1. Introduction
The JIKONG Inverter BMS (Battery Management System) is a sophisticated management system designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge/over-discharge/over-temperature protection, coulomb metering, Bluetooth communication, and PC host monitoring capabilities. This BMS is suitable for various battery types including lithium iron phosphate, ternary lithium, and lithium titanate batteries.
The protection board utilizes energy transfer active balancing technology, ensuring maximum battery consistency, improving battery range, and extending battery life. It supports a mobile APP for Android and iOS, allowing users to monitor battery status, modify parameters, and control charge/discharge switches via Bluetooth. Its compact size, ease of operation, and comprehensive functions make it ideal for high-power energy storage, base station backup power, and solar power station battery packs.
This manual provides detailed instructions for the installation, operation, and maintenance of your JIKONG Inverter BMS.
2. Safety Information
Please read all instructions carefully before installation and operation. Improper installation or use can lead to serious damage to the BMS, battery pack, or other connected equipment, and may pose a safety risk.
- Installation should be performed by qualified personnel.
- Ensure all connections are correct and secure before powering on the system.
- Do not attempt to modify or repair the BMS unless explicitly instructed.
- Always follow local regulations and safety standards for battery systems.
3. Package Contents
Verify that all items listed below are included in your package. If any items are missing or damaged, please contact customer support.

- BMS x1
- Interface board x1
- Adapter cable B x1 (long 30cm)
- Adapter cable A x1 (long 30cm)
- R545 Network cable x1 (long 40cm)
- Sampling line A x2 (long 90cm)
- Sampling line B x1 (long 90cm)
- Sampling line C x1 (long 90cm)
- Switch x1 (long 50cm)
- Heating Adapter cable x1 (long 15cm)
- Adapter cable C x1 (long 30cm)
- Adapter x1
- Sampling line
Video 1: Product unboxing and components overview.
4. Specifications
The JIKONG Inverter BMS is available in several models with varying current capacities and features. Below are the general and default parameters for the V19 version.
4.1. General Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-70 | V |
| Standby Power Consumption | 12 | mW |
| Operating Power Consumption | 1100 | mW |
| Operating Temperature | -30 to 70 | °C |
| Max. Number of Cell Strings | 16 | S |
| Max. Balancing Current | 1A / 2A | A |
| Max. Charging Current (10P/15P/20P) | 100A / 150A / 200A | A |
| Max. Discharge Current (10P/15P/20P) | 100A / 150A / 200A | A |
| Max. Instantaneous Current (10P/15P/20P) | 200A / 300A / 400A | A |
| Max. Internal Loop Resistance (10P/15P/20P) | 1Ω / 0.45mΩ / 0.35mΩ | mΩ |
| Protection Board Size | 300x100x24 | mm |
| Finished Weight | 1000 | g |
4.2. Default Parameters (V19.0.1)
The following table outlines the default parameters for different battery chemistries. These can be adjusted via the mobile APP.
| Parameter | Li-Ion (Ternary) | LiFePO4 | LTO | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Max. Balancing Current | 1A / 2A | 1A / 2A | 1A / 2A | A |
| Single Cell Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.17 | 3.54 | 2.64 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 3 | 3 | 3 | S |
| Charging Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 5 | 5 | 5 | µS |
| Short Circuit Protection Release Time | 30 | 30 | 30 | S |
| Charging Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Charging Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery Temperature | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection Temperature | -20 | -20 | -20 | °C |
| Charging Low Temperature Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection Temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature Recovery Temperature | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
5. Setup & Installation
The JIKONG Inverter BMS is suitable for 7-16 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack. Always ensure correct polarity and secure connections.
5.1. Wiring Instructions
Follow these steps for proper installation and wiring:
- First, weld the B-, P-, B+, and P+ terminals.
- Then, insert the battery sampling cable in order from low to high.
- Activate the device after power on. Ensure all cables are correctly connected, then add the load and charger.
- When disassembling, first disconnect the charger and load, unplug the battery sampling cable in order from high to low, and finally unplug B+, P+, B-, P-.

