HIOS HP-10/HP-20/HP-50/HP-100

Contents

HIOS Digital Torque Meter User Manual

Models: HP-10, HP-20, HP-50, HP-100

Brand: HIOS

1. Introduction

The HIOS Digital Torque Meter is a high-precision instrument designed for accurate measurement and setting of torque for electric screwdrivers and for detecting screwdriver torque. Featuring a digital display, it provides clear and precise readings, ensuring reliable performance in various applications. Its portable and rechargeable design offers convenience and flexibility for on-the-go use.

2. Safety Information

  • General Safety: This product is not suitable for children under 36 months. Keep out of reach of small children.
  • Load Limits: Do not exceed the maximum allowable load specified for your model to prevent damage to the device.
  • Impact: Avoid continuous impact on the measurement sensor.
  • Battery Charging:
    • Charge the device when "LO" or battery icon is displayed on the screen.
    • The charging time is designed to be within six hours.
    • Always keep the power on when charging the battery.
    • Do not detach the rechargeable battery from the main unit.
  • Adapter Use: Use the main unit and detector with the same serial number. Do not leave or store the adapter with its string coiled.

3. Package Contents

Upon opening your package, please verify that all items are present and in good condition:

  • Digital Torque Meter (1 unit)
  • Protective Carrying Case
  • Power Adapter (AC 110V/220V input, DC 9V 400mA output)
  • Hex Key (for adjustments)
  • Measurement Adapters/Accessories
  • Calibration Certificate
  • User Manual
Complete package contents of the HIOS Digital Torque Meter HP-100, including the meter, carrying case, power adapter, accessories, and calibration certificate.
Figure 3.1: Complete Package Contents

4. Product Overview

Familiarize yourself with the main components and controls of your Digital Torque Meter:

Front view of the HIOS Digital Torque Meter HP-100 showing the digital display, power switch, reset button, unit selection, and mode selection (Peak/Track).
Figure 4.1: Front Panel Controls and Display
  • Digital Display: Shows torque readings, battery status, and selected units/modes.
  • POWER ON/OFF Switch: Toggles the device power.
  • RESET Button: Resets the current reading or clears error states.
  • ZERO ADJ Knob: For fine-tuning the zero point of the measurement.
  • UNIT Selection Buttons: Cycles through available torque units (lbf.in, kgf.cm, N.m).
  • MODE Selection Switch: Selects between PEAK and TRACK measurement modes.
  • Measurement Port: Where screwdrivers or other tools are attached for torque testing.
Side view of the HIOS Digital Torque Meter HP-100 showing the clamp mechanism.
Figure 4.2: Side View with Clamp Mechanism
Bottom view of the HIOS Digital Torque Meter HP-100 displaying the serial number and a warning label.
Figure 4.3: Bottom View with Serial Number

5. Specifications

The following table details the specifications for the various HIOS Digital Torque Meter models:

Table detailing specifications for HIOS Digital Torque Meter models HP-10, HP-20, HP-50, and HP-100, including measuring range, precision, sampling rate, power, charging time, usage time, size, and charger details.
Figure 5.1: Model Specifications Table
Attribute HP-10 HP-20 HP-50 HP-100
Measuring Range (lbf.in) 0.05-9.00 0.5-18.0 0.5-45.0 0.5-90.0
Measuring Range (KGf.cm) 0.05-10.00 0.5-20.0 0.5-50.0 0.5-100.0
Measuring Range (N.m) 0.005-1.000 0.05-2.00 0.05-5.00 0.05-10.00
Precision ±0.5%F.S
Sampling Rate 500Hz
Power Supply 3.7V 1800mAh lithium battery
Charging Time >8 hours
Full Power Usage Time 45 hours
Size 120*230*50mm
Charger Input: AC 220V/110V, Output: DC 9V 400mA

Additional Specifications:

  • Name: Digital Torque Meter
  • Voltage: 110V / 220V (optional)
  • Version: The first generation high precision
  • Application: Torque setting of electric screwdriver and detection of screwdriver torque.

