SUMRY HGX 6.5KW

Contents

SUMRY 6.5KW Off Grid Solar Inverter User Manual

Model: HGX 6.5KW

Pure Sine Wave MPPT Solar Charger LCD Hybrid Inverter

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your SUMRY HGX 6.5KW Off Grid Solar Inverter. This hybrid inverter is designed to efficiently convert solar energy into usable AC power for your home or off-grid applications, featuring a pure sine wave output, an integrated MPPT solar charger, and a user-friendly LCD interface.

Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage to the unit or connected equipment.

2. Key Features

  • Pure sine wave solar inverter for clean and stable power output.
  • Unique glass top cover design with a 6.25-inch LCD display and touchable buttons for easy interaction.
  • Built-in 150A MPPT (Maximum Power Point Tracking) solar charger for optimized solar energy harvesting.
  • Wide PV input voltage range from 55VDC to 450VDC.
  • Smart battery charger design for optimized battery performance and extended lifespan.
  • Configurable AC/Battery input priority via LCD settings to suit various power management needs.
  • Automatic restart function when PV power recovers.
  • Comprehensive protection features: Overload, over temperature, output short circuit, anti-reverse, overcurrent, high/low voltage, and power failure protection.
  • Cold start function for reliable operation in various conditions.
  • Built-in lithium battery automatic activation.
  • Communication ports: RS232/RS485 for data monitoring and control.
  • Optional WiFi monitoring function available for iOS and Android devices via the "Hy-Power" App.
  • Capable of operating without a battery connected, directly powering loads from solar and/or utility.

3. Safety Information

Always observe the following safety precautions during installation, operation, and maintenance of the inverter:

  • Ensure all wiring is performed by qualified personnel in accordance with local electrical codes.
  • Disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.
  • The inverter operates at high voltages (above 50Vac or 75Vdc). Exercise extreme caution.
  • Do not attempt to open or repair the inverter yourself. Refer to qualified service personnel.
  • Ensure proper ventilation around the inverter to prevent overheating.
  • The inverter is equipped with multiple safety protections including:
    • Overload Protection
    • Battery Protection
    • Short Circuit Protection
    • Anti Reverse Protection
    • Overheating Protection
    • Overcurrent Protection
    • High/Low Voltage Protection
    • Power Failure Protection
Diagram showing various safety protections of the inverter
Figure 3.1: All-Round Safety Protection Features

4. Product Overview

4.1 Physical Appearance and Components

The SUMRY HGX 6.5KW inverter features a sleek design with a glass top cover. Key components include the LCD display, touch buttons, and various input/output ports located on the bottom and side panels.

Front, back, and side views of the SUMRY HGX 6.5KW inverter
Figure 4.1: Product Appearance (Front, Back, and Side Views)
Side view of the inverter showing AC input, AC output, PV input, Battery input, and communication ports
Figure 4.2: Inverter Side Panel with Port Labels

4.2 LCD Display and Indicators

The 6.25-inch LCD display provides real-time data and status information. It is complemented by LED indicators and touch-sensitive buttons for navigation and settings adjustment.

Close-up of the inverter's LCD display showing status, charging, and fault indicators, along with function touch buttons
Figure 4.3: LCD Display and Control Interface
  • LCD Display: Shows various operational parameters and settings.
  • Status Indicator: LED light indicating the current operational status.
  • Charging Indicator: LED light indicating battery charging status.
  • Fault Indicator: LED light illuminating in case of an error or fault.
  • Function Touch Buttons: ESC, Up, Down, and Enter buttons for menu navigation and setting adjustments.

5. Setup and Installation

Before beginning installation, ensure you have all necessary tools and safety equipment. Always follow the correct connection order: Battery First, Then Solar Panels.

5.1 Wiring Diagram

The following diagram illustrates the typical wiring connections for the SUMRY HGX 6.5KW inverter in an off-grid solar system. This includes connections for AC input (utility/generator), AC output (loads), PV input (solar panels), and battery input.

Detailed wiring diagram for the SUMRY HGX 6.5KW inverter, showing connections for AC input, AC output, PV input, and battery input with wire color coding.
Figure 5.1: Wiring Diagram and Technical Specifications

Connection Details:

  • AC Input: Connect to a 230VAC utility grid or generator. Frequency range: 50/60Hz.
  • AC Output: Connect to your household appliances. Rated output power: 6500W, Rate Voltage: 230Vac±5%, Pure Sine Wave Inverter.
  • PV Input: Connect your solar panel array. Max PV Array Power: 7200W, MPPT Voltage Range: 55-450VDC, Max. Charging Current: 130A.
  • Battery Input: Connect your 48VDC battery bank (Lithium/Lead-acid). Max. Charging Current: 110A (from AC) / 130A (from Solar).

Important: Correct Connection Order: Battery First, Then Solar Panels.

  1. Connect Battery to MPPT.
  2. Connect Solar Panels to MPPT.

5.2 Battery Compatibility

The inverter is compatible with various battery types and can also operate without a battery, directly powering loads from solar and/or utility.

Diagram showing compatibility with GEL, LI, AGM, USER, and FLD battery types, and the inverter's dimensions.
Figure 5.2: Compatible Battery Types and Inverter Dimensions

Supported battery types include:

  • FLD (Flooded Lead-Acid)
  • GEL (Gel Lead-Acid)
  • SLD (Sealed Lead-Acid)
  • AGM (Absorbent Glass Mat)
  • LI (Lithium-ion)
  • USER (User-defined settings for custom battery types)

The inverter features built-in lithium battery automatic activation and smart battery charger design for optimized performance.

6. Operating Modes

The SUMRY HGX 6.5KW inverter offers flexible operating and output modes to optimize power usage based on your preferences and available energy sources.

