Weintek cMT-G01X, cMT-G02X, cMT-G03, cMT-G04

Contents

Weintek cMT Gateway Series User Manual

Models: cMT-G01X, cMT-G02X, cMT-G03, cMT-G04

This manual provides essential information for the installation, operation, and maintenance of your Weintek cMT Gateway. Please read thoroughly before use.

1. Introduction

The Weintek cMT Gateway series offers robust and versatile solutions for industrial communication and data exchange. These gateways are designed to connect various industrial devices, facilitating data acquisition, remote monitoring, and control within an industrial automation environment. With different models offering varying connectivity options like Ethernet, Wi-Fi, and multiple COM ports, the cMT Gateway series provides flexibility for diverse application needs.

Weintek cMT Gateway series showing different models with Ethernet, WiFi, and COM ports
Figure 1: Weintek cMT Gateway Series (cMT-G01, cMT-G02, cMT-G03, cMT-G04)

2. Model Overview

The cMT Gateway series includes several models, each tailored for specific connectivity and performance requirements:

  • cMT-G01X: Features Ethernet connectivity and a Quad-core RISC processor.
  • cMT-G02X: Includes Ethernet and Wi-Fi (IEEE 802.11 b/g/n) connectivity, powered by a Quad-core RISC processor.
  • cMT-G03: Offers Ethernet and multiple COM ports (RS-232 2W, RS-485 2W/4W) with a Single-core RISC processor.
  • cMT-G04: Provides LAN/10/100 Base-T x1, SW1, SW2:10/100 Base-T x1 (2 port Ethernet switch) and a Single-core RISC processor.
Front view of a Weintek Gateway showing SW1, SW2, LAN ports and 24VDC power input
Figure 2: Front view of a cMT Gateway with Ethernet and Power Ports

3. Setup and Installation

3.1 Mounting

The cMT Gateway units are designed for 35 mm DIN rail mounting. Ensure the mounting location is stable, free from excessive vibration, and within the specified environmental operating conditions.

3.2 Power Connection

Connect the gateway to a 24VDC power source. Observe the polarity indicated on the device (+ and - terminals). Ensure the power supply is stable and meets the gateway's power consumption requirements.

3.3 Network and Communication Connections

  • Ethernet (LAN/SW1/SW2): Connect standard Ethernet cables to the appropriate ports for network communication.
  • Wi-Fi (cMT-G02X only): Ensure the Wi-Fi antenna is securely attached for wireless communication.
  • COM Ports (cMT-G03 only): Connect serial devices using RS-232 or RS-485 cables to the designated COM ports.

4. Operating Instructions

The Weintek cMT Gateway operates as a data exchange and communication hub. Configuration and management are typically performed using the EasyBuilder Pro software.

4.1 Initial Configuration with EasyBuilder Pro

  1. Install EasyBuilder Pro software on your PC.
  2. Connect your PC to the cMT Gateway via Ethernet.
  3. Launch EasyBuilder Pro and establish communication with the gateway.
  4. Configure network settings, communication protocols for connected devices (e.g., PLC, sensors), and data logging parameters as required by your application.
  5. Upload the project to the cMT Gateway.

4.2 Data Exchange and Monitoring

Once configured, the gateway will automatically collect data from connected devices, perform protocol conversions, and make data available for monitoring, logging, or transmission to other systems (e.g., SCADA, cloud platforms) as defined in your EasyBuilder Pro project.

5. Maintenance

To ensure optimal performance and longevity of your cMT Gateway, follow these maintenance guidelines:

  • Environmental Conditions: Operate the device within the specified temperature and humidity ranges (refer to specifications table). Avoid direct sunlight, excessive dust, and corrosive environments.
  • Cleaning: Use a soft, dry cloth to clean the exterior of the device. Do not use liquid cleaners or solvents.
  • Firmware Updates: Periodically check the Weintek website for firmware updates to ensure your gateway has the latest features and security patches.
  • Connection Checks: Regularly inspect power and communication cables for damage or loose connections.

6. Troubleshooting

If you encounter issues with your cMT Gateway, consider the following common troubleshooting steps:

  • No Power: Verify the 24VDC power supply is connected correctly and providing the correct voltage. Check power cable integrity.
  • No Network Connection: Ensure Ethernet cables are securely connected. Check network settings in EasyBuilder Pro. For Wi-Fi models, confirm antenna connection and Wi-Fi configuration.
  • Communication Errors with Devices: Verify serial port settings (baud rate, parity, data bits, stop bits) match the connected device. Check wiring for RS-232/RS-485. Ensure the correct communication protocol is selected in EasyBuilder Pro.
  • Gateway Unresponsive: Try power cycling the device. If the issue persists, connect via Ethernet and attempt to re-upload the project or restore factory settings via EasyBuilder Pro.

