yieryi PH-W218

Contents

Yieryi PH-W218 WiFi Tuya Smart 8-in-1 Water Quality Tester Instruction Manual

Model: PH-W218

1. Introduction

The Yieryi PH-W218 is an advanced 8-in-1 WiFi Tuya Smart Water Quality Tester designed for continuous online monitoring of various water parameters. This device provides real-time data for pH, ORP, TDS, EC, Salt, S.G (Specific Gravity), Temperature, and CF (Conductivity Factor). It is suitable for a wide range of applications including aquariums, mariculture, drinking water analysis, hydroponics, laboratories, spas, and swimming pools. The tester integrates with the Tuya Smart APP for convenient remote monitoring, data logging, and alert notifications.

2. Package Contents

Please verify that all items are present and in good condition upon unpacking:

  • 1 x Main Monitor Unit
  • 1 x PH Probe
  • 1 x ORP Probe
  • 1 x PPM/EC/Salt/S.G./CF Probe
  • 1 x Temperature Probe
  • 1 x Power Adapter (EU/US/UK/AU plug type, depending on region)
  • 1 x English User Manual
  • 2 x Suction Cups
  • 1 x Clip
  • 1 x 4.0 PH Calibration Powder
  • 1 x 6.86 PH Calibration Powder
  • 1 x 9.18 PH Calibration Powder
  • 1 x ORP Calibration Powder
  • 1 x 1413us/cm/25ml Calibration Solution
  • 1 x 12.88ms/cm/25ml Calibration Solution
Image showing the complete package contents of the Yieryi PH-W218 water quality tester, including the main unit, various probes, power adapter, calibration solutions, and accessories.
Figure 2.1: PH-W218 Package Contents

3. Setup

3.1 Physical Installation

The PH-W218 features a wall-mounted design for easy installation. Use the provided suction cups and clip to securely mount the main monitor unit in a suitable location. Ensure the location is dry and not exposed to water or dampness, as the tester is not waterproof.

Image showing the wall-mounted installation of the Yieryi PH-W218 water quality tester above an aquarium, with probes submerged in water.
Figure 3.1: Wall-mounted installation example
Image showing the hook design on the back of the Yieryi PH-W218 main unit for wall mounting.
Figure 3.2: Hook design for mounting

3.2 Probe Connection

Connect each probe to its corresponding port on the main monitor unit. The probes are labeled for PH, ORP, PPM/EC/Salt/S.G./CF, and Temperature. Ensure connections are secure.

Detailed image of the Yieryi PH-W218 main unit showing the connection points for the PH, ORP, PPM/EC/Salt/S.G./CF, and Temperature probes, along with the power adapter input.
Figure 3.3: Probe Interface and Connections

3.3 Power Connection

Connect the provided power adapter to the main monitor unit and a suitable power outlet. Important: Do not use a mobile phone USB cable to power the device; use only the supplied power adapter.

3.4 Tuya Smart APP & WiFi Connection

  1. Download the "Tuya Smart" APP from your device's app store (compatible with Apple and Android systems).
  2. Register or log in to your Tuya account.
  3. On the PH-W218 main unit, long press the "MODE" key (PPM/EC/SALT/S.G/CF section) to turn WiFi on/off. The WiFi indicator should blink.
  4. In the Tuya Smart APP, follow the on-screen instructions to add a new device. The app should discover the "WiFi smart online 8-in-1" device.
  5. Enter your WiFi network details (SSID and password) when prompted.
  6. Once connected, the device will appear in your app, and you can begin real-time monitoring.
Video 3.1: Step-by-step guide for connecting the Yieryi PH-W218 to the Tuya Smart APP via WiFi.
Image showing a smartphone displaying the Tuya Smart APP interface connected to the water quality tester, with real-time data monitoring.
Figure 3.4: WiFi Connection and Data Transfer via Tuya Smart APP

4. Operation

4.1 Basic Measurement

Once the device is powered on and probes are connected, immerse the electrodes into the water sample you wish to test. The LCD screen on the main unit will display real-time readings for all parameters. The Tuya Smart APP will also show these readings.

