1. Product Overview
The PowMr POW-SunSmart 10KP is an all-in-one hybrid solar inverter designed to integrate solar energy storage, utility charging, and energy storage with AC sine wave output. It features advanced DSP control for high response speed and reliability, making it suitable for various industrial and residential applications. This model offers a rated power of up to 10 KW and supports both single-phase and split-phase applications.

PowMr POW-SunSmart 10KP Hybrid Solar Inverter
Video: Overview of the PowMr POW-SunSmart 10KP Hybrid Solar Inverter.
2. Important Safety Instructions
Please save these instructions for future use!
- Read all of the instructions and cautions in the manual before beginning the installation!
- Installation and wiring must comply with the Local and National Electric Codes (NEC) and must be done by a certified technician.
- Do NOT disassemble or attempt to repair the inverter. There are no serviceable parts for this inverter.
- DO NOT parallel this device with other AC input sources to avoid damage.
- DO NOT attempt to touch the unit while it is operating as temperatures will be very hot. In addition, do not open the terminal cover while the unit is in operation.
- Make sure all connections going into and from the inverter are tight. There may be sparks when making connections, therefore, make sure there are not flammable materials or gases near installation.
- Installing breakers or fuses outside of the unit is recommended.
- After installation, check that all line connections are tight and secured.
- Do NOT let the positive (+) and negative (-) terminals of the battery touch each other. Use Lithium batteries or deep cycle Sealed Lead Acid, Flooded, Gel, AGM batteries.
- Explosive battery gases may be present while charging. Be certain there is enough ventilation to release the gases.
- Be careful when working with large lead acid batteries. Wear eye protection and have fresh water available in case there is contact with the battery acid.
- Over-charging and excessive gas precipitation may damage the battery plates and activate material shedding on them. Too high of an equalizing charge or too long of one may cause damage. Please carefully review the specific requirements of the battery used in the system.
3. Product Features
- Multifunctional Solar Inverter: UL1741 Standard POW-SunSmart split-phase solar inverter integrates solar energy storage & utility charging and energy storage, AC sine wave output.
- Dual MPPT: Features 99.9% efficiency and a maximum 22A current in a single circuit, perfectly adapted to high-power modules. Supports two solar inputs and simultaneous tracking of two solar maximum power charging/carrying capacity functions.
- Battery Compatibility: Compatible with AGM, Gel, Lead acid, Lithium-ion, and LiFePO4 batteries, and supports batteryless operation. Supports solar, utility, or generator power to charge the battery.
- Dual Activation Function: When the Li-ion battery is dormant, either mains or photovoltaic power supply access can trigger its activation.
- Output Modes: Supports split-phase and single-phase pure sine wave output. Offers four different voltage levels: 100Vac, 105Vac, 110Vac, 115Vac, 120Vac, and 127Vac per phase.
- Charging Modes: Four optional charging modes: solar only, mains priority, solar priority, and mixed mains/PV charging. Two output modes: utility bypass and inverter output, with uninterrupted power supply function.
- Time-Slot Charging/Discharging: Function to set time periods for mains charging and switching between battery discharging and mains bypass power supply mode, optimizing clean solar energy use.
- Energy Saving Mode: Reduces no-load energy losses.
- LCD Display: Large screen dynamic flow diagram design for easy understanding of system data and operation status.
- 360° Protection: Complete short circuit, over current, over/under voltage, overload, and backfill protection.
- Communication: Supports CAN, USB, and RS485 communication.

Key features of the 10KW Split-Phase Hybrid Solar Inverter.

LCD HD Display Screen for real-time monitoring.

Comprehensive 360-degree protection features.

Internal cooling system with 4 powerful fans.
4. Technical Specifications

Detailed Technical Specifications for PowMr POW-SunSmart 10KP.
| Feature | Specification |
|---|---|
| Model Number | POW-SunSmart 10KP |
| Rated Output Power | 10KW |
| Output Current | MPPT 200A |
| Rated Battery Voltage | 48Vdc |
| Rated Output Voltage | 120/240Vac |
| Output Frequency | 50/60Hz |
| Waveform | Pure Sine Wave |
| Max. PV Array Power | 11000W |
| Max. Voltage of Open Circuit | 500Vdc |
| Number of MPPT Trackers | 2 |
| Size (L*W*D) | 620*445*130(mm) |
| Weight | 29kg |
| Is Smart Device | Yes |
| EU LVD Voltage | High voltage: Above 50Vac or 75Vdc |
5. Package Contents
Upon unboxing your PowMr POW-SunSmart 10KP Hybrid Solar Inverter, you should find the following items:
- POW-SunSmart 10KP Hybrid Solar Inverter unit
- Installation Manual (User Manual)
- Cable Lugs and screws for installation
- Warranty Card

Contents included in the box: Solar Inverter, Instruction Manual, Cable Lugs and screws.
6. Setup and Installation
6.1 Select the Mount Location
The POW-SunSmart series is designed for INDOOR USE ONLY (IP20). Consider the following when selecting the location:
- Choose a solid wall for installation.
- Mount the inverter at eye level.
- Ensure adequate heat dissipation space is provided.
- The ambient temperature should be between -10~55℃ (14~131°F) for optimal operation.
DANGER:
- Do not install where highly flammable materials are nearby.
- Do not install in potential explosive areas.
- Do not install with lead-acid batteries in a confined space.
CAUTION:
- Do not install in direct sunlight.
- Do not install or use in a humid environment.

