1. Introduction
The Hantek 6074BC/BD/BE series digital storage oscilloscopes are compact, lightweight, and portable devices that do not require an external power supply. They are widely used in engineering measurements, field work, research, design, education, and training, including virtual circuit measurement and fault diagnosis.
This manual provides essential information for setting up and operating your oscilloscope.
Video: Hantek 6074BC/BD/BE Product Overview
2. Safety Information
Please read the following safety precautions carefully to avoid injury and prevent damage to this product or any connected products. To prevent potential hazards, use this product only as specified. Only professionally authorized personnel should perform repairs.
Prevent Fire or Personal Injury:
- Use the Correct Power Cord: Use only the power cord specified for this product and approved in your country.
- Proper Connection and Disconnection: Before connecting the probe to the circuit under test, connect the probe to the oscilloscope. Before disconnecting the probe from the oscilloscope, disconnect the probe from the circuit under test.
- Ground the Product: To prevent electric shock, this product must be grounded through the grounding conductor of the power cord. The grounding conductor must be connected to ground before connecting the product's input or output terminals.
- Proper Probe Connection: The probe ground wire has the same potential as ground. Do not connect the ground wire to high voltage.
- Check All Terminal Ratings: To prevent fire or excessive current shock, check all terminal ratings and markings on the product. Refer to the product manual for detailed information on ratings before connecting the product.
- Do Not Operate with Covers Open: Do not operate this product with the covers or panels open.
- Avoid Exposed Circuits: Do not touch exposed terminals and components when power is on.
- Do Not Operate if Product is Faulty: If you suspect this product is damaged, do not operate it. Have it inspected by qualified service personnel.
- Maintain Proper Ventilation: Ensure adequate ventilation around the device.
- Do Not Operate in Wet Conditions: Avoid using the device in damp or wet environments.
- Do Not Operate in Explosive Atmospheres: Do not use the device in flammable or explosive environments.
- Keep Product Surfaces Clean and Dry: Regularly clean and dry the product surfaces.
3. System Requirements
To run the oscilloscope software, your system must meet the following requirements:
Minimum System Requirements:
- Operating System: Windows XP/Vista/Win7
- Processor: 1.00 GHz or higher
- Memory: 256 MB RAM
- Hard Drive: 500 MB free disk space
- Screen Resolution: 800 x 600
Recommended Configuration:
- Operating System: Windows XP SP3 System
- Processor: 2.4 GHz Processor
- Memory: 1 GB RAM
- Hard Drive: 80 GB Disk Space
- Screen Resolution: 1024 x 768 or 1280 x 1024
- DPI Setting: Normal Size (96DPI)
4. Installation
4.1 Software Installation
Before using the oscilloscope, you must install the software.
- Insert the provided CD into your computer's CD drive.
- The installation should start automatically. If not, open Windows Explorer, navigate to the CD drive, and run
Setup.exe. - Follow the on-screen prompts. Click "Next" to proceed with the installation.
- Select the destination directory for the software installation and click "Next".
- Confirm the installation and allow the setup wizard to copy the driver files.
- The system settings will be updated.
4.2 Driver Installation
For Hantek 6000B series (e.g., Hantek 6074BC/BD/BE):
- Connect the Type-A USB plug to a USB port on your computer.
- Connect the other Type-A USB plug to the oscilloscope's USB port.
- The hardware USB device will be detected. If the driver installation fails, proceed to the next step.
- Right-click "My Computer" and select "Manage" to enter Device Manager.
- In Device Manager, right-click the device model (e.g., "DSO Device" under "Other devices") and select "Update Driver Software...".
- Choose "Browse my computer for driver software".
- Specify the correct driver path (e.g.,
C:\Users\Administrator\Desktop\DSO-6000_Ver1.0.20_D20160305\Driver) and click "Next" to continue the installation. - When prompted by Windows Security, click "Install this driver software anyway" to proceed.
- The driver software will then install.
- Once the driver is successfully installed, the device will appear correctly in Device Manager under "Hantek6000B".
5. Basic Features
The Hantek 6074BC/BD/BE series oscilloscopes offer a range of powerful features:
- Four Channels: Up to 250MHz bandwidth.
- Max Real-time Sampling Rate: 1GSa/s.
- Memory Depth: 64K/CH.
- Automatic Setup (AUTOSET): Quickly optimizes display settings.
- Fast Fourier Transform (FFT): For spectrum analysis.
- 20 Automatic Measurements: Provides various waveform parameters.
- Cursor Measurements: For precise manual measurements.
