EARU THC30A

Contents

EARU Electric Digital Programmable Timer Switch Relay

Model: THC30A

User Manual

1. Introduction

Thank you for choosing the EARU Electric Digital Programmable Timer Switch Relay. This device is designed for general purpose time control, offering advanced daily and weekly programming capabilities. It is suitable for various applications requiring automated ON/OFF switching of electrical circuits. Please read this manual thoroughly before installation and operation to ensure safe and correct usage.

Front view of the EARU Electric Digital Programmable Timer Switch Relay
Figure 1: Front view of the Digital Programmable Timer Switch Relay.

2. Safety Information

  • Always disconnect power before installing or servicing the device to prevent electric shock.
  • Installation should be performed by a qualified electrician or knowledgeable personnel.
  • Ensure the voltage and current ratings of the device match your application requirements.
  • Do not operate the device in environments exceeding the specified ambient temperature and humidity ranges.
  • Keep the device away from water and excessive moisture.
  • Do not attempt to disassemble or modify the device.

3. Product Features

  • DIN Rail Installation for easy mounting.
  • Advanced pre-setting for daily and weekly programs.
  • Digital electronics general purpose time switch.
  • Up to 18 ON/OFF settings for flexible scheduling.
  • Manual ON/OFF control capability.
  • Lithium battery power reserve ensures settings are retained during power outages (up to 3 years).
  • Automatic time error correction (±30 seconds weekly).
  • Convex buttons designed to prevent accidental operation.
  • Intuitive LCD display for clear data visualization.
  • Constructed with high-quality materials for reliability.
Diagram showing intelligent cycle system features: 18 Groups, 30A, 3 Years Power Reserve
Figure 2: Key features of the intelligent cycle system.
Images highlighting convex buttons, high-quality materials, LCD display, and DIN-Rail mounting
Figure 3: Design and installation features.

4. Specifications

ParameterValue
Model NumberTHC30A / AHC30
Brand NameEARU
Voltage RatingAC/DC 12V/220V
Rated Current30A
Power SourceAC / DC
TheoryTime Relay
Contact LoadHigh Power
Contact Type1NO1NC or 1NO
Protect FeatureSealed
CertificationCE
Hysteresis≤2 sec/day (25℃)
ON/OFF Operation18 ON & 18 OFF
Power Consumption7.5VA (max)
Service Life (Mechanical)107
Service Life (Electrical)105
Minimum Interval1 minute
WeightApprox. 150g
Count Down1 sec - 99 min 59 sec
Pulse1 sec - 59 min 59 sec
Load Capacity (Resistive)30A 250VAC
Load Capacity (Lagging)25A/250V
Load Capacity (Lamp)4.5KW
Switching Contact1 changeover switch
Power Reserve3 years (lithium battery)
Ambient Temperature-10°C to +40°C
Ambient Humidity35% ~ 85% RH
Diagram showing product dimensions and a table of technical parameters
Figure 4: Product dimensions and technical parameters.

5. Package Contents

The package typically includes:

  • 1 x EARU Electric Digital Programmable Timer Switch Relay (Model THC30A)
  • 1 x User Manual

6. Setup and Installation

The timer switch is designed for DIN rail mounting. Ensure power is disconnected before proceeding with installation.

6.1 Component Identification

Diagram identifying components: Power input (N, L), Working Indicator, LCD Screen, Hour, Min, Day, Timer, Clock, Reset, Manual buttons, and output terminals (NC, NO)
Figure 5: Labeled components of the timer switch.
  • Power Input (N, L): Terminals for connecting the main power supply (AC220-240V or DC/AC 12V depending on model).
  • Working Indicator: LED light indicating device operation.
  • LCD Screen: Displays time, day, and programming information.
  • Hour (H+), Minute (M+), Day (D+) Buttons: Used for setting time and programming.
  • Timer Button: Enters programming mode.
  • Clock Button: Used for setting current time.
  • Reset Button: Resets the device.
  • Manual Button (ON/AUTO/OFF): For manual control of the output.
  • Output Terminals (NC, NO): Normally Closed and Normally Open contacts for controlling the load.

6.2 Wiring Instructions

Connect the timer switch according to the appropriate wiring diagram for your model (1NO or 1NO1NC). Ensure all connections are secure.

Wiring diagram for 1NO 30A model, showing input N and L, and output N and L connections
Figure 6: Wiring diagram for 1NO 30A model.

For the 1NO 30A model (as shown in Figure 6):

  1. Connect the Neutral (N) and Live (L) wires of your power supply to the "INPUT: AC220-240V" terminals labeled 'N' and 'L' respectively.
  2. Connect the Neutral (N) and Live (L) wires of your load to the "OUTPUT" terminals labeled 'N' and 'L' respectively.

For 1NO1NC 30A models, refer to the specific terminal markings on your device for Normally Open (NO) and Normally Closed (NC) contacts to connect your load as required.

6.3 DIN Rail Mounting

The timer switch is designed for easy installation on a standard DIN rail. Simply align the device with the DIN rail and press firmly until it clicks into place. To remove, pull the orange clip at the bottom and lift the device off the rail.

