INKBIRDPLUS HD08

Contents

INKBIRDPLUS HD08 Plug-in Carbon Monoxide Detector

3-in-1 Air Quality Monitor with Audible Alarm, Temperature, and Humidity Detection

Model: HD08 | Brand: INKBIRDPLUS

1. Introduction

The INKBIRDPLUS HD08 is a plug-in carbon monoxide detector designed to provide real-time monitoring of indoor carbon monoxide (CO) concentration, temperature, and humidity. This device alerts you with an audible and visual alarm when CO levels reach a dangerous threshold, helping to ensure a healthier and safer environment. Its lightweight and portable design makes it suitable for various locations including kitchens, living rooms, bedrooms, hotels, garages, restaurants, and recreational vehicles.

Note: If there is no carbon monoxide gas in the environment, it is normal for the screen to display "0000 PPM".

2. Key Features

  • Plug and Play: Easy to use with a simple plug-in design.
  • 3-in-1 Detection: Simultaneously detects indoor carbon monoxide, temperature, and humidity.
  • High-Definition Display: IPS full-view screen provides clear readings from any angle.
  • Audible and Visual Alarm: Features an audible alarm and a 3-color indication icon for high CO levels.
  • Adjustable Brightness: Offers 3 brightness modes (day/night/sleep) for various situations.
  • Switchable Temperature Units: Easily switch between Celsius (°C) and Fahrenheit (°F).
  • Wide Application: Ideal for homes, hotels, garages, restaurants, RVs, and more.

3. Package Contents

Please check the package for the following items:

  • 1x INKBIRDPLUS HD08 Plug-in Carbon Monoxide Detector
  • 1x USB-C Charging Cable
  • 1x User Manual

4. Setup Instructions

  1. Unpack the Device: Carefully remove the HD08 detector and all accessories from the packaging.
  2. Choose a Location: Select a suitable location for the detector. It should be plugged into a standard AC 110-220V/50-60Hz wall outlet. For optimal CO detection, place it at a height where CO is most likely to be present, typically at chest level, and away from direct drafts, windows, or vents that could interfere with readings. Avoid placing it directly above heat sources or in extremely humid areas.
  3. Plug In: Insert the detector directly into a wall outlet. The device will power on automatically.
  4. Initial Self-Check: Upon powering on, the device will perform a self-check. The screen will illuminate, and the intelligent power indicator light will show its status.
INKBIRDPLUS HD08 Carbon Monoxide Detector overview
Figure 1: Overview of the INKBIRDPLUS HD08 Carbon Monoxide Detector, highlighting real-time CO monitoring, high precision sensors, HD colorful screen, audible/visual alarm, fault self-check, and plug-and-play functionality.
HD08 detector in a room setting
Figure 2: The HD08 detector displaying CO concentration (008 PPM), temperature (25°C), and humidity (60%) in a home environment, emphasizing highly sensitive gas detection and audible/visual alarm.

5. Operating Instructions

5.1 Display Information

The 2.1-inch HD color screen displays the following information:

  • CO Concentration: Shown in PPM (Parts Per Million).
  • Temperature: Displayed in Celsius (°C) or Fahrenheit (°F).
  • Humidity: Displayed as a percentage (%).
  • Indicator Icons: Icons for speaker (sound), green leaf (air quality/normal operation), and sun (brightness mode).
2.1 inch HD color screen display details
Figure 3: Details of the 2.1-inch HD color screen display, featuring IPS ultra-broad perspective, 240*296 resolving power, and clear CO values.

5.2 Buttons and Functions

The device features three buttons (H, O, D) on the front panel:

  • 'O' Button (Self-Test): Short press this button to initiate a self-test of the device. This checks the sensor and alarm functionality.
  • 'H' Button (Humidity/Temperature Unit Switch): Press this button to switch the temperature display between Celsius (°C) and Fahrenheit (°F).
  • 'D' Button (Brightness Mode): Press this button to cycle through the 3 brightness modes: Day Mode, Night Mode, and Sleep Mode.
Intelligent Power Indicator Light and self-test button
Figure 4: Close-up of the HD08 detector showing the intelligent power indicator light (green for normal, red for alarm/fault) and the 'O' button for self-testing.

5.3 Intelligent Power Indicator Light

  • Green Light (Screen Off and Indicator Light On): Indicates normal operation and CO gas concentration monitoring.
  • Red Light (Alarm): Indicates a mute error, sensor malfunction, or detection of dangerous CO levels.

5.4 Alarm Function

When the carbon monoxide concentration reaches the alarm threshold (50-999 ppm), the device will trigger an audible alarm and the screen will display a visual warning (red light). This sound and light alarm is designed to alert you to potential danger.

Sound and light alarm illustration
Figure 5: Illustration of the HD08 detector emitting sound and light alarms when CO levels are detected, demonstrating its function to prevent danger.

6. Maintenance

  • Cleaning: Regularly wipe the exterior of the detector with a soft, dry cloth. Do not use abrasive cleaners, solvents, or detergents, as these can damage the device or interfere with sensor operation.
  • Sensor Life: The CO sensor has an approximate service life of 5 years. After this period, it is recommended to replace the device to ensure continued accuracy and safety.
  • Avoid Obstructions: Ensure the air ducts (porous areas) on the device are not blocked by dust or other objects, as this can affect detection accuracy.
3D porous air duct design
Figure 6: Diagram showing the 3D porous air duct design of the HD08 detector, indicating accurate detection of CO gas through air circulation.
High precision sensors internal view
Figure 7: Exploded view of the HD08 detector, revealing its high precision sensors and internal components, highlighting sensitive and stable detection performance.

7. Troubleshooting

ProblemPossible CauseSolution
Screen displays "0000 PPM"No carbon monoxide detected in the environment.This is normal operation. The device is functioning correctly.
Red light/Alarm without apparent CO sourceMute error, sensor malfunction, or presence of low-level CO.Perform a self-test using the 'O' button. If the alarm persists or indicates a fault, ensure proper ventilation and consider professional inspection of potential CO sources. If the issue continues, contact customer support.
No display/Device not powering onNo power supply or faulty outlet.Ensure the device is securely plugged into a working AC outlet. Try a different outlet to rule out an issue with the power source.
Inaccurate temperature/humidity readingsDevice placed near heat/cold sources or in direct sunlight/drafts.Relocate the device to a more central area, away from extreme temperature fluctuations or direct environmental influences.

8. User Tips

  • Optimal Placement: For best results, place the detector in a central location within the room, at a height that allows for effective air sampling, typically at eye level or slightly lower. Avoid corners or areas with limited air circulation.
  • Regular Self-Testing: Periodically use the self-test function to ensure the alarm and sensor are working correctly.
  • Understand Readings: Familiarize yourself with what different CO PPM readings mean and the alarm thresholds to react appropriately in an emergency.

9. Specifications

ParameterValue
Product ModelHD08 (IB-0905-XX)
Brand NameINKBIRD
Is Smart DeviceNo
With LCD ScreenYes
Gas TypeCO (Carbon Monoxide)
DIY SuppliesElectrical
OriginMainland China
CertificationCE, FCC
CO Measuring Range0-999 ppm (±5%)
CO Alarm Range50-999 ppm
Temperature Measuring Range-10℃ to 50℃ / 14°F to 122°F (±3%)
Air Humidity Measuring Range0% to 95% RH (±5%)
Data Refresh Frequency2 seconds
Input VoltageAC 110-220V / 50-60Hz
Working Current0.5A Max
Service Life (Sensor)Approximately 5 years
Working Environment Temperature-10℃ to 60℃ / 14°F to 140°F
Working Environment Humidity20% to 80% RH

10. Warranty and Support

For warranty information and technical support, please refer to the official INKBIRDPLUS website or contact your retailer. Keep your purchase receipt as proof of purchase for any warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.