1. Introduction
The JIKONG Lithium Battery Intelligent Protection Board (BMS) is a sophisticated management system designed for large-capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, high-current active balancing, overcharge/over-discharge/over-current/over-temperature protection, coulomb metering, Bluetooth communication, and host computer monitoring. This BMS is suitable for various battery types including lithium iron phosphate (LiFePO4), ternary lithium, and lithium titanate (LTO).
The protection board utilizes energy transfer active balancing technology with independent intellectual property rights, achieving a continuous balance current of up to 1A/2A. This high-current active equalization technology ensures battery consistency, extends battery life, and delays battery aging. It is ideal for high-power energy storage systems, base station backup power supplies, and solar power station battery PACKs.
2. Specifications
2.1. Key Features
- LED Bluetooth Status Indicator: Provides visual feedback on the BMS's operational status.
- APP Bluetooth Remote Operation: Control and monitor the BMS via a mobile application (Android/iOS/HarmonyOS).
- Battery Capacity Calculation: Accurate tracking of battery capacity.
- PC Operations Support: Compatible with PC monitoring software.
- High Precision Voltage Acquisition: Measures voltage with an accuracy of ±3mV.
- High Precision Current Acquisition: Monitors current accurately.
- Information Screen Display: Supports external display for real-time data viewing.
- Accurate Time Logging: Records operational data with precise timestamps.
- Communication Interfaces: Supports RS485 and CAN communication.
- Heating Function: Integrated heating for low-temperature environments.
- Alarm Dry Contact Function: Provides dry contact outputs for external alarms or cooling fans.
- Comprehensive Protection: Includes overcharge, over-discharge, overcurrent (charge/discharge), over-temperature (charge/discharge), low-temperature (charge), and short circuit protection.
- Battery Parallel Current Limiting Function: Manages current when batteries are connected in parallel.
2.2. Product Parameters
| Technical Index | JK-PB2A16S20P |
|---|---|
| Number of Battery Strings (Li-ion) | 7S-16S |
| Number of Battery Strings (LiFePO4) | 8S-16S |
| Number of Battery Strings (LTO) | 14S-16S |
| Balance Method | Active Balance (Full State On) |
| Balance Current | 2A |
| Conductive Resistance in Main Circuit | 0.3mΩ |
| Continuous Discharge Current | 200A |
| Maximum Discharge Current (MAX 2min) | 350A |
| Over Charge Protection Current (ADJ) | 10-200A |
| Other Interfaces (Default) | RS485/232/CAN |
| Wiring Output | Common Port |
| Single Cell Voltage Range | 1-5V |
| Voltage Acquisition Accuracy | ±5mV |
| Over Charge Protection Voltage | 1.2-4.35V Adjustable |
| Over Charge Release Voltage | 1.2-4.35V Adjustable |
| Over Current Detect Delay | 2-120S Adjustable |
| Over Discharge Protection Voltage | 1.2-4.35V Adjustable |
| Over Discharge Release Voltage | 1.2-4.35V Adjustable |
| Quantity of Temperature Detection | 4 |
| Temp Protection | Yes |
| Short Circuit Protection | Yes |
| Coulomb Counter | Yes |
| Bluetooth Function | Support for Android/iOS/Harmony |
| Parallel charging current limiting | 10A |
| Address dial switch | 4 |
| DRY Contact | 2 |
| Parameter | Value | Unit |
|---|---|---|
| Supply voltage | 20-70 | V |
| Standby power consumption | 12 | mW |
| Operating power consumption | 1100 | mW |
| Operating temperature | -30-70 | °C |
| Maximum number of collection strings | 16 | S |
| Maximum balancing current | 2 | A |
| Maximum charging current (20P) | 200 | A |
| Maximum discharge current (20P) | 200 | A |
| Maximum instantaneous current (20P) | 400 | A |
| Maximum internal loop resistance (20P) | 0.35 | mΩ |
| Protective plate size | 300*100*24 | mm |
| Finished weight | 1000 | g |
2.3. Physical Dimensions

The main BMS protection board dimensions are 300mm x 100mm x 24mm. The interface board has separate dimensions.

