1. Introduction
The AOKIN DC-DC Buck Boost Converter Module ZK-SJUA-4X U2 is a versatile power module designed for precise voltage and current regulation. It features an integrated LCD digital display for real-time monitoring of input voltage, output voltage, output current, and output power. This module can efficiently step up (boost) or step down (buck) DC voltages, making it suitable for a wide range of electronic projects and applications.
Key features include:
- Wide Input/Output Range: Input voltage from DC 5.5-30V, adjustable output from DC 0.5-30V.
- Adjustable Current: Output current adjustable up to 4A (with enhanced heat dissipation).
- Power Capability: Up to 35W with natural heat dissipation, and up to 50W with enhanced heat dissipation.
- Digital Display: LCD shows input/output voltage, current, and power with high resolution.
- Safety Features: Includes input anti-reverse connection protection, output anti-backflow, and short-circuit protection.

2. Specifications
| Parameter | Value |
|---|---|
| Input Voltage | DC 5.5-30V (Undervoltage protection below 4.7V) |
| Output Voltage | DC 0.5-30V |
| Output Current | 3A (long-term stable operation), 4A (with enhanced heat dissipation) |
| Output Power | 35W (natural heat dissipation), 50W (enhanced heat dissipation) |
| Voltage Display Resolution | 0.01V |
| Current Display Resolution | 0.002A |
| Conversion Efficiency | Around 88% |
| Soft Start | Yes (potential for failure with high power/load startup) |
| Input Reverse Protection | Yes |
| Output Anti-Backflow | Yes |
| Short Circuit Protection | Yes |
| Operating Frequency | 180KHz |
| Dimensions (L*W*H) | 66 * 48 * 21mm |
| Installation Hole Diameter | 4mm |
| Weight | 46g |
3. Setup and Wiring
Careful wiring is essential for proper and safe operation. Refer to the diagram below for correct connections.

3.1. Wiring Instructions
- Connect your DC power source to the IN+ (positive input) and IN- (negative input) terminals. Ensure correct polarity.
- Connect your load (e.g., battery, LED, device) to the OUT+ (positive output) and OUT- (negative output) terminals. Ensure correct polarity.
- Important: Do not short-circuit the input (IN) with the output (OUT) terminals, as this will cause the constant current function to fail.
- Ensure that the power capacity of your input power supply is always greater than the power required by your output load.
- If your input power supply does not have output current limiting protection, it is recommended to connect a fuse in series at the input of the module to enhance safety.
3.2. Initial Assembly
The module may come with a separate heatsink and standoffs. Attach the heatsink to the main chip for improved thermal performance, especially when operating at higher currents or power levels. Use the provided standoffs for mounting the module securely.

4. Operating Instructions
The module features two buttons and two potentiometers for control and adjustment.
4.1. Button Functions
- IN/OUT Button:
- Short Press: Switches the LCD display between input voltage and output voltage.
- Long Press: Switches the LCD display between output current and output power.
- ON/OFF Button:
- Short Press: Toggles the output ON or OFF.
- Long Press: Sets the default output state (ON or OFF) for the next power-on cycle.
4.2. Potentiometer Functions
There are two potentiometers on the module for fine-tuning voltage and current:
- CC (Constant Current) Potentiometer: Used for current setting. Rotate clockwise to increase the set current. When the load current reaches the set current, the module enters a constant current state, and the red CC indicator light illuminates.
- CV (Constant Voltage) Potentiometer: Used for voltage setting. Rotate clockwise to increase the output voltage. The green ON indicator light illuminates when there is voltage at the output terminal.

