1. Introduction
The Sunster 12V/24V Electric Parking Air Conditioner is an in-car air conditioning system designed to provide continuous cooling when your vehicle is parked or the engine is off. It operates using the vehicle's onboard DC power supply (12V or 24V), ensuring comfort for truck drivers and other vehicle occupants without needing the engine to run. This system is energy-saving, operates quietly, and features intelligent low-voltage protection to safeguard your battery.
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Sunster Electric Parking Air Conditioner.
Video: Sunster Electric Air Conditioner Product Demonstration
2. Safety Information
Please read all safety instructions carefully before installation and operation to prevent injury or damage to the unit.
- Electrical Safety: Ensure all electrical connections are secure and correctly wired according to the vehicle's electrical system. Incorrect wiring can lead to electrical shock, fire, or damage to the unit and vehicle.
- Refrigerant Handling: The air conditioner does not come pre-filled with refrigerant. Adding refrigerant (R1234yf or R134a) and refrigeration oil (POE68) should only be performed by qualified professionals. Improper handling of refrigerants can cause personal injury or environmental harm.
- Battery Safety: Adhere to the specified battery requirements (100AH for 12V, 80AH for 24V) and ensure your generator meets the minimum amperage (70A for 12V, 60A for 24V). Overloading the battery or generator can lead to system failure or fire.
- Ventilation: Ensure adequate ventilation around the external unit to prevent overheating and maintain optimal performance.
- Low-Voltage Protection: The unit features intelligent low-voltage protection to prevent excessive battery discharge. Do not bypass this feature.
3. Package Contents
Upon unpacking, please verify that all the following items are included:
- 1x 12V/24V Car Air Conditioner (Internal and External Units)
- 1x Internal Machine
- 1x Sewer Pipe
- 1x 3M High Pressure Pipe
- 1x 3M Low Pressure Pipe
- 1x Internal Machine Mounting Plate
- 1x Screw Bag
- 1x Adhesive Tape
- 1x Internal and External Signal Lines
- 1x 3M Battery Line
- 1x User Manual
- 1x Remote Control

Image: All components included in the package.
4. Specifications
The Sunster Electric Parking Air Conditioner is available in 12V and 24V versions. Please refer to the specific parameters for your model:
Common Specifications:
- Model Number: KF-32GW/URC
- Screen Display: LED display screen
- Power On Status: Default Last Shutdown Status
- Refrigerant: R1234yf / R134a (NOT INCLUDED)
- Fan Power: 80W
- Refrigeration Capacity: 1KW-3KW
- Air Volume: 150-500m³/h
- Operating Noise: <70dB
12V Product Parameters:
- Rated Voltage: DC 12±3V
- Drive Control: SP 4V-9V
24V Product Parameters:
- Rated Voltage: DC 24±4V
- Drive Control: SP 9V-19V

Image: Product parameters table.

Image: Overview of comfort modes, power levels, quiet operation (65dB), and stable temperature control (23°F).

Image: Energy efficiency graph illustrating power consumption (kWh/h) across Powerful, ECO Energy-Saving, and Sleep modes.
5. Setup and Installation
5.1 General Installation Notes
The Sunster Electric Parking Air Conditioner is designed for versatile installation in various vehicles, including trucks, RVs, agricultural vehicles, excavators, bulldozers, cranes, passenger cars, vans, light trucks, and construction vehicles. It offers multiple installation options, such as rooftop mounting for vans, commercial vehicles, and RVs, and back-wall mounting for trucks and tractors.

Image: Various vehicle types compatible with the air conditioner.

Image: Split-type parking AC external unit mounted on a truck.

Image: Main internal unit and external condenser unit with remote control.
5.2 Refrigerant and Oil Requirements
- The air conditioner is shipped without refrigerant. You must add 600g of R1234yf or R134a refrigerant.
- The required refrigeration oil type is POE68, which is included in the package.
- Before adding refrigerant, it is crucial to vacuum the system for 10 minutes until the low-pressure gauge shows a negative value. This ensures proper system function and prevents contamination.
5.3 Battery Requirements
- For 12V Systems: A single battery with at least 100AH capacity and a generator providing at least 70A are required.
- For 24V Systems: A single battery with at least 80AH capacity and a generator providing at least 60A are required.

Image: 12V AC outdoor unit parameters and application scenarios for trucks and RVs.
6. Operating Instructions
6.1 Control Panel Overview
The main control board features a temperature control air outlet input interface, a brush motor drive interface, an infrared remote control interface, an analog voltage signal output interface, and six mechanical buttons for direct control.