5.2. Interface Board Functions
The interface board is factory-standard and provides LED indicators, a reset switch, DIP switches, dry contacts, and communication functions. The LED indicators help determine the BMS working status and remaining battery power. The reset button can be pressed to reset the BMS. DIP switches are used to set the address for parallel use (0-15). Dry contacts control external devices like alarms and fans. CAN and RS485-1 are used for communication with inverters, while RS485-2 is for parallel battery packs and PC communication.

5.3. Device Activation
Before starting the protection board, ensure the balance cable is properly connected and that P- and B- are correctly connected. Verify the protection board is securely fixed to the battery core. Once confirmed, power on the protection board.
The BMS is designed for charging activation mode (charger voltage 2V higher than battery voltage). After battery assembly, connect the charger to activate the protection board. Alternatively, the BMS can be activated via a button or the display screen by inserting the cable into the display interface and pressing the button.
6. Operating Instructions
6.1. Mobile APP Installation
To obtain the mobile APP for your JIKONG BMS, scan the QR code below. Android Version 7 or higher is required.
The mobile APP allows you to monitor battery status, modify working parameters, and control charge/discharge switches via Bluetooth.
6.2. Display Interface
The protection board includes a display interface. You can connect an optional JIKONG LCD display (3.2-inch or 4.3-inch) to view real-time battery information such as voltage, current, temperature, and State of Charge (SOC).

The V19 version of the liquid crystal touch screen offers enhanced functions including parallel monitoring, touch settings for parameter adjustment, real-time status display, and an intuitive interface.
6.3. Active Equalization
The BMS employs active equalization to transfer energy from high-voltage cells to low-voltage cells, ensuring cell consistency. Before using this function, set basic battery parameters (battery type, number of cells, capacity, trigger differential pressure, voltage/current calibration) in the APP. The balance current is typically 1A or 2A, adjustable based on battery capacity (recommended not to exceed 0.2C). If not needed, disable balancing in the APP.
6.4. Heating Function
The BMS includes a heating function for low-temperature conditions. It uses a resistance heater or heating film to warm the battery, preventing reduced activity. The heating current is 10A. Control this function via the BMS control page in the APP. It is recommended to install a temperature control switch (45-65°C normally closed) in series with the heating circuit as a secondary safety measure.
6.5. Dry Contact Function
Two dry contacts are provided to control external devices like alarms or fans. When the BMS detects an over-temperature, overcharge, or over-discharge state, the alarm interface can activate a buzzer or fan. You can select two trigger conditions in the APP.
6.6. Communication Function (CAN/RS485)
The BMS supports CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate inverter protocol in the APP. There are two RS485 interfaces: RS485-1 for inverter communication and RS485-2 for parallel battery pack communication and PC connection. RS485-2 has two ports for parallel connection and communication with a host PC at a default baud rate of 115200. Communication addresses (0-15) can be set via DIP switches.

6.7. Parallel Function
The parallel function allows simultaneous monitoring of multiple BMS units by a host computer via the RS485 bus. Each BMS needs a unique address (0-15), set via DIP switches. BMS with address 0 acts as the host, and 1-15 as slaves. The host PC connects to the host BMS via a USB to RS485 serial port cable, and BMS units are interconnected with RJ45 Ethernet cables.


