KeepLiNK 24-Port Gigabit Ethernet Switch

Model: KP-9000-24G-AC

User Manual

1. Introduction

The KeepLiNK KP-9000-24G-AC is a 24-Port Gigabit Ethernet Unmanaged Switch designed for reliable, high-speed network connectivity. This plug-and-play device requires no configuration, making it ideal for small-medium businesses, home offices, and entertainment setups. Its fanless design ensures silent operation, and energy-efficient features help reduce power consumption. The switch is housed in a durable metal case, rigorously tested for reliability.

Front view of the KeepLiNK 24-Port Gigabit Switch, highlighting its non-blocking, fanless, and plug & play features.
Front view of the KeepLiNK 24-Port Gigabit Switch, highlighting its non-blocking, fanless, and plug & play features.
Side view of the switch illustrating its compact design and dimensions (270 x 181 x 44 mm).
Side view of the switch illustrating its compact design and dimensions (270 x 181 x 44 mm).

2. Packing List

Please check the contents of your package. If any items are missing or damaged, contact your vendor.

  • KeepLiNK 24-Port Gigabit Ethernet Switch
  • AC power cord (for built-in power supply device)
  • Power adapter (for non-built-in power devices, if applicable)
  • Hanging ears and screws (for rack mounted device, if applicable)
  • User manual (this document)
  • Certificate of conformity

3. Product Overview

3.1 DIP Switch Instructions

The specific DIP switch definitions may vary based on the actual product model. Refer to the tables below for common configurations.

DIP Switch Definition of Non-PoE Switch
DIP Switch Specification Sequence Definition of DIP Switch Description
4 DIP Switch 1 Reserve Reserve
2 Extend 250m long distance transmission (downlink port)
3 Port Isolation Port isolation
4 Storm Control Suppress broadcast data
DIP Switch Definition of PoE Switch
DIP Switch Specification Sequence Definition of DIP Switch Description
4 DIP Switch 1 AI POE Auto detect and reboot unresponsive PoE devices for recovery
2 Extend 250m long distance transmission (PoE port)
3 Port Isolation Port isolation
4 Storm Control Suppress broadcast data
3 DIP Switch 1 Extend 250m long distance transmission (PoE port)
2 Standard Normal mode
3 Port Isolation Port isolation
2 DIP Switch 1 Extend 250m long distance transmission (PoE port)
2 AI PoE/Reserve AI PoE/Reserve
DIP Switch Definition of Lite Management Switches
DIP Switch Specification Sequence Definition of DIP Switch Description
3 DIP Switch 1 Web-managed WEB management
2 Standard Standard mode
3 Port Control Port isolation

3.2 Indicator Lights

The indicator lights provide visual feedback on the switch's status and port activity.

Sign Definition Status Description
PWR/P Power indicator light Green light always on/off Power is connected/not connected
AI POE AI light Green light on/off AI PoE started/not started
SYS/NMS/S/N System light Green light on/off System working/system not started
100Mbps copper port Connection status indicator light Left light Speed Yellow light always on 100M speed
Yellow light off 10M speed
Right light Link/act Green light always on Port connected
Green light off Port not connected
Green light blink The port is connected and there is data transmission and reception
1000Mbps copper port Connection status indicator light Left light Speed Yellow light always on 1000M speed
Yellow light off 10/100M speed
Right light Link/act Green light always on Port connected
Green light off Port not connected
Light blink The port is connected and there is data transmission and reception
2.5G copper port Connection status indicator light Left light Speed Yellow light on 2.5G speed
Yellow light off or green light always on 10/100/1000M speed
Right light Link/act Green light always on Port connected or 10/100/1000M speed
Green light off Port not connected
Light blink The port is connected and there is data transmission and reception
10G copper port Connection status indicator light Left light Speed Yellow light on 10G speed
Green light on 5G speed
Light blink Data transmission and reception
Yellow light on 2.5G rate
Green light on 1G rate
Right light Speed Light off Port not connected
Light blink The port is connected and there is data transmission and reception
10G downlink fiber port Connection status indicator light Link/act Yellow light always on 10G speed
Green light always on 1G rate
Light off Port not connected
Light blink The port is connected and there is data transmission and reception
Optical port connection status indicator light Link/act Green light on Port connected
Green light off Port not connected

