1. Introduction

Welcome to the PowMr POW-M100-PRO series solar charge controller. This device is designed with advanced Maximum Power Point Tracking (MPPT) technology, offering high performance and reliability for your solar energy system. It features an LCD screen and user-friendly buttons for real-time monitoring of operational data and system status. The controller supports various battery types and can be expanded with parallel operation for larger systems.

The POW-M100-PRO automatically manages battery charging and discharging, optimizing these processes to extend battery life and enhance overall system efficiency. It includes self-diagnostic and electronic protection functions to prevent damage from installation errors or system failures, ensuring system reliability and stability.

Video: PowMr 100A MPPT Solar Charge Controller Unboxing and Feature Overview

2. Important Safety Instructions

WARNING: Carefully read and adhere to all safety instructions.

  • Before installing and operating the controller, please read this user manual thoroughly and keep it for future reference.
  • The installation or operation of the controller should only be performed by individuals who have received proper training and supervision. This includes:
    • Anyone lacking the necessary knowledge, experience, or capabilities for safe installation and operation requirements.
    • Individuals (including children) who may have physical, sensory, or intellectual impairments that could affect safe installation and operation.

Controller Installation and Operation

  • This controller product does not have user-serviceable components; do not disassemble or attempt to repair the controller yourself.
  • Install the controller in a well-ventilated environment with adequate clearance around it.
  • Install the controller on non-combustible walls and ensure there are no flammable materials nearby; it is normal for the controller to generate heat during operation.
  • Place the controller in an environment that is protected from direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
  • Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
  • Do not place any objects on top of the controller.

Battery Installation and Charging

  • Install and charge batteries in well-ventilated or exhaust-ventilated environments.
  • Ensure there are no open flames in the vicinity of the batteries, as batteries emit explosive gases.
  • Battery acid is corrosive; if battery acid comes into contact with the skin, rinse immediately with clean water.
  • Do not charge non-rechargeable batteries. Do not charge lithium batteries when the temperature is below 0°C. Charging frozen batteries is prohibited.
  • Ensure that the equipment is properly configured for the type of battery connected to it.

DC Battery Connections

  • Ensure that the DC system is fully off/powered down by disconnecting all cables and/or new ports from the battery/DC system.
  • Use flexible, multi-strand copper cables with an appropriate cross-sectional area, and connect them to matching fuses or circuit breakers.
  • Connecting the photovoltaic array to the controller is prohibited until the battery is connected first.

Controller Configuration

  • Refer to the battery manufacturer's guide and specifications to ensure the battery is suitable for the controller and confirm the recommended charging settings.
  • Integrated charging modes include adaptive charging logic, which is suitable for most battery types.

3. Product Features

  • Integrated Charging Presets: Adaptive charging logic suitable for most battery types (flooded lead-acid, gel-sealed lead-acid, lithium). Specific parameters are detailed in Section 5.5.
  • Versatile Application: Compatible with 12V/24V/36V/48V system voltages.
  • Multi-Stage Charging Algorithm: Optimizes each charging cycle and maintains battery capacity with preset charging parameters.
  • Maximum Power Point Tracking (MPPT) Technology: Tracks the maximum power point voltage (Vmp) of the solar array to maximize energy collection throughout the day.
  • High-Efficiency Charging: MPPT technology boasts a tracking efficiency of up to 99.9% and a peak conversion efficiency of up to 97%, reducing power consumption and heat generation.
  • Supports Up to 12 Units in Parallel: Allows for easy expansion of solar panel configuration and energy storage capacity. Refer to Section 6 for detailed guidelines.
  • Adaptive Boost Charging: Monitors battery response during the initial charging phase to determine optimal boost stage duration, ensuring full charge without overcharging.
  • Durable and Secure: Includes protections against photovoltaic input overcurrent, photovoltaic array short circuit, reversed photovoltaic polarity, battery overvoltage, battery overdischarge, and over-temperature.
  • External Temperature Probe Configuration: Enhances precision in battery temperature monitoring for accurate temperature compensation.
  • Forced Air Cooling: Built-in cooling fan for efficient heat dissipation, improving operational efficiency.
  • Lithium Battery Activation: Adjusts charging cycles for lithium batteries and activates protected lithium batteries using solar panel energy (current not exceeding protection limits).

Warning: Do not charge lithium batteries when the temperature is below 0°C.

PowMr 100A MPPT Solar Charge Controller with dimensions and key features

Image: PowMr 100A MPPT Solar Charge Controller showing dimensions (12.41in height, 7.68in width, 3.15in depth) and key features like 100A MPPT, 12V/24V/36V/48V battery auto, 160VDC Max PV Input Voltage, Parallel Function (up to 12 units), Pure Sine Wave, 4-States Charging Model, and Lithium battery support.