Image showing the Yieryi PH-W218 water quality tester with probes submerged in water, displaying various parameters on its LCD screen.
Figure 4.1: 8-in-1 Water Quality Monitoring in action

4.2 Switching Temperature Units (°C/°F)

Short press the "TEMP CAL" key (PH/TEMP section) to switch the temperature display between Celsius (°C) and Fahrenheit (°F).

Image illustrating how to switch between Celsius and Fahrenheit temperature units by short pressing the 'TEMP CAL' button on the device.
Figure 4.2: Temperature Unit Switching

4.3 Switching PPM/EC/SALT/S.G/CF Display

Short press the "MODE" key (PPM/EC/SALT/S.G/CF section) to cycle through the display of PPM, EC, SALT, S.G, and CF parameters.

Image illustrating how to cycle through PPM, EC, SALT, S.G, and CF measurements by short pressing the 'MODE' button on the device.
Figure 4.3: Parameter Mode Switching

4.4 Real-time Monitoring via APP

The Tuya Smart APP provides a comprehensive interface for real-time monitoring. You can view current data, historical data, and set alarm thresholds for various parameters. The app automatically converts language and region settings based on your phone's configuration.

Image showing multiple screenshots of the mobile application interface for the Yieryi PH-W218, displaying real-time data for various water quality parameters like temperature, pH, TDS, and EC.
Figure 4.4: Mobile Application Monitoring Interface
Image showing the real-time pH data detection feature within the Tuya Smart app, including a pH scale and a graph of historical pH values over time.
Figure 4.5: Real-time PH Data Detection
Image showing the real-time SALT measurement feature within the Tuya Smart app, displaying the current salt value and a graph of historical data.
Figure 4.6: Real-time SALT Measurement
Image showing the real-time ORP measurement feature within the Tuya Smart app, displaying the current ORP value, alarm settings, and a graph of historical data.
Figure 4.7: Real-time ORP Measurement
Image showing the real-time S.G. (Specific Gravity) measurement feature within the Tuya Smart app, displaying the current S.G. value and a graph of historical data.
Figure 4.8: Real-time S.G. Measurement
Image showing the real-time CF (Conductivity Factor) measurement feature within the Tuya Smart app, displaying the current CF value, alarm settings, and a graph of historical data, with a background of hydroponic plants.
Figure 4.9: Real-time CF Measurement

4.5 Data Logging and Export

The device logs data continuously, transmitting a set of data every 15 seconds. You can view data curve graphs for daily, weekly, and monthly periods within the app for analysis.

Image showing the real-time pH data detection feature within the Tuya Smart app, including a pH scale and a graph of historical pH values over time.
Figure 4.10: Data Logging and Historical Graphs

To export data:

  1. In the Tuya Smart APP, navigate to the data export section.
  2. Click "Export" and enter your email address.
  3. The data will be sent to your mailbox in an Excel format. You can then download, view, and share the data.
Image showing the process of exporting data from the Tuya Smart app to Excel via email, with steps to click export, enter email, and open the Excel file.
Figure 4.11: Data Export to Excel/Email

4.6 Alarm Settings

You can set high and low alarm thresholds for pH and other parameters within the Tuya Smart APP. The app can provide SMS notifications or pop-up screen prompts when values exceed or fall below these set limits.

5. Calibration

Regular calibration ensures the accuracy of your water quality tester. Use the provided calibration powders and solutions as instructed.

5.1 PH Calibration

The PH-W218 supports 3-point pH calibration. You can choose between two sets of calibration points: 6.86, 4.00, and 9.18, or 7.00, 4.00, and 10.00. The factory default calibration is 6.86, 4.00, and 9.18.