Side view of the timer switch showing the orange DIN rail clip
Figure 7: Side view showing the DIN rail clip.

Video 1: Product overview and demonstration of DIN rail mounting and basic button functions.

7. Operation and Programming

The timer switch allows for precise control over your electrical devices. Follow these steps to set the time and program ON/OFF cycles.

7.1 Initial Setup and Reset

Before first use or after a prolonged power outage, it is recommended to reset the device. Use a pointed object (like a pen tip) to press the RESET button. The display will show "0:00".

7.2 Time Adjustment

To set the current time:

  1. Check if the clock display is consistent with the current time. If recalibration is needed, press and hold the CLOCK button.
  2. While holding CLOCK, press the D+ button to adjust the day of the week.
  3. While holding CLOCK, press the H+ button to adjust the hour.
  4. While holding CLOCK, press the M+ button to adjust the minute.
  5. Release the CLOCK button once the correct time is set.
Diagram showing operation steps for time adjustment and timer settings
Figure 8: Detailed steps for time adjustment and programming.

7.3 Timer Setting (ON/OFF Programs)

The device supports up to 18 ON/OFF program settings. To set a program:

  1. Press the TIMER button once. The word "1 ON" will appear at the bottom left of the screen, indicating the first ON setting.
  2. Press the D+, H+, and M+ buttons to set the desired day(s), hour, and minute for the first ON time.
  3. Press the TIMER button again. The word "1 OFF" will appear, indicating the first OFF setting.
  4. Press the D+, H+, and M+ buttons to set the desired day(s), hour, and minute for the first OFF time.
  5. Repeat steps 1-4 for additional ON/OFF settings (up to 18 pairs). The display will cycle through "2 ON", "2 OFF", "3 ON", "3 OFF", and so on, up to "18 ON", "18 OFF".
  6. If you do not need all 18 settings, press the MANUAL button to clear the extra settings. The display will show "--:--" for cleared settings.
  7. After setting all desired programs, press the CLOCK button to exit programming mode and return to the current time display.

Note: The minimum interval for programming is 1 minute.

7.4 Manual Control (ON/AUTO/OFF)

Press the MANUAL button to cycle through the following modes:

  • ON: The output is continuously ON, overriding any programmed settings.
  • AUTO: The output operates according to the programmed ON/OFF settings.
  • OFF: The output is continuously OFF, overriding any programmed settings.

Ensure the device is in AUTO mode for programmed functions to execute.

8. Maintenance

The EARU Electric Digital Programmable Timer Switch Relay requires minimal maintenance. To ensure optimal performance and longevity:

  • Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to direct sunlight, extreme temperatures, or high humidity.
  • Regularly check wiring connections to ensure they remain secure.
  • The internal lithium battery provides power reserve for settings. If the display is blank after a power outage, the battery may be depleted or the device may need to be reset and reprogrammed.

9. Troubleshooting

ProblemPossible CauseSolution
Device not powering on / LCD blankNo power supply; Internal battery depleted.Check power connections. If power is present, the internal battery might need charging (connect to power for a few hours) or replacement if it's very old. Perform a reset.
Programs not executingDevice is not in AUTO mode; Incorrect programming; Time not set correctly.Press the MANUAL button until "AUTO" is displayed. Review and correct your ON/OFF program settings. Ensure the current time is accurately set.
Output always ON or OFFDevice is in manual ON or OFF mode.Press the MANUAL button until "AUTO" is displayed.
Cannot achieve very short intervals (e.g., 10 times per second)Device limitation.This timer switch has a minimum programming interval of 1 minute. It is not designed for high-frequency intermittent switching.
Need to switch only the Live lineWiring configuration.The device can be wired to switch only the Live line while the Neutral remains continuously connected. Consult a qualified electrician for specific wiring configurations to ensure safety and compliance with local electrical codes.
Need to use with 50-60 VDCIncompatible voltage.This model supports AC/DC 12V or 220V. There is no information indicating support for 50-60 VDC. Using an incompatible voltage can damage the device and pose a safety risk.

10. User Tips

  • The convex buttons are designed to prevent accidental presses, ensuring your settings remain secure.
  • The clear LCD display provides intuitive feedback, making it easy to monitor the time and program status.
  • Thanks to its high-quality construction, this timer switch offers reliable and reassuring performance.
  • The DIN-Rail mounting feature makes installation straightforward and efficient.

11. Frequently Asked Questions (FAQ)

Q: Can this relay be used for constant intermittent circuits with very high frequency (e.g., 10 times per second)?
A: No, this timer switch has a minimum interval of 1 minute for programming. It is not suitable for applications requiring very high-frequency switching.
Q: Does this timer support switching only the Live line, leaving the Neutral continuously connected?
A: Yes, depending on the specific wiring configuration, this device can be set up to switch only the Live line. Always ensure proper wiring by a qualified professional.
Q: Is there a model that works with 50-60 VDC?
A: This model supports AC/DC 12V or 220V. There is no information indicating support for 50-60 VDC. Using an incompatible voltage can damage the device.

12. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.