Inverter dimensions and recommended mounting clearances.
6.2 Mount the Inverter
Make 4 mounting holes in the wall with an electric drill according to the specified dimensions. Insert 2 expansion screws above and fix the inverter with 2 M5 screws below.
6.3 Remove the Terminal Cover and Insect Screen
Using a screwdriver, remove the terminal protection cover and insect screen.
NOTICE:
- When using the device in areas with poor air quality, the dust screen is easily blocked by airborne particles. Please dismantle and clean the dust screen regularly to avoid affecting the internal air flow rate of the inverter, which may trigger an over-temperature protection fault (19/20 fault) affecting the use of the power supply and the service life of the inverter.
6.4 Connection Overview
The system consists of PV modules, utility grid or generator, battery, home load, and the inverter. The actual application scenario determines the specific system wiring method.

Overview of inverter ports and connections.
6.5 Cable & Circuit Breaker Requirement
Ensure all cables and circuit breakers meet the specified requirements for safety and optimal performance. Refer to the detailed table in the full PDF manual for specific gauges and ratings.
6.6 AC Input & Output Connection
Connect the live, neutral, and ground wires according to the cables' position and order shown in the diagram below. Torque to 1.5NM.
DANGER:
- Before connecting AC inputs and outputs, the circuit breaker must be opened to avoid the risk of electric shock and must not be operated with electricity.
- Please check that the cable used is sufficient for the requirements; too thin, poor quality cables are a serious safety hazard.
6.7 Battery Connection
Connect the positive and negative cable of the battery according to the diagram below. Torque to 3NM.
DANGER:
- Before connecting battery, the circuit breaker must be opened to avoid the risk of electric shock and must not be operated with electricity.
- Make sure that the positive and negative terminals of the battery are connected correctly and not reversed, otherwise the inverter may be damaged.
- Please check that the cable used is sufficient for the requirements; too thin, poor quality cables are a serious safety hazard.

Inverter compatible with 48V Lead-Acid and Lithium batteries, and can run batteryless.
6.8 PV Connection
Connect the positive and negative wires of the two strings of PV according to the diagram below. Torque to 1.2NM.
DANGER:
- Before connecting PV, the circuit breaker must be opened to avoid the risk of electric shock and must not be operated with electricity.
- Make sure that the open circuit voltage of the PV modules in series does not exceed the Max. Open Circuit Voltage of the inverter (500V for POW-SunSmart series), otherwise the inverter may be damaged.

Wiring diagrams for Split-Phase and Single-Phase modes. Note PV panel voltage limits.
6.9 Dry Contact Connection
Use a small screwdriver to push back the direction indicated by the arrow, then insert the communication cable into the dry junction port (0.2~1.5mm²).
6.10 Grounding Connection
Ensure the grounding terminal connects to the Grounding Busbar. Torque to 2NM.
NOTICE:
- The grounding cable should have a diameter of not less than 4 mm² and be as close as possible to the grounding point.
6.11 Inverter Start
After confirming reliable wiring and correct wiring sequence, restore the terminal cover to its original position.
- Close the circuit breaker of the battery.
- Press the rocker switch at the bottom of the inverter; the screen and indicator will light up, indicating that the inverter is enabled.
- Close the circuit breakers for PV input, AC input, and AC output in sequence.
- Start loads one by one in order of power from small.
6.12 Parallel Connection
The inverter supports parallel operation of up to six units. When using the parallel function, it is necessary to connect the parallel communication cable in a correct and reliable manner. Refer to the full PDF manual for detailed wiring diagrams for single-phase, two-phase, and three-phase parallel connections.
Warning for Parallel Connection:
- PV wiring: In parallel connection, the PV array of each inverter must be independent.
- Battery wiring: All solar storage inverters must be connected to the same battery. Ensure correct connection, wiring length, and cable size before power on.
- AC OUT wiring: In single-phase parallel connection, all inverters must be connected L-to-L, N-to-N, and PE-to-PE. In three-phase parallel connection, L lines of all inverters in the same phase shall be connected together, but L lines of different phases shall not be connected together.
- AC IN wiring: In single-phase parallel connection, all inverters must be connected L-to-L, N-to-N, and PE-to-PE. Do not have multiple different AC source inputs.
- Communication wiring: Use a DB15 standard computer cable with shielding. Each inverter shall be connected with one out and one in.
7. Operation
7.1 Operation and Display Panel
The inverter's operation and display panel includes an LCD screen, three indicators, and four touchable keys for navigation and settings.

