1. Introduction
The INKBIRDPLUS HD08 is a plug-in carbon monoxide detector designed to provide real-time monitoring of indoor carbon monoxide (CO) concentration, temperature, and humidity. This device alerts you with an audible and visual alarm when CO levels reach a dangerous threshold, helping to ensure a healthier and safer environment. Its lightweight and portable design makes it suitable for various locations including kitchens, living rooms, bedrooms, hotels, garages, restaurants, and recreational vehicles.
Note: If there is no carbon monoxide gas in the environment, it is normal for the screen to display "0000 PPM".
2. Key Features
- Plug and Play: Easy to use with a simple plug-in design.
- 3-in-1 Detection: Simultaneously detects indoor carbon monoxide, temperature, and humidity.
- High-Definition Display: IPS full-view screen provides clear readings from any angle.
- Audible and Visual Alarm: Features an audible alarm and a 3-color indication icon for high CO levels.
- Adjustable Brightness: Offers 3 brightness modes (day/night/sleep) for various situations.
- Switchable Temperature Units: Easily switch between Celsius (°C) and Fahrenheit (°F).
- Wide Application: Ideal for homes, hotels, garages, restaurants, RVs, and more.
3. Package Contents
Please check the package for the following items:
- 1x INKBIRDPLUS HD08 Plug-in Carbon Monoxide Detector
- 1x USB-C Charging Cable
- 1x User Manual
4. Setup Instructions
- Unpack the Device: Carefully remove the HD08 detector and all accessories from the packaging.
- Choose a Location: Select a suitable location for the detector. It should be plugged into a standard AC 110-220V/50-60Hz wall outlet. For optimal CO detection, place it at a height where CO is most likely to be present, typically at chest level, and away from direct drafts, windows, or vents that could interfere with readings. Avoid placing it directly above heat sources or in extremely humid areas.
- Plug In: Insert the detector directly into a wall outlet. The device will power on automatically.
- Initial Self-Check: Upon powering on, the device will perform a self-check. The screen will illuminate, and the intelligent power indicator light will show its status.


5. Operating Instructions
5.1 Display Information
The 2.1-inch HD color screen displays the following information:
- CO Concentration: Shown in PPM (Parts Per Million).
- Temperature: Displayed in Celsius (°C) or Fahrenheit (°F).
- Humidity: Displayed as a percentage (%).
- Indicator Icons: Icons for speaker (sound), green leaf (air quality/normal operation), and sun (brightness mode).

5.2 Buttons and Functions
The device features three buttons (H, O, D) on the front panel:
- 'O' Button (Self-Test): Short press this button to initiate a self-test of the device. This checks the sensor and alarm functionality.
- 'H' Button (Humidity/Temperature Unit Switch): Press this button to switch the temperature display between Celsius (°C) and Fahrenheit (°F).
- 'D' Button (Brightness Mode): Press this button to cycle through the 3 brightness modes: Day Mode, Night Mode, and Sleep Mode.

5.3 Intelligent Power Indicator Light
- Green Light (Screen Off and Indicator Light On): Indicates normal operation and CO gas concentration monitoring.
- Red Light (Alarm): Indicates a mute error, sensor malfunction, or detection of dangerous CO levels.
5.4 Alarm Function
When the carbon monoxide concentration reaches the alarm threshold (50-999 ppm), the device will trigger an audible alarm and the screen will display a visual warning (red light). This sound and light alarm is designed to alert you to potential danger.

6. Maintenance
- Cleaning: Regularly wipe the exterior of the detector with a soft, dry cloth. Do not use abrasive cleaners, solvents, or detergents, as these can damage the device or interfere with sensor operation.
- Sensor Life: The CO sensor has an approximate service life of 5 years. After this period, it is recommended to replace the device to ensure continued accuracy and safety.
- Avoid Obstructions: Ensure the air ducts (porous areas) on the device are not blocked by dust or other objects, as this can affect detection accuracy.


7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Screen displays "0000 PPM" | No carbon monoxide detected in the environment. | This is normal operation. The device is functioning correctly. |
| Red light/Alarm without apparent CO source | Mute error, sensor malfunction, or presence of low-level CO. | Perform a self-test using the 'O' button. If the alarm persists or indicates a fault, ensure proper ventilation and consider professional inspection of potential CO sources. If the issue continues, contact customer support. |
| No display/Device not powering on | No power supply or faulty outlet. | Ensure the device is securely plugged into a working AC outlet. Try a different outlet to rule out an issue with the power source. |
| Inaccurate temperature/humidity readings | Device placed near heat/cold sources or in direct sunlight/drafts. | Relocate the device to a more central area, away from extreme temperature fluctuations or direct environmental influences. |
8. User Tips
- Optimal Placement: For best results, place the detector in a central location within the room, at a height that allows for effective air sampling, typically at eye level or slightly lower. Avoid corners or areas with limited air circulation.
- Regular Self-Testing: Periodically use the self-test function to ensure the alarm and sensor are working correctly.
- Understand Readings: Familiarize yourself with what different CO PPM readings mean and the alarm thresholds to react appropriately in an emergency.
9. Specifications
| Parameter | Value |
|---|---|
| Product Model | HD08 (IB-0905-XX) |
| Brand Name | INKBIRD |
| Is Smart Device | No |
| With LCD Screen | Yes |
| Gas Type | CO (Carbon Monoxide) |
| DIY Supplies | Electrical |
| Origin | Mainland China |
| Certification | CE, FCC |
| CO Measuring Range | 0-999 ppm (±5%) |
| CO Alarm Range | 50-999 ppm |
| Temperature Measuring Range | -10℃ to 50℃ / 14°F to 122°F (±3%) |
| Air Humidity Measuring Range | 0% to 95% RH (±5%) |
| Data Refresh Frequency | 2 seconds |
| Input Voltage | AC 110-220V / 50-60Hz |
| Working Current | 0.5A Max |
| Service Life (Sensor) | Approximately 5 years |
| Working Environment Temperature | -10℃ to 60℃ / 14°F to 140°F |
| Working Environment Humidity | 20% to 80% RH |
10. Warranty and Support