7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your JIKONG Inverter BMS. This includes monitoring battery health and ensuring proper environmental conditions.
7.1. Protection Features
The BMS is equipped with various protection mechanisms to safeguard your battery pack:
- Overcharge Protection: Prevents battery overcharging by shutting off charging when any cell exceeds the set overcharge voltage. Charging resumes when all cells are below the recovery voltage.
- Over-discharge Protection: Prevents battery over-discharging by shutting off discharge when any cell falls below the set undervoltage protection value. Discharge resumes when cells are charged above the recovery voltage. The BMS will automatically shut down if any cell voltage drops below the automatic shutdown voltage.
- Overcurrent Protection (Charge/Discharge): Monitors charging and discharging currents. If current exceeds the set continuous limit for a specified delay, charging/discharging is stopped. It resumes after the release time.
- Overtemperature Protection (Charge/Discharge): Stops charging/discharging if battery temperature exceeds the set overtemperature limit. Operation resumes when temperature falls below the recovery threshold.
- Low Temperature Protection (Charge): Stops charging if battery temperature falls below the set low temperature limit. Charging resumes when temperature rises above the recovery threshold. The heating function is recommended for cold environments.
- Short Circuit Protection: Automatically protects against short circuits. The delay and recovery times can be adjusted via the APP. If a short circuit occurs during initial charging or loading, increasing the delay time may resolve it, especially if caused by high peak currents from the charger or load capacitance.
- Intelligent Sleep: The BMS can enter an intelligent sleep mode (configurable via APP) if charging/discharging current is below 1A for 26 consecutive hours, reducing self-consumption. It can be reactivated by button or charger.
- Charge Current Limiting: Limits charging current to approximately 10A if an overcurrent condition occurs during charging, protecting the battery.
7.2. Emergency Switch
The emergency switch function (enabled via APP) allows the BMS to continue charging and discharging for 30 minutes even if issues like over-temperature, over-discharge, overcharge, or cell string drops occur. This provides a temporary operational window. The BMS will continue to operate until the 30-minute period ends, even if a single cell reaches the automatic shutdown voltage, to prevent immediate system failure in critical situations.
8. Troubleshooting
This section addresses common issues and their potential solutions.
- BMS not activating: Ensure all wiring (P-, B-, P+, B+) is correct and secure. Verify the balance cable is properly connected. Try activating by connecting the charger (voltage 2V higher than battery) or by pressing the button if a display is connected.
- Balancing not working: Check APP settings for active equalization. Ensure battery parameters (type, cell count) are correctly configured. Verify the trigger differential pressure setting.
- Overcurrent/Overvoltage/Overtemperature protection triggering frequently: Review your battery pack's specifications and compare them with the BMS parameter settings in the APP. Adjust continuous current limits, temperature thresholds, or voltage limits as appropriate for your system. Ensure adequate cooling for the BMS and battery.
- Short circuit protection triggering: If this occurs during initial connection of a charger or load, try increasing the short circuit protection delay time in the APP. Ensure there are no actual wiring shorts.
- Communication issues (APP/PC): Verify Bluetooth connection for APP. For PC/RS485/CAN, check physical connections, communication addresses (DIP switches), and baud rates. Ensure the correct protocol is selected in the APP for inverter communication.
- Display not showing data: Ensure the display cable is securely connected to the interface board. Check power supply to the display.
9. User Tips
- Firmware Updates: The V19 firmware offers improved SOC/SOH estimation, smarter thermal management, comprehensive fault diagnosis, and OTA remote upgrade support. Regularly check for and apply firmware updates for optimal performance and security.
- Parameter Customization: Take advantage of the mobile APP to fine-tune parameters like balancing current, protection thresholds, and communication settings to match your specific battery chemistry and application needs.
- Wiring Quality: Use high-quality connecting wires and ensure all connections are robust to prevent issues like voltage drops or intermittent communication.
- Temperature Monitoring: Pay attention to temperature readings, especially in extreme conditions. The heating function is crucial for maintaining battery health in cold environments.
- Parallel Systems: When using multiple BMS units in parallel, carefully configure each unit's address using the DIP switches and ensure proper RS485 interconnections for reliable monitoring.
10. Warranty & Support
For detailed warranty information and technical support, please refer to the official documentation provided by Chengdu Jikong Technology Co. LTD. A user manual in PDF format is available for download and contains comprehensive guides and documents.
Reference: User manual (PDF)