Yieryi PH-W218

Contents

Yieryi WiFi Tuya Smart Water Quality Monitor Meter

Model: PH-W218

Brand: Yieryi

1. Introduction

The Yieryi PH-W218 is an advanced 8-in-1 WiFi online water quality monitor meter designed for comprehensive analysis of various water parameters. This smart device integrates with the Tuya Smart APP, allowing for real-time data monitoring, historical data logging, and alert notifications directly on your smartphone. It is suitable for a wide range of applications including aquariums, mariculture, drinking water, water sources, soilless cultivation, hydroponics, laboratories, spas, and swimming pools.

This manual provides detailed instructions for setting up, operating, calibrating, and maintaining your PH-W218 monitor to ensure accurate and reliable performance.

2. Safety Information

  • Power Supply: Always use the provided power adapter to connect the device to the power supply. Do NOT use a mobile phone USB cable, as it is not compatible and may damage the product.
  • Water Exposure: This tester is NOT waterproof. To prevent damage and ensure proper function, do not allow the tester to get wet or damp during use.
  • Probe Handling: Handle probes with care. Avoid dropping or bending them, as this can affect accuracy.
  • Storage: Store the device and probes in a clean, dry environment when not in use.

3. Package Contents

Please check the contents of your package against the list below. If any items are missing or damaged, contact your retailer.

Standard Package (PH-W218EU/US/AU/UK):

  • 1 x Monitor Unit
  • 1 x PH Probe
  • 1 x ORP Probe
  • 1 x PPM/EC/Salt/S.G./CF Probe
  • 1 x Temp Probe
  • 1 x Charger (EU/US/AU/UK plug type, depending on selection)
  • 1 x English User Manual
  • 2 x Suction Cups
  • 1 x Clip
  • 1 x 4.0 PH Calibration Powder
  • 1 x 6.86 PH Calibration Powder
  • 1 x 9.18 PH Calibration Powder

Package with Liquid (PH-W218EU-P/US-P/AU-P/UK-P):

This package includes all items from the Standard Package, PLUS:

  • 1 x ORP Calibration Powder
  • 1 x 1413us/cm/25ml EC Calibration Solution
  • 1 x 12.88ms/cm/25ml EC Calibration Solution
Yieryi PH-W218 Monitor and Probes

Image: Yieryi PH-W218 Monitor with connected probes and power adapter.

4. Product Overview

The PH-W218 monitor features a clear digital display for multiple parameters and dedicated buttons for calibration and mode switching. It comes with four specialized probes for comprehensive water quality analysis.

8-in-1 Water Quality Monitoring Display

Image: Front view of the PH-W218 monitor displaying 8-in-1 water quality parameters.

Components:

Labeled diagram of PH-W218 components

Image: Detailed diagram labeling the monitor's displays, buttons, and probe connection points.

  • Power Adapter: For connecting the device to a power source.
  • PH/TEMP Display: Shows pH and temperature readings.
  • ORP Display: Shows Oxidation-Reduction Potential readings.
  • PPM/EC/SALT/S.G/CF Display: Shows Total Dissolved Solids (PPM), Electrical Conductivity (EC), Salinity (SALT), Specific Gravity (S.G), and Conductivity Factor (CF) readings.
  • ORP Calibration Key (CAL): Used for ORP probe calibration.
  • PPM/EC/SALT/S.G/CF Switch Key (MODE): Short press to cycle through PPM/EC/SALT/S.G/CF measurements. Long press to turn WiFi on/off.
  • EC/ORP+ Calibration Key (CAL): Used for EC probe calibration.
  • °C/°F Switch Key (TEMP CAL): Short press to switch between Celsius and Fahrenheit. Long press to select PH for calibration.
  • TEMP Connection Probe: Connects the temperature sensor.
  • ORP Connection Probe: Connects the ORP electrode.
  • PH Connection Probe: Connects the pH electrode.
  • PPM/EC/SALT/S.G/CF Connection Probe: Connects the multi-parameter electrode.

5. Setup

  1. Connect Probes: Carefully connect the PH, ORP, PPM/EC/SALT/S.G/CF, and TEMP probes to their respective ports on the main monitor unit. Ensure connections are secure.
  2. Connect Power: Plug the provided charger into the power adapter port on the monitor, then connect the adapter to a suitable power outlet. The device will power on automatically.
  3. Mounting: The monitor features a hook design for easy wall mounting. Use the included suction cups and clip to secure the probes in your water source.
Wall-mounted design for the PH-W218 monitor

Image: PH-W218 monitor mounted on a wall next to an aquarium, with probes immersed in water.

