1. Product Overview
The JK BMS Smart Active Balance Battery Management System is an advanced solution for managing various battery types, including LiFePO4, Ternary Lithium, and Lithium Titanate. It features real-time active energy transfer equalization, Bluetooth communication, and comprehensive protection functions to ensure battery longevity and performance.
Key Features:
- Active balance for enhanced battery consistency and extended life.
- Real-time active energy transfer equalization using supercapacitors.
- Single cell voltage range: 1V~5V with ±5mV equalization accuracy.
- Continuous balanced current of 1-2A.
- Mobile phone Bluetooth communication with dedicated APP (Android/iOS).
- Support for balanced cascading for battery packs exceeding 24 cells.
- Suitable for 4S-8S battery configurations.
- Integrated protection functions: Overcharge, Short Circuit, Over Discharge, Overcurrent, All-in (cable drop/poor contact), and Over Temperature.
Application Scenarios:
This BMS is suitable for a wide range of applications, including E-bikes, Electric Tricycles, Low Speed Quads, Forklifts, Cleaning Cars, Tourist Cars, Industrial Drones, Scooters, RV Energy Storage, Energy Storage Cabinets, Power Banks, and Power Tools.

Package Contents:
- 1 x BMS Unit (Bluetooth built-in)
- 1 x Temperature Sensor (40cm)
- 1 x Balance Wires (75cm)
- 1 x Active Switch (15cm)
- 1 x Heating Cable (included only for BMS models with Heat Function)
Note: RS485 and LCD interfaces are configured by default on all JK BMS units (except JK-BD4A17S4P for LCD). CANBUS interface and Heat Function are customizable options.
2. Specifications
The following table outlines the general specifications for various JK Smart Active BMS models. Please refer to the specific model purchased for exact details.

General Technical Index:
| Feature | Specification |
|---|---|
| High-concerned chemical | None |
| Charging Current | 200A (for JK-B2A8S20P) |
| Usage Scenario | Power BMS, Energy Storage BMS |
| Certification | CE, RoHS |
| Balance Function | Active Balanced BMS |
| Hardware or Smart | SMART BMS |
| Charge and Discharge Port | Common Port BMS |
| Type | LIFEPO4 Battery BMS |
| Function | Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection |
| Battery series | 4S 5S 6S 7S 8S |
| Applications | Lithium battery rated |
| Over charge protection | YES |
| Over discharge voltage | YES |
| Short circuit protection | YES |
| Balance function | YES |
| Bluetooth | YES |
| RS485 | Available for purchase (often default) |
| GPS | According to Customer need |
| CAN | According to Customer need |
| Accessory | Wire cable is free |
| Balance Mode | Active balance |
| Suitable for battery type | Lithium iron phosphate, ternary lithium, lithium titanate and other battery types. |
| Single voltage range | 1V~5V |
| Over current protection | YES |
| Dropout protection | YES |
| Over temperature protection | YES |
Dimensions:

Typical dimensions for models like JK-B1A8S20P/JK-B2A8S20P are approximately 153mm x 136mm x 17.6mm.
3. Setup and Installation
Wiring Method:
Follow these steps for proper wiring. This example uses a single series connection, but the principles extend to other series BMS configurations.

- Find P-, B- Position: Locate the P- and B- terminals on the protection board. The B- terminal is the first wire corresponding to the black row of wires. Ensure the cable is fully inserted into the protection board, paying attention to the front and back of the cable.
- Find Total Negative Terminal: Identify the total negative terminal of the battery pack. This is the first string of batteries. The total positive terminal is the last string. For example, with an 18650 Carp battery pack, different battery packs have different positive and negative positions. Use a multimeter for accurate measurement.
- Connect Balance Wires: Connect the first wire to the negative terminal of the first battery, the second wire to the positive terminal of the first series of batteries, the third wire to the positive terminal of the second series of batteries, and so on. Do not skip any numbers of strings.
- Verify Voltage: In the head of one line from the first line, measure the voltage between each of the two lines. For ternary batteries (3V-4.2V) or lithium iron phosphate (2.5-3.6V), if the measurement is outside the range, it indicates incorrect connection. Double-check and ensure the line is correctly plugged into the protection board. Incorrect wiring can damage the board.
- Connect P-B- Wires: After confirming all wires are correctly connected, connect the B- to the total negative of the battery (wire length within 15cm is recommended). Insert the connected wires, measure the protection board B- and the total positive voltage. This should be equal to the total positive voltage of the P- and equal to the total positive voltage, representing correct charging and discharging interface connections.
Parallel Operation:
If you need to use multiple BMS units in parallel, a Fast Class T Fuse must be added to each battery pack for safety. Alternatively, a high-power discharge diode (selected according to the load) can be used.

Connection Mode Examples:

Refer to the provided diagrams for specific connection modes based on your battery series (e.g., 24S, 20S, 17S, 16S, 14S, 13S, 8S, 7S).
4. Operating Instructions
Initial Setup and APP Connection:

- Download APP: Scan the QR code on the BMS unit or search for "JIKONG BMS" in the App Store (iOS) or use the Android download link: https://www.pgyer.com/Cfq3.
- Hardware Connection: Ensure all wiring is correctly connected as per the setup instructions.
- Startup: The total voltage of the battery pack must be greater than 20V before starting up the BMS. Use the display activation button or an additional switch to activate the BMS.
- Connect to APP: Ensure your mobile device's Bluetooth is turned on. Open the JIKONG BMS APP, click on the top left corner to search for devices. Select your device name to connect. The default password is 1234.
- Set Parameters: For the first start-up, parameters need to be set. The default parameter setting password is 123456. Set the number of units (cells) and battery type (LiFePO4, Ternary, LTO).
- Check Battery Status: Once parameters are set, navigate to the real-time status page. Check the battery status. An error message indicates a prompt and normal operation. Blue indicates the highest voltage, and red indicates the lowest voltage.
Smart Energy Working Modes:

- Storage Mode: In this mode (transportation, storage, offline, or wireless transmission off), the BMS does not consume battery pack current.
- Normal Working Mode: When the charger is inserted while the BMS is in storage mode, the BMS will immediately return to normal working mode. All protection, equalization, and communication functions will resume.
- Shutdown: To prevent power waste during long periods of disuse, the BMS automatically shuts down when a cell voltage falls below the predefined shutdown voltage.
- Standby Mode: When the battery pack is in a static state (no charge, discharge, or equilibrium), the BMS will automatically enter standby mode after a set time (1-30 days, configurable).
Heating Function (if applicable):
If your BMS includes the heating function, the green 5PIN cable connects to the heating pad, and the black and red cables connect to a smart charger. The smart charger, linked to the BMS, will detect the battery temperature and automatically manage the charging status. Heating activates when the battery temperature falls below the low-temperature charge protection threshold (an APP-settable parameter), turning off charging and initiating heating. The heating power is dependent on the battery voltage and the resistance of the heating film.
5. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your BMS and battery pack.
- Regular Monitoring: Periodically check the battery status via the mobile APP to monitor cell voltages, temperature, and overall pack health.
- Connection Integrity: Ensure all wiring connections, especially balance wires and main power cables, are secure and free from corrosion or damage.
- Software Updates: Check for and install any available firmware or APP updates to ensure you have the latest features and bug fixes.
- Cleanliness: Keep the BMS unit clean and free from dust and debris to prevent overheating and ensure proper operation.
6. Troubleshooting
Common Faults and Solutions:
- No Power On:
- Ensure the "B+" line is correctly connected to the battery's total positive pole.
- For charge activation, ensure the charger voltage is at least 4V higher than the battery pack voltage.
- Verify that the charger has a voltage output.
- Voltage Inaccuracy:
- Measure the actual total voltage of the battery pack using a multimeter.
- Input this actual total voltage into the "Voltage Calibration" setting within the APP.
- Current Inaccuracy:
- Ensure both BMS B- and P- terminals are connected with two 7AWG wires in parallel. Incorrect wiring can lead to current errors.
- Use a clamp meter to measure the actual current of the battery pack. Input this value into the "Current Calibration" setting in the APP. Higher actual current values improve calibration accuracy.
- Capacity Inaccuracy:
- Set the battery capacity in the APP (e.g., for a 100Ah battery, set it to 120Ah or 150Ah).
- Discharge the battery using an electric instrument until the BMS triggers a single cell undervoltage protection.
- Charge the battery continuously until the BMS triggers a single cell over-voltage protection. Do not interrupt charging.
- After these steps, the capacity will automatically update, and the APP will display the accurate battery capacity and State of Charge (SOC).
- Number of Designed Strings Does Not Match Actual:
- Check if the "number of single unit" parameter in the APP settings is correct.
- If there is no voltage in the middle of two or more strings, check whether the collection line is disconnected or faulty.
7. User Tips
- Always double-check all wiring connections before powering on the BMS to prevent damage.
- Regularly monitor battery cell voltages and overall pack health via the mobile app.
- Ensure your charger is compatible with your battery chemistry (LiFePO4, Li-Ion, LTO) and voltage requirements.
- For parallel battery configurations, use appropriate fuses or discharge diodes for safety.
- Keep the BMS firmware updated for optimal performance and security.
8. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase records for reference.