1. Introduction
The ZEEWEII DSO2512G is a versatile 2-in-1 handheld digital oscilloscope and signal generator designed for a wide range of applications. It integrates ARM and FPGA chip technology for high-speed signal acquisition and data processing, ensuring a smooth and efficient user experience. This manual provides essential information for setting up, operating, and maintaining your device.
2. Package Contents
Please check the package carefully to ensure all items are present:
- DSO2512G Handheld Oscilloscope
- 2 x P6100 Probes
- 1 x USB Type-C Cable
- 1 x Video Cable
- 1 x Signal Generator Cable
- 1 x Storage Bag
- 1 x User's Manual (this document and the linked PDF)

3. Product Overview and Features
The DSO2512G combines the functionalities of a digital oscilloscope and a signal generator in a compact, portable design. Key features include:
- Dual Channel Oscilloscope: 120M bandwidth (CH1 only), 60M (CH1+CH2)
- Integrated Signal Generator: Outputs various waveforms up to 10MHz (sine) or 2MHz (others).
- 2.8-inch Screen: Clear 320*240 resolution display.
- High-Performance Processor: Utilizes ARM and FPGA chips for fast signal acquisition and data processing.
- XY Mode: For phase comparison of two signals.
- Video Output: Project the screen to a larger display via AV cable.
- One-Click AUTO Function: Simplifies waveform setup.
- CURSOR Function: For precise measurements.
- FFT Spectrum Analysis: Supports logarithmic, linear, and music spectrum display modes.
- Multiple Trigger Modes: Auto, Normal, Single with Rise/Fall types and Manual/Auto level.
- Waveform Storage: Save and view up to 250 waveforms.
- Anti-Burn Protection: Enhanced durability.



4. Setup
Before using your DSO2512G, please follow these setup steps:
- Charge the Device: Connect the oscilloscope to a 5V Type-C power source using the provided USB cable. The internal 4000mAh lithium battery should be fully charged before first use.
- Connect Probes: Attach the P6100 probes to the BNC connectors on the top of the oscilloscope. Ensure a secure connection.
- Power On: Press and hold the power button to turn on the device.
- Initial Calibration: It is recommended to perform an initial probe calibration using the built-in signal generator's square wave output.
For more detailed setup instructions and advanced configurations, please refer to the official user manual PDF available at: https://www.mediafire.com/folder/ilmq0c04pt9l7/dso2512g

5. Operating Instructions
5.1. Oscilloscope Functions
- One-Click AUTO: Press the 'Auto' button to automatically adjust the time base and vertical sensitivity for a stable waveform display.
- CURSOR Function: Use the cursor controls to precisely measure voltage and time parameters on the waveform.
- XY Mode: This mode is used for displaying the relationship between two signals, often for phase comparison. Select 'XY mode' from the menu to activate.
- Trigger Modes: The device supports Auto, Normal, and Single trigger modes. Trigger types include Rise and Fall edges, with adjustable trigger levels (Manual/Auto).
- Persistence: Adjust the persistence setting (None, 1s, or Infinite) to observe signal changes over time or capture infrequent events.
- Waveform Save/View: One-click to save the current screen waveform. Enter the waveform preview page to browse saved waveforms. Up to 250 waveforms can be saved and unwanted ones can be deleted.
- FFT Spectrum Analysis: The FFT (Fast Fourier Transform) function converts time-domain waveforms into frequency-domain waveforms, useful for harmonic analysis. It supports three display modes: logarithmic, linear, and music spectrum.
- Video Output: Connect an AV signal cable to the device to project the oscilloscope screen onto a TV or other larger display.





5.2. Signal Generator Functions
The bottom of the oscilloscope features a signal generator capable of outputting various waveforms with a 2.5V amplitude.
- Waveform Types: Sine waves, square waves, triangle waves, half waves, and singh waves.
- Frequency Range: Sine waves: 0~10MHz; Other waveforms: 0~2MHz.
- Accuracy: Up to 0.1Hz.
- Connection: The red hole is for the signal output, and the black hole is for GND (Ground).

