1. Introduction
This manual provides instructions for the safe and effective use of your Gaqqee KWS-2303C or KWS-2301C Type-C Voltage and Current Monitor. These devices are designed to quickly identify and display various electrical parameters such as current, voltage, power, electrical energy, capacity, and timing for Type-C devices.

2. Safety Information
- Do not disassemble or modify the device.
- Keep the device away from water and high humidity environments.
- Avoid extreme temperatures and direct sunlight.
- Ensure proper connection to avoid damage to the device or connected equipment.
- This device is for measurement purposes; do not use it as a power source.
3. Product Overview
3.1 Key Features
- Real-time Monitoring: Displays voltage, current, power, capacity, electrical energy, timing, and CPU temperature (KWS-2303C).
- High-Definition Display: KWS-2303C features a 1.06-inch TFT HD display; KWS-2301C features a 0.77-inch OLED HD display.
- Durable Design: CNC metal case, dustproof and drop-proof.
- Bidirectional Current Test: Supports testing current flow in both directions.
- Fast Charging Protocol Support: Compatible with PD2.0, 3.0, PPS, QC2.0, 3.0, FCP, SCPAFC, PE, DASH VOOC, SuperVOOC (KWS-2301C).
- Data Saving: Supports power-down data saving (KWS-2303C).
- Full Interface Compatibility: Designed for wide compatibility with Type-C devices.
3.2 Components and Display Elements (KWS-2303C)

- Voltage (4-30V)
- Current (0-12A)
- Power (0-360W)
- Data Interface Voltage
- Capacity (0-6666666mAh)
- Energy (0-999999Wh)
- Timing (0-99 hours)
- Current Direction Marker
- Record single maximum power
- Record single maximum current
- Record single maximum voltage
- CPU temperature
- Current Direction Marker (repeated, likely for different views)
- Page curve time
- Voltage per grid
- Current per grid
Note: KWS-2301C has a similar display with core parameters.
4. Specifications
| Parameter | KWS-2303C | KWS-2301C |
|---|---|---|
| Voltage Range | DC 4-30V | DC 4-30V |
| Current Range | 0-12A | 0-12A |
| Power Range | 0-360W | 0-360W |
| Capacity | 0-6666666mAh | 0-99999MAH |
| Electrical Energy | 0-999999Wh | 0-99999WH |
| Timing | 0-99 hours | 0-99 hours |
| Ambient Temperature | Not specified | 50℃ |
| Dimensions | 53 x 20 x 9 mm | 41 x 16 x 9 mm |
| Display Type | 1.06-inch TFT HD | 0.77-inch OLED HD |
| Certifications | CE, RoHS | CE, RoHS |

5. Setup
The Gaqqee Type-C Voltage and Current Monitor is a plug-and-play device. No complex installation is required.
- Connect the male Type-C end of the monitor to your power source (e.g., charger, power bank, computer USB-C port).
- Connect your device (e.g., smartphone, tablet, laptop) to the female Type-C port on the monitor.
- The monitor will automatically power on and begin displaying real-time electrical parameters.


6. Operating Instructions
6.1 Changing Display Pages
The monitor features multiple display pages to show different sets of parameters. To cycle through the display pages:
- Click the button once to switch to the next display page.

6.2 Rotating Screen Orientation
For convenient viewing from different angles, the screen display can be rotated:
- Double-tap the button to rotate the screen display direction.

6.3 Data Recording
The KWS-2303C model supports power-down data saving, allowing you to retain measurement data even after disconnecting the device.

6.4 Fast Charging Test
Both models can be used to test fast charging capabilities of chargers and devices. The KWS-2301C specifically lists support for various fast charging protocols.

6.5 Product Demonstration Video
7. User Tips
- Always ensure your charger and device are compatible with the voltage and current ranges of the monitor to prevent damage.
- For accurate capacity measurements, allow the device to fully charge or discharge through the monitor.
- The metal casing provides good durability, but avoid excessive force or dropping the device.
8. Troubleshooting
8.1 No Display / Device Not Powering On
- Ensure the monitor is correctly plugged into a live power source.
- Verify that the connected device is drawing power.
- Check if the Type-C cables are fully inserted and not damaged.
8.2 Incorrect Readings
- Ensure all connections are secure and stable.
- Test with a different charger or device to isolate the issue.
- Readings might fluctuate slightly during dynamic charging states; observe for stable values.
8.3 Screen Not Rotating / Pages Not Changing
- Ensure you are performing the correct action: single click for page change, double-tap for screen rotation.
- The button might be stuck; gently press it multiple times.
9. Maintenance
- Clean the device with a soft, dry cloth. Do not use liquid cleaners.
- Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Avoid exposing the Type-C ports to dust or debris.
10. Warranty and Support
For warranty information and technical support, please refer to the seller's policies or contact the manufacturer directly. Keep your purchase receipt for any warranty claims.