PDDAXLQUE CP26

Contents

CP26 Serial Adapter Industrial Bluetooth Communication Module Instruction Manual

Model: CP26

Brand: PDDAXLQUE

1. Introduction

The PDDAXLQUE CP26 is an industrial-grade Bluetooth communication module designed to convert wired RS232/RJ45 interfaces to wireless Bluetooth. This allows for seamless communication between various devices such as PCs, smartphones, PLCs, sensors, and electronic scales, eliminating the need for traditional wired connections. It supports Bluetooth 5.1 and features a built-in rechargeable lithium battery for portable use.

CP26 Bluetooth to RS232/RJ45 Adapter
Figure 1: CP26 Bluetooth to RS232/RJ45 Adapter with RS232 cable and USB adapter.

2. Package Contents

Please verify that all items listed below are included in your package. The contents may vary slightly depending on the specific model (T1 for Mobile Phone, T2 for Computer, T3 for Device-to-Device).

CP26 Mobile Phone Model (T1)

  • DX-CP26 Adapter x1
  • Rod Rubber Antenna x1
  • USB Data Cable x1
  • Instruction Manual x1
  • RJ45 Adapter Cable x1
  • RS232 Adapter Cable (Male Connector) x1

CP26 Computer Model (T2)

  • DX-CP26 Adapter x1
  • Rod Rubber Antenna x1
  • USB Data Cable x1
  • Instruction Manual x1
  • RJ45 Adapter Cable x1
  • RS232 Adapter Cable (Male Connector) x1
  • CP11 Adapter x1

CP26 Device Model (T3)

  • DX-CP26 Adapter x2
  • Rod Rubber Antenna x2
  • USB Data Cable x2
  • Instruction Manual x1
  • RJ45 Adapter Cable x2
  • RS232 Adapter Cable (Male Connector) x2
Video 1: Unboxing and overview of the CP26 adapter and its accessories.

3. Product Specifications

FeatureSpecification
Model NumberCP26 for PC
Bluetooth NameRS232/RJ45
Bluetooth TypeBluetooth 5.1
ChipsetRenesas DA14531 chip + PA Amplifiers
Serial Port TypeRS232
Serial Port Default Parameters9600bps/8/n/1 (Baud rate/Data bits/No parity/Stop bits)
Supported Baud Rates2400, 4800, 9600, 19200, 38400, 57600, 115200
Power Supply MethodDC5-36V
Interface TypeRJ45/RS232 Interface
CP26 Dimensions60 x 27.8 x 16.4 mm
CP11 Dimensions67 x 25 x 10 mm
Antenna Length108 mm
Visible Distance (Mobile Phone)90m
Visible Distance (PC)70m
Visible Distance (Device-to-Device)400m
Working Temperature-40 to +85°C
CertificationCE ROHS
Battery Life24 hours (continuous, when not connected to power source)
CP26 Key Features and Dimensions
Figure 2: Key features and dimensions of the CP26 adapter.
CP26 RS232/RJ45 to Wireless Bluetooth Interface Features and Size
Figure 3: Overview of RS232/RJ45 to Wireless Bluetooth Interface features and size.

4. Device Overview

4.1 CP26 Product Diagram and Indicators

The CP26 adapter features several indicators and a multi-function KEY button:

  • TX (Red): Data transmission indicator. Blinks when Bluetooth sends data.
  • RX (Green): Data reception indicator. Blinks when Bluetooth receives data.
  • WORK (Blue): Operational status indicator.
    • Bluetooth not connected: Blue light flashes, indicating the baud rate code (number of flashes corresponds to baud rate).
    • Bluetooth connected: Blue light is steady on.
  • POWER (Red): Charging indicator.
    • Connected: Blue light is on for a long time.
    • Not connected: Blue light blinking times represent baud rate number.
    • Charging: Red light is on.
    • Fully Charged: Red light is off.
  • KEY Button: Multi-function button (on the side).
  • USB Port: USB power supply and charging port (Type-C).
  • ANT: External antenna connector.
  • RJ45 & RS232 Ports: For communication with devices.
CP26 Hardware Construction Description with Indicators and Key Button
Figure 4: CP26 Hardware Construction Description, showing indicators and KEY button.
Detailed description of CP26 labeled ports and indicators
Figure 5: Detailed view of CP26 labeled ports and indicators.