3. Setup and Installation
3.1. Packing List
Before installation, please verify that all components are present:

3.2. Wiring Instructions
The JIKONG-PB1/2A16S-10/15/20P series protection board is suitable for 7-16 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure all cables are connected correctly before powering on the BMS.
- Connect all the cables as shown in the diagrams.
- Insert the balance cable into the BMS.
- Connect the B-line and the P-line to the battery.
- Important: If there are two B8 cables, only the first B8 line needs to be connected. The second B8 cable does not need to be connected.

3.3. Interface Board Functions and Connections
The interface board provides LED indicators, a reset switch, DIP switches, and dry contact outputs. It facilitates communication via CAN and RS485. The LED indicators help determine the BMS's working status and remaining battery power. The reset button can be used to reset the BMS if issues occur. DIP switches are used to set the address when multiple BMS units are used in parallel.

3.4. Device Activation
Before powering on the protection board, double-check that the balance cables are properly connected and that P- and B- are correctly wired. Ensure the protection board is securely fixed to the battery cells. Once confirmed, power on the board.
The BMS does not have a power-on control switch. It is designed for charging activation mode, meaning the charger voltage must be 2V higher than the battery voltage. After battery assembly, connect the charger to activate the protection board.
Alternatively, the protection board supports key activation and display activation. If you have the display screen and button, simply insert the cable into the display interface and press the button to activate.
4. Operating Instructions
4.1. Mobile APP Installation and Usage
The mobile APP for the JIKONG BMS supports Android, iOS, and HarmonyOS. You can download the APP by scanning the QR code provided in the manual. Android Version 7 or higher is required.

The APP allows you to view the battery's working status, modify protection parameters, and control charge/discharge switches. All information is clear at a glance.
4.2. Active Equalization
The active equalization function transfers energy from high-voltage cells to low-voltage cells to maintain battery consistency. Before using, set basic battery parameters (battery type, number of cells, capacity, trigger equalization differential pressure, voltage/current calibration) in the APP's parameter settings. The default balance current is 1A/2A. It is recommended that the balance current does not exceed 0.2C of the battery capacity. If not needed, the equalization switch can be turned off in the APP's BMS control page.4.3. Communication Functions
The BMS supports CAN and RS485 communication. The default CAN communication rate is 250K. You can select the appropriate inverter protocol in the APP based on your inverter brand and specifications.
There are two RS45 communication interfaces: RS485-1 for communication with inverters and other settings, and RS485-2 for connecting battery packs in parallel and communicating with a host computer. The default baud rate for RS485 is 115200. The communication address can be set via DIP switches (0-15).

4.4. Parallel Function
The parallel function allows simultaneous monitoring of multiple BMS units via a host computer using the RS485 bus. This requires a USB to RS485 serial port cable and JIKONG host computer software. The system supports up to 16 BMS units, each requiring a unique address (0-15) set via DIP switches. Address 0 is for the host BMS, and 1-15 are for slave units.

