1. Introduction
This manual provides detailed instructions for the assembly, installation, operation, and troubleshooting of your SUMRY Hybrid Solar Inverter. Please read this manual thoroughly before installation and operation, and keep it for future reference.
1.1 Features
- Pure sine wave inverter output.
- Configurable input voltage range for various applications (home appliances, personal computers) via LCD settings.
- Configurable battery charging current based on application needs via LCD settings.
- Configurable AC/Solar Charger priority via LCD settings.
- Compatible with mains voltage or generator power.
- Automatic restart upon AC recovery.
- Comprehensive protection against overload, over temperature, and short circuit.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- Optional WIFI/GPRS for monitoring and control via Smartess App (iOS and Android).
- Built-in 120A MPPT Solar charge controller.
- High PV input voltage range (60-500VDC).
- Dual output capability.
1.2 Basic System Architecture
The inverter/charger integrates inverter, solar charger, and battery charger functions to provide uninterrupted power. A complete system typically includes:
- Solar PV modules
- Battery bank (Lithium or Lead-Acid)
- Utility Grid or Generator
- AC Loads (Home Appliances)
This inverter is capable of powering various home and office appliances, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners.
2. Safety Instructions ⚠ WARNING
This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery. NEVER charge a frozen battery.
- For optimum operation, select appropriate cable sizes as per required specifications.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Strictly follow installation procedures when disconnecting AC or DC terminals.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting, send this inverter/charger back to local dealer or service center for maintenance.
3. Product Overview (Physical Components)
3.1 Components and Indicators
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons (ESC, UP, DOWN, ENTER)
- Power on/off switch
- AC input
- Main output
- Second output
- Battery input
- PV input
- Anti-dust kit
- WIFI communication/RS-232 port
- Battery communication/RS-485 port
4. Installation
4.1 Unpacking and Inspection
Before installation, inspect the unit for any damage. The package should contain:
- The Inverter unit x 1
- User manual x 1
4.2 Preparation
Before connecting any wires, remove the screws located under the machine and detach the bottom cover plate.
4.3 Mounting the Unit
Consider the following points when selecting an installation location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install at eye level for easy LCD display readability.
- Allow approximately 20 cm clearance on the sides and 50 cm above and below for proper air circulation.
- Maintain ambient temperature between 0°C and 55°C for optimal operation.
- The recommended installation position is vertically adhered to the wall.
- Ensure sufficient space around the machine for heat dissipation and wire access.
Install the unit by screwing two M6 screws. This inverter is suitable for mounting on concrete or other non-combustible surfaces only.
4.4 Battery Connection
CAUTION: For safety and compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the table below for recommended cable sizes and torque values.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 2AWG | 25 | 2 Nm |
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for battery connection to reduce risk of injury.
- Remove 18 mm of insulation from positive and negative conductors.
- Apply bootlace ferrules to the ends of positive and negative wires using a proper crimping tool.
- Connect all battery packs as shown in the diagram below.
- Insert battery wires flatly into the inverter's battery connectors. Ensure bolts are tightened to 2 Nm in a clockwise direction. Verify correct polarity (+ to + and - to -) and securely fasten conductors.
4.5 AC Input/Output Connection
CAUTION: Install a separate AC breaker between the inverter and the AC input power source (32A for 3.6KW/4.2KW, 50A for 6.2KW). Do NOT mis-connect input and output connectors.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 3.6KW/4.2KW | 12 AWG | 4 | 1.2 Nm |
| 6.2KW | 10 AWG | 6 | 1.2 Nm |
Follow these steps for AC input/output connection:
- Open DC protector or disconnector first.
- Remove 10mm insulation from conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to polarities (L=LINE (brown or black), N=Neutral (blue)) and tighten terminal screws.
- Insert AC output wires according to polarities (L=LINE (brown or black), N=Neutral (blue)) and tighten terminal screws.
- Ensure all wires are securely connected.
4.6 PV Connection
CAUTION: Install a DC circuit breaker between the inverter and PV modules. Refer to the table below for recommended cable sizes and torque values.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/4.2KW/6.2KW | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection: Ensure the Open Circuit Voltage (Voc) of PV modules does not exceed the max. PV array open circuit voltage of the inverter (500Vdc) and is higher than the min. battery voltage. The MPPT Voltage Range is 60Vdc-450Vdc.
4.7 Communication Connection
The inverter supports communication with lithium batteries via BMS communication protocol (Baud rate: 9600). It also supports Wi-Fi/GPRS cloud communication for monitoring via mobile app or web page.
Lithium Battery Communication
If using a lithium battery, ensure it is matched with the BMS communication protocol. Connect an RJ45 cable between the inverter's BMS communication port and the lithium battery's RS485 communication port. Select "LIB-485" mode in program 05 of the inverter settings.
| Pin number | Port definitions |
|---|---|
| 1 | RS485B |
| 2 | RS485A |
| 3 | NG |
| 4 | NG |
| 5 | NG |
| 6 | NG |
| 7 | RS485A |
| 8 | RS485B |
Wi-Fi/GPRS Cloud Communication