4.3. Usage Methods
4.3.1. As a Regular Boost/Buck Module with Overcurrent Protection
- Set Output Voltage (CV): Adjust the CV (constant voltage) potentiometer to achieve your desired output voltage.
- Set Overcurrent Protection (CC):
- Measure the output short-circuit current using a multimeter in 10A current mode (connect probes directly to output terminals).
- Adjust the CC (constant current) potentiometer to set the desired overcurrent protection value. For example, if you set it to 2A, the module will limit the output current to 2A. The red CC indicator light will turn on when the current limit is reached.
- Note: When operating in constant current mode, a voltage drop of 0-0.2V may occur across the internal sampling resistor. High currents can also cause a slight voltage drop across input/output wires.
4.3.2. As a Battery Charger
This module can be used to charge various rechargeable batteries, providing both constant current (CC) and constant voltage (CV) charging stages.
- Determine Battery Parameters: Identify the float charging voltage and maximum charging current for your battery (e.g., for a 3.7V/2200mAh lithium battery, float voltage is 4.2V, max current is 2.2A).
- Set Float Charging Voltage (CV): Under no-load conditions (output disconnected), adjust the CV potentiometer to set the float charging voltage.
- Set Charging Current (CC): Under no-load conditions, measure the output short-circuit current with a multimeter in 10A mode. Adjust the CC potentiometer to set the desired charging current.
- Connect and Charge: Connect the battery to the output terminals and begin charging.
4.3.3. As a High-Power LED Constant Current Driver
- Determine LED Parameters: Identify the operating current and maximum operating voltage required for your LED(s).
- Set Maximum Operating Voltage (CV): Under no-load conditions, adjust the CV potentiometer to set the maximum operating voltage for the LED(s).
- Set LED Operating Current (CC): Under no-load conditions, measure the output short-circuit current with a multimeter in 10A mode. Adjust the CC potentiometer to set the desired LED operating current.
- Connect and Test: Connect the LED(s) to the output terminals and test the setup.
5. Maintenance and Heat Dissipation
To ensure long-term stable operation and prevent damage, proper heat management is crucial, especially when operating at higher power levels.
- Heat Dissipation: When using the module with power exceeding 3A or 35W, it is essential to strengthen heat dissipation. This may involve attaching the provided heatsink, adding a larger heatsink, or incorporating active cooling (e.g., a fan).
- Heatsink Placement: Ensure the heatsink is securely attached to the main power components. If the module is mounted vertically, verify that the heatsink cannot slide off and short-circuit other components or the display.
- Cleanliness: Keep the module free from dust and debris to maintain optimal cooling and prevent short circuits.
6. Troubleshooting
- No Output / Module Shuts Off: The module is equipped with output short-circuit protection. If a short circuit occurs, the module will automatically shut off the output. To restore operation, power cycle the module (turn it off and on again).
- Voltmeter/Ammeter Failure at Low Input Voltage: If the input voltage is 5V, the output power is limited to approximately 15W, and the integrated voltmeter and ammeter may not function accurately or at all. For full load output, the input voltage should be above 8V.
- Constant Current Function Failure: This can occur if the input (IN) and output (OUT) terminals are accidentally short-circuited. Ensure correct wiring as per the setup instructions.
- Inaccurate Current Reading at Low Values: Some users report that the current display may be unstable or inaccurate below 100mA (e.g., below 0.06A). This may be a limitation of the built-in ammeter.
7. User Tips
- Display Accuracy: The voltage and current displays are generally accurate when compared to multimeters, but minor discrepancies (e.g., +0.1V on input voltage) may occur.
- Heat Management: For sustained high-current or high-power applications, consider adding a larger heatsink or active cooling (fan) to prevent overheating, as the standard heatsink can get very hot.
- Low Input Voltage: While the module specifies a minimum input of 5.5V, some users have successfully operated it with lower input voltages (e.g., 4.2V from an 18650 battery) for stable output, though the display might be affected.
- Potentiometer Identification: The potentiometers are typically labeled 'CC' for current control and 'CV' for voltage control. One user noted 'W102' for CC and 'W503' for CV.
- Smooth Regulation: The module offers smooth regulation for both voltage and current, making it suitable for sensitive applications.
8. Warranty and Support
For detailed information regarding warranty, returns, or technical support, please refer to the official product documentation or contact the seller directly.
An electronic version of the user manual (PDF) is available for download: View User Manual (PDF)