Image: Control panel diagram showing buttons for Power, Mode, Wind Speed, and Temperature adjustment.
6.2 Working Modes
The air conditioner offers several operating modes to suit different needs:
- Air Supply Mode: In this mode, the temperature cannot be adjusted, and the display shows the ambient temperature.
- Power Saving Mode: The compressor operates between 30% and 50% of its full speed. The voltage range for this mode is 10V-12V.
- Economic Mode: The compressor operates between 30% and 80% of its full speed. The temperature is set to 10°C, and the wind speed is adjustable to 3 levels. The output voltage varies between 10V and 16V. The panel starts in this mode by default.
- Strong Mode: The compressor operates between 30% and 100% of its full speed, with a voltage range of 10V-19V.
The temperature control probe is located on the evaporator surface at the air outlet. It protects the unit by shutting down if the temperature reaches 3°C. If the temperature sensor is disconnected or damaged, the panel will operate in sensorless mode, displaying only the set temperature and prompting an EC fault every three minutes, while adjusting the output signal to prevent frost.
6.3 Panel Function Buttons
- Power Button: Short press to turn ON. Long press for 3 seconds to turn OFF. To restore all settings to factory defaults, long press for 10 seconds while the unit is OFF.
- Wind Speed Key (+): Adjusts to increase air supply volume and increase the undervoltage protection value.
- Wind Speed Key (-): Adjusts to reduce air supply volume and reduce the undervoltage protection value.
- Mode Button: Long press for one second to switch between Air Supply, Power Saving, Economy, and Strong modes. Long press for 10 seconds to enter the adjustment state for undervoltage value and undervoltage recovery value. Changes will be automatically saved after 5 seconds.
- Temperature Plus Key (+): Adjusts the set temperature point to increase and increases the undervoltage protection recovery value by 0.1V.
- Temperature Minus Key (-): Adjusts the set temperature point to decrease and decreases the undervoltage protection recovery value by 0.1V.
6.4 Remote Control
The unit's LED display is complemented by a remote control for convenient operation. Use the remote to adjust settings from a distance.

Image: Remote control for adjusting air conditioner settings.

Image: Features including 360° adjustable air outlets, evaporator control panel with temperature display, and the remote control.
7. Maintenance
Regular maintenance ensures the longevity and efficient operation of your air conditioner.
- Power Disconnection: Always cut off the power supply to the unit before performing any cleaning or maintenance.
- Surface Cleaning: The surface of the air conditioner can be cleaned with a neutral cleaning agent and a soft cloth. Avoid abrasive cleaners or solvents.
- Dust Removal: Periodically remove the outer shell and use compressed air or a soft brush to blow out dust from the internal components, especially the fan and coils.
- System Checks: Regularly check the vehicle's battery power and ensure that the air inlet and outlet of the unit are not blocked, especially when the A/C unit is idle.
8. Troubleshooting
If your air conditioner experiences abnormal operation, refer to the following fault indications and solutions:
8.1 Fault Indications
When the panel detects a fault, it will stop working, the fault icon will flash, and a specific error code will be displayed on the digital tube. The meanings of these codes are:
- Undervoltage Protection: If the power supply voltage drops below the set value (default 21.3V), a red light will illuminate, the fan will stop, and the outdoor unit will enter standby mode. The system will automatically restart and resume operation once the voltage exceeds the undervoltage recovery value (default 25.5V).
- E-C: Temperature probe failure
- E-2: Controller operating circuit overload protection
- E-3: Controller stall protection
- E-4: Controller undervoltage protection
- E-5: Air conditioner does not cool (possible causes: lack of refrigerant, pipeline blockage, compressor damage)
- E-6: Outdoor fan failure
- E-7: Phase loss protection
- E-10: Electronic fan failure protection (requires controller replacement)
8.2 Low Power Battery
If the battery power is insufficient, the unit will enter low-voltage protection. While you can temporarily adjust the low-voltage protection settings and switch to energy-saving mode to extend operation time, it is highly recommended to charge the battery as soon as possible to prevent damage.
8.3 Abnormal Operation
If the A/C unit shows abnormal operation, check the error code displayed on the unit or the compressor's LED light. Refer to the corresponding meaning in this manual for guidance on how to address the issue.
9. User Tips
- Extended Use in Enclosed Spaces: For prolonged use in enclosed spaces (e.g., non-vehicle applications), consider using an additional dedicated battery to ensure continuous operation without draining your primary vehicle battery.
- External Unit Mounting: Ensure the external unit is mounted in a position that allows for optimal airflow and heat dissipation. Avoid mounting in locations where airflow is restricted or where it might be exposed to excessive debris or water.
- Refrigerant and Oil Checks: Regularly check the refrigerant and oil levels, especially if you notice a decrease in cooling performance. Professional assistance is recommended for these checks and refills.
10. Warranty and Support
For warranty information, technical assistance, or any questions not covered in this manual, please contact your retailer or visit the official Sunster website. A detailed user manual (PDF) is also available for download from the product page or by scanning the QR code provided with your purchase.
PDF Manual Reference: Sunster 12V Electric Air Conditioner User Manual (PDF)