SUMRY MPS VIII ECO

Contents

SUMRY MPS-VIII ECO Series On/Off Grid Solar Inverter User Manual

Model: MPS VIII ECO (available in 3.6KW, 4.2KW, 6.2KW variants)

Brand: SUMRY

1. Introduction

This manual provides essential information for the installation, operation, and maintenance of your SUMRY MPS-VIII ECO Series On/Off Grid Solar Inverter. This high-efficiency pure sine wave inverter is designed to convert reliable, clean AC energy for both on-grid and off-grid living, supporting various power requirements (3.6KW, 4.2KW, 6.2KW models). It features an integrated MPPT solar charge controller and supports multiple battery types, including Lithium and LiFePo4.

2. Important Safety Instructions

Please read all instructions and cautionary markings on the unit and in this manual before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.

  • Installation must be performed by qualified personnel in accordance with all local electrical codes.
  • Ensure all power sources (AC, solar, battery) are disconnected before performing any wiring or maintenance.
  • The inverter generates high voltage. Do not open the unit or attempt repairs unless you are a qualified technician.
  • Do not expose the inverter to rain, snow, spray, or any liquids.
  • Ensure proper ventilation around the inverter to prevent overheating.
  • Use appropriate wiring gauges and circuit breakers as specified in the installation section.

3. Product Overview

The SUMRY MPS-VIII ECO Series inverter is a versatile unit designed for hybrid solar power systems. It features a robust casing, an intuitive LCD display, and various connection ports for seamless integration into your energy setup.

3.1. Key Features

  • Pure sine wave output for sensitive electronics.
  • Configurable input voltage range for home appliances and personal computers.
  • Configurable battery charging current and AC/Solar charger priority.
  • Compatible with utility mains or generator power.
  • Automatic restart upon AC recovery.
  • Comprehensive protection: Overload, Over temperature, Short circuit, High/Low Voltage, Anti-Reverse, Power Failure.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
  • Optional WIFI/GPRS module for remote monitoring and control via a dedicated app.
  • Built-in 120A MPPT Solar charge controller.
  • Supports 24VDC or 48VDC battery systems.
  • High PV input voltage range (60-450VDC or 60-500VDC depending on model).
  • Dual AC output (Main Out and Second Out).

3.2. Physical Components

The inverter features a clear LCD display and function buttons on the front panel for easy configuration and monitoring. The rear panel houses all necessary connection terminals and communication ports.

SUMRY Inverter Product Overview
Figure 1: SUMRY Inverter Product Overview (Front, Back, Side, and Perspective Views)
SUMRY Inverter LCD Display and Function Keys
Figure 2: LCD Display, LED Indicators, and Function Keys

LED Indicators

LED IndicatorMessages
INV/AC (Green, Solid On)Output is powered by utility in Line mode.
INV/AC (Green, Flashing)Output is powered by battery or PV in battery mode.
CHG (Green, Solid On)Battery is fully charged.
CHG (Green, Flashing)Battery is charging.
FAULT (Red, Solid On)Fault occurs in the inverter.
FAULT (Red, Flashing)Warning condition occurs in the inverter.

Function Keys

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

4. Specifications

The following table outlines the general technical specifications for the SUMRY MPS-VIII ECO Series Inverter. Please note that specific values may vary slightly between 3.6KW, 4.2KW, and 6.2KW models and voltage variants (110VAC/220VAC).

FeatureSpecification
Model NumberMPS VIII ECO
Continuous Power3.6KW, 4.2KW, 6.2KW (model dependent)
Output Power Range1 - 200 KW
WaveformPure Sine Wave
AC Output Voltage110VAC - 50Hz/60Hz or 220VAC - 50Hz/60Hz (model dependent)
Battery Voltage24VDC or 48VDC (model dependent)
Control TypeMPPT
Max Solar Charging Current80A (some models up to 120A)
Max Charge Current for Battery60A (some models up to 100A)
MPPT Voltage Range60-450VDC (some models 60-500VDC)
Nominal DC Voltage / Max. DC Voltage360VDC / 500VDC
Max. PV Input Power4200W (for 3.6KW model), 6000W (for 6.2KW model)
Supported Battery TypesLithium, LiFePo4, Lead Acid
Communication InterfaceRS232 (Standard), WIFI (Optional)
Dimensions (D*W*H)420*350*110 mm
WeightApprox. 10KG
CertificationCE, FCC

5. Installation

Proper installation is crucial for the safe and efficient operation of your inverter. Always ensure all power sources are disconnected before beginning installation.

5.1. System Architecture

The inverter integrates solar, battery, and utility/generator power to supply your home appliances. The basic system architecture is illustrated below.

On/Off Grid Solar Inverter System Diagram
Figure 3: On/Off Grid Solar Inverter System Diagram. Shows connections for Solar Panels, Generator/Utility, Battery, and Home Appliances. Nominal DC Voltage/Max.DC Voltage: 360VDC/500VDC. MPPT Voltage Range: 60VDC-450VDC. Max. PV Input power: 4.2KW/6KW. Nominal AC Output Voltage: 120VAC (100/105/115V). AC Start-Up Voltage / Auto Restart Voltage: 110VAC/120VAC.
Basic System Architecture and Comprehensive Protections
Figure 4: Basic System Architecture illustrating power flow and comprehensive protection features.

5.2. Wiring Connections

Refer to the detailed wiring diagram for your specific model. The following diagram provides an example for a 3.6KW model. Ensure all connections are secure and use the recommended cable gauges and breakers.

Wiring and Technical Specifications for 3.6KW Inverter
Figure 5: Wiring and Technical Specifications for 3.6KW Model. This diagram details connections for AC In, Main Out, Second Out, Battery, and PV In. It also specifies Max PV Input Power: 4200W, Nominal DC Voltage/Max. DC Voltage: 360/500VDC, MPPT Range: 60-450VDC, Start-up Voltage/Initial Feeding Voltage: 90VDC/120VDC, PV Wire: 12AWG, AC Input Voltage: 110VAC/120VAC, Frequency: 49-51Hz, Max. AC Input Current: 40A, Suggested cable: 12AWG/1.2Nm, Battery Type: 24V Lithium/Lead acid, Max Solar Charging Current: 120A, Max AC Charging Current: 100A, Battery Wire: 2AWG, Support batteryless mode, AC Output Power: 3600W, Rate Voltage: 120Vac (100/105/115V settable), Max. Main Load: 3600W, Max. Second Load (battery mode): 1200W, Suggested Cable: 12AWG, Recommended breaker: 32A. Wiring color code: Red for Live/Positive, Blue for Neutral/Negative, Green for Earth.

5.2.1. Battery Connection

Connect the battery bank to the inverter's BATTERY terminals (+ and -). Ensure correct polarity. Use appropriate battery cables (e.g., 2AWG for 3.6KW model) and fuses/breakers.

5.2.2. AC Input/Output Connection

Connect the AC input (utility or generator) to the AC IN terminals. Connect your loads to the MAIN OUT and SECOND OUT terminals. The inverter supports 110VAC or 220VAC output depending on the model. Ensure proper grounding.

5.2.3. Solar Panel Connection

Connect your solar panel array to the PV IN terminals (+ and -). Ensure the total PV voltage and current are within the inverter's specifications (e.g., MPPT range 60-450VDC, Max. PV Input Power 4200W for 3.6KW model). Solar panels are recommended to be connected in series.

5.3. Communication Interfaces

The inverter includes RS232/RS485 communication ports as standard, and an optional WIFI module for remote monitoring.

RS232/RS485 and WIFI Communication Interface
Figure 6: RS232/RS485 (Standard) and WIFI (Optional) Communication Interface. This diagram shows the pin definitions for the BMS interface (RJ45 CN1 for RS232/WIFI, RJ45 CN2 for RS485). Note: For 485 communication with lithium battery BMS, only PACE and PYLONTECH's BMS are allowed.

5.4. Installation Demonstration Video

Watch this video for a visual guide on unboxing, connecting the inverter to a battery, and demonstrating its power output with various appliances.

Video 1: SUMRY Inverter Unboxing and Basic Operation Demonstration

6. Operating Instructions

The inverter's operation can be configured and monitored via the LCD display and optional mobile app.

6.1. LCD Display and Button Functions

Use the function keys (ESC, UP, DOWN, ENTER) to navigate through the LCD menu and configure settings such as input voltage range, battery charging current, and AC/Solar charger priority. Refer to Figure 2 for key descriptions.

6.2. Charging and Output Modes

The inverter offers various configurable modes to optimize energy usage based on your preferences and available power sources.

Sectional Charging/Output Source Priority
Figure 7: Sectional Charging/Output Source Priority. This diagram illustrates the four Charging Modes (Solar First, Mains First, Hybrid Charge, Only Solar) and four Output Modes (Solar First, Mains First, Inverter First, Hybrid Output).

6.2.1. Charging Modes

  • Solar First: Prioritizes solar power for battery charging.
  • Mains First: Prioritizes utility/generator power for battery charging.
  • Hybrid Charge: Uses a combination of solar and mains power for charging.
  • Only Solar: Exclusively uses solar power for charging.

6.2.2. Output Modes

  • Solar First: Prioritizes solar power to supply loads.
  • Mains First: Prioritizes utility/generator power to supply loads.
  • Inverter First: Prioritizes battery power (via inverter) to supply loads.
  • Hybrid Output: Dynamically switches between available power sources to supply loads.

6.3. Remote Monitoring (Optional WIFI/GPRS)

With the optional WIFI/GPRS module, you can monitor and control your inverter remotely using the dedicated 'smartess' mobile application, available for both iOS and Android devices.

Monitor and control via smartess App
Figure 8: Remote monitoring and control via the 'smartess' App with optional WIFI/GPRS module.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Keep the inverter clean and free from dust. The NM-ECO-LV series features a built-in anti-dust kit.
  • Ensure ventilation openings are not blocked.
  • Periodically check all wiring connections for tightness and signs of corrosion.
  • Monitor the LCD display for any fault or warning messages.
  • Inspect batteries regularly according to their manufacturer's guidelines.

8. Troubleshooting

This section provides solutions for common issues. For complex problems, contact technical support.

8.1. Common Protections

The inverter is equipped with comprehensive protection features to safeguard itself and your system.

Comprehensive Protections
Figure 9: Comprehensive Protections including Overload, Overheating, High/Low Voltage, Battery Protection, Short Circuit, Overcurrent, Anti-Reverse, and Power Failure Protection.

8.2. Troubleshooting Guide

  • Inverter not turning on: Check battery connections, DC breaker, and ensure sufficient battery voltage.
  • No AC output: Verify AC input connection, check AC breakers, and ensure the inverter is not in fault mode (check FAULT LED).
  • Battery not charging: Check solar panel connections, PV input voltage, and AC input (if AC charging is enabled). Verify charging mode settings on the LCD.
  • Overload warning: Reduce the connected load. The inverter will typically attempt to restart after an overload.
  • Over temperature warning: Ensure adequate ventilation around the inverter. Clear any obstructions from cooling fans.

9. User Tips

  • Battery Compatibility: The inverter supports 24VDC or 48VDC battery systems and is compatible with Lithium, LiFePo4, and Lead Acid batteries. Ensure your battery type and voltage are correctly configured in the inverter settings for optimal performance and longevity.
  • Output Voltage Selection: SUMRY inverters are available in different AC output voltage configurations (e.g., 110VAC or 220VAC). Please verify the specific model you purchased to ensure it matches your regional electrical standards and appliance requirements. This inverter series typically provides a single phase AC output. If you require a split-phase 220V system (common in some regions like the USA), consult a qualified electrician to determine if your specific model supports this configuration or if additional equipment is needed.
  • WIFI Module: If you have the optional WIFI module, download the 'smartess' app to monitor your system's performance and adjust settings conveniently from your smartphone.

10. Frequently Asked Questions

Q: Does this inverter support 48 VDC lithium batteries?
A: Yes, the SUMRY MPS-VIII ECO series supports 24VDC and 48VDC battery systems, including Lithium and LiFePo4 types. Ensure the correct battery type is selected in the inverter's settings.
Q: Can I use two 110V AC outputs to create a 220V split-phase system for USA use?
A: This inverter series typically provides a single phase AC output (either 110VAC or 220VAC, depending on the model purchased). It is not designed to combine two 110V outputs to create a split-phase 220V system. For split-phase requirements, a different inverter model or specific wiring configuration by a qualified electrician might be necessary. Always refer to your specific model's detailed specifications and consult a professional.
Q: Is there a 220V version available?
A: Yes, the SUMRY MPS-VIII ECO series is available in both 110VAC and 220VAC output versions. Please ensure you select the appropriate model for your region's electrical standards.

11. Warranty and Support

SUMRY products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please contact your authorized dealer or the SUMRY Official Store. Keep your purchase receipt as proof of purchase for warranty claims.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.