1. Introduction
The Weintek cMT Gateway series offers robust and versatile solutions for industrial communication and data exchange. These gateways are designed to connect various industrial devices, facilitating data acquisition, remote monitoring, and control within an industrial automation environment. With different models offering varying connectivity options like Ethernet, Wi-Fi, and multiple COM ports, the cMT Gateway series provides flexibility for diverse application needs.

2. Model Overview
The cMT Gateway series includes several models, each tailored for specific connectivity and performance requirements:
- cMT-G01X: Features Ethernet connectivity and a Quad-core RISC processor.
- cMT-G02X: Includes Ethernet and Wi-Fi (IEEE 802.11 b/g/n) connectivity, powered by a Quad-core RISC processor.
- cMT-G03: Offers Ethernet and multiple COM ports (RS-232 2W, RS-485 2W/4W) with a Single-core RISC processor.
- cMT-G04: Provides LAN/10/100 Base-T x1, SW1, SW2:10/100 Base-T x1 (2 port Ethernet switch) and a Single-core RISC processor.

3. Setup and Installation
3.1 Mounting
The cMT Gateway units are designed for 35 mm DIN rail mounting. Ensure the mounting location is stable, free from excessive vibration, and within the specified environmental operating conditions.
3.2 Power Connection
Connect the gateway to a 24VDC power source. Observe the polarity indicated on the device (+ and - terminals). Ensure the power supply is stable and meets the gateway's power consumption requirements.
3.3 Network and Communication Connections
- Ethernet (LAN/SW1/SW2): Connect standard Ethernet cables to the appropriate ports for network communication.
- Wi-Fi (cMT-G02X only): Ensure the Wi-Fi antenna is securely attached for wireless communication.
- COM Ports (cMT-G03 only): Connect serial devices using RS-232 or RS-485 cables to the designated COM ports.
4. Operating Instructions
The Weintek cMT Gateway operates as a data exchange and communication hub. Configuration and management are typically performed using the EasyBuilder Pro software.
4.1 Initial Configuration with EasyBuilder Pro
- Install EasyBuilder Pro software on your PC.
- Connect your PC to the cMT Gateway via Ethernet.
- Launch EasyBuilder Pro and establish communication with the gateway.
- Configure network settings, communication protocols for connected devices (e.g., PLC, sensors), and data logging parameters as required by your application.
- Upload the project to the cMT Gateway.
4.2 Data Exchange and Monitoring
Once configured, the gateway will automatically collect data from connected devices, perform protocol conversions, and make data available for monitoring, logging, or transmission to other systems (e.g., SCADA, cloud platforms) as defined in your EasyBuilder Pro project.
5. Maintenance
To ensure optimal performance and longevity of your cMT Gateway, follow these maintenance guidelines:
- Environmental Conditions: Operate the device within the specified temperature and humidity ranges (refer to specifications table). Avoid direct sunlight, excessive dust, and corrosive environments.
- Cleaning: Use a soft, dry cloth to clean the exterior of the device. Do not use liquid cleaners or solvents.
- Firmware Updates: Periodically check the Weintek website for firmware updates to ensure your gateway has the latest features and security patches.
- Connection Checks: Regularly inspect power and communication cables for damage or loose connections.
6. Troubleshooting
If you encounter issues with your cMT Gateway, consider the following common troubleshooting steps:
- No Power: Verify the 24VDC power supply is connected correctly and providing the correct voltage. Check power cable integrity.
- No Network Connection: Ensure Ethernet cables are securely connected. Check network settings in EasyBuilder Pro. For Wi-Fi models, confirm antenna connection and Wi-Fi configuration.
- Communication Errors with Devices: Verify serial port settings (baud rate, parity, data bits, stop bits) match the connected device. Check wiring for RS-232/RS-485. Ensure the correct communication protocol is selected in EasyBuilder Pro.
- Gateway Unresponsive: Try power cycling the device. If the issue persists, connect via Ethernet and attempt to re-upload the project or restore factory settings via EasyBuilder Pro.
7. Specifications
The following table details the specifications for the Weintek cMT Gateway series:

| Feature | cMT-G01X | cMT-G02X | cMT-G03 | cMT-G04 |
|---|---|---|---|---|
| Memory (Flash) | 256 MB | 256 MB | 256 MB | 256 MB |
| Memory (RAM) | 256 MB | 256 MB | 256 MB | 256 MB |
| Processor | Quad-core RISC | Quad-core RISC | Single-core RISC | Single-core RISC |
| Ethernet | 10/100 Base-T x 2 | 10/100 Base-T x 1 | 10/100 Base-T x 1 | LAN:10/100 Base-T x1, SW1, SW2:10/100 Base-T x1 (2 port Ethernet switch) |
| Wi-Fi | N/A | IEEE 802.11 b/g/n, 802.11b: max 19.52 dBm, 802.11g: max 13.35 dBm, 802.11n: max 11.28 dBm | N/A | N/A |
| COM Port | COM1: RS-232 2W, COM2: RS-485 2W/4W, COM3: RS-485 2W | COM1: RS-232 2W, COM2: RS-485 2W/4W, COM3: RS-485 2W | COM1: RS-232 2W, RS-485 2W/4W, COM2: RS-232 2W, RS-485 2W/4W | N/A |
| RTC | Built-in | Built-in | Built-in | Built-in |
| Input Power | 24±20%VDC | 24±20%VDC | 10.5-28VDC | 10.5-28VDC |
| Power Isolation | Built-in | Built-in | Built-in | Built-in |
| Power Consumption | 230mA@24VDC | 450mA@24VDC | 300mA@12VDC, 150mA@24VDC | 270mA@12VDC, 150mA@24VDC |
| Voltage Resistance | 500VAC (1 min.) | 500VAC (1 min.) | 500VAC (1 min.) | 500VAC (1 min.) |
| Isolation Resistance | Exceed 50MΩ at 500VDC | Exceed 50MΩ at 500VDC | Exceed 50MΩ at 500VDC | Exceed 50MΩ at 500VDC |
| PCB Coating | Yes | Yes | Yes | Yes |
| Enclosure | Plastic | Plastic | Plastic | Plastic |
| Dimensions WxHxD | 27 x 130 x 115 mm | 27 x 130 x 115 mm | 27 x 109 x 81 mm | 27 x 109 x 81 mm |
| Weight | Approx. 0.18 kg | Approx. 0.18 kg | Approx. 0.14 kg | Approx. 0.14 kg |
| Mount | 35 mm DIN rail mounting | 35 mm DIN rail mounting | 35 mm DIN rail mounting | 35 mm DIN rail mounting |
| Protection Structure | IP20 | IP20 | IP20 | IP20 |
| Storage Temperature | -20° ~ 70°C (-4° ~ 158°F) | -20° ~ 70°C (-4° ~ 158°F) | -20° ~ 60°C (-4° ~ 140°F) | -20° ~ 60°C (-4° ~ 140°F) |
| Operating Temperature | -20° ~ 55°C (-4° ~ 131°F) | -20° ~ 55°C (-4° ~ 131°F) | 0° ~ 50°C (32° ~ 122°F) | 0° ~ 50°C (32° ~ 122°F) |
| Relative Humidity | 10% ~ 90% (non-condensing) | 10% ~ 90% (non-condensing) | 10% ~ 90% (non-condensing) | 10% ~ 90% (non-condensing) |
| Altitude (Air Humidity) | 3,000 m | 3,000 m | Below 3,000 meters (70.1kPa) | Below 3,000 meters (70.1kPa) |
| Vibration Endurance | 10 to 25Hz (X, Y, Z direction 2G 30 minutes) | 10 to 25Hz (X, Y, Z direction 2G 30 minutes) | 10 to 25Hz (X, Y, Z direction 2G 30 minutes) | 10 to 25Hz (X, Y, Z direction 2G 30 minutes) |
| Certificate | CE marked | CE marked | CE marked | CE marked |
| UL | cULus Listed | cULus Listed | cULus Listed | cULus Listed |
| Software | EasyBuilder Pro, EasyAccess 2.0 (Optional) | EasyBuilder Pro, EasyAccess 2.0 (Optional) | EasyBuilder Pro, EasyAccess 2.0 (Optional) | EasyBuilder Pro, EasyAccess 2.0 (Optional) |
Note: The image
shows a specific module (M02) with S/N: 2507254237, Input Power: 5VDC, Power Consumption: 900mA @ 5VDC, Operating Temperature: 0 - 55°C, Operation Humidity: 10-90%RH (non-condensing). This may be an accessory or a specific variant not fully detailed in the main gateway specifications.
8. User Tips
- Software Compatibility: Always use the latest version of EasyBuilder Pro for optimal compatibility and access to new features.
- Backup Projects: Regularly back up your gateway configuration projects to prevent data loss.
- Secure Connections: For remote access, ensure that EasyAccess 2.0 or other remote connection methods are configured with strong passwords and appropriate security measures.
- Environmental Monitoring: Pay close attention to the operating environment, especially temperature and humidity, to prevent premature device failure.
9. Warranty and Support
Weintek products typically come with a standard manufacturer's warranty. For specific warranty terms, technical support, or service inquiries, please refer to the official Weintek documentation or contact your authorized distributor. Ensure you have your product model and serial number available when seeking support.