Overview of the LCD display panel and touchable keys.

Detailed explanation of LCD display icons and their meanings.
7.2 View Real-time Data
From the main screen, press the UP / DOWN keys to view the real-time data of the inverter during operation. This includes PV input voltage/current/power, battery voltage/current, AC input/output data, and load data.
7.3 Setting Parameters
The inverter allows for various parameter settings to customize its operation. These settings are accessed via the setup menu using the touchable keys. Key parameters include AC output source priority (UTI, SBU, SOL), AC output frequency, AC input voltage range, battery to mains voltage threshold, mains to battery voltage threshold, battery charging mode, max charging current, battery type, battery boost/float charging voltage, discharge voltage limits, and equalization charging settings. Refer to the full PDF manual for a complete list of parameters and their detailed descriptions.
7.4 AC Output Mode
The AC output mode determines how the inverter prioritizes power sources for the load. Options include Utility Priority (UTI), Solar and Utility Hybrid (SUB - default), and Solar Priority (SOL).
7.5 Battery Charging Mode
The charging mode determines how the battery is charged. Options include Hybrid Charging (SNU - default) and Solar Charging Only (OSO). SNU charges the battery from both solar and utility, prioritizing solar. OSO charges only from solar energy.
7.6 Time-slot Charging/Discharging Function
This function allows users to set specific time periods for charging and discharging, optimizing energy use based on local electricity tariffs. This can help maximize the use of solar energy and reduce electricity costs.
8. Communication
The inverter supports various communication interfaces for monitoring and control:
- USB-B Port: Used to connect to a computer for reading and modifying device parameters via upper computer software.
- WIFI Port: Connects to a Wi-Fi/GPRS data acquisition module (purchased separately) to view operation status and parameters via a mobile APP.
- RS485/CAN Port: Used to connect to the BMS (Battery Management System) of a Li-ion battery. Contact support for communication protocols or software upgrades if needed.
- Dry Contact Port: Has two functions: battery temperature sampling and remote generator start/stop.

WIFI connection for remote monitoring and control via mobile app.
9. Troubleshooting
This section provides guidance on common fault codes and troubleshooting steps. For a complete list of fault codes and detailed remedies, please refer to the full PDF user manual.
9.1 Common Fault Codes and Remedies
| Fault Code | Meaning | Remedy |
|---|---|---|
| No screen display | No power input or device switch is off. | Check battery/PV air-switch, ensure switch is 'ON', press any button to exit sleep mode. |
| 01 | Battery under-voltage | Charge battery until voltage is higher than parameter [14] setting. |
| 03 | Disconnected battery | Check battery connection, circuit breaker, and BMS communication. |
| 04 | Battery over-discharge | Manual reset: Power off and restart. Auto reset: Charge battery until voltage is higher than parameter [35]. |
| 06 | Battery over-voltage when charging | Discharge battery until voltage is below recovery point. |
| 13 | Bypass overload (software detection) | Reduce load power and restart. |
| 19 | Over-temperature (MPPT heat sink) | Resume normal operation once temperature cools down. |
| 21 | Fan failure | Manually toggle fan, check for blockages. If persistent, contact service. |
| 28 | Line/Phase Error (Utility input) | Ensure AC input phase matches AC output phase. |
NOTICE:
- If you encounter product faults that cannot be solved by the methods listed above, please contact our after-sales service department for technical support, and do not disassemble the device yourself.
10. Maintenance
To maintain optimum and long-lasting working performance, we recommend checking the following items twice a year:
- Ensure that the airflow around the inverter is not blocked and remove any dirt or debris from the radiator.
- Check that all exposed conductors are not damaged by sunlight, friction, dry rot, insect, or rodent damage. Repair or replace conductors if necessary.
- Verify that indications and displays are consistent with equipment operation. Note any faults or incorrect displays and take corrective action.
- Check all terminals for signs of corrosion, insulation damage, high temperatures, or burning/discoloration and tighten terminal screws.
- Check for dirt, nesting insects, and corrosion. Clean the insect screen regularly.
- If the lightning arrester has failed, replace it in time to prevent lightning damage to the inverter or other equipment.
DANGER:
- Before conducting any inspection or operation, ensure the inverter is disconnected from all power sources and that the capacitor is fully discharged to avoid electric shock.
11. User Tips
- Battery-less Operation: This inverter supports operation without batteries, using only solar panels and the grid. Ensure proper configuration for this mode.
- Frequency Compatibility: The inverter can output split-phase 120/240 Volts at both 50Hz and 60Hz, making it versatile for different regional power standards.
- Positive Feedback: Users generally report that the inverter works well and performs as expected.
12. Warranty and Support
The PowMr POW-SunSmart 10KP Hybrid Solar Inverter comes with a 2-year warranty.
For detailed information, technical support, or warranty claims, please refer to the official user manual PDF or contact PowMr customer service.
You can find the full user manual (PDF) at: PowMr POW-SunSmart 8KP & 10KP User Manual (PDF)
Contact Information: