1. Introduction
This manual provides comprehensive instructions for the JIKONG BMS JK-PB2A16S20P with a 4.3-inch display, designed for Lifepo4, Li-ion, and LTO battery systems. It covers product overview, specifications, installation, operation, and safety features to ensure optimal performance and longevity of your battery pack.

The JIKONG BMS is an intelligent protection board tailored for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge/over-temperature protection, coulomb metering, Bluetooth communication, and host computer monitoring. It is suitable for various battery types including lithium iron phosphate, ternary lithium, and lithium titanate.
The protection board utilizes energy transfer active balancing technology, achieving a continuous balance current of 1A/2A. This technology ensures battery consistency, extends cruising range, and delays battery aging. A mobile APP (Android and iOS compatible) allows users to monitor battery status, modify parameters, and control charge/discharge switches via Bluetooth. The compact design, simple operation, and comprehensive functions make it ideal for high-power energy storage, base station backup power, and solar power station battery packs.

Video 1: JIKONG BMS manufacturing process and product overview.
For a detailed product specification, please refer to the official user manual PDF: JIKONG Energy Storage Series BMS Product Specification (PDF).
2. Specifications
2.1. General Specifications
| Attribute | Value |
|---|---|
| Brand Name | JIKONG |
| Type | Lifepo4 Li-ion LTO Battery BMS |
| Usage Scenario | Energy Storage BMS |
| Handware or Smart | SMART BMS |
| Balance Function | Active Balanced BMS |
| Charge and Discharge Port | Common Port BMS |
| Function | Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection |
| Charging Current | 200A |
| Certification | CE, FCC, WEEE |
| High-concerned chemical | None |
2.2. Detailed Product Specifications (Model JK-PB2A16S20P)

| Technical Index | JK-PB2A16S20P |
|---|---|
| Number of Battery Strings (Li-ion) | 7S-16S |
| Number of Battery Strings (Lifepo4) | 8S-16S |
| Number of Battery Strings (LTO) | 14S-16S |
| Balance Method | Active Balance (Full State On) |
| Balance Current | 2A |
| Conductive Resistance in Main Circuit | 0.3mΩ |
| Continuous Discharge Current | 200A |
| Maximum Discharge Current (MAX 2min) | 350A |
| Over Charge Protection Current (ADJ) | 10-200A |
| Other Interfaces (Default) | RS485/232/CAN |
| Wiring Output | Common Port |
| Single Cell Voltage Range | 1-5V |
| Voltage Acquisition Accuracy | ±5mV |
| Over Charge Protection Voltage | 1.2-4.35V Adjustable |
| Over Charge Release Voltage | 1.2-4.35V Adjustable |
| Over Current Detect Delay | 2-120S Adjustable |
| Over Discharge Protection Voltage | 1.2-4.35V Adjustable |
| Over Discharge Release Voltage | 1.2-4.35V Adjustable |
| Quantity of Temperature Detection | 4 |
| Temp Protection | Yes |
| Short Circuit protection | Yes |
| Coulomb Counter | Yes |
| Bluetooth Function | Support for Android/iOS/Harmony |
| Parallel charging current limiting | 10A |
| Address dial switch | 4 |
| DRY Contact | 2 |
2.3. Physical Dimensions
| Attribute | Value |
|---|---|
| Supply voltage | 20-70 V |
| Standby power consumption | 12 mW |
| Operating power consumption | 1100 mW |
| Operating temperature | -30-70 ℃ |
| Maximum number of collection strings | 16 S |
| Maximum balancing current | 2 A |
| Maximum charging current | 200 A |
| Maximum discharge current | 200 A |
| Maximum instantaneous current | 400 A |
| Maximum internal loop resistance | 0.35 mΩ |
| Protective plate size | 300*100*18 mm |
| Finished weight | 1000 g |


3. Package Contents
The standard package for the JIKONG BMS includes the following items:

- BMS x 1
- Interface board x 1
- Adapter cable B x 1 (long 30cm)
- Adapter cable A x 1 (long 30cm)
- R545 Network cable x 1 (long 40cm)
- Sampling line A x 2 (long 90cm)
- Sampling line B x 1 (long 90cm)
- Sampling line C x 1 (long 90cm)
- Switch x 1 (long 50cm)
- Adapter cable C x 1 (long 30cm)
- Heating Adapter cable x 1 (long 15cm)
- Adapter x 1
4. Setup and Installation
4.1. Unpacking and Precautions
- Handle the packing box and protection board gently; do not turn upside down.
- Before unpacking, inspect the package for any impact marks or damage.
- The JK-PB1/2A16S-10/15/20P series protection board is suitable for 7-16 series lithium battery packs.
4.2. Wiring Instructions
Different cell counts require different wiring methods. Ensure correct connections to prevent damage.

- Connect all the cables.
- Insert the cable into the BMS.
- Connect the B-line and the P-line to the battery.
- Important Note: There are two B8 cables. Only the first B8 line needs to be connected. The second B8 cable does not need to be connected.
4.3. Interface Board Functions and Connections
The interface board (included) facilitates the use of LED indicators, a reset switch, DIP switches, dry contacts, and communication functions.

Interface Definitions:
| Connector | Interface Name | Pin Number | Name | Definition |
|---|---|---|---|---|
| P1 | Interface board interface | - | - | Interface board interface |
| P4 | Display interface | 1 | K- | Activation signal negative electrode |
| 2 | K+ | Activation signal positive electrode | ||
| 3 | GND | Negative terminal | ||
| 4 | B | Display RS485 signal negative | ||
| 5 | A | Display RS485 signal positive | ||
| 6 | VCC | Display power output | ||
| P5 | Acquisition interface | 1 | NT1 | Connect the NTC1 temperature probe |
| 2 | GND | Connect the NTC1 temperature probe | ||
| 3 | B0 | Total negative battery | ||
| 4 | B1 | The first battery positive | ||
| ... | ... | ... | ... | ... (up to B16 for 16S) |
| P9 | Heating interface | 1-5 | H+ | Power output, voltage close to B+ |
| 6 | CD+ | Charge indication input positive terminal | ||
| 7 | CD- | Charge indication input positive terminal | ||
| P10 | Power input (M3 screw) | 1 | B+ | Power input positive |
| P- | External load/charger negative | - | - | Connect to external load or negative terminal of charger, M6 screw |
| B- | Negative battery terminal | - | - | Connect to the negative battery terminal, M6 screw |
4.4. APP Installation
The mobile APP for the JIKONG BMS can be obtained by scanning the QR code below. Android Version 7 minimum is required.

5. Operating Instructions
5.1. Device Activation
Before powering on the protection board, ensure the balance cable is correctly connected and that P- and B- are correctly connected. Verify that the protection board is securely fixed to the battery core. Incorrect connections can lead to abnormal operation or damage.
The protection board does not have a physical power-on switch. It is designed for charging activation mode, meaning the charger voltage should be 2V higher than the battery voltage. After battery assembly, connect the charger to activate the protection board.
Alternatively, the protection board supports key activation and display activation. If you have the optional display screen and button, simply insert the cable into the display interface and press the button to activate.
5.2. Active Equalization
The BMS uses active equalization to transfer energy from high-voltage cells to low-voltage cells. Before using this function, set basic battery parameters in the JIKONG BMS APP, including the number of cells, battery capacity, and trigger equalization differential pressure (default value can be retained), voltage calibration, and current calibration.
The default balance current is 1A/2A. Adjust this current based on your battery capacity, ensuring it does not exceed 0.2C of the battery capacity. If balancing is not required, it can be turned off in the APP's BMS control page.

5.3. Display Interface
The BMS features a reserved display interface. You can connect the optional JIKONG 4.3-inch display to conveniently view battery information such as voltage, current, temperature, SOC, and alarm status.


5.4. Heating Function
The BMS includes a heating function to warm the battery at low temperatures, preventing reduced activity and ensuring proper charging/discharging. The designed heating current is 4A. Users can enable/disable this function via the APP based on ambient temperature.
For safety, it is recommended to install a temperature control switch (45°C to 65°C normally closed type) in series with the heating circuit as a secondary protection against thermal runaway.
5.5. Dry Contact Function
Two dry contacts are provided to control external devices like alarms or fans. When the BMS detects an over-temperature, overcharge, or over-discharge state, the alarm interface can switch the dry contact status to trigger a buzzer or activate a fan for cooling. Users can select two trigger conditions and configure them via the APP.

5.6. Communication Function
The BMS supports CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate protocol in the APP based on their inverter brand and specifications.
There are two RS485 communication interfaces: RS485-1 for communication with inverters and other settings, and RS485-2 for parallel connection of battery packs and communication with a host computer. The default baud rate is 115200. The communication address can be set using the DIP switch (0-15 range) for polling multiple battery packs.