4. Setup and Installation

4.1 Unpacking and Inspection

Before installation, carefully inspect the packaging for any signs of damage. After unpacking, verify that all contents are present and undamaged. The package should contain:

  • Controller
  • User Manual (this document)
  • Installation screws
  • Parallel connector (if applicable)
  • External temperature sensor (if included)

4.2 Choosing the Installation Location

Select an installation location that meets the following criteria:

  • Ventilation: Install in a space with good natural ventilation or exhaust.
  • Sunlight: Avoid direct sunlight exposure.
  • Clearance: Ensure a minimum clearance of 75mm around the top, bottom, and both sides of the controller for proper airflow.
  • Surface: Mount the controller on a non-combustible wall. Ensure no flammable materials are nearby. The controller generates heat during operation, which is normal.
  • Parallel Installation: When installing multiple controllers in parallel, ensure they are at the same horizontal height with a minimum spacing of 200mm between units.

4.3 Wiring Precautions

  1. Installation and wiring must be carried out by a certified electrician.
  2. Follow the wiring sequence: Battery first, then PV Input.
  3. To prevent short-circuits and polarity reversal, ensure positive (+) cables connect to positive (+) terminals and negative (-) cables to negative (-) terminals.
  4. Tighten all cable connections to minimize transition resistance and prevent overheating. Use cables appropriate for the circuit's current rating.

4.4 Installation and Wiring Guidelines

WARNING: Risk of Electric Shock! Before wiring, ensure that all power sources are turned off and follow relevant inspection and operation procedures.

  1. Step 1. Install the controller: Mount the controller vertically with its ports facing downward. Secure it to the wall using the four mounting holes and screws. It is recommended to use the two upper screws for initial hanging, then add the two lower screws, and finally tighten all four.
  2. Step 2. Battery Wiring: Connect the battery to the controller using appropriate cables.
  3. Step 3. PV Wiring: Connect the photovoltaic array to the controller using appropriate cables.
  4. Step 4. Temperature Probe Connection: Connect the temperature probe wire to the controller and securely fix the probe end to the battery using insulation tape.
  5. Step 5. Pre-Startup Check: Refer to the wiring diagram below. If all connections are accurate and securely connected, close the circuit breakers in the order of Battery and PV Input circuitry.
Solar Connect Diagram for PowMr MPPT Solar Charge Controller

Diagram: Solar Connection showing the MPPT controller connected to a solar array, battery (12V/24V/36V/48V), load, and inverter. Max. PV Array Open-Circuit Voltage 160V. Maximum Input Power: 12V System 1200W, 24V System 2400W, 36V System 3600W, 48V System 4800W. Supports Parallel Connection up to 12 units.

Note on Wiring:

  • All wiring work must be carried out by professionals.
  • For safe operation, circuit breakers of appropriate specifications must be installed on all cables connected to the controller, and connections must be tight.
  • Ensure all circuit breakers are in the off position before completing any wiring.
  • Connect positive cable terminals to positive ports and negative cable terminals to negative ports.
  • These notes also apply to PV ports and DC output ports.

5. Operation Guide

5.1 Operation Interface Overview

The LCD display provides real-time information about the system. A short press of the PV/SET key will cycle through photovoltaic parameters.

PowMr MPPT Solar Charge Controller LCD Display

Image: Front view of the PowMr MPPT Solar Charge Controller, highlighting the LCD display and control buttons (PV/SET, BAT/▲, BAT/▼).

No.Function
1Day/Night Indicator Icon (presence of photovoltaic input)
2Battery Remaining Capacity Indicator
3Charging in Progress Indicator
4Photovoltaic Input Voltage/Power/Operating Mode/Fault Codes
5Current Battery Voltage/Charging Current/Device Temperature/Battery Calibration Voltage/Parallel Communication Code/Battery Type/Boost Charging Voltage/Float Charging Voltage/MPP Tracking Return Voltage

5.2 Button Functions

ButtonDescription
PV/SET (Browsing Mode)Switch photovoltaic input parameters
PV/SET (Setup Mode)Confirm settings
BAT/▲ (Browsing Mode)Short Press: Switch battery parameters, move to the next item
Long Press: Enter battery parameter settings
BAT/▲ (Setup Mode)Increase value/return to the previous item and move to the next
BAT/▼ (Browsing Mode)Switch battery parameters, return to the previous item
BAT/▼ (Setup Mode)Decrease value/return to the previous item
Long press BAT/▼ to restore factory settings.

Note: "Setup Mode" for BAT/▲ and BAT/▼ specifically refers to setting battery parameters.