5. Maintenance and Protection Features
5.1. Overcharge Protection and Recovery
The BMS includes standard overcharge protection. Users can set the single cell overcharge protection voltage and recovery voltage in the APP. If any cell exceeds the set voltage during charging, the BMS will stop charging. Charging resumes when all cell voltages fall below the recovery voltage.5.2. Over-discharge Protection and Recovery
Standard over-discharge protection is included. Users can set battery under-voltage protection voltage, recovery voltage, and automatic shutdown voltage in the APP. If any cell falls below the set under-voltage protection during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the recovery voltage. If any cell falls below the automatic shutdown voltage, the BMS will shut down to protect the battery.5.3. Overcurrent Protection and Recovery (Charge/Discharge)
The BMS features overcurrent protection for both charging and discharging. Users can set continuous current limits, overcurrent delay, and recovery time in the APP. If the current exceeds the limit for the set delay, the BMS will stop the respective operation. It will resume after the recovery time.5.4. Over-temperature and Low-temperature Protection and Recovery
The BMS provides over-temperature protection for both charging and discharging, and low-temperature protection for charging. Users can set protection and recovery temperatures in the APP. If temperatures exceed or fall below the set limits, the BMS will stop the respective operation until temperatures return to safe levels. For cold environments, using the heating function is recommended.5.5. Short Circuit Protection and Recovery
Short circuit protection is standard. Users can set the short circuit protection delay and recovery time in the APP. If a short circuit is detected, the BMS will activate protection. The delay can be adjusted to prevent false triggers from peak currents during charger connection or capacitive loads.5.6. Heating Function
The BMS includes a heating function to warm the battery in low-temperature conditions, preventing performance degradation. It uses a resistance heater or heating film with a designed current of 10A. Users can control this function via the APP. It is recommended to install a temperature control switch (45°C to 65°C normally closed) in series with the heating circuit for secondary protection against thermal runaway.5.7. Emergency Switch
The emergency switch function allows the BMS to force charge and discharge for 30 minutes if issues like over-temperature, over-discharge, overcharge, or dropped strings occur. This provides a temporary operational window. Even if a single cell reaches the automatic shutdown voltage, the BMS will continue to operate for the 30-minute emergency cycle.5.8. Intelligent Sleep
The intelligent sleep function, configurable via the APP, puts the BMS into a low-power state if it remains in standby (charging/discharging current less than 1A) for 26 consecutive hours. This reduces energy consumption. The BMS can be reactivated by pressing a button or connecting a charger.
6. Troubleshooting and LED Indicators
The BMS provides various LED indicators on the interface board to help diagnose issues:
| Status | Normal, Alarm, or Protection | ON/OFF Indicator | RUN | ALM | Instructions |
|---|---|---|---|---|---|
| Power Off | Normal | OFF | OFF | ||
| Balance | Normal | ON | Flicker | OFF | Based on battery display |
| Charging (Normal) | Normal | ON | Flicker | OFF | Based on battery display |
| Charging (Overcurrent, Overtemp, Overvoltage, Charging Failure) | Protection | ON | Flicker | Flicker | Based on battery display |
| Discharge (Normal) | Normal | ON | Flicker | OFF | Based on battery display |
| Discharge (Overcurrent, Overtemp, Undervoltage, Discharge Failure) | Protection | ON | Flicker | Flicker | Based on battery display |
| Other Alarms (Password not changed, Short circuit, Temperature abnormal) | Alarm | ON | Flicker | Flicker | Based on battery display |
| Capacity (%) | Charging (L5-L1) | Discharge (L5-L1) | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 0-20% | OFF | OFF | OFF | OFF | ON | OFF | OFF | OFF | OFF | ON |
| 20-40% | OFF | OFF | OFF | ON | ON | OFF | OFF | OFF | ON | ON |
| 40-60% | OFF | OFF | ON | ON | ON | OFF | OFF | ON | ON | ON |
| 60-80% | OFF | ON | ON | ON | ON | OFF | ON | ON | ON | ON |
| 80-100% | ON | ON | ON | ON | ON | ON | ON | ON | ON | ON |
Note: ON indicates that the LED is on, OFF indicates that the LED is off.
7. User Tips
- Always ensure all wiring connections are secure and correct before applying power to prevent damage.
- Regularly check the APP for battery status and adjust parameters as needed for optimal performance.
- When using the heating function in cold weather, consider adding an external temperature sensor for precise control.
- For parallel setups, carefully configure the DIP switch addresses for each BMS to ensure proper communication.
8. Warranty and Support
For detailed warranty information and technical support, please refer to the official JIKONG product documentation or contact your seller. A comprehensive user manual in PDF format is available for download, which contains additional technical details and parameter settings. (Reference: User manual (PDF))