1. Introduction and Overview
This manual provides detailed instructions for the VEVOR Hybrid Solar Inverter, available in 3500W (EML3500-24L) and 5500W (EM5500-48L) models. This 2-in-1 device integrates an inverter and a solar charge controller, delivering a pure sine wave output suitable for various off-grid solar PV system applications. It supports multiple battery types and offers advanced MPPT charging technology for high efficiency. The inverter also functions as an Uninterruptible Power Supply (UPS), ensuring continuous power during outages.

2. Safety Information
Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.
- Installation should be performed by qualified personnel only.
- Ensure all wiring is correctly sized and properly insulated.
- Do not attempt to disassemble or repair the inverter yourself. Contact qualified service personnel.
- Keep the inverter away from flammable materials, moisture, and direct sunlight.
- Ensure adequate ventilation around the inverter to prevent overheating.
- Always disconnect power before performing any maintenance or wiring.
- This device contains high voltage. Exercise extreme caution.
3. Product Features
- 2-in-1 Hybrid Design: Seamlessly integrates an inverter and a solar charge controller for efficient power management.
- Pure Sine Wave Output: Provides stable and clean power suitable for sensitive electronics.
- High Efficiency MPPT Technology: Achieves up to 96% solar energy conversion efficiency.
- Versatile Battery Compatibility: Supports 24V or 48V battery systems, including Lead-Acid, Lithium-Ion, and Lithium Iron Phosphate (LiFePO4) batteries.
- Lithium Battery Activation & BMS Communication: Features RS232/RS485 interfaces for smart battery management.
- Multi-layered Protection: Includes over-temperature, over-current, over-voltage, under-voltage, short circuit, and over-load protection.
- Multiple Charging Modes: Offers Solar Charging, Utility Charging, and Hybrid Charging options.
- Multiple Load Output Modes: Features UTL (Utility priority), SOL (Solar priority), SBU (Solar-Battery-Utility), and SUB (Solar-Utility-Battery) modes.
- UPS Functionality: Automatically switches to backup power during outages for uninterrupted operation.
- Intuitive LCD Panel: Allows effortless monitoring of system status, parameters, and fault indications.
- Wide Application: Suitable for home, commercial, RV, and camping power needs.


4. Specifications
Note: Specifications may vary slightly between the 3500W and 5500W models. Refer to the specific model details below.
| Parameter | 3500W Model (EML3500-24L) | 5500W Model (EM5500-48L) |
|---|---|---|
| Brand Name | VEVOR | VEVOR |
| Item Model Number | EML3500-24L | EM5500-48L |
| Rated Power | 3500W ±10% | 5500W ±10% |
| Input Voltage | 220/230V AC | 220/230V AC |
| Output Voltage | AC 230V, 50 Hz | AC 230V, 50 Hz |
| Output Waveform | Pure Sine Wave | Pure Sine Wave |
| Inverter Response Time | 10 ms (UPS); 20 ms (appliance) | 10 ms (UPS); 20 ms (appliance) |
| Battery Type | 24V, Lead-Acid, Lithium, LiFePO4, NMC | 48V, Lead-Acid, Lithium, LiFePO4, NMC |
| Max. Charging Current | 60A(PV)/80A(AC)/120A(PV+AC) | 100A(PV)/80A(AC)/100A(PV+AC) |
| PV Array MPPT Voltage Range | 30-160V DC | 500V DC |
| No-load Self-consumption | Less than 20W | Less than 20W |
| Product Dimensions (L x W x H) | 14.4 x 12.2 x 4.2 in (365 x 310 x 107 mm) | 17.5 x 12.3 x 4.2 in (445 x 313 x 107 mm) |
| Net Weight | 13.7 lbs / 6.2 kg | 18.4 lbs / 8.35 kg |


5. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your VEVOR Hybrid Solar Inverter. It is highly recommended that installation be performed by a certified electrician or solar professional.
5.1 Site Selection
- Install the inverter in a cool, dry, and well-ventilated area.
- Avoid direct sunlight, high temperatures, and high humidity.
- Ensure sufficient clearance around the inverter for proper airflow.
- Mount the inverter vertically on a non-flammable surface.
5.2 Wiring Diagram Overview
The inverter supports connections for solar panels (PV array), batteries, AC utility input, and AC load output. The following diagram illustrates a typical setup for a solar AC power system.