4. Setup and Installation

4.1 Installation Precautions

4.1.1 Precautions for Device Connection and Installation
  • Network Cable:
    • For 100Mbps RJ45 interfaces, use Cat5 or above Ethernet cable.
    • For 1000Mbps/2.5GE/5GE RJ45 interfaces, use Cat5e or above Ethernet cables.
    • For 10GE speed RJ45 interfaces, use Cat6a or above Ethernet cables.
  • Fiber Optic Cable:
    • Fiber optics and connectors must be used with optical modules.
    • The bending radius of the optical fiber should not be less than 40mm.
4.1.2 Safety Precautions for Equipment Installation
  • Always keep the power off during installation.
  • Ensure the power supply voltage matches the voltage indicated on the switch.
  • Before powering on, ensure the power circuit is not overloaded.
  • To avoid electric shock, do not open the casing of the switch while it is in operation.
4.1.3 Precautions for Equipment Installation Environment
  • Maintain appropriate temperature and humidity to ensure long-term stable operation.
  • Regularly remove dust, maintain clean indoor air, ensure good grounding, and smooth transfer of static electricity to prevent static electricity effects.
  • Keep the switch away from high-frequency, high-power, and high current equipment to reduce electromagnetic interference.
  • Ensure proper grounding and reasonable wiring for lightning protection. Use signal lightning protectors when wiring outdoors.

4.2 Switch Installation Methods

The switch supports desktop, rack, and wall-mounted installation. Choose the method that best suits your environment.

4.2.1 Rack Mounted Installation

Prepare hanging ears and screws. Secure the hanging ears to both ends of the device. Push the device parallel to the tray into the cabinet and secure it with cabinet screws.

Diagram illustrating the rack mount installation process with hanging ears and screws.
Diagram illustrating the rack mount installation process with hanging ears and screws.
4.2.2 Desktop Switch Installation

Place the switch on a flat and secure desktop. Ensure sufficient ventilation and heat dissipation space around the device. Do not place heavy objects on the switch.

4.2.3 Wall Mounting Installation

Fix screws on the wall according to the position of the wall mounting holes on the device. The distance between the nuts and the wall should be approximately 3mm ± 0.5mm. Align the wall mounting holes on the device with the screws for installation and fixation.

4.3 Console Port Management

For advanced management, connect a console port cable from the switch to your PC. Open terminal simulation software, establish a connection, select the serial port, and configure communication parameters:

  • Transmission rate: 115200
  • Data bit: 8
  • Check digit: None
  • Stop bit: 1
  • Flow control method: None

4.4 WEB Management

This feature is applicable to network management products. To access the web management interface:

  1. Connect the device to a PC and ensure initialization is complete.
  2. Configure the PC's IP address to be in the same network segment as the switch's default IP address.
  3. Open a PC browser and input "http://192.168.1.168". Press Enter to access the login interface.
  4. Enter the default username "admin" and password "admin" to log in.
Screenshot of the web management login interface for the switch.
Screenshot of the web management login interface for the switch.

5. Operating Instructions

5.1 PoE Powered Function (if applicable)

This feature is applicable to PoE switches. Standard PoE power supply includes protocol detection, power pin sequence detection, power output, anomaly protection, and link anomaly monitoring.

  • PoE Power Supply Protocols: IEEE802.3af (15.4W), IEEE802.3at (30W), and IEEE802.3bt (90W).
  • Standard PoE Power Supply Pin Sequence: 1,2+/3,6-.
  • Standard PoE++ Power Supply Pin Sequence: 1,2,4,5+/3,6,7,8-.

Standard PoE switches automatically detect and provide power to standard PoE devices. Non-PoE devices will not be powered on and will only transmit data.

Diagram illustrating the power and data pins for standard PoE power supply.
Diagram illustrating the power and data pins for standard PoE power supply.
Video showcasing the features and design of the KeepLiNK 24-Port Gigabit Ethernet Switch.

6. Maintenance

Proper maintenance ensures the longevity and optimal performance of your KeepLiNK switch.

  • Environmental Control: Maintain a stable temperature and humidity in the operating environment to prevent material degradation and corrosion.
  • Cleanliness: Regularly remove dust from the device and ensure clean indoor air to prevent static electricity buildup and maintain proper airflow.
  • Grounding: Confirm that the equipment is properly grounded to ensure smooth transfer of static electricity and reduce the risk of damage.
  • Electromagnetic Interference: Keep the switch away from sources of strong electromagnetic interference, such as high-frequency, high-power, and high-current equipment. Ensure the power supply system has anti-grid interference measures.
  • Lightning Protection: Ensure proper grounding for the rack and power sockets. Use signal lightning protectors for outdoor wiring to prevent damage from lightning strikes.