To calibrate pH:

  1. Prepare the pH buffer solutions (e.g., pH 4.01, pH 6.86, pH 9.18).
  2. Long press the "TEMP CAL" key (PH/TEMP section) to enter PH calibration mode.
  3. Follow the on-screen prompts or app instructions to calibrate each point by immersing the PH probe in the respective buffer solution.
Image showing pH buffer powders for calibration: pH 4.01, pH 6.86, and pH 9.18.
Figure 5.1: PH Calibration Powders

5.2 ORP Calibration

ORP calibration points are 265mV and 100mV. Use the provided ORP calibration powder to prepare the solution and follow the calibration procedure as outlined in the app or detailed manual.

5.3 EC Calibration

EC calibration points are 12.88ms/cm and 1.413ms/cm. Use the provided conductivity solutions and follow the calibration procedure.

6. Specifications

ParameterRangeResolutionAccuracy
PH0.00 - 14.00PH0.01PH± 0.03PH
ORP-2000mv - +2000mv1mV± 5mv
EC0-19000us/cm, 0-199.0ms/cm1us/cm (<1999us/cm), 10us/cm (>1999us/cm), 0.1ms/cm±2% F.S
TDS0-19990ppm, 0-199.0ppt1ppm (<1999ppm), 10ppm (>1999ppm), 0.1ppt±2% F.S
SALT0-199.9ppt, 0%-20%0.01%±2% F.S
S.G0.990-1.4000.001N/A
Temperature0-50°C (32-122°F)0.1°C (0.2°F)±1.0°C (±2°F)
CF0-1999.0 CF1CFN/A
  • Operating Temperature: 0°C ~ 50°C
  • Temperature Compensation: 0°C ~ 50°C
  • Power Supply: DC6V
  • Dimensions: 152 mm x 80 mm x 26 mm (5.98 in x 3.07 in x 0.98 in)
  • Weight: 245g
  • Connectivity: WiFi (Tuya Smart APP)
  • Display Type: DIGITAL with Backlight
  • Battery Included: No
  • Certification: CE
Image showing the dimensions of the Yieryi PH-W218 main unit: 152mm length, 78mm width, 25mm height, and 1.1m wire length.
Figure 6.1: Product Dimensions

7. Maintenance

  • Probe Care: Always keep the probes clean. Rinse them with distilled water after each use to prevent contamination.
  • Storage: Store the probes in their protective caps, ideally with a small amount of storage solution (for pH and ORP probes) to keep them hydrated.
  • Cleaning: Wipe the main unit with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water.
  • Calibration: Calibrate the device regularly, especially if you notice inconsistent readings or after prolonged storage, to maintain accuracy.

8. Troubleshooting

  • Device not powering on: Ensure the power adapter is correctly connected to the unit and a working power outlet. Verify you are using the supplied power adapter, not a mobile phone USB cable.
  • WiFi connection issues:
    • Ensure the device's WiFi is enabled (long press "MODE" key).
    • Check your WiFi network name and password in the Tuya Smart APP.
    • Make sure the device is within range of your WiFi router.
    • Restart the device and try connecting again.
  • Inaccurate readings:
    • Clean the probes thoroughly.
    • Perform a full calibration for the affected parameter.
    • Ensure probes are fully immersed in the sample.
    • Check for any damage to the probes or their cables.
  • App not displaying data:
    • Verify the device is successfully connected to WiFi and the Tuya Smart APP.
    • Check your internet connection on your smartphone.
    • Restart the app or the device.

9. User Tips

  • For best results, allow the probes to stabilize in the water sample for a few minutes before taking a final reading.
  • When setting alarm thresholds in the app, consider the specific needs of your application (e.g., fish tank, hydroponics) to prevent false alarms or missed critical changes.
  • Utilize the data logging and export features to track trends over time, which can be invaluable for maintaining stable water conditions.
  • Always use fresh calibration solutions for accurate calibration. Do not reuse old solutions.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.