 260 | g |
2.3 Technical Parameters (80A Protection Board)
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <800 | mW |
| Operating Temperature | -30-70 | °C |
| Max. Number of Collection Strings | 24 | String |
| Max. Balancing Current | 0.4 | A |
| Max. Charging Current | 80 | A |
| Max. Discharge Current | 80 | A |
| Max. Instantaneous Current | 150 | A |
| Max. Internal Loop Resistance | 1.2 | mΩ |
| Protective Plate Size | 136*103*17.6 | mm |
| Finished Weight | 260 | g |
2.4 Default Parameters
| Parameter | Li-ion | LiFePO4 | LTO | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Maximum Balancing Current | 0.4 | 0.4 | 0.4 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 5 | 5 | 5 | µS |
| Short Circuit Protection Release Time | 30 | 30 | 30 | S |
| Charging Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Charge Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery Temperature | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection Temperature | -20 | -20 | -20 | °C |
| Charge Low Temperature Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection Temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature Protection Recovery Temperature | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |


3. Packing List
The standard package includes the following items:
- BMS x 1
- Sampling cable (75cm) x 2
- Temperature sensor NTC (40cm) x 1
- Power switch button (50cm) x 1
- Bolt screws x 2-6
- Exclusive packaging box x 1
Optional accessories such as heating function (H), built-in CANBUS core (C), and built-in integrated RS485 function (R) may be included depending on the specific model purchased.

4. Installation and Wiring
The JK-BD4AxxS-6P/8P series protection board is suitable for 7-24 series lithium battery packs. The wiring method varies depending on the number of cells in the battery pack. Always ensure proper connections to prevent damage or malfunction.
4.1 Pre-Installation Check
Before powering on the protection board, carefully check the following:
- Ensure the balance cables are properly connected to each cell.
- Verify that the P- (total negative) and B- (battery negative) connections are correct.
- Confirm that the protection board is securely fixed to the battery pack.
Incorrect connections can lead to abnormal operation, severe damage, or even fire.
4.2 Wiring Steps
- Connect all necessary cables, including balance wires, temperature sensors, and communication cables, to their respective ports on the BMS.
- Insert the main B-line and P-line cables into the designated terminals on the BMS.
- Connect the B-line and P-line to the battery pack's negative and positive terminals, respectively.

4.3 Example Wiring Diagrams



5. Operating Instructions
5.1 APP Installation
The JIKONG BMS features Bluetooth connectivity for monitoring and parameter adjustment via a mobile application. To install the APP:
- For iOS: Search for 'JK BMS' in the Apple App Store.
- For Android: Search for 'JK BMS' in the Google Play Store. Android Version 7 or higher is required.
- Alternatively, scan the QR code on the BMS panel or in the manual to download the APP.

5.2 Device Activation
The BMS does not have a physical power-on switch. It is designed for charging activation. After the battery assembly is complete, connect a charger (with a voltage 2V higher than the battery voltage) to activate the BMS.
The BMS also supports activation via a key switch or an external display. If you have these optional accessories, simply connect them to the display interface and press the button to activate the device.
5.3 Parameter Setting
Detailed instructions for setting parameters can be found within the APP. The APP allows you to adjust various protection values such as overcharge, over-discharge, overcurrent, temperature, and balance settings. Refer to the 'Instructions for Setting Protection Board Parameters' section within the APP for comprehensive guidance.



6. Key Features
6.1 Active Equalization (Lossless Balancing)
The BMS employs active equalization technology to transfer energy from higher-voltage cells to lower-voltage cells, minimizing energy loss. This process continues during charging, discharging, or idle states until the cell voltage difference is within the set range. Active balancing currents typically range from 0.4A to 2A, making it suitable for larger capacity battery packs without requiring additional cooling.