- Solar Charging: Connect your PV array to the designated solar input terminals. Ensure the PV array MPPT voltage range and maximum power are within the inverter's specifications (e.g., 30-160VDC for 3500W model, 500VDC for 5500W model).
- Battery Connection: Connect the appropriate 24V or 48V battery bank (Lead-Acid, LiFePO4, or NMC) to the battery terminals. Observe correct polarity.
- AC Charging (Utility/Generator): Connect the AC utility grid or a generator to the AC input terminals.
- AC Output: Connect your AC loads (appliances) to the AC output terminals. Ensure the total power consumption does not exceed the inverter's rated output (e.g., ≤ 3500W for 3500W model).
- Communication Ports: Utilize the RS232/RS485 communication ports for monitoring and BMS integration with compatible lithium batteries.
Always consult the detailed wiring diagrams and safety guidelines provided in the complete product manual for your specific model before making any connections.
6. Operating Instructions
6.1 Initial Power-Up
- After all connections are securely made and verified, switch on the battery breaker first.
- Then, switch on the solar array breaker (if applicable).
- Finally, switch on the AC input breaker (if applicable).
- The inverter's LCD screen will power on and display system status.
6.2 LCD Display and Navigation
The multi-functional LCD panel provides real-time system data and allows for configuration of operating parameters. Use the physical buttons to navigate through menus and adjust settings.
- Input Information: Displays AC input voltage, frequency, and solar input voltage.
- Output Information: Shows AC output voltage, frequency, and load percentage.
- Charging/Discharging Priority: Allows selection of preferred charging source (solar, utility, or hybrid) and discharge priority.
- Battery Information: Displays battery voltage, charge current, and state of charge.
- Fault Indication: Alerts to any system errors or warnings.
6.3 Charging Modes
The inverter offers three primary charging modes:
- Solar Charging: Prioritizes charging the battery from solar panels.
- Utility Charging: Charges the battery from the AC utility grid.
- Hybrid Charging: Utilizes both solar and utility power to charge the battery, optimizing charging efficiency.
6.4 Load Output Modes
The inverter supports four load output modes to manage power delivery to your appliances:
- UTL Mode (Utility Priority): The inverter primarily draws power from the utility grid to supply loads. Solar power is used to charge batteries.
- SOL Mode (Solar Priority): Loads are primarily powered by solar energy. If solar is insufficient, battery power is used. Utility power is a last resort.
- SBU Mode (Solar-Battery-Utility): Loads are powered by solar, then battery. If both are insufficient, the utility grid provides power.
- SUB Mode (Solar-Utility-Battery): Loads are powered by solar, then utility. If both are insufficient, battery power is used.

6.5 Lithium Battery Activation
The inverter features automatic lithium battery activation. When a compatible lithium battery runs out, the inverter can automatically activate and charge it, eliminating the need for manual intervention. This feature works in conjunction with the RS232/RS485 communication ports for BMS integration.

7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Connection Checks: Annually inspect all wiring connections (solar, battery, AC input/output) to ensure they are tight and free from corrosion.
- Battery Health: Monitor battery voltage and performance regularly. Follow the battery manufacturer's maintenance guidelines.
- Environmental Check: Ensure the installation environment remains cool, dry, and well-ventilated.
- Firmware Updates: Check the manufacturer's website for any available firmware updates for improved performance or new features.
Always disconnect all power sources before performing any maintenance.
8. Troubleshooting
If you encounter issues with your VEVOR Hybrid Solar Inverter, refer to the following basic troubleshooting steps. For complex problems, contact customer support or a qualified technician.
- No Power Output:
- Check all circuit breakers and fuses (AC input, battery, solar).
- Verify battery connections and voltage.
- Ensure solar panels are receiving adequate sunlight and are connected correctly.
- Check for any fault codes on the LCD display.
- Inverter Overheating:
- Ensure adequate ventilation around the unit.
- Check if the fan is operating.
- Reduce the load connected to the inverter.
- Clean any dust or obstructions from the ventilation openings.
- Battery Not Charging:
- Verify solar panel connections and output.
- Check AC input connection if using utility charging.
- Ensure battery type settings on the inverter match your battery.
- Check for any fault codes related to charging.
- Unusual Noises:
- A slight hum is normal. Loud or unusual noises may indicate a problem.
- Disconnect power and inspect for loose components or foreign objects.
Always refer to the fault codes and detailed troubleshooting guide in the complete product manual.
9. User Tips
Based on common user experiences and questions, here are some tips for optimizing your inverter's performance:
- Battery Matching: Ensure your battery bank voltage (24V or 48V) perfectly matches the inverter model you purchased. Incorrect voltage can lead to damage.
- Load Management: Avoid consistently running the inverter at its maximum rated power. Leave some headroom for optimal efficiency and longevity.
- Monitoring: Regularly check the LCD display for system status and any warning messages. Early detection of issues can prevent larger problems.
- Professional Installation: While the manual provides guidance, for complex setups or if you are unsure, always opt for professional installation to ensure safety and compliance with local electrical codes.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact VEVOR customer service or your authorized dealer. Keep your purchase receipt and product model number handy when contacting support.
Manufacturer: VEVOR
Website: Refer to your product packaging or official VEVOR documentation for the most current support contact information.