4.2 CP11 Adapter Overview (for Computer Model T2)

The CP11 adapter is a USB interface used to connect the CP26 to a computer. It also has indicators and a KEY button.

  • USB Port: Connects to the computer.
  • KEY Button: Disconnect/Switch baud rate.
  • WORK (Red): Work status light. Blinks for baud rate number when not connected. Steady on when connected.
  • TX (Green): Send data indicator.
  • RX (Blue): Receive data indicator.
CP11 Adapter Overview with Indicators and Key Button
Figure 6: CP11 Adapter overview, showing indicators and KEY button.

5. Setup Instructions

5.1 Install External Antenna

Screw the provided rod rubber antenna onto the ANT connector of the CP26 adapter. Ensure it is securely fastened for optimal signal strength.

5.2 Connect RS232/RJ45 Adapter Cable

Depending on your device, connect either the RS232 or RJ45 adapter cable to the corresponding port on the CP26. Then, connect the other end of the adapter cable to your target device.

RS232 and RJ45 Interface Pin Definitions
Figure 7: RS232 (DB9 Male) and RJ45 interface pin definitions.

5.3 Software Installation

Proper software installation is crucial for communication.

For Mobile Devices (Smartphones/Tablets):

  1. iOS users: Visit the App Store, search for "DX-SMART," and download/install the app.
  2. Android users: Visit Google Play or your phone's default app store, search for "DX-SMART," and download/install the app.
Android App Interface for CP26
Figure 8: Android App Interface for CP26, showing function selection and device list.

For Desktop/Bridge Version (PC):

When using the CP11 adapter, the computer must download and install the CH341SER driver software. It is recommended to use UartAssist serial communication software.

Download the hardware package (serial port software + driver software) from the official website or Google Drive. The product information pack typically contains "Read Me", "CH341SER drive", and "UartAssist".

Official Website: en.szdx-smart.com

Google Drive Link: drive.google.com/drive/folders/1aepOsN25qKyyDyuhDv8-njDIyJF608SP

GitHub Link: github.com/DX-SMART/WIRELESS-ADAPTER/blob/main/DX-CP26%20Development%20%26%20User%20Information.rar

If you are unable to download, please contact our after-sales team: Manager@szdx-smart.com.

6. Operating Instructions

6.1 Power On/Off

  • Power On: Long press the KEY button for one second.
  • Power Off: Long press the KEY button for three seconds.

6.2 Baud Rate Adjustment

The CP26 and CP11 adapters support various baud rates. The factory default baud rate is 9600bps.

  • To switch baud rate: When Bluetooth is disconnected, short press the KEY button twice consecutively.
  • The number of flashes of the blue (CP26 WORK indicator) or red (CP11 WORK indicator) LED indicates the current baud rate code.
Flash CountBaud Rate
1 time2400
2 times4800
3 times9600 (Factory Default)
4 times19200
5 times38400
6 times57600
7 times115200

6.3 Connection Methods and Modes of Transmission

The CP26 supports three main modes of transmission:

Mode 1: Mobile Phone & CP26 Slave (Transparent Transmission)

Connect the CP26 to your RS232/RJ45 device. On your mobile phone, open the "DX-SMART" app, search for Bluetooth devices, and connect to the CP26. This allows your phone to control the connected device wirelessly.

Device and Mobile Phone Connection Method
Figure 9: Device and mobile phone connection method, showing the app interface and connection steps.

Mode 2: CP11 and CP26 Slave (Computer Model)

Connect the CP26 to your RS232/RJ45 device. Insert the CP11 adapter into your computer's USB port. Press and hold the KEY button of CP26 for one second to switch it on. Open the serial port software (e.g., UartAssist) on your computer, select the COM port of the CP11, and configure the default parameter configuration (9600bps/8/n/1). Wait for the CP11 adapter to actively search for the CP26 converter and connect. The blue light on the CP26 will be steady on upon successful connection, allowing for data interaction.

Wireless Communication between Computer and Devices
Figure 10: Wireless communication setup between a computer (via CP11) and a device (via CP26).