5.7. Charge Current Limiting Function
The BMS includes a charge current limiting function. Users can set the continuous charging current (A), charging overcurrent delay (S), and charging overcurrent release time (S) in the APP. When the charging current exceeds the set limit for the specified delay, the current limiting function activates, maintaining the charging current at approximately 10A to protect the battery.
5.8. Parameter Setting
Refer to the "Instructions for Setting Protection Board Parameters" in the full PDF manual for detailed parameter configuration.
6. Safety Features and Protection
The JIKONG BMS is equipped with multiple protection mechanisms to ensure the safety and longevity of your battery system.
6.1. Overcharge Protection and Recovery
The BMS provides standard overcharge protection. Users can set the single overcharge protection voltage and recovery voltage in the APP. If any battery string exceeds the set overcharge voltage during charging, the BMS will stop charging. Charging resumes when all cell voltages drop below the recovery voltage.
6.2. Discharge Undervoltage Protection and Recovery
Standard discharge undervoltage protection is included. Users can set the undervoltage protection voltage, recovery voltage, and automatic shutdown voltage in the APP. If any cell voltage falls below the protection voltage during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the recovery voltage. If any cell voltage drops below the automatic shutdown voltage, the BMS will shut down to protect the battery.
6.3. Overcurrent Protection and Recovery (Charge & Discharge)
The BMS protects against overcurrent during both charging and discharging. Users can set continuous current limits, overcurrent delay times, and recovery times via the APP. If the current exceeds the set limit for the specified delay, the BMS will stop the operation. It will resume once the current returns to normal and the recovery time has passed.
6.4. Over-temperature and Low-temperature Protection and Recovery
The BMS includes both over-temperature and low-temperature protection for charging and discharging. Users can set the protection and recovery temperatures in the APP. If the battery temperature exceeds or falls below the set thresholds, the BMS will stop the respective operation (charging or discharging) and resume when the temperature returns to a safe range.
6.5. Short Circuit Protection and Recovery
Standard short circuit protection is provided. Users can set the short circuit protection delay (µs) and recovery time (S) in the APP. If a short circuit is detected, the BMS will stop operation and resume after the recovery time, provided the short circuit is resolved. Adjusting the delay can help prevent false triggers from high inrush currents during initial connection of chargers or loads.
6.6. Emergency Switch
The emergency switch function allows the BMS to enable both charge and discharge for 30 minutes even if issues like over-temperature, over-discharge, over-charge, or string drops occur. This provides a temporary operational window. The BMS will continue to operate for the full 30 minutes, even if cell voltages reach the automatic shutdown level, to prevent critical failures in situations like being stranded on the road.
6.7. Intelligent Sleep
The intelligent sleep function can be enabled or disabled via the APP. Its purpose is to reduce the BMS's self-consumption by shutting down when in standby (charging/discharging current less than 1A for 26 consecutive hours). The BMS can be reactivated by pressing a button or connecting a charger.
7. Troubleshooting
This section provides guidance for common issues you might encounter with your JIKONG BMS.
- BMS not activating after installation: Ensure all cables (balance, B-, P-) are correctly connected and securely fixed. Activate the BMS by connecting a charger (voltage 2V higher than battery) or by pressing the activation button if using the optional display.
- Battery not balancing: Check the active equalization settings in the APP. Verify that the balance trigger differential pressure is set correctly and that the balance current is appropriate for your battery capacity (not exceeding 0.2C). Ensure the balancing function is enabled.
- Charging/Discharging stops unexpectedly: Check for active protection triggers (overcharge, undervoltage, overcurrent, over-temperature, low-temperature, short circuit) in the APP. Address the underlying cause (e.g., high current draw, extreme temperatures) and allow the BMS to recover.
- Communication issues (Bluetooth/RS485/CAN): Ensure the APP is installed correctly and Bluetooth is enabled on your mobile device. For RS485/CAN, verify wiring, communication rates, and DIP switch address settings.
- Heating function not working: Check the heating function settings in the APP. Ensure the heating circuit is correctly wired and any external temperature control switches are functioning properly.
- Display not showing information: Verify the display cable is securely connected to the BMS interface. Check for power to the display.
For more complex issues, refer to the detailed troubleshooting guides in the full PDF manual or contact JIKONG customer support.
8. User Tips
Based on general best practices for Battery Management Systems, here are some tips for optimal use:
- Careful Wiring: Always double-check all wiring connections, especially the balance leads and main power connections (B- and P-), before applying power to avoid damage. Incorrect wiring is a common cause of issues.
- APP Monitoring: Regularly use the mobile APP to monitor battery parameters and check for any alerts or protection activations. This helps in proactive maintenance and understanding battery health, allowing you to address minor issues before they become major problems.
- Parameter Customization: Take advantage of the APP's parameter setting capabilities to fine-tune protection thresholds and balancing currents according to your specific battery chemistry and usage patterns. Proper configuration can significantly extend battery life and performance.
9. Maintenance
To ensure the long-term reliability and performance of your JIKONG BMS, follow these maintenance guidelines:
- Regular Inspection: Periodically inspect all wiring and connections for signs of wear, corrosion, or looseness. Ensure the BMS board is securely mounted and free from physical damage.
- Software Updates: Check for and install any available firmware updates for the BMS and updates for the mobile APP to benefit from improved features, performance enhancements, and bug fixes.
- Cleaning: Keep the BMS and its connections clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using liquids or abrasive cleaners that could damage components.
- Environmental Conditions: Ensure the BMS operates within its specified temperature range (-30°C to 70°C) and in a dry, well-ventilated environment to prevent overheating or moisture damage.
- Battery Health Monitoring: Regularly monitor individual cell voltages and overall battery health via the APP. Address any imbalances or anomalies promptly to maintain optimal battery performance and lifespan.
10. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact JIKONG Official Store directly. Keep your purchase receipt as proof of purchase.
JIKONG Technology Co., Ltd. is committed to providing high-quality products and excellent customer service. They have a strong R&D team and adhere to strict quality standards, being ISO9001 certified.