6. WiFi Connection & App Setup

The PH-W218 connects to the Tuya Smart APP for remote monitoring and data management. The app is compatible with both Apple and Android systems.

Video: Step-by-step guide on connecting the Yieryi PH-W218 to the Tuya Smart APP via WiFi.

  1. Download Tuya Smart APP: Search for "Tuya Smart" in your device's app store (Google Play Store for Android, Apple App Store for iOS) and install it.
  2. Register/Log In: Open the Tuya Smart APP and register for a new account or log in with an existing one.
  3. Enable WiFi on Device: Long press the "MODE" button on the PH-W218 monitor until the WiFi indicator starts blinking, indicating it's in pairing mode.
  4. Add Device in App: In the Tuya Smart APP, tap the "+" icon (or "Add Device") to add a new device. The app should automatically discover the PH-W218. If not, select "Add Manually" and choose the appropriate device type (e.g., "Sensors" or "Others" then "Wi-Fi Smart Online Water Quality Tester").
  5. Enter WiFi Information: Follow the on-screen prompts to enter your home WiFi network name and password. Ensure your phone is connected to a 2.4GHz WiFi network.
  6. Pairing: The app will attempt to pair with the device. Once successfully connected, the WiFi indicator on the monitor will become solid, and the device will appear in your Tuya Smart APP.
  7. Multiple Devices: The app supports connecting up to 20 devices simultaneously, automatically naming them (e.g., Device 1, Device 2).
Tuya Smart APP connection process

Image: Illustration of the WiFi connection and data transfer process with the Tuya Smart APP.

7. Operation

7.1 Real-Time Monitoring

Once connected to the Tuya Smart APP, you can monitor water quality parameters in real-time from your smartphone. The device continuously transmits data every 15 seconds.

Mobile Application Monitoring Interface

Image: Screenshots of the mobile application interface showing various water quality parameters.

7.2 Viewing Historical Data

The app records data over time, allowing you to view daily, weekly, and monthly trends. Click on a specific parameter (e.g., pH) in the app to view its detailed history and data graphs for comparative analysis.

Real-time data detection and historical graphs

Image: App interface showing real-time pH and temperature, along with options to view daily, weekly, and monthly data.

7.3 Switching Measurement Units/Modes

  • Temperature Unit (°C/°F): Short press the "TEMP CAL" button on the monitor to switch between Celsius and Fahrenheit.
  • Multi-Parameter Mode (PPM/EC/SALT/S.G/CF): Short press the "MODE" button on the monitor to cycle through the different measurement modes for the multi-parameter probe.
Switching temperature units

Image: Demonstrates short pressing the TEMP CAL key to switch between °C and °F.

Switching multi-parameter modes

Image: Demonstrates short pressing the MODE key to select PPM/EC/SALT/S.G/CF for measurement.

7.4 Data Export

The PH-W218 supports data export to your email. You can export daily, weekly, or monthly data in a form format. After sending the email, you will need to click a download link within the email to access the data.

Data export to Excel via email

Image: Steps for exporting data from the app to email and then downloading it.

7.5 Alarm Settings

Within the Tuya Smart APP, you can set high and low alarm values for parameters like pH. The app can then provide SMS notifications or pop-up screen prompts if the readings fall outside your set thresholds.

8. Calibration

Regular calibration ensures the accuracy of your water quality monitor. Always use fresh calibration solutions.

Calibration powders and solutions

Image: Various calibration powders for pH and ORP, and conductivity solutions for EC.

8.1 PH Calibration

The PH-W218 supports 3-point pH calibration. You can choose between two sets of calibration points: 6.86, 4.00, 9.18 or 7.00, 4.00, 10.00. The factory default calibration is 6.86, 4.00, 9.18.

  1. Prepare the pH calibration powders by dissolving them in distilled water according to their instructions.
  2. Long press the "TEMP CAL" button on the monitor to select PH for calibration.
  3. Follow the on-screen instructions or refer to the detailed steps in the app for each calibration point.

