1. Product Overview
The JIKONG JK-B2A24S20P is an intelligent active balanced power management system (BMS) designed for large capacity series lithium battery packs. It supports 7S-24S series batteries, including Li-ion, LiFePo4, and LTO battery types. This BMS features high-precision voltage and current acquisition, active balancing, and comprehensive protection functions to ensure battery consistency, extend battery life, and improve overall performance.
The system includes a mobile APP (for Android, iOS, and HarmonyOS) and PC software for monitoring battery status, modifying parameters, and controlling charge/discharge switches via Bluetooth. It also supports optional communication interfaces like CAN and RS485, and features a heating function for low-temperature environments.

Key Features:
- Active Balancing: Achieves 1A-2A continuous balance current through energy transfer, ensuring cell consistency.
- Wide Battery Compatibility: Supports 7S-24S configurations for Li-ion, LiFePo4, and LTO batteries.
- Smart Monitoring: Mobile APP (Android, iOS, HarmonyOS) and PC software for real-time data and parameter adjustment via Bluetooth.
- Comprehensive Protection: Includes overcharge, overdischarge, overcurrent, short circuit, overtemperature, and low-temperature protection.
- Rich Interfaces: Features CAN, RS485, Bluetooth, NTC, Soft Switch, SOC Indicator, Key Switch, Active Equalizer, GPS, and display interfaces.
- Heating Function (Optional): Prevents performance degradation in low-temperature conditions.
- Durable Design: Fully enclosed aluminum alloy shell for superior heat dissipation, dustproof, waterproof, anti-voltage, and anti-vibration properties.
Application Scenarios:
The JIKONG BMS is suitable for a wide range of applications, including:
- E-bikes, Electric Tricycles, Low Speed Quads
- Forklifts, Cleaning Cars, Tourist Cars
- Industrial Drones, Scooters
- RV Energy Storage, Energy Storage Cabinets, Power Banks, Power Tools

2. Setup and Installation
2.1. Packing List
Before installation, please verify that all components are present:
- BMS x 1
- Switch x 1 (50cm long)
- NTC (Temperature Sensor) x 1 (40cm long)
- Sampling line B x 1 (70cm long)
- Sampling line A x 1 (70cm long)

2.2. Wiring Instructions
The JK-BxAxxS-15P/20P series protection board is suitable for 7-24 series lithium battery packs. Wiring methods vary depending on the number of cells. Always ensure all cables are connected correctly before powering on the BMS.
- Connect all sampling cables to the battery cells.
- Insert the sampling cable into the BMS.
- Connect the B-line (total negative electrode) and P-line (total positive electrode) to the battery.
- For models with heating function, connect the heating wire and heater element as shown in the diagram.
- Ensure all connections are secure and correct to prevent abnormal operation or damage.

2.3. APP Installation
The mobile APP for JIKONG BMS supports Android, iOS, and HarmonyOS. To install the APP:
- Scan the QR code provided on the BMS panel or in the manual to download the official APP.
- For Android devices, Android Version 7 or higher is required.

2.4. Device Activation
Before powering on the protection board, double-check that the balance cables are properly connected and that the P- and B- lines are correctly wired. Ensure the protection board is securely fixed to the battery pack.
The BMS does not have a power-on control switch. It is designed for charging activation mode, meaning the charger voltage must be 2V higher than the battery voltage to activate it. After battery assembly, connect the charger to power on the BMS.
Alternatively, if you have a display screen and button accessory, insert the cable into the display interface and press the button to activate the BMS.
3. Operating Instructions
3.1. Active Equalization
The BMS uses active equalization technology to transfer energy from higher voltage cells to lower voltage cells, maintaining voltage balance. The default balance current is 1A/2A. It is recommended that the balance current does not exceed 0.2C of the battery capacity.
You can set the balance trigger voltage difference (mV) in the APP's parameter settings. When the voltage difference between any two battery strings exceeds the set value, balancing will automatically activate. It will turn off when the difference falls below the set value. If active balancing is not required, it can be disabled in the BMS control page of the APP.

3.2. APP and Display Interface
The BMS provides a mobile APP and PC software for comprehensive monitoring and control. You can view battery working status, modify parameters, and control charge/discharge switches. The BMS also has reserved interfaces for optional GPS modules and external display screens.
External display options include 2.5-inch, 3.2-inch, and 4.3-inch touch screens, which provide real-time information such as voltage, current, temperature, and cell count.