6. Setup

  1. Unpacking: Carefully remove the Digital Torque Meter and all accessories from the protective carrying case. Inspect for any signs of damage.
  2. Initial Charge: Before first use, or if the battery indicator shows low power ("LO" or battery icon), connect the provided power adapter to the DC ADAPTOR port on the meter and plug it into an appropriate power outlet (110V or 220V, depending on your model). Ensure the power switch is in the 'ON' position during charging. Charge for at least 8 hours.
  3. Power On: Flip the POWER switch to the 'ON' position. The digital display should illuminate.
  4. Zero Adjustment: Before taking measurements, ensure the display reads zero. If not, use the ZERO ADJ knob to fine-tune the display to zero.
  5. Mounting (Optional): The meter can be used freestanding or clamped to a workbench using the integrated clamp mechanism for stability during testing.
Video 6.1: Product Unboxing and Initial Overview

7. Operating Instructions

  1. Power On: Turn on the device using the POWER switch.
  2. Select Unit: Press the UNIT button(s) to cycle through the desired measurement units: lbf.in, kgf.cm, or N.m.
  3. Select Mode: Use the MODE switch to select between:
    • PEAK Mode: Captures and displays the maximum torque value applied during a measurement.
    • TRACK Mode: Displays real-time torque values as they are applied.
  4. Zero Adjustment: Ensure the display reads zero before each measurement. If necessary, use the ZERO ADJ knob to calibrate.
  5. Attach Tool: Securely attach the screwdriver or torque tool to be tested to the measurement port. Use appropriate adapters if needed.
  6. Apply Torque: Apply torque to the tool. The digital display will show the measurement according to the selected mode.
  7. Reset: After each measurement in PEAK mode, or to clear the display in TRACK mode, press the RESET button.

8. Maintenance

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Battery Care:
    • Always charge the battery with the power on.
    • Do not detach the rechargeable battery from the main unit.
    • For long-term storage, ensure the battery is fully charged and store the adapter uncoiled.
  • Storage: Store the torque meter in its protective carrying case in a dry, cool place, away from direct sunlight and extreme temperatures.
  • Calibration: Regular calibration is recommended to maintain measurement accuracy. Refer to the calibration certificate for details.

9. Troubleshooting

Problem Possible Cause Solution
Device does not power on. Low battery or power switch is off. Charge the battery for at least 8 hours. Ensure the power switch is in the 'ON' position.
Inaccurate readings. Not zeroed correctly, exceeding max load, or device malfunction. Perform zero adjustment before measurement. Ensure applied torque is within the specified range. If issues persist, contact support.
"LO" or battery icon displayed. Low battery. Connect the power adapter and charge the device.

10. User Tips

  • Verify Calibration: Upon receiving your torque meter, always verify the inclusion of a recent calibration certificate to ensure the accuracy of your measurements.
  • Consistent Testing: For best results, ensure accurate readings by testing with various screwdrivers or tools in a consistent manner.
  • Stable Surface: For critical measurements, use the clamp mechanism to secure the meter to a stable workbench to minimize external influences.

11. Warranty and Support

This product comes with a 1-year warranty from the date of purchase. For technical support, warranty claims, or service inquiries, please contact the manufacturer or your local distributor.

Manufacturer Information:

  • Full Name: Hubei Super Purchase Trade Co., Ltd.
  • Address: New residential project at No. 61 Wulantang Road, Hongshan District, Wuhan City, Hubei Province (Dazhou Village urban transformation K5) (Phase I), Building 1, Unit 1, 9th Floor, No. 1, postal code: 430000, China
  • Phone: 86-17771530298
  • Email: 2157346215@qq.com

EU Agent Information:

  • Name: eVatmaster Consulting GmbH
  • Contact: contact@evatmaster.com
  • Address: Raiffeisen Street 2 B11, 63110 Rodgau, Hessen, Germany
General service information including 1-year warranty.
Figure 11.1: Warranty and Service Overview

12. Compliance

This product complies with relevant European safety, health, and environmental protection requirements.

CE, RoHS, and FC compliance marks.

Figure 12.1: Compliance Marks

For the full user manual in PDF format, please refer to the official documentation provided by the seller or manufacturer. A PDF version of the user manual is available at: User Manual (PDF)

© 2023 HIOS. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.