5.3. Applications
The DSO2512G is suitable for a variety of uses, including:
- Basic R&D
- Car repair
- Home appliance repair
- Power supply debugging
- Sound fever analysis
- Inverter testing
- 220V mains analysis
- Supports 100:1 probes for higher voltage measurements

5.4. Product Demonstration Video
Watch this video for a visual demonstration of the DSO2512G's features, including time base and vertical sensitivity adjustments, 120M signal testing, 220Vrms mains measurement, Roll mode, Single trigger, Dual channel mode, XY mode, Persistence, Signal generator functions, FFT, and waveform Save/View.
6. Specifications
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Model | DSO2512G | Coupling | AC/DC |
| Channels | 2 | Measurement | 14 types |
| Screen size | 2.8inch | Precision of V | ±2% |
| Resolution | 320*240 | XY mode | Support |
| Bandwidth | 120M(CH1) 60M(CH1+CH2) | Screenshot | Support |
| Sampling rate | 500M | Frequency | ±0.01% |
| Rise time | <3ns | Single | Support |
| StorageDepth | 128K | FFT | Support |
| Impedance | 1MΩ | Wave out vol | 2.5V |
| Time base | 5ns – 10s | Wave out freq | 10MHz(sin) 2MHz(other) |
| Vertical sensitivity | 10mV/div~10V/div | Shell size | width*hight*thickness 82 *137 *38mm |
| Max voltae | ±40V (x1) ±400V (x10) | Language | CN/EN |
| Trigger mode | Auto/Normal | Charging | Type-c 5V |
| Trigger type | rise/fall | Battery | 4000mAh |
| Display mode | YT / Roll | Weight | ~286g |
| Persistence | None/1s /∞ |

7. Troubleshooting
If you encounter issues with your DSO2512G, please refer to the following common problems and solutions:
- Device not turning on:
- Ensure the battery is fully charged. Connect the device to a 5V Type-C power source.
- Check the power button for proper function.
- No signal detected:
- Verify that probes are correctly connected to both the oscilloscope and the circuit under test.
- Check probe settings (e.g., 1X/10X switch) and ensure they match the oscilloscope's input settings.
- Use the 'Auto' button to automatically adjust settings.
- Ensure the signal source is active and within the oscilloscope's measurement range.
- Inaccurate readings:
- Perform probe compensation/calibration.
- Check for proper grounding of the oscilloscope and the circuit.
- Ensure the correct vertical sensitivity and time base settings are selected.
- Signal generator not outputting:
- Verify the signal generator cable is correctly connected to the output port (red for signal, black for GND).
- Check the frequency and amplitude settings in the signal generator menu.
- Ensure the signal generator function is enabled.
If the problem persists, consult the full user manual PDF or contact customer support.
8. User Tips
Here are some tips to enhance your experience with the DSO2512G:
- Probe Calibration: Always calibrate your probes before critical measurements to ensure accuracy. Use the built-in signal generator's square wave for this purpose.
- Understanding Triggering: Experiment with different trigger modes (Auto, Normal, Single) and types (Rise, Fall) to stabilize various waveforms, especially for capturing single-shot events.
- Utilize XY Mode: For comparing the phase relationship between two signals, the XY mode is invaluable. It can help visualize Lissajous figures.
- Waveform Storage: Make use of the waveform save feature to capture and review important signals for later analysis or comparison.
- External Display: For collaborative work or clearer viewing, connect the oscilloscope to a larger screen using the video output function.
9. Maintenance
Proper maintenance will ensure the longevity and optimal performance of your DSO2512G:
- Cleaning: Use a soft, dry cloth to clean the device. For stubborn dirt, a slightly damp cloth with mild detergent can be used, but ensure no liquid enters the device. Do not use abrasive cleaners or solvents.
- Storage: Store the oscilloscope in a cool, dry place, away from direct sunlight, extreme temperatures, and high humidity. Use the provided storage bag for protection.
- Battery Care: To prolong battery life, avoid fully discharging the battery frequently. If storing for an extended period, charge the battery to about 50-70% and recharge every few months.
- Probe Care: Handle probes carefully. Avoid bending or twisting the cables excessively. Keep probe tips clean and protected when not in use.
10. Warranty and Support
Your ZEEWEII DSO2512G comes with a standard manufacturer's warranty. For specific warranty terms, duration, and conditions, please refer to the documentation provided with your purchase or contact the seller directly. If you require technical assistance, troubleshooting beyond this manual, or have questions regarding your device, please reach out to ZEEWEII Official Store customer support.