Diagram illustrating three operation modes (Solar Priority, Solar and Utility, Only Solar Charging) and two output modes (SUB, SBU).
Figure 6.1: Operation and Output Modes

6.1 Three Operation Modes

  • Solar Priority (CSO): The inverter prioritizes solar energy to power loads. If solar is insufficient, it automatically switches to the grid (utility).
  • Solar and Utility (SNU): This mode offers the fastest charging by utilizing both solar and utility power.
  • Only Solar Charging (OSO): The inverter charges batteries exclusively from solar power.

6.2 Two Output Modes

  • SUB Mode: Solar energy provides power to the loads as the first priority. If solar energy is not sufficient to power all connected loads, utility energy will supply power to the loads at the same time.
  • SBU Mode: Solar energy provides power to the loads as the first priority. If solar energy is not sufficient to power all connected loads, battery energy will supply power to the loads at the same time. Utility power is supplied to the loads only when the battery voltage drops to either a low-level warning voltage or a user-defined setting point (Program 13).

7. Monitoring and Control

The inverter provides multiple ways to monitor its performance and control settings.

7.1 On-Device Monitoring

The integrated 6.25-inch LCD screen displays critical operational data, while LED lights provide quick status updates (status, charging, fault). Touchable buttons allow for direct interaction and configuration.

Close-up of the inverter's LCD display showing status, charging, and fault indicators, along with function touch buttons
Figure 7.1: Get Information at a Glance from LCD Screen

7.2 Remote Monitoring (Optional WiFi)

For enhanced monitoring and control, an optional WiFi module can be connected to the inverter. This allows you to monitor and manage your system remotely via the "Hy-Power" App, available for both iOS and Android devices.

Image showing a smartphone displaying the Hy-Power app interface connected to the SUMRY HGX inverter via an optional WiFi module.
Figure 7.2: Monitor and Control via "Hy-Power" App

The inverter also supports communication via RS232/RS485 ports for integration with other monitoring systems.

Video 7.1: Product Overview and Features Demonstration

8. Specifications

Below are the detailed technical specifications for the SUMRY HGX 6.5KW Off Grid Solar Inverter.

FeatureSpecification
ModelHGX 6.5KW
Battery Voltage48VDC
Output Voltage230VAC
Frequency Range50/60Hz
Max. PV Input Power7600W
MPPT Voltage Range55-450VDC
PhaseSingle phase
Rated Output Power6500W
Battery Mode Output Efficiency94%
Max. Solar Charging Current130A
Max. AC Charging Current110A
Max Charging Current (Total)130A
Dimensions (D*W*H)400*250*89 mm
Net Weight8.5KG
Operating Temperature-5°C to 55°C
Communication PortRS232/WIFI / RS485-BMS
Is Smart DeviceYes
CertificationCE, FCC, RoHS
Wave FormPure sine wave
Work without batteryYes
Work with batteryYes
Main product image with key specifications like 130A Max Charging Current, 7600W Max PV Input Power, 55-450V PV Array Voltage Range, and 50/60Hz Frequency Range.
Figure 8.1: Key Specifications Overview

9. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure no dust or debris accumulates on the ventilation openings.
  • Cooling Fans: The inverter is equipped with three cooling fans to reduce the temperature during charging and operation. Ensure these fans are not obstructed and are functioning correctly.
  • Image showing the three cooling fans on the inverter, designed to reduce temperature during charging.
    Figure 9.1: Three Cooling Fans
  • Connections: Regularly check all electrical connections (PV, battery, AC input/output) to ensure they are secure and free from corrosion.
  • Environment: Ensure the inverter is installed in a dry, well-ventilated area, away from direct sunlight, moisture, and flammable materials.

10. Troubleshooting

This section provides general guidance for common issues. For complex problems, contact technical support.

ProblemPossible CauseSolution
Inverter not turning onNo power from battery or PV; incorrect wiring.Check battery connections and voltage. Verify PV input. Ensure correct wiring sequence (Battery first, then PV).
No AC outputOverload; short circuit; low battery voltage; inverter fault.Reduce load. Check for short circuits in output wiring. Charge battery. Check fault indicator on LCD.
Overheating warning/shutdownInsufficient ventilation; blocked cooling fans; excessive ambient temperature.Ensure adequate airflow around the inverter. Clean cooling fan vents. Relocate inverter to a cooler environment if necessary.
Battery not chargingPV input too low/high; incorrect battery settings; faulty battery.Check PV voltage and current. Verify battery type and charging settings on LCD. Test battery health.
Inverter displays a fault codeSpecific internal error or external condition.Refer to the full product manual (if available) for specific fault code meanings. Contact technical support with the fault code.

11. User Tips

  • Reliable Performance: Users have consistently reported the SUMRY HGX series inverters to be reliable and perform well, making them a trusted choice for solar power systems.
  • Packaging: The product typically arrives with robust and secure packaging, ensuring the device is well-protected during transit.
  • Battery-Free Operation: For systems where a battery is not immediately required, this inverter can operate directly from the grid and solar panels, providing flexibility in system design.
  • Consider WiFi Module: If remote monitoring and control are important for your setup, consider purchasing the optional WiFi module to utilize the "Hy-Power" app.

12. Warranty and Support

The SUMRY HGX 6.5KW Off Grid Solar Inverter comes with a 1-year warranty, ensuring peace of mind regarding product quality and performance.

For technical assistance, warranty claims, or any operational questions, please contact SUMRY Official Store support. You can utilize the RS232/RS485 communication ports for advanced diagnostics or remote support if you have the necessary equipment and software.

Always provide your product model (HGX 6.5KW) and any relevant fault codes or symptoms when contacting support to facilitate quicker resolution.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.