7. Specifications

The following table details the specifications for the Weintek cMT Gateway series:

Table of specifications for cMT-G01X, cMT-G02X, cMT-G03, cMT-G04 including memory, processor, I/O, power, dimensions, environment, and software
Figure 3: Weintek cMT Gateway Series Specifications
Weintek cMT Gateway Series Technical Specifications
FeaturecMT-G01XcMT-G02XcMT-G03cMT-G04
Memory (Flash)256 MB256 MB256 MB256 MB
Memory (RAM)256 MB256 MB256 MB256 MB
ProcessorQuad-core RISCQuad-core RISCSingle-core RISCSingle-core RISC
Ethernet10/100 Base-T x 210/100 Base-T x 110/100 Base-T x 1LAN:10/100 Base-T x1, SW1, SW2:10/100 Base-T x1 (2 port Ethernet switch)
Wi-FiN/AIEEE 802.11 b/g/n, 802.11b: max 19.52 dBm, 802.11g: max 13.35 dBm, 802.11n: max 11.28 dBmN/AN/A
COM PortCOM1: RS-232 2W, COM2: RS-485 2W/4W, COM3: RS-485 2WCOM1: RS-232 2W, COM2: RS-485 2W/4W, COM3: RS-485 2WCOM1: RS-232 2W, RS-485 2W/4W, COM2: RS-232 2W, RS-485 2W/4WN/A
RTCBuilt-inBuilt-inBuilt-inBuilt-in
Input Power24±20%VDC24±20%VDC10.5-28VDC10.5-28VDC
Power IsolationBuilt-inBuilt-inBuilt-inBuilt-in
Power Consumption230mA@24VDC450mA@24VDC300mA@12VDC, 150mA@24VDC270mA@12VDC, 150mA@24VDC
Voltage Resistance500VAC (1 min.)500VAC (1 min.)500VAC (1 min.)500VAC (1 min.)
Isolation ResistanceExceed 50MΩ at 500VDCExceed 50MΩ at 500VDCExceed 50MΩ at 500VDCExceed 50MΩ at 500VDC
PCB CoatingYesYesYesYes
EnclosurePlasticPlasticPlasticPlastic
Dimensions WxHxD27 x 130 x 115 mm27 x 130 x 115 mm27 x 109 x 81 mm27 x 109 x 81 mm
WeightApprox. 0.18 kgApprox. 0.18 kgApprox. 0.14 kgApprox. 0.14 kg
Mount35 mm DIN rail mounting35 mm DIN rail mounting35 mm DIN rail mounting35 mm DIN rail mounting
Protection StructureIP20IP20IP20IP20
Storage Temperature-20° ~ 70°C (-4° ~ 158°F)-20° ~ 70°C (-4° ~ 158°F)-20° ~ 60°C (-4° ~ 140°F)-20° ~ 60°C (-4° ~ 140°F)
Operating Temperature-20° ~ 55°C (-4° ~ 131°F)-20° ~ 55°C (-4° ~ 131°F)0° ~ 50°C (32° ~ 122°F)0° ~ 50°C (32° ~ 122°F)
Relative Humidity10% ~ 90% (non-condensing)10% ~ 90% (non-condensing)10% ~ 90% (non-condensing)10% ~ 90% (non-condensing)
Altitude (Air Humidity)3,000 m3,000 mBelow 3,000 meters (70.1kPa)Below 3,000 meters (70.1kPa)
Vibration Endurance10 to 25Hz (X, Y, Z direction 2G 30 minutes)10 to 25Hz (X, Y, Z direction 2G 30 minutes)10 to 25Hz (X, Y, Z direction 2G 30 minutes)10 to 25Hz (X, Y, Z direction 2G 30 minutes)
CertificateCE markedCE markedCE markedCE marked
ULcULus ListedcULus ListedcULus ListedcULus Listed
SoftwareEasyBuilder Pro, EasyAccess 2.0 (Optional)EasyBuilder Pro, EasyAccess 2.0 (Optional)EasyBuilder Pro, EasyAccess 2.0 (Optional)EasyBuilder Pro, EasyAccess 2.0 (Optional)

Note: The image Close-up of a module labeled M02 with serial number and power information shows a specific module (M02) with S/N: 2507254237, Input Power: 5VDC, Power Consumption: 900mA @ 5VDC, Operating Temperature: 0 - 55°C, Operation Humidity: 10-90%RH (non-condensing). This may be an accessory or a specific variant not fully detailed in the main gateway specifications.

8. User Tips

  • Software Compatibility: Always use the latest version of EasyBuilder Pro for optimal compatibility and access to new features.
  • Backup Projects: Regularly back up your gateway configuration projects to prevent data loss.
  • Secure Connections: For remote access, ensure that EasyAccess 2.0 or other remote connection methods are configured with strong passwords and appropriate security measures.
  • Environmental Monitoring: Pay close attention to the operating environment, especially temperature and humidity, to prevent premature device failure.

9. Warranty and Support

Weintek products typically come with a standard manufacturer's warranty. For specific warranty terms, technical support, or service inquiries, please refer to the official Weintek documentation or contact your authorized distributor. Ensure you have your product model and serial number available when seeking support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.