8.2 ORP Calibration

ORP calibration points are 265mV and 100mV.

  1. Prepare the ORP calibration powder by dissolving it in distilled water according to its instructions.
  2. Press the "CAL" button under the ORP display to initiate ORP calibration.
  3. Follow the on-screen instructions or app prompts for calibration.

8.3 EC Calibration

EC calibration points are 12.88ms/cm and 1.413ms/cm.

  1. Prepare the EC calibration solutions.
  2. Press the "CAL" button under the PPM/EC/SALT/S.G/CF display to initiate EC calibration.
  3. Follow the on-screen instructions or app prompts for calibration.

9. Maintenance

9.1 Probe Care

  • Cleaning: Regularly clean the probes with distilled water to remove any residue that might affect readings. For stubborn deposits, use a soft brush and a mild cleaning solution, then rinse thoroughly.
  • Storage: When not in use, ensure pH and ORP probes are stored in their protective caps with a small amount of storage solution or saturated KCl solution to prevent drying out. EC/TDS probes can be stored dry after rinsing.
  • Replacement: Probes have a limited lifespan and may need replacement if they no longer calibrate correctly or provide stable readings.

9.2 Device Cleaning

  • Wipe the main monitor unit with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water.

10. Troubleshooting

  • Device Not Powering On: Ensure the correct power adapter is securely connected to the monitor and a working power outlet. Do not use a mobile phone USB cable.
  • WiFi Connection Issues:
    • Ensure the monitor's WiFi indicator is blinking during pairing (long press MODE button).
    • Verify your smartphone is connected to a 2.4GHz WiFi network.
    • Check that the WiFi password entered in the Tuya Smart APP is correct.
    • Move the device closer to your WiFi router.
  • Inaccurate Readings:
    • Perform a calibration for the affected parameter (pH, ORP, EC).
    • Clean the probes thoroughly to remove any buildup.
    • Ensure probes are fully immersed in the sample water.
    • Check if the probes are damaged and consider replacement if necessary.
  • App Not Displaying Data:
    • Check your internet connection on your smartphone.
    • Ensure the device is successfully connected to WiFi and the Tuya Smart APP.
    • Restart the app and/or the monitor.

11. Specifications

Yieryi PH-W218 Specifications Table

Image: Table detailing the range, resolution, and accuracy for each measurement parameter.

Yieryi PH-W218 Technical Specifications
Parameter Range Resolution Accuracy
PH 0.00 - 14.00PH 0.01PH ± 0.03 PH
ORP -2000mv - +2000mv 1mV ± 5mv
EC 0 - 19000us/cm, 0 - 199.0ms/cm 1us/cm (<1999), 10us/cm (>1999), 0.1ms/cm ± 2% F.S
TDS 0 - 19990ppm, 0 - 199.0ppt 1ppm (<1999), 10ppm (>1999), 0.1ppt ± 2% F.S
SALT 0 - 199.9ppt, 0% - 20% 1ppm (<1999), 10ppm (>1999), 0.1ppt, 0.01% ± 2% F.S
S.G 0.990 - 1.400 0.001 ± 2% F.S
CF 0 - 1999.0 CF 1CF ± 2% F.S
Temperature 0 - 50°C (32 - 122°F) 0.1°C (0.2°F) ± 1.0°C (± 2°F)
  • Operating Temperature: 0°C ~ 50°C
  • Temperature Compensation: 0°C ~ 50°C
  • Power Supply: DC6V
  • Dimensions: 152 mm x 80 mm x 26 mm (5.98in x 3.07in x 0.98in)
  • Weight: 245g
Yieryi PH-W218 Dimensions

Image: Diagram showing the dimensions of the PH-W218 monitor.

12. User Tips

  • Calibration Solutions: If you require a full set of liquid calibration solutions (beyond just pH powders), ensure you select the product option that explicitly includes them (e.g., "With Liquid").
  • Jacuzzi Use: While the device is suitable for various water types, for specific applications like Jacuzzis, it's advisable to consult the manufacturer's guidelines for your Jacuzzi to ensure compatibility with continuous monitoring devices and probe materials.
  • App Language: The Tuya Smart APP automatically converts language based on your phone's language and region settings.

13. Warranty and Support

For any technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact the seller or manufacturer directly. Refer to your purchase documentation for specific warranty terms and contact information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.