- Waveform Storage: Record and replay dynamic waveforms.
- Self-Calibration: Ensures optimal measurement accuracy.
- Mathematical Operations: Add, subtract, multiply, and divide waveforms.
- 20 MHz Bandwidth Limit: Filters out high-frequency noise.
- Waveform Averaging: Reduces random noise for clearer signals.
- Adjustable Waveform Clarity: Enhances display quality.
- Multi-language Support: Software available in multiple languages.

Image: Key features including 4 analog channels, 1GSa/s sampling, 2mV-10V/DIV input sensitivity, 70MHz-250MHz bandwidth, USB2.0 interface, Windows software support, FFT spectrum analyzer, 20 automatic measurement functions. Also highlights heat resistance, anodized aluminum, abrasive resistance, and dimensions (207mm x 123mm x 37mm).
6. Operation
6.1 General Inspection
Upon receiving your oscilloscope, follow these steps:
- Inspect for Shipping Damage: If the packaging or foam protection is severely damaged, retain it until the instrument and accessories have passed electrical and mechanical tests.
- Check Accessories: Refer to the "Accessories" section in Appendix B of this manual for a detailed list. Check for any missing or damaged accessories. If any are missing or damaged, contact your dealer.
- Inspect the Instrument: If the instrument appears damaged, is not functioning correctly, or fails performance tests, contact your dealer. If damage occurred during shipping, retain the packaging and notify the shipping department and your dealer.
6.2 Probe Compensation
When connecting a probe to any input channel for the first time, it needs to be compensated to match the channel. An uncompensated or improperly compensated probe will lead to measurement errors.
- Set the software to X10. Set the probe attenuation factor to X10 and connect the probe to CH1. If using a hook probe, ensure good contact between the probe and CH1. Connect the probe tip to the probe compensation signal output and the ground clip to the probe compensation ground.
- Check the waveform shape to determine if the probe compensation is correct. Open CH1 and press the "AUTO" button.
- Adjust the variable capacitor on the probe with a non-metallic screwdriver until the waveform displayed on the screen is a perfect square wave.
- Repeat if necessary.
Warning: To avoid electric shock when using the probe, ensure the insulation wire of the probe is intact. Do not touch the metal parts of the probe when connecting to high voltage sources.
6.3 Function Check
Perform a function check to ensure the oscilloscope is working correctly.
Connecting the Oscilloscope
Connect one end of the USB cable (Type-A plug) to your computer's USB port and the other end (Type-A plug) to the oscilloscope's USB port.

Image: Front view of the oscilloscope showing CH1, CH2, CH3, CH4 BNC input connectors.

Image: Side view of the oscilloscope showing the 5V==1A USB port, PRG button, USBXI port, and GEN OUT BNC connector.
Inputting a Signal to an Oscilloscope Channel
The oscilloscope has four channels. Follow these steps to input a signal:
- Push the probe's sliding switch to the X10 position and connect the probe to the oscilloscope's CH1 channel.
- Set the oscilloscope probe attenuation factor to X10 (default is X1).
- Connect the probe tip and ground clip to the probe compensation terminal on the oscilloscope. Click the "AUTO" button and wait a moment. A square wave signal with a frequency of 1KHz and peak-to-peak voltage of 2V should be displayed on the screen.
- Repeat steps 2 and 3 for channels CH2, CH3, and CH4 using the same method.
6.4 User Interface Overview
The software's main interface integrates various settings and controls for waveforms:
- System Main Menu: Contains most software settings.
- Toolbar: Quick access to common functions.
- Trigger Information: Displays trigger mode, source, and level.
- Horizontal System Control Panel: Configures time base and waveform display mode.
- Vertical System Control Panel: Turns CH1/CH2/CH3/CH4 channels on/off and sets voltage and probe attenuation.
- Trigger System Control Panel: Sets trigger mode, type, source, and edge type.
- System Time: Displays current time.
- Trigger Level: Indicates the trigger voltage level.
- Time Base Setting Information: Shows current time base settings.
- Channel CH1/CH2/CH3/CH4 Information: Displays channel coupling, vertical voltage scale, and bandwidth limit status.
- Status Information: Shows connection status (Connected, Analog, Searching Device).
- CH1/CH2/CH3/CH4 Vertical Zero Level Marker: Indicates the zero voltage level for each channel.
- Horizontal Trigger Position: Shows the trigger position on the horizontal axis.
- Trigger Status: AUTO (automatic trigger), Trig'D (triggered), STOP (stopped acquisition), RUN (acquiring data).
- DDS Control Panel (HANTEK 6000BD): For signal generator functions.