5.3 Overview of Photovoltaic Parameters

A short press of the PV/SET key will cycle through the following data on the left side of the display:

  • PV Input Voltage
  • PV Input Power
  • Operating Mode/Fault Codes

Operating Modes:

Mode CodeDescription
3.0Night Mode, not charging
4.0Fast Charging Mode (MPPT Mode)
7.0Boost Charging Mode
8.0Float Charging Mode

Note: In the event of a fault, the Operating Mode section will display a fault code. Refer to Section 8.2 for details.

5.4 Overview of Battery Parameters

In browsing mode, use the BAT/▲ and BAT/▼ keys to scroll through battery parameters. Long-press the BAT/▲ key to enter parameter setting mode. Use BAT/▲ and BAT/▼ to adjust values, then press PV/SET to confirm.

  • Current Battery Voltage
  • Charging Current
  • Device Temperature
  • Battery Type
  • Parallel Communication Code
  • Calibrated Battery Voltage
  • Boost Charging Voltage
  • Float Charging Voltage
  • MPP Tracking Return Voltage

5.5 Battery Type Setting

Select the battery type based on your connected batteries. Long-press BAT/▲ to enter setup, use BAT/▲ and BAT/▼ to toggle options, and PV/SET to save.

OrderDisplayBattery Type
1SELSealed Lead-Acid Battery
2GELGel Sealed Lead-Acid Battery
3FLdFlooded Lead-Acid Battery
4L044-Series LiFePO4 Battery
5L077-Series LiFePO4 Battery
6L088-Series LiFePO4 Battery
7L1515-Series LiFePO4 Battery
8L1616-Series LiFePO4 Battery
9N033-Series Lithium-Ion Battery
10N066-Series Lithium-Ion Battery
11N077-Series Lithium-Ion Battery
12N1313-Series Lithium-Ion Battery
13N1414-Series Lithium-Ion Battery
14USEUser-defined

5.6 Custom Configuration of Charging Voltage

If "USE" (User-defined mode) is selected for battery type, the following charging parameters can be manually set:

  • Nominal System Voltage (12V/24V/36V/48V)
  • Boost Charging Voltage (9.0~17.0V for 12V battery)
  • Float Charging Voltage (9.0~17.0V for 12V battery)
  • MPP Tracking Return Voltage (9.0~17.0V for 12V battery)

Note: For 24V/36V/48V systems, the voltage ranges are 2/3/4 times the specified 12V range, respectively. The LCD screen only displays 12V equivalent voltage values.

Setting Steps:

  1. Use BAT/▲ and BAT/▼ keys to select the parameter you want to set.
  2. Long-press the BAT/▲ key to enter the setting mode for the selected parameter.
  3. Use the BAT/▲ and BAT/▼ keys to adjust the voltage value.
  4. Press the PV/SET key to confirm and save.

Logic for setting custom battery voltage parameters: Maximum Charging Voltage > Boost Charging Voltage > Float Charging Voltage > MPP Tracking Return Voltage.

6. Parallel Operation Guide

The PowMr MPPT Solar Charge Controller supports parallel operation, allowing you to expand your solar energy system by connecting up to 12 units. This increases the charging rate and allows for more MPPT inputs.

6.1 Parallel Operation Schematic

Solar Connect Diagram for PowMr MPPT Solar Charge Controller showing parallel connection

Diagram: Solar Connection showing multiple MPPT controllers (#01, #02, ... #n) connected in parallel to separate solar arrays and a common battery bank. Parallel communication cables, positive power cables, and negative power cables are indicated.

Main Modules:

  • Controller: Designed for both standalone and parallel operation. Communication between controllers is achieved via communication lines. Parallel controllers should be installed at the same horizontal level.
  • Solar Array: Each controller must be connected to a separate solar array. One solar array cannot be simultaneously connected to more than one controller. The input power to each controller should not exceed its rated input power.
  • Battery Bank: All parallel controllers are connected to the same battery bank.

6.2 Parallel Installation and Wiring

  1. Step 1. Install parallel devices: Install parallel devices at the same height level with a minimum distance of approximately 75mm between devices.
  2. Step 2. Connect communication cables.
  3. Step 3. Connect all parallel controllers to the same battery bank.
  4. Step 4. Connect each controller to its respective photovoltaic array.
  5. Step 5. Configure Master/Slave: After completing wiring, power on by closing the battery circuit breaker. Set the master and slave configurations as defined in Section 5.5 (Parallel Communication Code Setting). Then, configure the entire parallel system through the master controller.

Note on Parallel Wiring:

  • All wiring work must be carried out by professionals.
  • For safety and compliance, cables connected to the controller must have corresponding circuit breakers installed, ensuring tight connections.
  • Before completing all wiring, ensure that all circuit breakers are in the off position.
  • Connect positive cable terminals to positive ports and negative cable terminals to negative ports.