7. Troubleshooting

If you encounter issues with your KeepLiNK switch, consider the following basic troubleshooting steps:

  • No Power: Check the power cable connection and ensure the power outlet is functional. Verify the PWR/P indicator light is on.
  • No Link/Activity: Ensure Ethernet cables are securely connected to both the switch and the connected device. Check the Link/Act indicator lights for the respective ports. If the light is off, try a different cable or port.
  • Slow Connection: Verify that the connected devices support Gigabit speeds. Check the speed indicator lights (Left light Speed) to confirm the link speed (e.g., Yellow for 100M, Yellow for 1000M). Ensure you are using appropriate cable types (Cat5e or Cat6a for Gigabit speeds).
  • Network Instability: Check for any sources of electromagnetic interference nearby. Ensure the switch is properly grounded. If using PoE, ensure connected devices are standard PoE compatible.
  • Web Management Access Issues: Confirm your PC's IP address is in the same network segment as the switch. Double-check the IP address entered in the browser and the default login credentials (admin/admin).

For persistent issues, refer to the full user manual PDF or contact technical support.

8. Specifications

The following table details the technical specifications of the KeepLiNK KP-9000-24G-AC switch.

Detailed specifications table for the KeepLiNK 24-Port Gigabit Switch.
Detailed specifications table for the KeepLiNK 24-Port Gigabit Switch.
Attribute Value
Brand NamekeepLiNK
Model NumberKP-9000-24G-AC
Switch TypeGigabit Switch
Number of Interfaces24
Transmission Rate10/100/1000Mbps
Switch Capacity48 Gbps
Packet forwarding rate35.71Mpps
Communication ModeFull-Duplex & Half-Duplex
VLAN SupportYes
FunctionVLAN Support
MAC address table2 k
Buffer2M
Forwarding delay<10us
MDX/MDIXyes
Jumbo Frame13K bytes
Operating temperature-10℃~55℃
Storage temperature-40℃~70℃
Thermal methodsFan-less
Dimension270 x 181 x 44 mm
Form FactorDesktop or wall mount
Weight1.14 kg
CertificationCE, FCC, RoHS
OriginMainland China

9. User Tips

Based on user experiences, here are some tips for getting the most out of your KeepLiNK switch:

  • Performance: Users report that the switch delivers excellent performance, often exceeding expectations and providing faster speeds compared to older models.
  • Ease of Use: The plug-and-play nature of the switch is highly appreciated, making setup straightforward without complex configurations.
  • Build Quality: The robust metal casing contributes to the switch's durability and reliability, ensuring it can withstand various environments.
  • Installation Flexibility: The option for desktop, wall, or rack mounting provides versatility to integrate the switch seamlessly into different setups.
  • Value: Many users find the switch to be a great purchase, offering good value for its performance and features.

10. Warranty and Support

10.1 After-sales Service Letter of Commitment

Return/Replacement: Within seven days from the date of sale, if the whole device fails, you can choose to repair, replace, or return it.

Warranty Period: If a performance failure occurs within seven days to one year from the date of sale (based on the purchase invoice and proof of three guarantees), the whole machine can be repaired or replaced.

Beyond the one-year hardware warranty period, the cost of replacing hardware will be borne by the user.

10.2 Circumstances Without Warranty

The warranty does not cover equipment failure or damage under the following circumstances:

  • Accessories supplied by other companies (e.g., power supply, adapter) are covered by their respective manufacturers.
  • The machine and parts have exceeded their warranty period.
  • Equipment failure or damage not caused by repair, alteration, or demolition by our company's personnel.
  • Malfunctions caused by accidental or artificial causes, including improper operation, scratching, handling, moving, knocking, or inputting inappropriate voltage.
  • Failure or damage caused by the use of non-genuine or unpublished software.
  • Failures or losses caused by natural disasters (e.g., earthquakes, fires).

10.3 Additional Documentation

A detailed user manual in PDF format is available for further reference: View User Manual (PDF).

© 2023 KeepLiNK. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.