6.5 Menu System
The main menu bar provides access to various functions:
- File (F): Load/save data, configurations, and images. Print and exit.
- View (V): Change user interface elements (toolbar, status bar, sidebar).
- Settings (S): Access REF, MATH, Trigger System, Vertical System, and Horizontal System settings.
- Display (D): Change waveform display type (vector, dot), grid, brightness, and grid background color.
- Cursor (C): Set cursor measurement type (cross, trace, horizontal, vertical) and source.
- Measure (M): Configure measurement parameters (source, voltage, time, clear, options).
- Acquire (A): Run, pause, zoom in/out, memory length, acquisition mode, interpolation mode, auto setup.
- Auxiliary (U): Access test functions, frequency counter, self-calibration, factory settings, and language.
- Window (W): Arrange windows (cascade, tile, arrange icons).
- Help (H): Open help files.
6.6 Input Connections
The oscilloscope features several input and output connectors:
- CH1/CH2/CH3/CH4: Waveform data input ports (BNC connectors).
- GND: Ground terminal.
- USB PORT: USB input port (for connecting to PC).
- CAL: Probe compensation output.
7. Measurement Functions
7.1 Setting Oscilloscope Parameters
Use the "Auto Setup" function to display signals. This function automatically adjusts vertical range, horizontal time base, and trigger settings to obtain a stable waveform. It can also display basic measurement results based on the signal type.
Saving and Loading Settings
- The system automatically saves current software settings when you close the oscilloscope software.
- You can manually save current settings to a file via the "File" menu -> "Save Settings".
- Load previously saved settings via "File" menu -> "Load Settings".
- Restore factory default settings via "Auxiliary" menu -> "Factory Settings".
7.2 Vertical System Settings
Access vertical system parameters by clicking "Settings" -> "Vertical System".
- Channel Selection: Select the desired channel (CH1-CH4).
- On/Off: Enable or disable the selected channel.
- Volts/Div: Set the vertical voltage scale.
- Coupling: Set the coupling mode (AC, DC, Ground). AC coupling blocks DC components, DC coupling shows both AC and DC, Ground disconnects the input.
- Probe: Set the probe attenuation factor (e.g., x1, x10).
- BW Limit: Enable/disable 20MHz bandwidth limit to filter high-frequency components.
- Invert: Invert the selected channel's waveform.
7.3 MATH Channel Settings
Access MATH channel settings by clicking "Settings" -> "MATH".
- On/Off: Enable or disable the MATH channel.
- Source A/B: Set the input sources for mathematical operations.
- Operation: Select the mathematical operation (A+B, A-B, A*B, A/B, FFT).
- Volts/Div: Set the vertical resolution for the MATH channel.
- Invert: Invert the MATH channel waveform.
- FFT: Transforms time-domain signals into frequency-domain signals (spectrum).
7.4 REF Channel Settings
Access REF channel settings by clicking "Settings" -> "REF".
- On/Off: Enable or disable the REF channel.
- Volts/Div: Adjust the vertical resolution for the REF channel.
- Load: Load a reference waveform (.rfc file) from your computer.
- Save: Save the current reference waveform as a .rfc file.
7.5 Horizontal System Settings
Access horizontal system parameters by clicking "Settings" -> "Horizontal System".
- Time Base (Sec/Div): Set the horizontal time scale.
- Format: Set the horizontal display format (Y-T, X-Y).
- Y-T Mode: Displays vertical voltage against time.
- X-Y Mode: Displays CH1 (X-axis) against CH2 (Y-axis), useful for phase analysis (Lissajous figures).
- Horizontal Position: Adjusts the horizontal position of the waveform. Double-clicking the icon resets it to the center.
7.6 Trigger System Settings
Access trigger system parameters by clicking "Settings" -> "Trigger System".
- Trigger Mode: Select the trigger mode (Edge, Pulse, Video, Alternative).
- Trigger Type: Select trigger type (Auto, Normal, Single).
- Trigger Source: Select the channel that triggers the acquisition (CH1-CH4).
- Edge Type: Select rising edge (+) or falling edge (-) for edge triggering.
- Pulse Width Trigger: Triggers based on pulse width.
- Video Trigger: Triggers on video signals (NTSC, PAL, SECAM standards).
- Alternative Trigger: Allows triggering on two different channels.
- HF Rejection: Suppresses high-frequency components (above 20MHz) from the trigger signal.
7.7 Signal Generator (Hantek 6000BD only)
The Hantek 6000BD model includes a signal generator. You can generate various waveforms (sine, square, triangle, ramp, Gaussian, arbitrary, exponential, white noise) and adjust their parameters.