7. Maintenance

To ensure optimal performance and longevity of your PowMr MPPT Solar Charge Controller, we recommend conducting the following checks and maintenance at least twice a year:

  1. Ensure the controller is securely mounted in a clean and dry environment.
  2. Ensure proper airflow around the controller and clean any dust or debris from the heat sinks.
  3. Inspect all exposed wires for insulation damage (e.g., from sun exposure, friction, dryness, insects, or rodents). Repair or replace damaged wires as necessary.
  4. Tighten all terminals and check for loose, broken, or burnt cable connections.
  5. Confirm that all system components are properly grounded.
  6. Ensure all terminals are free from corrosion, insulation damage, high temperatures, or signs of burning/discoloration, and tighten terminal screws.
  7. Check for dirt, nesting insects, and corrosion. If present, clean promptly.

WARNING: Risk of electric shock! Before performing any maintenance operations, ensure that all power sources are turned off and follow the relevant check and operation guidelines.

8. Troubleshooting

When a fault occurs, the controller's display will show a fault code to help identify and resolve the issue. Refer to the table below for common fault codes and their solutions.

Fault CodePossible CausesSolutions
18Low input photovoltaic voltageIncrease the number of solar panels or connect them in series to raise the photovoltaic input voltage.
60Overtemperature protectionAllow the device to cool below the recovery temperature to resume normal charging and discharging.
63High battery voltageMeasure and confirm if the battery voltage exceeds the rated voltage. If so, close the photovoltaic array circuit breaker.
65Low battery voltageCharge the battery until the voltage exceeds the undervoltage termination voltage. Refer to "5.5 Battery Type Setting" for specific values.
71High input photovoltaic voltageReduce the number of connected photovoltaic arrays to lower the photovoltaic input. Alternatively, modify the series and parallel connection to decrease voltage or current values.
73Overcharging currentReduce the number of connected photovoltaic arrays to lower the photovoltaic input. Alternatively, modify the series and parallel connection to decrease voltage or current values.

9. Specifications

The following table details the technical specifications for the PowMr POW-M100-PRO MPPT Solar Charge Controller.

PowMr MPPT Solar Charge Controller detailed specifications

Image: Detailed specifications table for the PowMr MPPT Solar Charge Controller, including rated charging current, maximum efficiency, MPPT efficiency, temperature compensation, self-consumption, operating temperature range, humidity range, altitude, protection level, dimensions, and net weight.

Model: POW-M100-PRO
Solar Input Specification
Max. Solar Array Open-Circuit Voltage160V
Maximum Input Power
For 12V System1200W
For 24V System2400W
For 36V System3600W
For 48V System4800W
Battery Charging Specification
Charging TechnologyMPPT
Charging Algorithm3 Stages
Nominal System Voltage12V/24V/36V/48V
Battery Voltage Range9~60V
Rated Charging Current100A
Maximum Efficiency≤98%
MPPT Efficiency>99%
Temperature Compensation-3mV/°C/2V (default)
Self-Consumption44mA/12V; 26mA/24V; 18mA/36V; 12mA/48V
Environment Specification
Operating Temperature Range-35°C~+45°C
Humidity Range≤95%, Non-condensing
Altitude<3000m
General Specification
Protection LevelIP32
Dimensions315x195x80mm
Net Weight2.7kg

10. User Tips

  • USB Output: The PowMr POW-M100-PRO solar charge controller does not feature a built-in USB output. It is primarily designed for efficient solar charging and battery management.
  • Parallel Communication: When setting up multiple units in parallel, ensure each controller has a unique communication code to prevent conflicts and ensure proper master/slave designation.
  • Battery Type Configuration: Always configure the controller to match your specific battery type (e.g., Sealed, Gel, Flooded, LiFePO4, Lithium-Ion) for optimal charging and battery longevity. Incorrect settings can damage your batteries.

11. Warranty and Support

PowMr provides quality products and support. Please note the following conditions regarding warranty responsibilities:

The company reserves the right not to assume quality warranty responsibilities under these circumstances:

  • Damage caused by improper transportation, storage, installation, or usage.
  • Damage caused by non-professionals or untrained personnel installing and operating the equipment.
  • Damage resulting from non-compliance with the instructions and safety warnings in this document.
  • Damage caused by operation in environments that do not meet the specified requirements.
  • Damage due to operation beyond the parameter ranges specified in technical specifications.
  • Damage resulting from unauthorized disassembly, product alteration, or software code modification.
  • Damage caused by abnormal natural conditions (force majeure) such as lightning, earthquakes, fires, or storms.
  • Any damage resulting from failure to adhere to local standards and regulations during installation and operation.
  • Products outside the warranty period.

For technical support or inquiries, please contact:

  • Email: support@powmr.com
  • Web: www.powmr.com
  • Tel/Fax: +86 755-28219903
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

A PDF version of the user manual is available for download from the seller's resources.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.