6.2 Protection Functions
- Overcharge Protection: Prevents battery damage by turning off charging when any cell exceeds the set overcharge voltage. Charging resumes when cell voltages drop below the recovery threshold.
- Over-discharge Protection: Shuts off discharge when any cell falls below the set undervoltage threshold, protecting the battery from deep discharge. Discharge resumes when cells recover above the threshold.
- Overcurrent Protection (Charge/Discharge): Monitors charging and discharging currents. If current exceeds the set limit for a specified delay, the BMS will interrupt the circuit.
- Over-temperature Protection (Charge/Discharge): Protects the battery from high temperatures during charging and discharging. The BMS will stop operation if temperatures exceed set limits and resume when they fall below recovery thresholds.
- Low Temperature Protection (Charge): Prevents charging at dangerously low temperatures. If the temperature falls below the set limit, charging is stopped and resumes when the temperature rises above the recovery threshold.
- Short Circuit Protection: Automatically detects and protects against short circuits. Users can adjust the short circuit protection delay and recovery time via the APP.
6.3 Additional Functions
- GPS/Display Interface: Reserved ports for optional GPS modules (for battery location) and external display screens (for viewing battery information).
- Heating Function (Optional): For use in cold environments, the BMS supports an optional heating function (10A current) to warm the battery and maintain optimal performance.
- Alarm Function (Optional): Provides external alerts when the BMS detects safety risks such as over-temperature, overcharge, or over-discharge.
- Battery Parallel Function (Optional): Supports parallel connection of battery packs, requiring synchronous use with parallel modules and disabling 'charging current limiting' in the APP.
- Emergency Switch: A standard function that, when activated via the APP, allows the BMS to continue charging and discharging for 30 minutes even if protection thresholds are met, providing an emergency operational window.
- Intelligent Sleep: A standard function that puts the BMS into a low-power standby mode (if charge/discharge current is less than 1A for 26 consecutive hours) to conserve battery energy. It can be reactivated by a button press or by connecting a charger.
- Communication Function (Optional): Supports optional CAN and RS485 communication. Users can configure the address and protocol via the APP.


7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your JIKONG JK Smart BMS. Keep the unit clean and free from dust and moisture. Periodically check all wiring connections for tightness and corrosion. Ensure the battery pack is in good condition and individual cells are balanced. If any issues arise, consult the troubleshooting section or the detailed PDF manual.
8. Troubleshooting
This section provides guidance for common issues you might encounter with your JIKONG JK Smart BMS.
8.1 Protection Triggered (Overvoltage, Undervoltage, Overcurrent, Overtemperature, Low Temperature)
If any of the protection functions are triggered, the BMS will interrupt the circuit to protect the battery. Check the APP for specific alarm messages. Once the condition that triggered the protection is resolved (e.g., voltage returns to normal range, current drops, temperature stabilizes), the BMS will typically resume normal operation automatically or after a set recovery time.
8.2 Short Circuit Protection Triggered
If short circuit protection is triggered, especially during initial connection of a charger or load:
- Charging Short Circuit: If triggered when connecting a charger, it might be due to a high peak current from the charger. You can increase the 'short circuit protection delay' parameter in the APP. The BMS will resume charging after the protection recovery time.
- Discharge Short Circuit: If triggered when connecting a load, it might be due to a large instantaneous current from loads with high capacitance. You can increase the 'short circuit protection delay' parameter in the APP. The BMS will resume discharging after the protection recovery time.
Always ensure external wiring is correct and free from actual short circuits before adjusting parameters.
8.3 BMS Not Activating
If the BMS does not power on after installation, ensure:
- All balance cables and main power cables (P- and B-) are correctly and securely connected.
- The BMS is properly fixed to the battery pack.
- A charger with a voltage 2V higher than the battery voltage is connected to activate the BMS.
- If using optional key switch or display, ensure they are correctly connected and the activation button is pressed.
9. User Tips
- Balancing Current: For optimal battery health, it is recommended that the active balancing current does not exceed 0.2C of your battery's capacity (where C is the battery capacity in Ah).
- Heating Function in Cold Climates: If operating in extremely cold environments, utilize the optional heating function to protect battery cells and maintain performance.
- Secondary Temperature Protection: When using the heating function, consider adding a normally closed temperature control switch (e.g., 45°C to 65°C) in series with the heating circuit as a secondary safety measure to prevent thermal runaway.
10. Support and Resources
For further detailed information, including comprehensive parameter settings and advanced troubleshooting, please refer to the official user manual PDF:
Manufacturer: Chengdu Jikong Technology Co.LTD
For JIKONG BMS exclusive accessories, please visit the official store: JIKONG BMS Flagship Store