Mode 3: CP26 Master & CP26 Slave (Device Model)

This mode enables wireless data communication between two devices using two CP26 converters.

  1. Connect one CP26 (Master) to Device 1 via RS232/RJ45 interface.
  2. Connect the second CP26 (Slave) to Device 2 via RS232/RJ45 interface.
  3. The CP26 Master Bluetooth will connect to the CP26 Slave Bluetooth.
  4. After successful connection, data interaction can occur.
CP26 Connection Profile showing Master-Slave setup
Figure 11: CP26 Connection Profile, illustrating Master-Slave setup for device-to-device communication.

6.4 Application Scenarios

The CP26 adapter can be used in a wide range of applications:

  • Total Station & Mobile App: View total station data by mobile phone.
  • Switchboard & Mobile App: View data of the switch by phones.
  • PLC & PC: Update PLC programs via PC.
  • Sensor & Computer: Set inverter parameters on computer.
  • Lift Controller & PC: Set elevator parameters via PC.
  • Electronic Scales & Thermal Printer: Wireless communication between electronic scales and printers.
  • Other applications include cash registers, handwriting boards, touch screens, industrial control machines, temperature control equipment, tax control machines, scanners, CNC machine tools, PLAM, LED displays, and access control systems.
Bluetooth to RS232/RJ45 in different fields of application
Figure 12: Various application scenarios for the CP26 Bluetooth adapter.

7. Maintenance

  • Keep the device in a dry environment and avoid exposure to extreme temperatures.
  • Clean the device with a soft, dry cloth. Do not use harsh chemicals or solvents.
  • The built-in rechargeable lithium battery provides approximately 24 hours of continuous operation when not connected to a power source. Recharge using the provided USB Type-C cable.
  • Ensure the antenna is securely attached for optimal performance.

8. Troubleshooting

Q: The device is blinking but there is no communication.
A: This often indicates a mismatch in baud rates or an issue with the software connection.
  • Check Baud Rate: Ensure the baud rate of the CP26 (indicated by blue/red LED flashes) matches the baud rate configured in your serial communication software or the connected device. Adjust the baud rate by double-pressing the KEY button when Bluetooth is disconnected.
  • Driver Installation: For PC connections, ensure the CH341SER driver is correctly installed for the CP11 adapter.
  • Software Configuration: Verify that your serial port software (e.g., UartAssist) is correctly configured with the right COM port and serial parameters (data bits, parity, stop bits).
  • Bluetooth Connection: Confirm that the Bluetooth connection is established (steady blue WORK light on CP26). If not, try disconnecting and reconnecting.
  • Cable Connection: Ensure all cables (RS232/RJ45, USB) are securely connected and compatible.
Q: How to perform a factory reset?
A: The manual does not explicitly describe a factory reset function. However, the default baud rate is 9600bps. If you encounter persistent issues, try re-configuring the baud rate to 9600bps and re-establishing the connection. For further assistance, please contact technical support.
Q: The device does not power on.
A: Ensure the device is charged. Connect the USB charging cable to a power source. If using the internal battery, ensure it has sufficient charge. Long press the KEY button for one second to power on.

9. User Tips

  • Always ensure the baud rate of the CP26 matches that of the connected device or software to avoid communication errors.
  • For PC connections, installing the CH341SER driver and using UartAssist software is highly recommended for stable operation.
  • When connecting cables, double-check the compatibility and secure fit to prevent connection issues.
  • If experiencing connection difficulties, try cycling the power of both the CP26 and the connected device.

10. Warranty and Support

For technical support, inquiries, or if you are unable to download necessary resources, please contact our after-sales team:

A detailed user manual in PDF format is also available for download from the official website or provided Google Drive/GitHub links.

Please refer to the accompanying installation guide to ensure correct operation and prevent any impact on normal usage. Always use the dedicated connection cables supplied with the equipment and ensure they are correctly inserted into the corresponding ports. When connecting cables, please verify the compatibility between ports and cables. Incorrect connections may result in the equipment failing to function properly.

Technical Support and Certifications
Figure 13: Technical support information and product certifications (CE, RoHS, ISO).
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.