1. Introduction
The JIKONG Smart Active Balance Battery Management System (BMS) is an intelligent power management solution designed for various lithium battery types, including Li-ion, LiFePo4, and LTO. It supports battery configurations from 4S to 24S (series) and offers active balancing to optimize battery performance and lifespan. The system features a high-performance MCU, a full aluminum alloy shell for superior heat dissipation and protection, and supports multi-interface displays and app connectivity for comprehensive monitoring and control.

2. Safety Information
- Always disconnect the battery pack from any power source before installing or servicing the BMS.
- Ensure all wiring connections are correct and secure to prevent short circuits or damage.
- Wear appropriate personal protective equipment (PPE), including safety glasses and insulated gloves, when working with batteries.
- Do not attempt to open or modify the BMS unit, as this may void the warranty and pose safety risks.
- Keep the BMS away from water, moisture, and extreme temperatures. The aluminum alloy shell provides dustproof and waterproof protection, but proper installation is crucial.
- Refer to the specific wiring diagrams for your battery configuration to ensure correct installation.
3. Package Contents
Upon opening your JIKONG Smart Active Balance BMS package, you should find the following items:
- BMS Unit x 1
- Sampling Cable (Balance Wires) x 1 or 2 (typically 70cm long)
- NTC Temperature Sensor x 1 (typically 40cm long)
- Power Switch Button x 1 (typically 50cm long)
- Bolt Screws x 2-6 (depending on model)
- Exclusive Packaging Box x 1

4. Setup and Installation
4.1. Wiring Instructions
- Connect all cables: Carefully connect all necessary cables to the BMS unit.
- Insert the cable into the BMS: Ensure all connectors are fully seated into their respective ports on the BMS.
- Connect B-line and P-line to the battery: Connect the main negative (B-) and positive (P-) lines from the BMS to your battery pack.
Important: Always follow the specific wiring diagram for your battery series configuration (e.g., 4S, 8S, 16S, 24S) to ensure correct and safe operation.




4.2. App and Software Installation
The JIKONG BMS features Bluetooth connectivity, allowing you to monitor and adjust parameters via a mobile app or PC software.
- Mobile App: Search for "JK BMS" in the Apple App Store (for iOS devices) or Google Play Store (for Android devices). The app supports multiple languages and provides real-time data.
- PC Software: PC software is available for more detailed monitoring and configuration.
- QR Code: A QR code is printed on the BMS panel. Scan this code to directly download the app and access the instruction manual.

5. Operating Instructions
5.1. Active Balancing (Lossless Balancing)
The JIKONG BMS utilizes active balancing technology to transfer energy from cells with higher voltage to cells with lower voltage. This process minimizes energy loss and ensures all cells in the battery pack remain balanced, extending the overall battery lifespan and improving performance.
- Active balancing operates continuously, whether the battery is charging, discharging, or idle, until the voltage difference between cells is within the set range.
- The active balancing current typically ranges from 0.4A to 2A, allowing for efficient balancing even in larger capacity battery packs without generating excessive heat.

5.2. Monitoring and Configuration
The JIKONG BMS offers multiple ways to monitor battery status and configure settings:
- Mobile App: The "JIKONG SMART BMS" app provides real-time data on voltage, current, temperature, State of Charge (SOC), alarms, and cycle counts.
- PC Software: Connect the BMS to a computer to access advanced settings and detailed logging.
- External Displays: Optional 2.5-inch, 3.2-inch, or 4.3-inch touch displays can be connected to the BMS for direct monitoring of key parameters.

5.3. Adjusting Protection Values
Through the mobile app or PC software, you can freely adjust various protection values, including:
- Overcharge Protection
- Over-discharge Protection
- Overcurrent Protection
- Temperature Protection (high and low)
- Balance Voltage Settings
Always read the internal parameters of the protection board before making any changes to ensure proper configuration.
5.4. Inverter Communication Protocols
The JIKONG BMS supports various mainstream inverter communication protocols, allowing for seamless integration with your power system. Supported protocols can be set up through the mobile app.

6. Maintenance
- Regular Monitoring: Periodically check the battery status via the mobile app or external display to ensure optimal performance and identify any potential issues early.
- Connection Integrity: Ensure all wiring connections remain secure and free from corrosion. Loose connections can lead to poor performance or safety hazards.
- Physical Inspection: Inspect the BMS unit for any signs of physical damage. The full aluminum alloy shell provides robust protection against dust, water, vibration, and external impacts.
- Firmware Updates: Check the JIKONG official website or app for any available firmware updates to ensure your BMS has the latest features and bug fixes.

7. Troubleshooting
- BMS Not Responding: Check all power connections to the BMS and the battery. Ensure the power switch button is correctly connected and activated.
- App Connectivity Issues: Ensure Bluetooth is enabled on your mobile device and the BMS is within range. Restart both the app and the BMS if necessary.
- Battery Imbalance: If the app indicates significant cell voltage differences, ensure the active balancing feature is enabled and configured correctly. Allow time for the active balancing to work.
- Error Codes/Alarms: Refer to the mobile app or PC software for specific error codes and their descriptions. The manual (accessible via QR code) may also provide a list of common error codes.
- Lost BMS Access (e.g., after password change): If you lose access to the BMS after changing a password, contact JIKONG customer support for assistance. They may be able to guide you through a reset procedure.
- Hardware Version Identification: If you need to determine the hardware version for support or compatibility, check the product packaging, the BMS unit itself, or contact JIKONG customer support with your product details.
8. Specifications
| Feature | Specification |
|---|---|
| Brand | JIKONG |
| Type | LI-ION Battery BMS (Active Balanced BMS) |
| Battery Series Support | 4S-24S (varies by model) |
| Compatible Battery Types | Li-ion, LiFePo4, LTO Battery |
| Active Balancing Current | 0.4A - 2A |
| Continuous Charge Current | 40A - 300A (model dependent) |
| Continuous Discharge Current | 40A - 300A (model dependent) |
| Maximum Discharge Current (2min) | 100A - 600A (model dependent) |
| Interfaces | RS485, Bluetooth (BT), CAN, NTC, GPS (customized), Display/Switch, Heat (customized) |
| Protection Functions | Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection, Overheat Protection, Low Temperature Protection |
| Voltage Detection Accuracy | ±0.015V |
| Short Circuit Protection Response | 10-500μs |
| Shell Material | Full Aluminum Alloy |
| Certification | CE, FCC, RoHS |
| Support System | Android, iOS, HarmonyOS |


9. User Tips
- Model Selection: When choosing a JIKONG BMS, carefully match the 'S' (series) count to your battery pack configuration (e.g., 8S, 12S, 16S, 24S) and ensure the continuous charge/discharge current ratings meet your application's requirements.
- Battery Compatibility: The BMS is designed for Li-ion, LiFePo4, and LTO batteries. This includes common cell types like 18650 lithium batteries, provided the series count is correct.
- Included Cables: The package typically includes sampling cables (balance wires) of 70cm length, an NTC temperature sensor of 40cm, and a power switch button of 50cm. Verify these lengths are suitable for your installation.
- App Features: Utilize the mobile app for real-time monitoring of individual cell voltages, overall pack voltage, current, temperature, and State of Charge (SOC). This helps in proactive maintenance and troubleshooting.
- Customization: JIKONG offers personalized customization for structure, hardware (e.g., temperature control, power display board, soft switch), and software (e.g., APP, host computer). Contact JIKONG for specific customization needs.
10. Warranty and Support
For any technical assistance, warranty claims, or product inquiries, please contact JIKONG customer support through their official channels. Refer to the QR code on your BMS unit or the JIKONG website for contact information and additional resources.