3.3. Heating Function (Optional)
For BMS models with the heating function, a resistance heater or heating film can be used to warm the battery in low-temperature conditions, preventing reduced activity. The designed heating current is 10A. This function can be controlled via the APP. It is recommended to install a temperature control switch (45°C to 65°C) in series with the heating circuit as a secondary protection.3.4. Alarm Function (Optional)
The optional alarm function provides external alerts when the BMS detects safety risks such as overtemperature, overcharge, or overdischarge.
3.5. Battery Parallel Function (Optional)
For energy storage battery packs, the BMS supports an optional parallel function. This requires the use of parallel modules and disabling the "charging current limiting" function in the APP.
3.6. ACC Detection Function (Optional)
The optional ACC detection function enables discharge. This can be achieved by applying a voltage between 20V-100V to ACC+ and ACC-, or by directly short-circuiting them. A charger detection function is also reserved for enabling charging.
3.7. Intelligent Sleep
The BMS features an intelligent sleep function to reduce its own energy consumption when in standby (charging/discharging current less than 1A for 26 consecutive hours). This function can be enabled or disabled via the APP. The BMS can be reactivated by pressing a button (if equipped) or by connecting a charger.
3.8. Communication Function (Optional)
The BMS supports optional CAN and RS485 communication functions. Users can select between CAN or RS485 for multiplexed ports in the APP and configure the BMS address and communication protocol as needed. Refer to the JIKONG Protection Board communication protocol document for specific details.
4. Maintenance and Protection
The JIKONG BMS is equipped with various protection mechanisms to safeguard your battery pack. Proper configuration of these parameters via the APP is crucial for optimal performance and safety.
4.1. Overcharge Protection and Recovery
The BMS provides standard overcharge protection. Users can set the single overcharge protection voltage and recovery voltage in the APP. If any cell's voltage exceeds the set protection voltage during charging, the BMS will stop charging. Charging resumes when all cell voltages fall below the recovery voltage.
4.2. Overdischarge Protection and Recovery
Standard overdischarge protection is included. Set the battery undervoltage protection voltage, recovery voltage, and automatic shutdown voltage in the APP. If any cell's voltage drops below the protection voltage during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the recovery voltage. If any cell's voltage drops below the automatic shutdown voltage, the BMS will automatically shut down.
4.3. Overcurrent Protection and Recovery (Charge/Discharge)
The BMS features standard charge and discharge overcurrent protection. Configure the continuous charge/discharge current, overcurrent delay, and overcurrent release time in the APP. If the current exceeds the set value for the specified delay, the BMS will trigger protection and stop the operation. The operation resumes after the overcurrent release time. Note that the maximum continuous discharge current should not exceed the nominal current (150A/200A for respective models).
4.4. Overtemperature Protection and Recovery
Standard overtemperature protection for both charging and discharging is provided. Set the protection and recovery temperatures in the APP. If the BMS detects a temperature above the set protection value, it will stop the operation. The operation resumes when the temperature falls below the recovery value.
4.5. Low Temperature Protection and Recovery
Standard low-temperature protection for charging is included. Set the protection and recovery temperatures in the APP. If the BMS detects a temperature below the set protection value, it will stop charging. Charging resumes when the temperature rises above the recovery value. For extremely cold environments, using the optional heating function is recommended.
4.6. Short Circuit Protection and Recovery
The BMS includes standard short circuit protection. While no current setting is required, you can adjust the short circuit protection delay (in microseconds) and recovery time (in seconds) in the APP. If a short circuit occurs during initial charging or discharge, increasing the delay time may resolve issues caused by instantaneous peak currents from the charger or large load capacitances.
5. Troubleshooting
5.1. Emergency Switch
The BMS is equipped with an emergency switch function. In case of critical issues like over-temperature, over-discharge, over-charge, or cell string drops during normal use, activating the emergency switch via the APP will enable charge and discharge for 30 minutes. This provides a temporary operational window, even if a single cell voltage reaches the automatic shutdown threshold, to prevent immediate system failure in critical situations.5.2. Common Issues and Solutions
- BMS not powering on: Ensure all wiring (sampling lines, B-, P-) is correct and secure. Verify that the activation method (charging or button press) has been performed.
- Protection triggers frequently: Check the parameter settings in the APP for overvoltage, undervoltage, overcurrent, and temperature thresholds. Adjust them according to your battery type and application requirements. For short circuits, consider increasing the protection delay.
- Balancing not working: Ensure active equalization is enabled in the APP and that the balance trigger differential pressure is set appropriately. Check for significant voltage differences between cells.
- Communication issues (Bluetooth/CAN/RS485): Verify that the correct communication module is installed (if optional) and enabled in the APP. Ensure proper wiring for CAN/RS485. For Bluetooth, ensure the indicator light is steady when connected.
- Inaccurate readings: Perform voltage and current calibration in the APP if readings appear incorrect.
6. Specifications
6.1. General Parameters
| Attribute | Value |
|---|---|
| Brand Name | JIKONG |
| Model | JK-B2A24S20P |
| Type | LI-ION Battery BMS (Active Balanced BMS) |
| Battery Series Supported | 7S-24S |
| Charging Current | 200A |
| Active Balancing Current | 1A-2A |
| Charge and Discharge Port | Common Port BMS |
| Support System | Android or iOS (HarmonyOS) |
| Communication | RS485/Bluetooth (Optional CAN/GPS) |
| Temperature Sensor | Yes |
| Certifications | CE, FCC, RoHS |
6.2. Detailed Parameters (200A Protection Board)
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <800 | mW |
| Operating Temperature | -30 to 70 | °C |
| Maximum Number of Collection Strings | 24 | Strings |
| Maximum Balancing Current | 2 | A |
| Maximum Charging Current | 200 | A |
| Maximum Discharge Current | 200 | A |
| Maximum Instantaneous Current | 400 | A |
| Maximum Internal Loop Resistance | 0.275 | mΩ |
| Protective Plate Size (L×W×H) | 162×102×20.4 | mm |
| Finished Weight | 560 | g |