- On/Off: Enable or disable waveform output.
- Waveform Type: Select the desired waveform (Sine, Square, Triangle, Ramp, Gaussian, Arbitrary, Exponential, White Noise).
- Frequency: Set the output frequency.
- Amplitude: Set the peak-to-peak voltage.
- Y-axis Offset: Set the DC offset.
- Phase: Set the phase of the waveform.
- Duty Cycle: For square and triangle waves, adjust the duty cycle.
- Rise/Fall Edge: For ramp waves, adjust the rise and fall edge times.
8. Specifications
| Category | Parameter | Value |
|---|---|---|
| Vertical System | Analog Channels | 4 |
| Bandwidth | 70MHz (-3dB) | |
| Input Impedance | 1MΩ ±25pF | |
| Input Sensitivity | 2mV/div to 10V/div | |
| Input Coupling | AC/DC/GND | |
| Vertical Resolution | 8 bits | |
| Memory Depth | 64K/CH | |
| Horizontal System | Real-time Sampling Rate | 1GSa/s |
| Time Base Range | 2ns/div to 1000s/div | |
| Time Base Precision | ±50ppm | |
| Trigger System | Trigger Source | CH1, CH2, CH3, CH4 |
| Trigger Mode | Edge, Pulse, Video, Alternative | |
| X-Y Mode Phase Shift | Max 3 degrees | |
| Measurements | Auto Measurements | Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle |
| Cursor Measurements | Cross, Trace, Horizontal, Vertical | |
| Waveform Process | +, -, x, ÷, FFT, Invert | |
| Physical | Dimensions | 175mm * 105mm * 30mm |
| Weight | 0.9KG | |
| Connectivity | Interface | USB 2.0 (Dual Port USB) |
| Software | OS Support | Windows 7, Windows 8, Windows 10 |
9. Maintenance
9.1 Daily Maintenance
- Do not store the instrument in damp places or expose it to direct sunlight for extended periods.
9.2 Cleaning
Warning: To avoid damaging the instrument or probes, do not use corrosive agents or chemical cleaners. Do not allow sprays, liquids, or solvents to get on the instrument or probes.
Regularly inspect the instrument and probes based on operating conditions. Follow these steps to clean the exterior of the instrument:
- Use a soft cloth to wipe dust from the exterior of the instrument and probes.
- Use a soft cloth dampened with water to clean the instrument, ensuring the power is disconnected.
10. Troubleshooting
If you encounter issues with your Hantek oscilloscope, consider the following general troubleshooting steps:
- Software Not Launching: Ensure all system requirements are met and the software is installed correctly. Try reinstalling the software and drivers.
- Device Not Detected: Verify that the USB cable is securely connected to both the oscilloscope and the computer. Check Device Manager to ensure the driver is installed correctly and the device is recognized. Try a different USB port or cable.
- No Waveform Display: Check that the probes are correctly connected to the input channels and the circuit under test. Ensure the channels are enabled in the software. Use the "Auto Setup" function to automatically adjust display settings.
- Unstable Waveform: Adjust the trigger settings (mode, source, level, edge type) to stabilize the waveform. Perform probe compensation if the waveform appears distorted.
- Measurement Inaccuracies: Ensure probes are properly compensated. Check the vertical and horizontal scale settings. Perform self-calibration if the environment temperature has changed significantly.
- Software Freezing/Crashing: Ensure your operating system is up to date. Close other demanding applications. Reinstall the software if the issue persists.
For more detailed troubleshooting, refer to the official Hantek support resources or contact their customer service.
11. User Tips
- Regular Self-Calibration: Perform self-calibration if the ambient temperature changes by more than 5°C to maintain measurement accuracy. Allow the oscilloscope to warm up for 20 minutes before calibration.
- Proper Probe Handling: Always connect the probe to the oscilloscope first, then to the circuit. Disconnect from the circuit first, then from the oscilloscope.
- Utilize Auto Setup: For quick signal acquisition, the "Auto Setup" function is very effective in automatically adjusting the display and trigger settings.
- Software Updates: Keep your oscilloscope software updated to benefit from the latest features and bug fixes.
- Data Export: Use the data export functions (EXCEL, BMP, JPG) to save and analyze waveform data for documentation or further processing.
12. Support & Documentation
For further assistance, technical support, or to access the latest documentation, please visit the official Hantek website at www.hantek.com.
A detailed user manual in PDF format is available for download. You can view it here: User manual (PDF).