6.3. Default Parameters (Example for LiFePo4)
| Parameter | LiFePo4 Default | Unit |
|---|---|---|
| Balancing Initial Voltage | 3 | V |
| Maximum Balancing Current | 2 | A |
| Unit Overcharge Voltage | 3.6 | V |
| Single Overcharge Protection Recovery | 3.55 | V |
| Monomer Undervoltage Protection | 2.6 | V |
| Single Undervoltage Protection Recovery | 2.65 | V |
| Automatic Shutdown Voltage | 2.5 | V |
| SOC-0% Voltage | 2.6 | V |
| SOC-100% Voltage | 3.5 | V |
| Trigger Balancing Differential Pressure | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | S |
| Charging Overcurrent Protection Release Time | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | S |
| Short-circuit Protection Delay | 5 | μS |
| Short Circuit Protection Release Time | 30 | S |
| Charging Overtemperature Protection | 70 | °C |
| Charging Overtemperature Recovery | 60 | °C |
| Discharge Overtemperature Protection | 70 | °C |
| Discharge Overtemperature Recovery | 60 | °C |
| Charging Low Temperature Protection | -20 | °C |
| Charging Low Temperature Recovery | -10 | °C |
| MOS Overtemperature Protection | 100 | °C |
| MOS Overtemperature Recovery | 80 | °C |
7. Warranty and Support
JIKONG Technology Co., Ltd. is committed to providing high-quality products and support. For detailed warranty information, please refer to the full user manual PDF.
A comprehensive user manual (PDF) is available for download. You can access it by scanning the QR code on the BMS panel or by visiting the official JIKONG website. This PDF contains in-depth information on product specifications, detailed wiring diagrams, APP operation, and communication protocols (CAN/RS485).
Reference: JIKONG Lithium Battery Active Balance Protection Board User Manual (PDF)
For personalized customization needs regarding structure, hardware (e.g., temperature control, power display board, soft switch), or software (e.g., APP, host computer), please contact JIKONG customer service. JIKONG Technology invests significantly in R&D and has a strong development team to meet various customization requirements.

8. User Tips
- Initial Setup: Always perform a thorough check of all wiring connections before applying power to the BMS to prevent damage.
- APP Usage: Regularly check the battery status via the mobile APP to monitor cell voltages, temperatures, and overall health.
- Parameter Tuning: Adjust protection parameters (voltages, currents, temperatures, delays) in the APP to match your specific battery chemistry and application requirements. Refer to the default parameters as a starting point.
- Cold Weather: If operating in cold environments, consider using a BMS model with the heating function to maintain optimal battery performance and longevity.
- Firmware Updates: Keep an eye on official JIKONG channels for any firmware updates that might improve performance or add new features.